Adeline Daireaux
International Bureau of Weights and Measures
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Adeline Daireaux.
Analytical Chemistry | 2013
Steven A. Westwood; Tiphaine Choteau; Adeline Daireaux; Ralf D. Josephs; Robert Wielgosz
A mass balance method is described for determining the mass fraction of the main component of a high purity organic material. The resulting assigned value is established to be traceable to the SI and can be determined with a small associated measurement uncertainty. Pure organic materials with values and uncertainties determined in this way are necessary as primary calibrators of reference measurement systems in order to underpin the metrological traceability of routine measurement results. The method has been applied to materials in which the main components were respectively theophylline, digoxin, 17β-estradiol, and aldrin. Its performance has been validated in international comparisons coordinated by the BIPM and is in principle applicable to a wide structural range of stable, nonvolatile organic compounds. It has been successfully applied to mass fraction assignments when the main component is present in the range of (950-1000) mg/g and can achieve associated standard uncertainties ranging from 0.5 mg/g (for high purity materials or those containing well-characterized, stable minor components) to 2 mg/g (materials with a significant number or variety of impurities). It is in principle equally applicable to materials with a smaller mass fraction content of the main component.
Journal of Chromatography A | 2010
Ralf D. Josephs; Adeline Daireaux; Steven A. Westwood; Robert Wielgosz
A high performance liquid chromatography-hybrid tandem mass spectrometry (LC-MS(n)) method utilising electrospray ionisation has been developed and implemented for the simultaneous determination of several cardiac glycosides (CGs) as well as their corresponding aglycones formed by and extracted from herbaceous plants of the genus Digitalis. The method has been validated in-house and its performance characteristics (linearity, repeatability, limits of detection, etc.) were assessed for use in the quantification of CGs and their corresponding aglycones. LODs from 38 to 936pgg(-1) in solution, corresponding to mass fraction impurity levels from 0.0009 (or 0.00008%) to 0.019mgg(-1) (or 0.0019%) detectable in the pure materials have been realized. Moreover, the method was used to characterize and to determine the inherent CG impurities in batches of the therapeutic monitored drug digoxin which served as candidate reference material for an organic purity assessment inter-laboratory study (CCQM-P20.f) organised by the BIPM Chemistry Section and carried out within the framework of the Organic Analysis Working Group (OAWG) of the Consultative Committee for Amount of Substance - Metrology in Chemistry (CCQM). Digoxin was selected from materials required for the establishment of reference measurement systems for clinical chemistry and laboratory medicine.
Metrologia | 2012
Steven Westwood; Ralf D. Josephs; Tiphaine Choteau; Adeline Daireaux; Charline Mesquida; Robert Wielgosz; Adriana Rosso; Mariana Ruiz de Arechavaleta; Stephen Davies; Hongjie Wang; Eliane Cristina Pires do Rego; Janaína Marques Rodrigues; Evelyn de Freitas Guimarães; Marcus Vinicius Barreto Sousa; Tânia Monteiro; Laura Alves das Neves Valente; Fernando Gustavo Marques Violante; Renato Rubim Ribeiro Almeida; Maria Cristina Baptista Quaresma; Raquel Nogueira; Anthony Windust; Xinhua Dai; Xiaomin Li; Wei Zhang; Ming Li; Mingwu Shao; Chao Wei; Siu-kay Wong; Julie Cabillic; Fanny Gantois
Under the auspices of the Organic Analysis Working Group (OAWG) of the Comit? Consultatif pour la Quantit? de Mati?re (CCQM) a key comparison, CCQM K55.b, was coordinated by the Bureau International des Poids et Mesures (BIPM) in 2010/2011. Nineteen national measurement institutes and the BIPM participated. Participants were required to assign the mass fraction of aldrin present as the main component in the comparison sample for CCQM-K55.b which consisted of technical grade aldrin obtained from the National Measurement Institute Australia that had been subject to serial recrystallization and drying prior to sub-division into the units supplied for the comparison. Aldrin was selected to be representative of the performance of a laboratorys measurement capability for the purity assignment of organic compounds of medium structural complexity [molar mass range 300 Da to 500 Da] and low polarity (pKOW < ?2) for which related structure impurities can be quantified by capillary