Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Achim Lusch is active.

Publication


Featured researches published by Achim Lusch.


Journal of Endourology | 2012

Validation, Correlation, and Comparison of the da Vinci Trainer™ and the da Vinci Surgical Skills Simulator™ Using the Mimic™ Software for Urologic Robotic Surgical Education

Michael A. Liss; Corollos S. Abdelshehid; Stephen Quach; Achim Lusch; Joseph A. Graversen; Jaime Landman; Elspeth M. McDougall

PURPOSE Virtual reality simulators with self-assessment software may assist novice robotic surgeons to augment direct proctoring in robotic surgical skill acquisition. We compare and correlate the da Vinci Trainer™ (dVT) and da Vinci Surgical Skills Simulators (dVSSS) in subjects with varying robotic experience. MATERIALS AND METHODS Students, urology residents, fellows, and practicing urologists with varying robotic experience were enrolled after local institutional review board approval. Three virtual reality tasks were preformed in sequential order (pegboard 1, pegboard 2, and tubes)-initially on the dVSSS and then on the dVT. The Mimic™ software used on both systems provides raw values and percent scores that were used in statistical evaluation. Statistical analysis was performed with the two-tailed independent t-test, analysis of variance, Tukey, and the Pearson rank correlation coefficient where appropriate. RESULTS Thirty-two participants were recruited for this study and separated into five groups based on robotic surgery experience. In regards to construct validity, both simulators were able to differentiate differences among the five robotic surgery experience groups in the tubes suturing task (p≤0.00). Sixty-seven percent (4/6) robotic experts thought that surgical simulation should be implemented in residency training. The overall cohort considered both platforms easy to learn and use. CONCLUSIONS Although performance scores were less in the dVT compared with the dVSSS, both simulators demonstrate good content and construct validity. The simulators appear to be equivalent for assessing surgeon proficiency and either can be used for robotic skills training with self-assessment feedback.


Journal of Endourology | 2014

Evaluation of the impact of three-dimensional vision on laparoscopic performance.

Achim Lusch; Philip Bucur; Ashleigh Menhadji; Zhamshid Okhunov; Michael A. Liss; Alberto Perez-Lanzac; Elspeth M. McDougall; Jaime Landman

INTRODUCTION Recent technological advancements have led to the introduction of new three-dimensional (3D) cameras in laparoscopic surgery. The 3D view has been touted as useful during robotic surgery, however, there has been limited investigation into the utility of 3D in laparoscopy. MATERIALS AND METHODS We performed a prospective, randomized crossover trial comparing a 0° 3D camera with a conventional 0° two-dimensional (2D) camera using a high definition monitor (Karl Storz, Tuttlingen, Germany). All participants completed six standardized basic skills tasks. Quality testing scores were measured by the number of drops, grasping attempts, and precision of needle entry and exiting. Additionally, resolution, color distribution, depth of field and distortion were measured using optical test targets. RESULTS In this pilot study, we evaluated 10 medical students, 7 residents, and 7 expert surgeons. There was a significant difference in the performance in all the six skill tasks, for the three levels of surgical expertise and training levels in 2D vs 3D except for the cut the line quality score and the peg transfer quality score. Adjusting for the training level, 3D camera image results were superior for the number of rings left (p=0.041), ring transfer quality score (p=0.046), thread the rings (no. of rings) (p=0.0004), and thread the rings quality score (p=0.0002). The 3D camera image was also superior for knot tying (quality score) (p=0.004), peg transfer (time in seconds) (p=0.047), peg transfer pegs left (p=0.012), and for peg transfer quality score (p=0.001). The 3D camera system showed significantly less distortion (p=0.0008), a higher depth of field (p=0.0004) compared with the 2D camera system. CONCLUSION 3D laparoscopic camera equipment results in a significant improvement in depth perception, spatial location, and precision of surgical performance compared with the conventional 2D camera equipment. With this improved quality of vision, even expert laparoscopic surgeons may benefit from 3D imaging.


