Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Adam S. Kanter is active.

Publication


Featured researches published by Adam S. Kanter.


Neurosurgical Focus | 2010

Complications and radiographic correction in adult scoliosis following combined transpsoas extreme lateral interbody fusion and posterior pedicle screw instrumentation.

Matthew J. Tormenti; Matthew B. Maserati; Christopher M. Bonfield; David O. Okonkwo; Adam S. Kanter

OBJECT The authors recently used a combined approach of minimally invasive transpsoas extreme lateral interbody fusion (XLIF) and open posterior segmental pedicle screw instrumentation with transforaminal lumbar interbody fusion (TLIF) for the correction of coronal deformity. The complications and radiographic outcomes were compared with a posterior-only approach for scoliosis correction. METHODS The authors retrospectively reviewed all deformity cases that were surgically corrected at the University of Pittsburgh Medical Center Presbyterian Hospital between June 2007 and August 2009. Eight patients underwent combined transpsoas and posterior approaches for adult degenerative thoracolumbar scoliosis. The comparison group consisted of 4 adult patients who underwent a posterior-only scoliosis correction. Data on intra- and postoperative complications were collected. The pre- and postoperative posterior-anterior and lateral scoliosis series radiographic films were reviewed, and comparisons were made for coronal deformity, apical vertebral translation (AVT), and lumbar lordosis. Clinical outcomes were evaluated by comparing pre- and postoperative visual analog scale scores. RESULTS The median preoperative coronal Cobb angle in the combined approach was 38.5 degrees (range 18-80 degrees). Following surgery, the median Cobb angle was 10 degrees (p < 0.0001). The mean preoperative AVT was 3.6 cm, improving to 1.8 cm postoperatively (p = 0.031). The mean preoperative lumbar lordosis in this group was 47.3 degrees, and the mean postoperative lordosis was 40.4 degrees. Compared with posterior-only deformity corrections, the mean values for curve correction were higher for the combined approach than for the posterior-only approach. Conversely, the mean AVT correction was higher in the posterior-only group. One patient in the posterior-only group required revision of the instrumentation. One patient who underwent the transpsoas XLIF approach suffered an intraoperative bowel injury necessitating laparotomy and segmental bowel resection; this patient later underwent an uneventful posterior-only correction of her scoliotic deformity. Two patients (25%) in the XLIF group sustained motor radiculopathies, and 6 of 8 patients (75%) experienced postoperative thigh paresthesias or dysesthesias. Motor radiculopathy resolved in 1 patient, but persisted 3 months postsurgery in the other. Sensory symptoms persisted in 5 of 6 patients at the most recent follow-up evaluation. The mean clinical follow-up time was 10.5 months for the XLIF group and 11.5 months for the posterior-only group. The mean visual analog scale score decreased from 8.8 to 3.5 in the XLIF group, and it decreased from 9.5 to 4 in the posterior-only group. CONCLUSIONS Radiographic outcomes such as the Cobb angle and AVT were significantly improved in patients who underwent a combined transpsoas and posterior approach. Lumbar lordosis was maintained in all patients undergoing the combined approach. The combination of XLIF and TLIF/posterior segmental instrumentation techniques may lead to less blood loss and to radiographic outcomes that are comparable to traditional posterior-only approaches. However, the surgical technique carries significant risks that require further evaluation and proper informed consent.


Neurosurgical Focus | 2010

Intraoperative computed tomography image–guided navigation for posterior thoracolumbar spinal instrumentation in spinal deformity surgery

Matthew J. Tormenti; Dean Kostov; Paul A. Gardner; Adam S. Kanter; Richard M. Spiro; David O. Okonkwo