gas phase chromatography (GC). The key comparison reference value (KCRV) for the aldrin content of the material was 950.8 mg/g with a combined standard uncertainty of 0.85 mg/g. The KCRV was assigned by combination of KCRVs assigned by consensus from participant results for each orthogonal impurity class. The relative expanded uncertainties reported by laboratories having results consistent with the KCRV ranged from 0.3% to 0.6% using a mass balance approach and 0.5% to 1% using a qNMR method. The major analytical challenge posed by the material proved to be the detection and quantification of a significant amount of oligomeric organic material within the sample and most participants relying on a mass balance approach displayed a positive bias relative to the KCRV (overestimation of aldrin content) in excess of 10 mg/g due to not having adequate procedures in place to detect and quantify the non-volatile content?specifically the non-volatile organics content?of the comparison sample. There was in general excellent agreement between participants in the identification and the quantification of the total and individual related structure impurities, water content and the residual solvent content of the sample. The comparison demonstrated the utility of 1H NMR as an independent method for quantitative analysis of high purity compounds. In discussion of the participant results it was noted that while several had access to qNMR estimates for the aldrin content that were inconsistent with their mass balance determination they decided to accept the mass balance result and assumed a hidden bias in their NMR data. By contrast, laboratories that placed greater confidence in their qNMR result were able to resolve the discrepancy through additional studies that provided evidence of the presence of non-volatile organic impurity at the requisite level to bring their mass balance and qNMR estimates into agreement. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Metrologia | 2009
Steven Westwood; Ralf D. Josephs; Adeline Daireaux; Robert Wielgosz; Stephen Davies; M Kang; H Ting; R Phillip; F Malz; Y Shimizu; E Frias; M Pérez; P Apps; M Fernandes-Whaley; B de Vos; K Wiangnon; N Ruangrittinon; S Wood; David L. Duewer; Michele M. Schantz; Mary Bedner; Diane K. Hancock; J Esker
Under the auspices of the Organic Analysis Working Group (OAWG) of the Comit? Consultatif pour la Quantit? de Mati?re (CCQM) a laboratory comparison, CCQM-P20.e, was coordinated by the Bureau International de Poids et Mesures (BIPM) in 2006/2007. Nine national measurement institutes, two expert laboratories and the BIPM participated in the comparison. Participants were required to assign the mass fraction of theophylline present as the main component in two separate study samples (CCQM-P20.e.1 and CCQM-P20.e.2). CCQM-P20.e.1 consisted of a high-purity theophylline material obtained from a commercial supplier. CCQM-P20.e.2 consisted of theophylline to which known amounts of the related structure compounds theobromine and caffeine were added in a homogenous, gravimetrically controlled fashion. For the CCQM-P20.e.2 sample it was possible to estimate gravimetric reference values both for the main component and for the two spiked impurities. In addition to assigning the mass fraction content of theophylline for both materials, participants were requested but not obliged to provide mass fraction estimates for the minor components they identified in each sample. The results reported by the study participants for the mass fraction content of theophylline in both materials showed good levels of agreement both with each other and with the gravimetric reference value assigned to the CCQM-P20.e.2 material. There was also satisfactory agreement overall, albeit at higher levels of uncertainty, in the quantification data reported for the minor components present in both samples. In the few cases where a significant deviation was observed from the consensus values reported by the comparison participants or gravimetric reference values where these where available, they appeared to arise from the use of non-optimal chromatographic separation conditions. The results demonstrate the feasibility for laboratories to assign mass fraction content with associated absolute expanded uncertainties in the range 0.05% to 0.5% for solid organic compounds of high purity (mass fraction of main component >995 mg/g) and in the range 0.1% to 1% for compounds of lower purity (mass fraction of main component >980 mg/g). Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCQM Working Group on Organic Analysis.