The Journal of Urology | 2012

Robot-Assisted Radical Prostatectomy: 5-Year Oncological and Biochemical Outcomes

Michael A. Liss; Achim Lusch; Blanca Morales; Nima Beheshti; Douglas Skarecky; Navneet Narula; Kathryn Osann; Thomas E. Ahlering

PURPOSE We investigated oncological outcomes in patients who underwent robot-assisted radical prostatectomy more than 5 years previously. MATERIALS AND METHODS Between June 2002 and August 2006 we prospectively followed 435 consecutive patients who underwent robot-assisted radical prostatectomy. Five patients were excluded from analysis, including 4 lost to followup and 1 with prior therapy. Biochemical recurrence was denoted as 1) adjuvant therapy or 2) 2 prostate specific antigen values above 0.2 ng/ml. Biochemical recurrence-free survival, and patient and tumor characteristics were investigated. RESULTS Mean ± SD patient age was 61.4 ± 7.1 years. A total of 289 patients (63%) had 5 or more years of followup and 4 (1%) were lost to followup. Median time to biochemical recurrence was 18 months (range 1 month to 9.1 years). Four patients (0.93%) died of prostate cancer. The 5-year biochemical recurrence-free survival rate was 84.9% (95% CI 81.4-88.4). Five-year biochemical recurrence-free survival was 94.4% (95% CI 91.7-97.1) for pT2 disease compared to 63.8% (95% CI 53.4-74.1) and 47.1% (95% CI 27.3-67.0) for pT3a and pT3b, respectively (p <0.001). Patients with a Gleason score of 3 or less + 3, 3 + 4, 4 + 3 and 4 or greater + 4 experienced a 5-year biochemical recurrence-free survival of 97%, 86%, 62% and 43%, respectively (p <0.001). Patients with positive margins had a 5-year biochemical recurrence-free survival of 60.7% (95% CI 48.7-72.7) compared to 89.6% (95% CI 86.3-92.9) in those with negative margins (p <0.001). CONCLUSIONS This represents the third report of the oncological outcomes of robot-assisted radical prostatectomy, demonstrating a 5-year biochemical recurrence rate of approximately 14% and just below 1% prostate cancer specific mortality.


Journal of Endourology | 2013

Interobserver Reliability and Reproducibility of S.T.O.N.E. Nephrolithometry for Renal Calculi

Zhamshid Okhunov; Mohammad Helmy; Alberto Perez-Lansac; Ashleigh Menhadji; Philip Bucur; Surendra B. Kolla; Jane S. Cho; Kathy Osann; Achim Lusch; Jaime Landman

PURPOSE To assess the reliability of the S.T.O.N.E. (stone size [S], tract length [T], obstruction [O], number of involved calices [N], and essence or stone density [E]) nephrolithometry scoring system by testing its reproducibility between different observers. PATIENTS AND METHODS Preoperative images of 58 patients who underwent percutaneous nephrolithotomy (PCNL) were reviewed. Medical students, urology residents, one fellow, and a urology attending independently reviewed all images and scored the renal stones. Interobserver reliabilities of the total score for all categories and each component were evaluated by the intraclass correlation (ICC) and a κ coefficient. RESULTS The interobserver reliability for the total score demonstrated high correlations for all components and total score (ICC=S, T, O, N, E and total 0.80, 0.97, 0.89, 0.84, 0.91, and 0.87, respectively). κ rates for individual components between two medical students were 0.36, 1, 0.31, 0.45, 0.33, and 0.30 for the S, T, O, N, E components and total score, respectively. κ values between the two urology residents were 0.71, 1, 0.92, 0.79, 0.93, and 0.67 for S, T, O, N, E components and total score, respectively. κ values between the urology fellow and an attending physician were 0.95, 1, 0.88, 0.94, 0.89, and 0.87 for S, T, O, N, E components and total score, respectively. P value for all the scoring components was <0.05, indicating that the estimated κ was not a result of chance. CONCLUSIONS The S.T.O.N.E. nephrolithometry has excellent interobserver reliability. Quantifying the S and N metrics was the most challenging and least reliable. Standardized protocols to measure these components should be considered to improve accuracy and reproducibility of the scoring system.


