Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Abhijeet Dhoble is active.

Publication


Featured researches published by Abhijeet Dhoble.


Jacc-cardiovascular Imaging | 2009

Safety of Contrast Agent Use During Stress Echocardiography: A 4-Year Experience From a Single-Center Cohort Study of 26,774 Patients

Sahar S. Abdelmoneim; Mathieu Bernier; Christopher G. Scott; Abhijeet Dhoble; Sue Ann C. Ness; Mary E. Hagen; Stuart Moir; Robert B. McCully; Patricia A. Pellikka; Sharon L. Mulvagh

OBJECTIVES We evaluated the short- and long-term safety of contrast agents during stress echocardiography (SE). BACKGROUND Concerns about contrast agent safety led to revised recommendations for product use in the U.S. METHODS We studied 26,774 patients who underwent SE between November 1, 2003, and December 31, 2007. The 10,792 patients who comprised the contrast cohort received second-generation perfluorocarbon-based agents for left ventricular opacification during SE. The noncontrast cohort comprised 15,982 patients who had their first SE in the same period but without contrast agents. Short-term (< or = 72 h and < or = 30 days) and long-term (up to 4.5 years) end points were death and myocardial infarction (MI). Cox regression models were used. Immediate contrast agent-related adverse effects were also reported. RESULTS The contrast cohort had older patients (mean [SD] age, 65.8 [12.1] years vs. 62.6 [14.1] years; p < 0.001), a higher percentage of males (57.4% vs. 52.8%, p < 0.001), and higher-risk patients compared with the noncontrast cohort. In addition, dobutamine SE patients had greater cardiac risk than exercise SE patients. Abnormal SE findings in patients who received contrast agents were more frequent (32.4% vs. 27.9%, p < 0.001). The 2 cohorts had no statistical difference in the incidence of short-term events (death and MI). Within 72 h, 1 patient in the contrast cohort and 2 patients in the noncontrast cohort died (p = 0.54); 3 in the contrast cohort and 7 in the noncontrast cohort had MI (p = 0.92). Within 30 days, 37 patients (0.34%) in the contrast cohort and 57 patients (0.36%) in the noncontrast cohort died (p = 0.85); 17 patients (0.16%) in the contrast cohort and 16 patients (0.10%) in the noncontrast cohort had MI (p = 0.19). Adjusted hazard ratios were not different between cohorts for death (0.99; 95% confidence interval: 0.88 to 1.11) or MI (0.99; 95% confidence interval: 0.80 to 1.22). CONCLUSIONS The use of contrast agents during SE was not associated with an increased short-term or long-term risk of death or MI.


Journal of The American Society of Echocardiography | 2009

Microvascular Function in Takotsubo Cardiomyopathy With Contrast Echocardiography: Prospective Evaluation and Review of Literature

Sahar S. Abdelmoneim; Sunil Mankad; Mathieu Bernier; Abhijeet Dhoble; Mary E. Hagen; Sue Ann C. Ness; Krishnaswamy Chandrasekaran; Patricia A. Pellikka; Jae Kuen Oh; Sharon L. Mulvagh

BACKGROUND Takotsubo cardiomyopathy (TC) mimics ST-elevation myocardial infarction without substantial angiographic stenosis. Coronary microvascular dysfunction has been proposed as a possible mechanism in TC. The aim of this study was to evaluate microvascular function in TC using real-time myocardial contrast echocardiography (MCE). METHODS Real-time MCE was performed within 24 hours of coronary angiographic diagnosis of TC. Myocardial perfusion was evaluated through qualitative and quantitative myocardial contrast echocardiographic analyses comparing normal segments with segments with dysfunctional wall motion (WM). RESULTS From January 2007 to January 2008, 11 patients received diagnoses of TC. Of these patients, 9 were prospectively enrolled (mean age, 70.9 +/- 17.5 years; 8 women). Qualitative and quantitative myocardial contrast echocardiographic analyses were feasible in 87% and 81% of segments. Overall, concordance between qualitative MCE and WM for normal versus abnormal analysis was observed in 71% of segments (kappa = 0.442, SE = 0.08). Significantly lower myocardial blood flow velocity (beta) and lower myocardial blood flow (Abeta) were detected in segments with dysfunctional WM compared with those with normal WM (beta = 0.55 +/- 0.39 vs 0.90 +/- 0.77, P = .009; Abeta = 5.31 +/- 3.92 vs 12.38 +/- 13.47, P = .002). In the discordant segments between qualitative MCE and WM, the quantitative perfusion parameters beta and Abeta were significantly lower in segments with dysfunctional WM compared with those with normal WM (beta = 0.22 +/- 0.20 vs 1.79 +/- 0.57, P = .01; Abeta = 1.90 +/- 1.1 vs 24.29 +/- 19.9, P = .02). Recovery of WM abnormalities was detected in all patients during follow-up echocardiography (mean, 60.3 +/- 66.0 days). No contrast-related side effects were reported. During mean follow-up of 5.9 +/- 4.6 months, there were no cardiac events, but 1 noncardiac death (from lung cancer) occurred. CONCLUSION TC is associated with abnormal myocardial perfusion detected with qualitative and quantitative MCE, indicative of microvascular dysfunction.