Metrologia | 2014
Steven Westwood; Ralf D. Josephs; Tiphaine Choteau; Adeline Daireaux; Robert Wielgosz; Stephen Davies; Michael Moad; Benjamin Chan; Amalia Muñoz; Patrick Conneely; Marina Ricci; Eliane Cristina Pires do Rego; Bruno Garrido; Fernando Gustavo Marques Violante; Anthony Windust; Xinhua Dai; Ting Huang; Wei Zhang; Fuhai Su; Can Quan; Haifeng Wang; Man-fung Lo; Wai-fun Wong; Fanny Gantois; Béatrice Lalerle; Ute Dorgerloh; Matthias Koch; Urszula-Anna Klyk-Seitz; Dietmar Pfeifer; Rosemarie Philipp
Under the auspices of the Organic Analysis Working Group (OAWG) of the Comit? Consultatif pour la Quantit? de Mati?re (CCQM) a key comparison, CCQM K55.c, was coordinated by the Bureau International des Poids et Mesures (BIPM) in 2012. Twenty National Measurement Institutes or Designated Institutes and the BIPM participated. Participants were required to assign the mass fraction of valine present as the main component in the comparison sample for CCQM-K55.c. The comparison samples were prepared from analytical grade L-valine purchased from a commercial supplier and used as provided without further treatment or purification. Valine was selected to be representative of the performance of a laboratorys measurement capability for the purity assignment of organic compounds of low structural complexity [molecular weight range 100?300] and high polarity (pKOW > ?2). The KCRV for the valine content of the material was 992.0 mg/g with a combined standard uncertainty of 0.3 mg/g. The key comparison reference value (KCRV) was assigned by combination of KCRVs assigned from participant results for each orthogonal impurity class. The relative expanded uncertainties reported by laboratories having results consistent with the KCRV ranged from 1 mg/g to 6 mg/g when using mass balance based approaches alone, 2 mg/g to 7 mg/g using quantitative 1H NMR (qNMR) based approaches and from 1 mg/g to 2.5 mg/g when a result obtained by a mass balance method was combined with a separate qNMR result. The material provided several analytical challenges. In addition to the need to identify and quantify various related amino acid impurities including leucine, isoleucine, alanine and ?-amino butyrate, care was required to select appropriate conditions for performing Karl Fischer titration assay for water content to avoid bias due to in situ formation of water by self-condensation under the assay conditions. It also proved to be a challenging compound for purity assignment by qNMR techniques. There was overall excellent agreement between participants in the identification and the quantification of the total and individual related structure impurities, water content, residual solvent and total non-volatile content of the sample. Appropriate technical justifications were developed to rationalise observed discrepancies in the limited cases where methodology differences led to inconsistent results. The comparison demonstrated that to perform a qNMR purity assignment the selection of appropriate parameters and an understanding of their potential influence on the assigned value is critical for reliable implementation of the method, particularly when one or more of the peaks to be quantified consist of complex multiplet signals. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Metrologia | 2011
Steven Westwood; Ralf D. Josephs; Tiphaine Choteau; C Mesquida; Adeline Daireaux; Robert Wielgosz; Stephen Davies; Anthony Windust; Ma Kang; H Ting; K Kato; E Frias; M Pérez; P Apps; Maria Fernandes-Whaley; K Wiangnon; N Ruangrittinon; S Wood; Thierry LeGoff; David L. Duewer; Michele M. Schantz; L Siekmann; J Esker
Under the auspices of the Organic Analysis Working Group (OAWG) of the Comite Consultatif pour la Quantite de Matiere (CCQM) a laboratory comparison, CCQM-P20.f, was coordinated by the Bureau International des Poids et Mesures (BIPM) in 2007/2008. Nine national measurement institutes, four expert laboratories and the BIPM participated in the comparison. Participants were required to assign the mass fraction of digoxin present as the main component in the comparison sample (CCQM-P20.f) which consisted of digoxin material obtained from a commercial supplier stated to comply with USP requirements. In addition to assigning the mass fraction content of digoxin for the material, participants were requested, but not obliged, to provide mass fraction estimates for the minor components they identified in each sample. In contrast with the previous round of the CCQM-P20 series, in which the mass fraction content of theophylline in two comparison samples (CCQM-P20.e.1 and CCQM-P20.e.2) was determined, a wider range of results were reported for the mass fraction content of digoxin in the CCQM-P20.f comparison. A minority of participants did not appear to use conditions