Adam Wax
Duke University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Adam Wax.
Biophysical Journal | 2002
Adam Wax; Changhuei Yang; Vadim Backman; Kamran Badizadegan; Charles W. Boone; Ramachandra R. Dasari; Michael S. Feld
We measure the organization and substructure of HT29 epithelial cells in a monolayer using angle-resolved low-coherence interferometry. This new technique probes cellular structure by measuring scattered light, as in flow cytometry, but offers an advantage in that the structure can be examined in situ, avoiding the need to disrupt the cell monolayer. We determine the size distribution of the cell nuclei by fitting measured light-scattering spectra to the predictions of Mie theory. In addition, we obtain information about the cellular organization and substructure by examining the spatial correlations within the monolayer. A remarkable finding is that the spatial correlations over small length scales take the form of an inverse power law, indicating the fractal nature of the packing of the subcellular structures. We also identify spatial correlations on a scale large compared with the size of a cell, indicating an overlying order within the monolayer.
ACS Nano | 2009
Greg Nusz; Adam C. Curry; Stella M. Marinakos; Adam Wax; Ashutosh Chilkoti
We present the development of an analytical model that can be used for the rational design of a biosensor based on shifts in the local surface plasmon resonance (LSPR) of individual gold nanoparticles. The model relates the peak wavelength of light scattered by an individual plasmonic nanoparticle to the number of bound analyte molecules and provides an analytical formulation that predicts relevant figures-of-merit of the sensor such as the molecular detection limit (MDL) and dynamic range as a function of nanoparticle geometry and detection system parameters. The model calculates LSPR shifts for individual molecules bound by a nanorod, so that the MDL is defined as the smallest number of bound molecules that is measurable by the system, and the dynamic range is defined as the maximum number of molecules that can be detected by a single nanorod. This model is useful because it will allow a priori design of an LSPR sensor with figures-of-merit that can be optimized for the target analyte. This model was used to design an LSPR sensor based on biotin-functionalized gold nanorods that offers the lowest MDL for this class of sensors. The model predicts a MDL of 18 streptavidin molecules for this sensor, which is in good agreement with experiments and estimates. Further, we discuss how the model can be utilized to guide the development of future generations of LSPR biosensors.
Optics Express | 2003
John W. Pyhtila; Robert N. Graf; Adam Wax
We outline the process for determining the morphology of subsurface epithelial cell nuclei using depth-resolved light scattering measurements. The measurements are accomplished using a second generation angle-resolved low coherence interferometry system. The new system greatly improves data acquisition and analysis times compared to the initial prototype system. The calibration of the new system is demonstrated in scattering studies to determine the size distribution of polystyrene microspheres in a turbid sample. The process for determining the size of cell nuclei is discussed by analyzing measurements of basal cells in a sub-surface layer of intact, unstained epithelial tissue.
Optics Letters | 2001
Changhuei Yang; Adam Wax; Mariah S. Hahn; Kamran Badizadegan; Ramachandra R. Dasari; Michael S. Feld
We report a highly sensitive means of measuring cellular dynamics with a novel interferometer that can measure motional phase changes. The system is based on a modified Michelson interferometer with a composite laser beam of 1550-nm low-coherence light and 775-nm CW light. The sample is prepared on a coverslip that is highly reflective at 775 nm. By referencing the heterodyne phase of the 1550-nm light reflected from the sample to that of the 775-nm light reflected from the coverslip, small motions in the sample are detected, and motional artifacts from vibrations in the interferometer are completely eliminated. We demonstrate that the system is sensitive to motions as small as 3.6 nm and velocities as small as 1 nm/s. Using the instrument, we study transient volume changes of a few (approximately three) cells in a monolayer immersed in weakly hypotonic and hypertonic solutions.
Optics Letters | 2000
Changhuei Yang; Adam Wax; Irene Georgakoudi; Eugene B. Hanlon; Kamran Badizadegan; Ramachandra R. Dasari; Michael S. Feld
We describe a new scanning microscopy technique, phase-dispersion microscopy (PDM). The technique is based on measuring the phase difference between the fundamental and the second-harmonic light in a novel interferometer. PDM is highly sensitive to subtle refractive-index differences that are due to dispersion (differential optical path sensitivity, 5 nm). We apply PDM to measure minute amounts of DNA in solution and to study biological tissue sections. We demonstrate that PDM performs better than conventional phase-contrast microscopy in imaging dispersive and weakly scattering samples.