Circulation-cardiovascular Imaging | 2010

Safety of Contrast Agent Use during Stress Echocardiography in Patients with Elevated Right Ventricular Systolic Pressure: A Cohort Study

Sahar S. Abdelmoneim; Mathieu Bernier; Christopher G. Scott; Abhijeet Dhoble; Sue Ann C. Ness; Mary E. Hagen; Stuart Moir; Robert B. McCully; Patricia A. Pellikka; Sharon L. Mulvagh

Background—Microbubble safety concerns led to changes in product recommendations for patients with pulmonary hypertension. Noninvasive estimation of right ventricular systolic pressure (RVSP) is equivalent to pulmonary artery systolic pressure in the absence of pulmonary outflow obstruction. We analyzed the short- and long-term outcomes of patients who received microbubble contrast and those who did not during stress echocardiography (SE) according to resting RVSP. Methods and Results—From November 2003 to December 2007, 26 774 patients underwent SE. RVSP (mean, 32.6±9.6 mm Hg) was measured in 16 434 patients. Of these, 6164 (37.5%) received contrast for left ventricular opacification and 10 270 (62.5%) did not. Short-term (≤72 hours and ≤30 days) and long-term (4.3 years) end points were death and myocardial infarction. Analysis was done for rest RVSP cut-points ≥35, ≥50, and ≥60 mm Hg and tricuspid regurgitant velocities ≥2.7 ms−1 and ≥3.5 ms−1. Adjusted Cox regression models were used. The contrast cohort comprised older patients (age, 67±12 versus 64±14 years; P<0.001), who were more likely to have positive SE results (35% versus 30%, P<0.001) compared with the noncontrast cohort. Using RVSP ≥50 mm Hg, there was no significant difference in short-term events between the contrast and noncontrast cohorts. For long-term events, there was no significant difference between both cohorts (adjusted hazard ratios [95% confidence intervals] for death, 1.10 [0.80 to 1.50], P=0.56; and myocardial infarction, 0.34 [0.11 to 1.03], P=0.06). Similar results were obtained at different RVSP and tricuspid regurgitant cut-points. Contrast agent-related adverse effects occurred in <1% of patients. Conclusion—RVSP had no impact on predisposition to adverse outcomes in patients undergoing contrast SE in the population studied.


Journal of the American Heart Association | 2014

Cardiopulmonary Fitness and Heart Rate Recovery as Predictors of Mortality in a Referral Population

Abhijeet Dhoble; Brian D. Lahr; Thomas G. Allison; Stephen L. Kopecky

Background Exercise testing provides valuable information in addition to ST‐segment changes. The present study evaluated the associations among exercise test parameters and all‐cause mortality in a referral population. Methods and Results We examined conventional cardiovascular risk factors and exercise test parameters in 6546 individuals (mean age 49 years, 58% men) with no known cardiovascular disease who were referred to our clinic for exercise stress testing between 1993 and 2003. The association of exercise parameters with mortality was assessed during a follow‐up of 8.1±3.7 years. A total of 285 patients died during the follow‐up period. Adjusting for age and sex, the variables associated with mortality were: smoking, diabetes, functional aerobic capacity (FAC), heart rate recovery (HRR), chronotropic incompetence, and angina during the exercise. Adjusting for cardiovascular risk factors (diabetes, smoking, body mass index, blood pressure, serum total, HDL, LDL cholesterol, and triglycerides) and other exercise variables in a multivariable model, the only exercise parameters independently associated with mortality were lower FAC (adjusted hazard ratio [HR] per 10% decrease in FAC, 1.21; 95% confidence interval [CI], 1.13 to 1.29; P<0.001), and abnormal HRR, defined as failure to decrease heart rate by 12 beats at 1 minute recovery (adjusted HR per 1‐beat decrease, 1.05; 95% CI, 1.03 to 1.07; P<0.001). The additive effects of FAC and HRR on mortality were also highly significant when considered as categorical variables. Conclusion In this cohort of patients with no known cardiovascular disease who were referred for exercise electrocardiography, FAC and HRR were independently associated with all‐cause mortality.