OBJECT Placement of thoracolumbar pedicle screws in spinal deformity surgery has a reported inaccuracy rate as high as 30%. At present, image-guided navigation systems designed to improve instrumentation accuracy typically use intraoperative fluoroscopy or preoperative CT scans. The authors report the prospective evaluation of the accuracy of posterior thoracolumbar spinal instrumentation using a new intraoperative CT operative suite with an integrated image guidance system. They compare the accuracy of thoracolumbar pedicle screw placement using intraoperative CT image guidance with instrumentation placement utilizing fluoroscopy. METHODS Between December 2007 and July 2008, 12 patients underwent posterior spinal instrumentation for spinal deformity correction using intraoperative CT-based image guidance. An intraoperative CT scan of the sterile surgical field was obtained after decompression and before instrumentation. Instrumentation was placed, and a postinstrumentation CT scan was obtained before wound closure to assess the accuracy of instrumentation placement and the potential need for revision. The accuracy of pedicle screw placement was later reviewed and recorded by independent observers. A comparison group of 14 patients who underwent thoracolumbar instrumentation utilizing fluoroscopy and postoperative CT scanning during the same time period was evaluated and included in this analysis. RESULTS In the intraoperative CT-based image guidance group, a total of 164 thoracolumbar pedicle screws were placed. Two screws were found to have breached the pedicle wall (1.2%). Neither screw was deemed to need revision due to misplacement. In the comparison group, 211 pedicle screws were placed. Postoperative CT scanning revealed that 11 screws (5.2%) had breached the pedicle. One patient in the fluoroscopy group awoke with a radiculopathy attributed to a misplaced screw, which required revision. The difference in accuracy was statistically significant (p = 0.031). CONCLUSIONS Intraoperative CT-based image guidance for placement of thoracolumbar instrumentation has an accuracy that exceeds reported rates with other image guidance systems, such as virtual fluoroscopy and 3D isocentric C-arm-based stereotactic systems. Furthermore, with the use of intraoperative CT scanning, a postinstrumentation CT scan allows the surgeon to evaluate the accuracy of instrumentation before wound closure and revise as appropriate.


Neurosurgical Focus | 2014

Complications in adult spinal deformity surgery: an analysis of minimally invasive, hybrid, and open surgical techniques.

Juan S. Uribe; Armen R. Deukmedjian; Praveen V. Mummaneni; Kai Ming G Fu; Gregory M. Mundis; David O. Okonkwo; Adam S. Kanter; Robert K. Eastlack; Michael Y. Wang; Neel Anand; Richard G. Fessler; Frank La Marca; Paul Park; Virginie Lafage; Vedat Deviren; Shay Bess; Christopher I. Shaffrey

OBJECT It is hypothesized that minimally invasive surgical techniques lead to fewer complications than open surgery for adult spinal deformity (ASD). The goal of this study was to analyze matched patient cohorts in an attempt to isolate the impact of approach on adverse events. METHODS Two multicenter databases queried for patients with ASD treated via surgery and at least 1 year of follow-up revealed 280 patients who had undergone minimally invasive surgery (MIS) or a hybrid procedure (HYB; n = 85) or open surgery (OPEN; n = 195). These patients were divided into 3 separate groups based on the approach performed and were propensity matched for age, preoperative sagittal vertebral axis (SVA), number of levels fused posteriorly, and lumbar coronal Cobb angle (CCA) in an attempt to neutralize these patient variables and to make conclusions based on approach only. Inclusion criteria for both databases were similar, and inclusion criteria specific to this study consisted of an age > 45 years, CCA > 20°, 3 or more levels of fusion, and minimum of 1 year of follow-up. Patients in the OPEN group with a thoracic CCA > 75° were excluded to further ensure a more homogeneous patient population. RESULTS In all, 60 matched patients were available for analysis (MIS = 20, HYB = 20, OPEN = 20). Blood loss was less in the MIS group than in the HYB and OPEN groups, but a significant difference was only found between the MIS and the OPEN group (669 vs 2322 ml, p = 0.001). The MIS and HYB groups had more fused interbody levels (4.5 and 4.1, respectively) than the OPEN group (1.6, p < 0.001). The OPEN group had less operative time than either the MIS or HYB group, but it was only statistically different from the HYB group (367 vs 665 minutes, p < 0.001). There was no significant difference in the duration of hospital stay among the groups. In patients with complete data, the overall complication rate was 45.5% (25 of 55). There was no significant difference in the total complication rate among the MIS, HYB, and OPEN groups (30%, 47%, and 63%, respectively; p = 0.147). No intraoperative complications were reported for the MIS group, 5.3% for the HYB group, and 25% for the OPEN group (p < 0.03). At least one postoperative complication occurred in 30%, 47%, and 50% (p = 0.40) of the MIS, HYB, and OPEN groups, respectively. One major complication occurred in 30%, 47%, and 63% (p = 0.147) of the MIS, HYB, and OPEN groups, respectively. All patients had significant improvement in both the Oswestry Disability Index (ODI) and visual analog scale scores after surgery (p < 0.001), although the MIS group did not have significant improvement in leg pain. The occurrence of complications had no impact on the ODI. CONCLUSIONS Results in this study suggest that the surgical approach may impact complications. The MIS group had significantly fewer intraoperative complications than did either the HYB or OPEN groups. If the goals of ASD surgery can be achieved, consideration should be given to less invasive techniques.