Nano Letters | 2008
Melissa C. Skala; Matthew J. Crow; Adam Wax; Joseph A. Izatt
Molecular imaging is a powerful tool for investigating disease processes and potential therapies in both in vivo and in vitro systems. However, high resolution molecular imaging has been limited to relatively shallow penetration depths that can be accessed with microscopy. Optical coherence tomography (OCT) is an optical analogue to ultrasound with relatively good penetration depth (1-2 mm) and resolution (approximately 1-10 microm). We have developed and characterized photothermal OCT as a molecular contrast mechanism that allows for high resolution molecular imaging at deeper penetration depths than microscopy. Our photothermal system consists of an amplitude-modulated heating beam that spatially overlaps with the focused spot of the sample arm of a spectral-domain OCT microscope. Validation experiments in tissuelike phantoms containing gold nanospheres that absorb at 532 nm revealed a sensitivity of 14 ppm nanospheres (weight/weight) in a tissuelike environment. The nanospheres were then conjugated to anti-EGFR, and molecular targeting was confirmed in cells that overexpress EGFR (MDA-MB-468) and cells that express low levels of EGFR (MDA-MB-435). Molecular imaging in three-dimensional tissue constructs was confirmed with a significantly lower photothermal signal (p<0.0001) from the constructs composed of cells that express low levels of EGFR compared to the overexpressing cell constructs (300% signal increase). This technique could potentially augment confocal and multiphoton microscopy as a method for deep-tissue, depth-resolved molecular imaging with relatively high resolution and target sensitivity, without photobleaching or cytotoxicity.
Optics Express | 2004
John W. Pyhtila; Adam Wax
We present a novel angle-resolved low coherence interferometry scheme for rapid measurement of depth-resolved angular scattering distributions to enable determination of scatterer size via elastic scattering properties. Depth resolution is achieved using a superluminescent diode in a modified Mach-Zehnder interferometer with the mixed signal and reference fields dispersed by an imaging spectrograph. The spectrograph slit is located in a Fourier transform plane of the scattering sample, enabling angle-resolved measurements over a 0.21 radian range. The capabilities of the new technique are demonstrated by recording the distribution of light scattered by a sub-surface layer of polystyrene microspheres in 40 milliseconds. The data are used to determine the microsphere size with good accuracy. Future clinical application to measuring the size of cell nuclei in living epithelial tissues using backscattered light is discussed.
IEEE Journal of Selected Topics in Quantum Electronics | 2001
Vadim Backman; Venkatesh Gopal; Maxim Kalashnikov; Kamran Badizadegan; Rajan Gurjar; Adam Wax; Irene Georgakoudi; Markus G. Mueller; Charles W. Boone; Ramachandra R. Dasari; Michael S. Feld
We present a novel instrument for imaging the angular distributions of light backscattered by biological cells and tissues. The intensities in different regions of the image are due to scatterers of different sizes. We exploit this to study scattering from particles smaller than the wavelength of light used, even when they are mixed with larger particles. We show that the scattering from subcellular structure in both normal and cancerous human cells is best fitted to inverse power-law distributions for the sizes of the scattering objects, and propose that the distribution of scattering objects may be different in normal versus cancerous cells.
Optics Letters | 2009
Natan T. Shaked; Matthew T. Rinehart; Adam Wax
We introduce and experimentally demonstrate a fast and accurate method for quantitative imaging of the dynamics of live biological cells. Using a dual-channel interferometric setup, two phase-shifted interferograms of nearly transparent biological samples are acquired in a single digital camera exposure and digitally processed into the phase profile of the sample. Since two interferograms of the same sample are acquired simultaneously, most of the common phase noise is eliminated, enabling the visualization of millisecond-scale dynamic biological phenomena with subnanometer optical path length temporal stability.
Optics Letters | 2001
Changhuei Yang; Adam Wax; Ramachandra R. Dasari; Michael S. Feld
We report on phase-dispersion optical tomography, a new imaging technique based on phase measurements using low-coherence interferometry. The technique simultaneously probes the target with fundamental and second-harmonic light and interferometrically measures the relative phase shift of the backscattered light fields. This phase change can arise either from reflection at an interface within a sample or from bulk refraction. We show that this highly sensitive (~5 degrees ) phase technique can complement optical coherence tomography, which measures electric field amplitude, by revealing otherwise undetectable dispersive variations in the sample.