European Journal of Echocardiography | 2009

Quantitative myocardial contrast echocardiography during pharmacological stress for diagnosis of coronary artery disease: a systematic review and meta-analysis of diagnostic accuracy studies.

Sahar S. Abdelmoneim; Abhijeet Dhoble; Mathieu Bernier; Patricia J. Erwin; Grigorios Korosoglou; Roxy Senior; Stuart Moir; Ingrid Kowatsch; Shu Xianhong; Takashi Muro; Dana Dawson; Rolf Vogel; Kevin Wei; Colin P. West; Victor M. Montori; Patricia A. Pellikka; Samir S. Abdel-Kader; Sharon L. Mulvagh

AIMS We conducted a meta-analysis to evaluate the accuracy of quantitative stress myocardial contrast echocardiography (MCE) in coronary artery disease (CAD). METHODS AND RESULTS Database search was performed through January 2008. We included studies evaluating accuracy of quantitative stress MCE for detection of CAD compared with coronary angiography or single-photon emission computed tomography (SPECT) and measuring reserve parameters of A, beta, and Abeta. Data from studies were verified and supplemented by the authors of each study. Using random effects meta-analysis, we estimated weighted mean difference (WMD), likelihood ratios (LRs), diagnostic odds ratios (DORs), and summary area under curve (AUC), all with 95% confidence interval (CI). Of 1443 studies, 13 including 627 patients (age range, 38-75 years) and comparing MCE with angiography (n = 10), SPECT (n = 1), or both (n = 2) were eligible. WMD (95% CI) were significantly less in CAD group than no-CAD group: 0.12 (0.06-0.18) (P < 0.001), 1.38 (1.28-1.52) (P < 0.001), and 1.47 (1.18-1.76) (P < 0.001) for A, beta, and Abeta reserves, respectively. Pooled LRs for positive test were 1.33 (1.13-1.57), 3.76 (2.43-5.80), and 3.64 (2.87-4.78) and LRs for negative test were 0.68 (0.55-0.83), 0.30 (0.24-0.38), and 0.27 (0.22-0.34) for A, beta, and Abeta reserves, respectively. Pooled DORs were 2.09 (1.42-3.07), 15.11 (7.90-28.91), and 14.73 (9.61-22.57) and AUCs were 0.637 (0.594-0.677), 0.851 (0.828-0.872), and 0.859 (0.842-0.750) for A, beta, and Abeta reserves, respectively. CONCLUSION Evidence supports the use of quantitative MCE as a non-invasive test for detection of CAD. Standardizing MCE quantification analysis and adherence to reporting standards for diagnostic tests could enhance the quality of evidence in this field.


Clinical Cardiology | 2009

Cardiac Amyloidosis Treated with an Implantable Cardioverter Defibrillator and Subcutaneous Array Lead System: Report of a Case and Literature Review

Abhijeet Dhoble; Atul Khasnis; Adesuwa Olomu; Ranjan K. Thakur

Preventing ventricular arrhythmias in patients with cardiac amyloidosis is challenging since the amyloid protein deposition in the myocardium may interfere with the normal cardiac electric excitation. Most of these patients succumb to either progressive congestive heart failure, or sudden cardiac death (SCD). Implantable Cardioverter Defibrillator (ICD) offers a near sure means of preventing SCD.