Journal of Neurosurgery | 2015

Comparison of two minimally invasive surgery strategies to treat adult spinal deformity.

Paul Park; Michael Y. Wang; Virginie Lafage; Stacie Nguyen; John E. Ziewacz; David O. Okonkwo; Juan S. Uribe; Robert K. Eastlack; Neel Anand; Raqeeb Haque; Richard G. Fessler; Adam S. Kanter; Vedat Deviren; Frank La Marca; Justin S. Smith; Christopher I. Shaffrey; Gregory M. Mundis; Praveen V. Mummaneni

OBJECT Minimally invasive surgery (MIS) techniques are becoming a more common means of treating adult spinal deformity (ASD). The aim of this study was to compare the hybrid (HYB) surgical approach, involving minimally invasive lateral interbody fusion with open posterior instrumented fusion, to the circumferential MIS (cMIS) approach to treat ASD. METHODS The authors performed a retrospective, multicenter study utilizing data collected in 105 patients with ASD who were treated via MIS techniques. Criteria for inclusion were age older than 45 years, coronal Cobb angle greater than 20°, and a minimum of 1 year of follow-up. Patients were stratified into 2 groups: HYB (n = 62) and cMIS (n = 43). RESULTS The mean age was 60.7 years in the HYB group and 61.0 years in the cMIS group (p = 0.910). A mean of 3.6 interbody fusions were performed in the HYB group compared with a mean of 4.0 interbody fusions in the cMIS group (p = 0.086). Posterior fusion involved a mean of 6.9 levels in the HYB group and a mean of 5.1 levels in the cMIS group (p = 0.003). The mean follow-up was 31.3 months for the HYB group and 38.3 months for the cMIS group. The mean Oswestry Disability Index (ODI) score improved by 30.6 and 25.7, and the mean visual analog scale (VAS) scores for back/leg pain improved by 2.4/2.5 and 3.8/4.2 for the HYB and cMIS groups, respectively. There was no significant difference between groups with regard to ODI or VAS scores. For the HYB group, the lumbar coronal Cobb angle decreased by 13.5°, lumbar lordosis (LL) increased by 8.2°, sagittal vertical axis (SVA) decreased by 2.2 mm, and LL-pelvic incidence (LL-PI) mismatch decreased by 8.6°. For the cMIS group, the lumbar coronal Cobb angle decreased by 10.3°, LL improved by 3.0°, SVA increased by 2.1 mm, and LL-PI decreased by 2.2°. There were no significant differences in these radiographic parameters between groups. The complication rate, however, was higher in the HYB group (55%) than in the cMIS group (33%) (p = 0.024). CONCLUSIONS Both HYB and cMIS approaches resulted in clinical improvement, as evidenced by decreased ODI and VAS pain scores. While there was no significant difference in degree of radiographic correction between groups, the HYB group had greater absolute improvement in degree of lumbar coronal Cobb angle correction, increased LL, decreased SVA, and decreased LL-PI. The complication rate, however, was higher with the HYB approach than with the cMIS approach.


Journal of Neurosurgery | 2012

Perioperative surgical complications of transforaminal lumbar interbody fusion: a single-center experience

Matthew J. Tormenti; Matthew B. Maserati; Christopher M. Bonfield; Peter C. Gerszten; John Moossy; Adam S. Kanter; Richard M. Spiro; David O. Okonkwo