Journal of Endourology | 2013

In Vitro and In Vivo Comparison of Optics and Performance of a Distal Sensor Ureteroscope Versus a Standard Fiberoptic Ureteroscope

Achim Lusch; Corollos S. Abdelshehid; Guy Hidas; Kathryn Osann; Zhamshid Okhunov; Elspeth M. McDougall; Jaime Landman

BACKGROUND AND PURPOSE Recent advances in distal sensor technologies have made distal sensor ureteroscopes both commercially and technically feasible. We evaluated performance characteristics and optics of a new generation distal sensor Flex-X(C) (X(C)) and a standard flexible fiberoptic ureteroscope Flex-X(2) (X(2)), both from Karl Storz, Tuttlingen, Germany. MATERIALS AND METHODS The ureteroscopes were compared for active deflection, irrigation flow, and optical characteristics. Each ureteroscope was evaluated with an empty working channel and with various accessories. Optical characteristics (resolution, grayscale imaging, and color representation) were measured using United States Air Force test targets. We digitally recorded a renal porcine ureteroscopy and laser ablation of a stone with the X(2) and with the X(C). Edited footage of the recorded procedure was shown to different expert surgeons (n=8) on a high-definition monitor for evaluation by questionnaire for image quality and performance. RESULTS The X(C) had a higher resolution than the X(2) at 20 and 10 mm 3.17 lines/mm vs 1.41 lines/mm, 10.1 vs 3.56, respectively (P=0.003, P=0.002). Color representation was better in the X(C). There was no difference in contrast quality between the two ureteroscopes. For each individual ureteroscope, the upward deflection was greater than the downward deflection both with and without accessories. When compared with the X(2), the X(C) manifested superior deflection and flow (P<0.0005, P<0.05) with and without accessory present in the working channel. Observers deemed the distal sensor ureteroscope superior in visualization in clear and bloody fields, as well as for illumination (P=0.0005, P=0.002, P=0.0125). CONCLUSIONS In this in vitro and porcine evaluation, the distal sensor ureteroscope provided significantly improved resolution, color representation, and visualization in the upper urinary tract compared with a standard fiberoptic ureteroscope. The overall deflection was also better in the X(C), and deflection as well as flow rate was less impaired by the various accessories.


Urology | 2015

Comparison of Outcomes in Patients Undergoing Percutaneous Renal Cryoablation With Sedation vs General Anesthesia

Zhamshid Okhunov; Samuel Juncal; Michael Ordon; Arvin K. George; Achim Lusch; Michael del Junco; Michael Nguyentat; Igor I. Lobko; Louis R. Kavoussi; Jaime Landman

OBJECTIVE To compare the efficacy and safety of local anesthesia with conscious sedation (LACS) with general anesthesia (GA) in patients undergoing percutaneous renal cryoablation (PRC) for renal cortical neoplasms. METHODS We performed a retrospective review of patients undergoing PRC between 2003 and 2013. Patient demographics, tumor characteristics, and perioperative and postoperative follow-up data were recorded and analyzed. We compared 3 principal outcomes across the GA and LACS groups: anesthesia-related outcomes, treatment failure, and complications. RESULTS A total of 235 patients with available data were included. Of these, 82 underwent PRC under GA and 153 patients under LACS. The 2 groups were similar with regard to age, gender, body mass index, American Society of Anesthesiologists score, tumor features, preoperative serum creatinine level, and hematocrit value. The GA and LACS groups had a similar percentage of patients with biopsy-proven renal cell carcinoma (68.5% and 64.2%, respectively; P = .62). The mean follow-up time for GA and LACS was 37 and 21 months, respectively (P <.0001). The mean procedure time for GA was significantly longer compared with LACS (133 vs 102 minutes; P <.001), and the mean hospital stay was shorter under LACS (1.08 vs 1.95 days; P <.0001). There was no difference in immediate failure (0% and 1.9%; P = .051) or recurrences (11% and 3.9%, respectively; P = .051) between GA and LACS groups. There was no difference in intraoperative and postoperative treatment-related complications between the 2 groups. CONCLUSION PRC for small renal masses under LACS is effective and safe. PRC with LACS has the advantage of decreased procedure time and a shorter hospital stay.