The American Journal of Medicine | 2012

Safety of Symptom-limited Cardiopulmonary Exercise Testing in Patients with Aortic Stenosis

Abhijeet Dhoble; Maurice E. Sarano; Stephen L. Kopecky; Randal J. Thomas; Courtney L. Hayes; Thomas G. Allison

BACKGROUND There are no published data on the safety of cardiopulmonary exercise testing in patients with aortic stenosis. METHODS In this retrospective descriptive study, we examined 347 consecutive patients with aortic stenosis who underwent cardiopulmonary exercise testing at a tertiary referral center. We recorded major events including death, nonfatal major events (cardiac arrest, symptomatic or sustained ventricular or supraventricular tachycardia, myocardial infarction, and syncope), and minor events such as hypotension, nonsustained supraventricular and ventricular arrhythmias, positive electrocardiographic changes, and angina. RESULTS Of 347 patients, 65 (19%) had mild, 145 (42%) had moderate, and 137 (40%) had severe aortic stenosis by echocardiographic criteria. No major events occurred during the tests. Minor events occurred in a total of 97 patients (28%), including 10 patients who developed supraventricular arrhythmias without hypotension; and one who had asymptomatic nonsustained ventricular tachycardia. CONCLUSION Symptom-limited cardiopulmonary exercise testing in cardiology-referred patients with aortic stenosis with preserved systolic function appears to be associated with very low risk of major adverse cardiovascular events during testing.


Echocardiography-a Journal of Cardiovascular Ultrasound and Allied Techniques | 2010

Assessment of Myocardial Perfusion during Adenosine Stress Using Real Time Three‐Dimensional and Two‐Dimensional Myocardial Contrast Echocardiography: Comparison with Single‐Photon Emission Computed Tomography

Sahar S. Abdelmoneim; Mathieu Bernier; Abhijeet Dhoble; Stuart Moir; Mary E. Hagen; Sue Ann C. Ness; Samir S. Abdel-Kader; Patricia A. Pellikka; Sharon L. Mulvagh

Objectives: To evaluate diagnostic accuracy of adenosine two‐dimensional and three‐dimensional myocardial contrast echocardiography (2D‐ and 3D‐MCE) compared with single‐photon emission computed tomography (SPECT) for assessing myocardial perfusion. Methods: From January through August 2007, patients with known or suspected CAD who were referred for SPECT underwent simultaneous adenosine 2D‐MCE and 3D‐MCE (live and full volume [FV]). Perfusion and wall motion in 17 segments in the left anterior descending, left circumflex, and right coronary artery territories were analyzed. Results: We studied 30 patients: mean (SD) age, 72.6 (8.2) years; 19 (63%) men. Perfusion by SPECT was abnormal in 13 patients (43%). When comparing MCE with SPECT, sensitivity was comparable for 2D‐MCE, 92%; live 3D‐MCE, 91%; and FV 3D‐MCE, 90%. Specificity was comparable for 2D‐MCE, 75%; live 3D‐MCE, 69%; and FV 3D‐MCE, 79%. Agreement between live 3D‐MCE and 2D‐MCE was 92% (κ[SE], 0.83 [0.17]) and between FV 3D‐MCE and 2D‐MCE, 88% (κ[SE], 0.76 [0.13]). For eight patients in whom SPECT showed reversible defects, live 3D‐MCE correctly identified defects in seven (88%), whereas FV 3D‐MCE correctly identified them in five (63%) (P = 0.57). Conclusion: Myocardial perfusion assessment is feasible by 3D‐MCE with the advantage of rapid, facile acquisition and offline image manipulation. (Echocardiography 2010;27:421‐429)


Heart and Vessels | 2010

Diagnostic accuracy of contrast echocardiography during adenosine stress for detection of abnormal myocardial perfusion: a prospective comparison with technetium-99 m sestamibi single-photon emission computed tomography

Sahar S. Abdelmoneim; Mathieu Bernier; Abhijeet Dhoble; Stuart Moir; Mary E. Hagen; Sue Ann C. Ness; Patricia A. Pellikka; Samir S. Abdel-Kader; Sharon L. Mulvagh