OBJECT Since its original description in 1982, transforaminal lumbar interbody fusion (TLIF) has grown in popularity as a means for achieving circumferential fusion. The authors sought to define the perioperative complication rates of the TLIF procedure at a large academic medical center. METHODS For all eligible patients from a consecutive series of 531 TLIF procedures, the institutions complication database and the medical record were reviewed to identify complications. Medical, nonprocedure-related complications such as myocardial infarction and pulmonary embolism were excluded due to inconsistency in the recording of these complications in the database. Rates were calculated for each type of complication, and subgroup analysis was performed to investigate the effect of previous lumbar surgery, and of multilevel versus single-level interbody fusion on complication rates. Odds ratios were calculated and evaluated using chi-square analysis. RESULTS Five hundred thirty-one patients underwent a TLIF procedure during the study period. Two hundred forty-four patients (46%) had undergone a previous lumbar operation. Interbody fusion was performed at 1 level in 317 patients, at 2 levels in 188 patients, at 3 levels in 24 patients, and at 4 levels in 2 patients. One hundred thirty-five patients (25.4%) had at least one procedure-related complication. The most common complications were durotomy (14.3% of patients) and infection (3.8% of patients). Symptomatic screw misplacement (2.1% of patients) and interbody cage migration (1.8% of patients) were less common complications. The overall complication rate was greater in those patients who had undergone a previous operation (OR 1.75, 95% CI 1.18-2.59; p < 0.01) and in those who had multilevel surgery (OR 1.54, 95 % CI 1.04-2.28; p = 0.03), and the incidence of durotomy was higher in patients who had a previous operation (OR 1.75, 95% CI 1.07-2.87; p = 0.03). These differences were statistically significant. Durotomy also occurred more frequently in patients who had multilevel interbody fusion (OR 1.49, 95% CI 0.92-2.43; p = 0.13). A trend toward higher infection rates in those patients who underwent multilevel interbody fusion was observed (OR 1.5, 95% CI 0.62-3.68; p = 0.49), but this was not statistically significant. Infection rates did not differ between revision and first-time surgeries. CONCLUSIONS Transforaminal lumbar interbody fusion has gained widespread popularity as a procedure for achieving arthrodesis in the lumbar spine. Complications occurred more often in patients undergoing revision surgery or multilevel interbody fusion. Durotomy and infection were the most common complications in this series.


Neurosurgical Focus | 2014

Less invasive surgery for treating adult spinal deformities: ceiling effects for deformity correction with 3 different techniques

Michael Y. Wang; Praveen V. Mummaneni; Kai Ming G Fu; Neel Anand; David O. Okonkwo; Adam S. Kanter; Frank La Marca; Richard G. Fessler; Juan S. Uribe; Christopher I. Shaffrey; Virginie Lafage; Raqeeb Haque; Vedat Deviren; Gregory M. Mundis

OBJECT Minimally invasive surgery (MIS) options for the treatment of adult spinal deformity (ASD) have advanced significantly over the past decade. However, a wide array of options have been described as being MIS or less invasive. In this study the authors investigated a multiinstitutional cohort of patients with ASD who were treated with less invasive methods to determine the extent of deformity correction achieved. METHODS This study was a retrospective review of multicenter prospectively collected data in 85 consecutive patients with ASD undergoing MIS surgery. Inclusion criteria were as follows: age older than 45 years; minimum 20° coronal lumbar Cobb angle; and 1 year of follow-up. Procedures were classified as follows: 1) stand-alone (n = 7); 2) circumferential MIS (n = 43); or 3) hybrid (n = 35). RESULTS An average of 4.2 discs (range 3-7) were fused, with a mean follow-up duration of 26.1 months in this study. For the stand-alone group the preoperative Cobb range was 22°-51°, with 57% greater than 30° and 28.6% greater than 50°. The mean Cobb angle improved from 35.7° to 30°. A ceiling effect of 23° for curve correction was observed, regardless of preoperative curve severity. For the circumferential MIS group the preoperative Cobb range was 19°-62°, with 44% greater than 30° and 5% greater than 50°. The mean Cobb angle improved from 32° to 12°. A ceiling effect of 34° for curve correction was observed. For the hybrid group the preoperative Cobb range was 23°-82°, with 74% greater than 30° and 23% greater than 50°. The mean Cobb angle improved from 43° to 15°. A ceiling effect of 55° for curve correction was observed. CONCLUSIONS Specific procedures for treating ASD have particular limitations for scoliotic curve correction. Less invasive techniques were associated with a reduced ability to straighten the spine, particularly with advanced curves. These data can guide preoperative technique selection when treating patients with ASD.