The Journal of Urology | 2014

Intrarenal and Extrarenal Autonomic Nervous System Redefined

Achim Lusch; Ryan P. Leary; Emon Heidari; Michael A. Liss; Zhamshid Okhunov; Alberto Pérez-Lanzac de Lorca; Jiaoti Huang; Jamie Wikenheiser; Jaime Landman

PURPOSE The autonomic nervous supply to the kidneys is involved in the development of several diseases including hypertension. The neural distribution at the segmental vessels and intrarenal vasculature has not been well characterized. Thus, we evaluated the autonomic nerve distribution from the great vessels to the renal cortex in a cadaveric model. MATERIALS AND METHODS We performed a detailed anatomical nerve dissection from the inferior mesenteric artery to the renal operculum in 2 human cadaveric torsos. Autonomic nerve fibers were verified by dissecting the greater splanchnic, sympathetic trunk and ganglia. We then systematically cross-sectioned the kidneys in 12, 1 mm slices across 3.6 cm, and stained the slices for histopathological analysis of neural tissue in relation to segmental arteries and other anatomical landmarks. Advanced reconstructive software was used to create a 3-dimensional computer image. RESULTS Autonomic nerve fibers are located almost exclusively anteriorly on the main renal arteries and segmental arteries, and are absent from veins. Histopathology revealed that the intrarenal nerves continued to track exclusively with the arteries but were more circumferentially distributed. There is minimal nerve tissue around the veins. Many nerves were within a few millimeters of the renal collecting system. CONCLUSIONS The autonomic nerves supplying the kidney maintain their distribution almost exclusively along the anterior surface of arteries as they pass from the aorta to the segmental arteries. Once inside the renal parenchyma, the nerves are circumferentially distributed around the renal arteries and are in close proximity to the renal collecting system.


Urology | 2015

Comparison of Optics and Performance of Single Channel and a Novel Dual-channel Fiberoptic Ureteroscope

Achim Lusch; Zhamshid Okhunov; Michael del Junco; Renai Yoon; Ramtin Khanipour; Ashleigh Menhadji; Jaime Landman

OBJECTIVE To evaluate performance characteristics and optics of a novel dual-working channel fiberoptic ureteroscope (Wolf Cobra) with 2 single-channel fiberoptic ureteroscopes and to a single-channel distal sensor standard definition digital ureteroscope URF-V (SD-DS). METHODS Four new ureteroscopes (Cobra, Viper, X(2), and SD-DS) were compared for active deflection, irrigation flow, and optical characteristics. We performed a porcine ureteroscopy and measured the time for cleaning the middle calyx after injection of 10 cc of a standardized bloody solution. RESULTS The SD-DS showed a higher resolution (7.42 lines/mm; P = .0001) compared with the fiberoptic ureteroscopes; among the fiberoptic ureteroscopes, the Cobra had the highest resolution than the Viper and X(2) (P = .0001). Grayscale distribution and color representation were identical for the fiberoptic ureteroscopes, whereas the SD-DS provided a superior color representation and a significant higher depth of field. The Cobra provided superior flow with empty working channel (86 cc/min vs 68 cc/min [Viper] vs 62.5 cc/min [X(2)] vs 62 cc/min [SD-DS]; P = .0001) and with various accessories (P <.0001). With regard to deflection, the Storz X(2) and the Cobra provided superior deflection up and down (P <.0001). When evacuating a standardized bloody field, the Cobra provided significant shorter evacuation times compared with those of the Viper, X(2), and SD-DS (36.6 vs 72 vs 65.6 vs 72.6 seconds, respectively; P = .0001). CONCLUSION The additional working channel of the Wolf Cobra may improve vision and performance during challenging ureteroscopic cases by providing an increased flow. The enhanced irrigation capabilities of the Cobra have to be balanced with a larger diameter of this ureteroscope.


Urology | 2013

In vitro comparison of a novel facilitated ultrasound targeting technology vs standard technique for percutaneous renal biopsy.