capable of fully resolving and/or quantifying the major related structure impurities present in the comparison sample. Among those that did achieve suitable separations, there was further variation in their reported quantifications of the individual and total related substance content which reflected in part the limited availability of reference standards for these materials and the resulting assumptions that had to be made regarding the structure and response factors relative to digoxin for each individual impurity. This was particularly relevant because of the span of molecular masses of the impurities present in the sample, which ranged from aglycones to glycones with tetrameric carbohydrate chains, relative to that of digoxin. A significant additional factor also contributed to the observed variation of results. Unlike the CCQM-P20.e samples, in which the major impurities were solely related structure organic compounds, the CCQM-P20.f study material contained significant levels of residual organic solvents (ethanol, dichloromethane and to a lesser extent toluene). The majority of participants failed to detect and allow for the presence of this class of impurity, introducing a bias towards overestimation of digoxin content in most of the individual results. However, the uncertainty budgets produced by several participants were sufficiently conservative such that their reported results were nevertheless consistent with the reference value for digoxin content assigned using a consensus mass balance approach. The results of the comparison reinforce the conclusion from previous rounds of the CCQM-P20 study that care in developing and validating the suitability of the chromatographic separation method used to resolve the main component from the related structure impurities present is essential to obtaining reliable, comparable results when using the mass balance approach to estimate purity. This specific comparison has demonstrated that, in addition to developing an appropriate chromatographic separation, it is also important to use complementary techniques capable of detecting all potential orthogonal classes of impurities if it is desired to demonstrate a general capability to assign purity with a small (<0.2% relative) standard uncertainty. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCQM OAWG.
Analytical and Bioanalytical Chemistry | 2015
Ralf D. Josephs; Adeline Daireaux; Tiphaine Choteau; Steven A. Westwood; Robert Wielgosz
AbstractA normal phase-liquid chromatography-hybrid tandem mass spectrometry (NP-LC-MS/MS) method utilizing atmospheric pressure photoionization (APPI) without dopant has been developed and implemented for the simultaneous determination of several estrogenic steroid hormones. The combination of both NP-LC and APPI-MS/MS tolerates the use of solvents that have the advantages of being self-doping for APPI and, at the same time, inhibit the in situ formation of estrogen dimers as frequently observed for conventional reversed phase (RP)-LC methods. The NP-LC-APPI-MS/MS method has been validated in-house, and its performance characteristics (linearity, repeatability, limits of detection, etc.) were assessed for use in the quantification of estrogens. Moreover, the method was used to characterize and determine the inherent related structure impurities in batches of β-estradiol, required for the establishment of reference measurement systems for clinical chemistry and laboratory medicine, which served as candidate reference material for an organic purity assessment interlaboratory study (CCQM-K55.a) organized by the International Bureau of Weights and Measures (BIPM) Chemistry Department and carried out within the framework of the Organic Analysis Working Group (OAWG) of the Consultative Committee for Amount of Substance—Metrology in Chemistry (CCQM). Graphical abstractFull-scale and enlarged overlaid SRM chromatograms of three transitions for ten estrogenic steroid hormones for the impurity quantification of a βE2 material
Metrologia | 2012
Steven Westwood; Ralf D. Josephs; Adeline Daireaux; Robert Wielgosz; Stephen Davies; Hongjie Wang; Jainana Rodrigues; Wagner Wollinger; Anthony Windust; Ma Kang; Su Fuhai; Rosemarie Philipp; Paul Kuhlich; Siu-kay Wong; Yoshitaka Shimizu; Melina Pérez; Marco Avila; Maria Fernandes-Whaley; D Prevoo; J de Vos; Ria Visser; Marcellé Archer; Thierry LeGoff; Steve Wood; Dan Bearden; Mary Bedner; Arezue F. B. Boroujerdi; David L. Duewer; Diane K. Hancock; Brian E. Lang
Rapid Communications in Mass Spectrometry | 2015
Norbert Stoppacher; Ralf D. Josephs; Adeline Daireaux; Tiphaine Choteau; Steven Westwood; Robert Wielgosz
Analytical and Bioanalytical Chemistry | 2013
Norbert Stoppacher; Ralf D. Josephs; Adeline Daireaux; Tiphaine Choteau; Steven Westwood; Robert Wielgosz