Neurosurgical Focus | 2014

Radiographic and clinical outcomes following combined lateral lumbar interbody fusion and posterior segmental stabilization in patients with adult degenerative scoliosis

Zachary J. Tempel; Gurpreet S. Gandhoke; Christopher M. Bonfield; David O. Okonkwo; Adam S. Kanter

OBJECT A hybrid approach of minimally invasive lateral lumbar interbody fusion (LLIF) followed by supplementary open posterior segmental instrumented fusion (PSIF) has shown promising early results in the treatment of adult degenerative scoliosis. Studies assessing the impact of this combined approach on correction of segmental and regional coronal angulation, sagittal realignment, maximum Cobb angle, restoration of lumbar lordosis, and clinical outcomes are needed. The authors report their results of this approach for correction of adult degenerative scoliosis. METHODS Twenty-six patients underwent combined LLIF and PSIF in a staged fashion. The patient population consisted of 21 women and 5 men. Ages ranged from 40 to 77 years old. Radiographic measurements including coronal angulation, pelvic incidence, lumbar lordosis, and sagittal vertical axis were taken preoperatively and 1 year postoperatively in all patients. Concurrently, the visual analog score (VAS) for back and leg pain, the Oswestry Disability Index (ODI), and Short Form-36 (SF-36) Physical Component Summary (PCS) and Mental Component Summary (MCS) scores were used to assess clinical outcomes in 19 patients. RESULTS At 1-year follow-up, all patients who underwent combined LLIF and PSIF achieved statistically significant mean improvement in regional coronal angles (from 14.9° to 5.8°, p < 0.01) and segmental coronal angulation at all operative levels (p < 0.01). The maximum Cobb angle was significantly reduced postoperatively (from 41.1° to 15.1°, p < 0.05) and was maintained at follow-up (12.0°, p < 0.05). The mean lumbar lordosis-pelvic incidence mismatch was significantly improved postoperatively (from 15.0° to 6.92°, p < 0.05). Although regional lumbar lordosis improved (from 43.0° to 48.8°), it failed to reach statistical significance (p = 0.06). The mean sagittal vertical axis was significantly improved postoperatively (from 59.5 mm to 34.2 mm, p < 0.01). The following scores improved significantly after surgery: VAS for back pain (from 7.5 to 4.3, p < 0.01) and leg pain (from 5.8 to 3.1, p < 0.01), ODI (from 48 to 38, p < 0.01), and PCS (from 27.5 to 35.0, p = 0.01); the MCS score did not improve significantly (from 43.2 to 45.5, p = 0.37). There were 3 major and 10 minor complications. CONCLUSIONS A hybrid approach of minimally invasive LLIF and open PSIF is an effective means of achieving correction of both coronal and sagittal deformity, resulting in improvement of quality of life in patients with adult degenerative scoliosis.


Neurosurgery | 2011

Management and implications of intraoperative cerebrospinal fluid leak in transnasoseptal transsphenoidal microsurgery.

George J. Kaptain; Adam S. Kanter; David K. Hamilton; Edward R. Laws

BACKGROUND: Nonvascularized autologous grafts used for sellar reconstruction in transseptal transsphenoidal surgery are commonly applied in the setting of intraoperative cerebrospinal fluid (CSF) leak and have been shown to be effective in preventing postoperative complications. OBJECTIVE: To assess the clinical implications of intraoperative CSF leak, to evaluate the efficacy of repair techniques using autologous nonvascularized materials, and to analyze the nature and timing of failures. These data may serve as a basis for assessing the utility of innovations in techniques and implant technologies. METHODS: A review was conducted of 257 consecutive patients who underwent transsphenoidal surgery that was complicated by intraoperative CSF leak from 1995 to 2001. Sellar reconstruction was performed with autologous materials except in reoperations in which septal materials were not available; lumbar drain catheters were used selectively. RESULTS: Six of the 257 patients (2.3%) developed postoperative CSF rhinorrhea occurring an average of 6.6 days after surgery. All 6 underwent reoperation, with 5 of 6 managed with operative lumbar drainage. Bacterial meningitis developed in 3 of 257 (1.2%). Worsening in visual function occurred in 8 of 257 (3.1%), with 1 of 257 (0.3%) suffering from permanent worsening of visual function. Additional surgery was performed in 2 of these patients, resulting in successful reversal of visual loss. Ten of 257 patients (3.9%) developed a subcutaneous hematoma at the fat graft harvest site, with 1 patient requiring surgical re-exploration. CONCLUSIONS: Watertight closure of the sella with autologous materials is effective in preventing postoperative rhinorrhea. Complications specific to the technique include graft site hematoma (4%) and rare instances of visual loss caused by optic nerve compression.


Neurosurgery | 2016

Does Minimally Invasive Percutaneous Posterior Instrumentation Reduce Risk of Proximal Junctional Kyphosis in Adult Spinal Deformity Surgery? A Propensity-Matched Cohort Analysis.