Ashleigh Menhadji; Vien Nguyen; Jane Cho; Ringo Chu; K. Osann; Philip Bucur; Puja Patel; Achim Lusch; Elspeth M. McDougall; Jaime Landman

OBJECTIVE To improve the understanding of the epidemiology of renal cortical neoplasms through pretreatment biopsy, we evaluated a facilitated ultrasound targeting (FUT) technology. The technology allows a needle to be passed through the transducer probe and guided along a virtual dotted line on the monitor. We compared the FUT with standard percutaneous biopsy (PB) technique. MATERIALS AND METHODS Forty-eight participants with various levels of training were recruited. Participants performed ultrasound-guided biopsies on phantom models using FUT and the standard biopsy technique in a randomized sequence. The phantom models consisted of pimento olives embedded in an opaque mold of Metamucil and Knox gelatin. Patients were given up to 10 attempts to achieve 3 complete specimens from the olives. Patients rated each biopsy technique. Results were stratified by level of experience. RESULTS The mean time to obtain 3 complete biopsy specimens was significantly faster for FUT compared with the standard technique (140 seconds vs 246 seconds, P = .0001). The mean number of attempts needed to obtain 3 specimens was significantly less with FUT compared with the standard technique (4.3 vs 5.6 attempts, P = .0007). Patients reported that FUT was significantly easier to use compared with the standard technique (P = .0005). No significant order effect was observed. CONCLUSION In this in vitro comparison, FUT increased the efficiency and efficacy of PB for users of all experience levels. FUT may allow urologists with limited PB experience to perform the procedure reliably and easily. Clinical evaluation of this technology is actively in progress.


Journal of Endourology | 2013

Tracking and assessment of technical skills acquisition among urology residents for open, laparoscopic, and robotic skills over 4 years: is there a trend?

Ashleigh Menhadji; Corollos S. Abdelshehid; K. Osann; Reza Alipanah; Achim Lusch; Joseph A. Graversen; Jason Y. Lee; Stephen Quach; Victor Huynh; Daniel Sidhom; Isabelle Gerbatsch; Jaime Landman; Elspeth M. McDougall

BACKGROUND AND PURPOSE Tracking the progression of technical skill acquisition during urology residency training is an essential yet challenging task that has been mostly based on anecdotal and subjective performance assessment. We evaluated five surgical tasks used at our institution to assess skill acquisition among residents over 4 consecutive years in an effort to determine appropriate skill testing for resident proficiency relative to level of training for future performance testing. METHODS Urology residents were tested yearly throughout the course of their residency with five surgical tasks in an open, laparoscopic, and robotic format. The five tasks were: (1) rings on a peg, (2) thread the rings, (3) cut the line, (4) hexagonal suturing, and (5) suture and knot tying. Evaluation was performed by a trained instructor to assess quantity and quality of the skill task performance. RESULTS The highest scores were obtained on all open tasks regardless of training level. Residents performed second best on robotic and lowest on the laparoscopic skill tasks. The score difference among surgery platforms was statistically significant P<0.0005 across all tasks. It was Tasks 2 and 5, however, that showed a statistically significant difference in overall quantity×quality score between different postgraduate year (PGY) residents (P=0.03 and P=0.02). In addition, the quantity score for Task 5 also showed a statistically significant difference among PGY residents (P=0.04). There was no statistically significant difference in time to perform tasks among PG years. CONCLUSIONS The high-level Tasks 2 and 5 were the most useful in differentiating different levels of skill task competency among urology residents and appear to be most useful in assessing the degree of improvement among residents during training. These tasks have subsequently been worked into our institutions testing curriculum.

Collaboration


Dive into the Achim Lusch's collaboration.

Top Co-Authors

Avatar

Jaime Landman

University of California

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Michael A. Liss

University of Texas Health Science Center at San Antonio

View shared research outputs
Top Co-Authors

Avatar

Elspeth M. McDougall

Washington University in St. Louis

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

C. Winter

Penn State Milton S. Hershey Medical Center

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Peter Albers

University of Düsseldorf

View shared research outputs
Top Co-Authors

Avatar

Kathryn Osann

University of California

View shared research outputs
Researchain Logo
Decentralizing Knowledge