Myocardial contrast echocardiography (MCE) utilizes compressible microbubbles behaving similarly to red blood cells. Destruction of microbubbles and observation of the gradual refill into the myocardium are key to evaluating perfusion using real-time MCE. We aimed to assess the feasibility and diagnostic accuracy of qualitative MCE utilizing a 17-segment model for localization of myocardial perfusion abnormalities compared with simultaneous technetium-99 m sestamibi single-photon emission computed tomography (SPECT). From July 2005 through August 2007, 97 patients with known or suspected coronary artery disease underwent simultaneous SPECT and realtime MCE during adenosine stress. Qualitative MCE and tracer uptake were analyzed visually using a 17-segment model in a blinded manner. Diagnostic accuracy and 95% confidence interval (CI) were determined. Myocardial contrast echocardiography was completed in 91 patients (age, mean [SD], 69.3 [10.9] years; body mass index, 30.0 [6.3]; 59 males [65%]). Myocardial contrast echocardiography analysis was feasible in 88 (97%) patients (261 of 264 [99%] territories; 1299 of 1497 [87%] segments). At patient level, MCE sensitivity was 88% (95% CI, 79%–94%); specificity was 85% (77%–90%). For disease detection in individual coronary territories, sensitivity and specificity were 84% (71%–92%) and 79% (72%–84%) for the left anterior descending artery; 62% (38%–80%) and 88% (83%–91%) for the left circumflex artery; and 73% (57%–82%) and 94% (89%–97%) for the right coronary artery. For MCE combined with wall-motion analysis, concordance with SPECT improved from 80% to 86%. Myocardial contrast echocardiography interobserver concordance was 81% (κ [SE], 0.611 [0.78]). Myocardial contrast echocardiography accuracy was comparable in patients classified in accordance with presence of diabetes mellitus, myocardial infarction, hypertension, or percutaneous coronary intervention. Improved MCE specificity in detecting perfusion defects was seen in patients with no history of coronary bypass graft surgery (P = 0.005). Real-time MCE with a 17-segment model for analysis has good feasibility and accuracy in evaluation of myocardial perfusion during adenosine stress.


Diabetes and Vascular Disease Research | 2011

Detection of myocardial microvascular disease using contrast echocardiography during adenosine stress in type 2 diabetes mellitus: Prospective comparison with single-photon emission computed tomography

Sahar S. Abdelmoneim; Ananda Basu; Mathieu Bernier; Abhijeet Dhoble; Samir S. Abdel-Kader; Patricia A. Pellikka; Sharon L. Mulvagh

Purrpose: To evaluate myocardial microvascular disease in patients with type 2 diabetes mellitus (DM) using myocardial contrast echocardiography (MCE) and to report on its diagnostic accuracy using single photon emission tomography (SPECT) as reference test. Methods: We prospectively enrolled 79 patients (25 DM; 66±11 years) who underwent simultaneous SPECT and MCE with contrast agent during adenosine stress. MCE and SPECT were visually analyzed using 17 segments. Quantitative MCE parameters were derived from replenishment curves. Microbubble velocity (β min−1), absolute myocardial blood flow (MBF ml/min/g), and reserve values were calculated. Diagnostic accuracy and area under curve (AUC) was reported. Results: Patients with DM had higher BMI vs non DM (33±7 vs 28±5kg/m2 P=0 .007), with more prior myocardial infarction (40 vs 15% P=.01). Visual MCE was abnormal in 40 (51%) patients (60% in DM vs 46% in non DM P=0.04). SPECT was abnormal in 38 (48%) patients [60% in DM vs 42% non DM, P=0.01]. Reserve parameters were lower in DM vs. non DM patients: (β 1.77±1.12 vs 2.20±1.4, P<0.001 and MBF 2.86± 2.62 vs. 3.67±2.84, P<0.001). DM patients without CAD on SPECT had significantly lower β, and MBF reserve compared to non DM patients without CAD. Compared to SPECT, β reserve cutoff 1.6 had AUC 0.817, sensitivity 81%, and specificity 66% while MBF reserve cutoff 1.9 had AUC 0.760, sensitivity 79%, and specificity 63% in DM patients. Conclusion: Diabetes is associated with myocardial microvascular abnormalities as evidenced by abnormal myocardial perfusion on visual and quantitative MCE.

Collaboration


Dive into the Abhijeet Dhoble's collaboration.

Top Co-Authors

Avatar

Richard W. Smalling

University of Texas at Austin

View shared research outputs
Top Co-Authors

Avatar

Prakash Balan

University of Texas at Austin

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Sharon L. Mulvagh

Baylor College of Medicine

View shared research outputs
Top Co-Authors

Avatar

Tom C. Nguyen

University of Texas Health Science Center at Houston

View shared research outputs
Top Co-Authors

Avatar

Viraj Bhise

University of Texas Health Science Center at Houston

View shared research outputs
Top Co-Authors

Avatar

Anthony L. Estrera

University of Texas Health Science Center at Houston

View shared research outputs
Top Co-Authors

Avatar

Stuart Moir

University of Queensland

View shared research outputs
Researchain Logo
Decentralizing Knowledge