Praveen V. Mummaneni; Paul Park; Kai Ming Fu; Michael Y. Wang; Stacie Nguyen; Virginie Lafage; Juan S. Uribe; John E. Ziewacz; Jamie S. Terran; David O. Okonkwo; Neel Anand; Richard G. Fessler; Adam S. Kanter; Frank LaMarca; Vedat Deviren; R. Shay Bess; Frank J. Schwab; Justin S. Smith; Behrooz A. Akbarnia; Gregory M. Mundis; Christopher I. Shaffrey

BACKGROUND Proximal junctional kyphosis (PJK) is a known complication after spinal deformity surgery. One potential cause is disruption of posterior muscular tension band during pedicle screw placement. OBJECTIVE To investigate the effect of minimally invasive surgery (MIS) on PJK. METHODS A multicenter database of patients who underwent deformity surgery was propensity matched for pelvic incidence (PI) to lumbar lordosis (LL) mismatch and change in LL. Radiographic PJK was defined as proximal junctional angle >10°. Sixty-eight patients made up the circumferential MIS (cMIS) group, and 68 were in the hybrid (HYB) surgery group (open screw placement). RESULTS Preoperatively, there was no difference in age, body mass index, PI-LL mismatch, or sagittal vertical axis. The mean number of levels treated posteriorly was 4.7 for cMIS and 8.2 for HYB (P < .001). Both had improved LL and PI-LL mismatch postoperatively. Sagittal vertical axis remained physiological for the cMIS and HYB groups. Oswestry Disability Index scores were significantly improved in both groups. Radiographic PJK developed in 31.3% of the cMIS and 52.9% of the HYB group (P = .01). Reoperation for PJK was 4.5% for the cMIS and 10.3% for the HYB group (P = .20). Subgroup analysis for patients undergoing similar levels of posterior instrumentation in the cMIS and HYB groups found a PJK rate of 48.1% and 53.8% (P = .68) and a reoperation rate of 11.1% and 19.2%, respectively (P = .41). Mean follow-up was 32.8 months. CONCLUSION Overall rates of radiographic PJK and reoperation for PJK were not significantly decreased with MIS pedicle screw placement. However, a larger comparative study is needed to confirm that MIS pedicle screw placement does not affect PJK.


Journal of Clinical Neuroscience | 2015

Stand-alone minimally invasive lateral lumbar interbody fusion: Multicenter clinical outcomes

Amir Ahmadian; Konrad Bach; Bryan D. Bolinger; Gregory M. Malham; David O. Okonkwo; Adam S. Kanter; Juan S. Uribe

Stand-alone minimally invasive lateral transpsoas interbody fusion (MIS-LIF), without posterior instrumentation, is feasible because the technique does not necessitate the disruption of the stabilizing elements. The objectives of this study are to evaluate the efficacy and clinical outcomes of patients who underwent stand-alone lateral interbody fusion. A multicenter chart review was conducted to identify patients who underwent stand-alone MIS-LIF between 2008 and 2012. Patients were classified by spinal pathology (degenerative disc disease [DDD], spondylolisthesis [SL] and adult degenerative scoliosis [ADS]). Routine clinical follow-up was scheduled at 3, 6, and12 months. Outcome measures included hospital length of stay, fusion rates, neurologic complications, integrity of construct and clinical outcome questionnaires (Visual Analog Scale [VAS] and Oswestry Disability Index [ODI]). A total of 59 patients met the inclusion criteria. The average age was 60 years (range 31-86 years). Spinal pathologies treated were DDD in 37 (63%), SL in four (7%) and ADS in 18 (30%) patients. Fusion rate was 93% of patients (95% of levels) at 12 months. Two patients required re-operation. Mean hospital stay and follow-up were 3.3days (range 1-10) and 14.6 months, respectively. The mean preoperative VAS and ODI were 69.1 and 51.8, respectively. VAS improved to 37.8 (p<0.0005). ODI improved to 31.8 (p<0.0005). Seventy percent of patients had grade 0 subsidence while 30% had grade I and grade II subsidence. Stand-alone MIS-LIF is viable option in a carefully selected patient population for both single and multilevel disease and shows significant improvement in health related quality of life.

Collaboration


Dive into the Adam S. Kanter's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Juan S. Uribe

University of South Florida

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Neel Anand

Cedars-Sinai Medical Center

View shared research outputs
Top Co-Authors

Avatar

Paul Park

University of Michigan

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Richard G. Fessler

Rush University Medical Center

View shared research outputs
Researchain Logo
Decentralizing Knowledge