Adérito Soares da Mota
Federal University of Uberlandia
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Adérito Soares da Mota.
Brazilian Dental Journal | 2011
Gisele Rodrigues da Silva; Paulo César Freitas Santos-Filho; Paulo Cézar Simamoto-Júnior; Luis Roberto Marcondes Martins; Adérito Soares da Mota; Carlos José Soares
Restoring flared endodontically treated teeth continues to be a challenge for clinicians. This study evaluated the effect of post types and restorative techniques on the strain, fracture resistance, and fracture mode of incisors with weakened roots. One hundred five endodontically treated bovine incisors roots (15 mm) were divided into 7 groups (n=15). The two control groups were (C) intact roots restored with Cpc (cast posts and core) or Gfp (glass fiber posts). The five experimental groups were (F) flared roots restored with GfpAp (Gfp associated with accessory glass fiber posts), GfpRc (anatomic Gfp, relined with composite resin), and GfpRcAp (anatomized Gfp with resin and accessory glass fiber posts). All teeth were restored with metal crowns. Mechanical fatigue was performed with 3x10(5)/50 N. Specimens were loaded at 45º, and the strain values (μS) were obtained on root buccal and proximal surfaces. Following that, the fracture resistance (N) was measured. One-way ANOVA and Tukeys HSD tests (α=0.05) were applied, and failure mode was checked. No significant difference in strain values among the groups was found. Cpc presented lower fracture resistance and more catastrophic failures in flared roots. Gfp associated with composite resin or accessory glass fiber posts seems to be an effective method to improve the biomechanical behavior of flared roots.
Brazilian Dental Journal | 2004
Marlete Ribeiro da Silva; Joäo Carlos Gabrielli Biffi; Adérito Soares da Mota; Alfredo Júlio Fernandes Neto; Flávio Domingues das Neves
The aim of this study was to determine the effect of ultrasonic vibration on the force necessary to remove pre-fabricated and anatomic and cast posts. Two hundred and forty teeth were divided into two groups. In group I, a 0.8-mm metallic pre-fabricated post, Unimetric-Maillefer, was utilized; in group II, cast copper-aluminum alloy posts measuring 0.8, 1.0 and 1.2 mm in diameter were used. The root canals were prepared in three different diameters: 0.8, 1.0 and 1.2 mm, with a length of 10 mm. The posts were cemented with glass ionomer cement resulting in 20 specimens for each subgroup. Half of the sample was submitted to ultrasonic vibration for 3 min, while the other half did not receive any vibration. The specimens were submitted to traction in a universal testing machine. The results were analyzed by non-parametric Mann-Whitney U, Wilcoxon and Kruskal-Wallis tests. The application of ultrasonic vibration significantly reduced the retention provided by the glass ionomer cement in the fixation of intracanal posts. The ultrasonic action was effective in both pre-fabricated and anatomic and cast posts. The effectiveness of the ultrasonic vibration was not related to the cementation line or the diameter of the post.
Brazilian Dental Journal | 2010
Carlos José Soares; Liliane Minglini Barbosa; Fernanda Ribeiro Santana; Priscilla Barbosa Ferreira Soares; Adérito Soares da Mota; Gisele Rodrigues da Silva
This study evaluate the use of bovine teeth as a substitute for human teeth on fracture strength tests of composite fixed partial dentures (Cpd), with and without fiberglass reinforcement (Fg). Eighty teeth were selected, being 40 bovine incisors, 20 human premolars and 20 molars. Bovine incisors were ground to get a platform, simulating an occlusal surface of human molar. Teeth in pairs were embedded in polystyrene resin, simulating the periodontal ligament and divided in 4 groups: B-Cpd-Fg: bovine teeth restored with Cpd with Fg; B-Cpd-NFg: bovine teeth restored with Cpd without Fg; H-Cpd-Fg: human teeth restored Cpd with Fg; and H-Cpd-NFg: human teeth restored with Cpd without Fg. The Cpd were adhesively fixed and submitted to an axial compression load at the pontic center with a crosshead speed of 0.5 mm/min until fracture. Failure modes were assessed and classified. Data were subjected to two-way ANOVA and Tukeys HSD test (α=0.05). The tooth type had no influence on fracture strength and fracture mode. The inclusion of fiberglass increased significantly the fracture strength. The failure modes were more reparable in groups with fiber-reinforcement. Bovine teeth can be used as a substitute for human teeth in these types of fracture strength tests.
Microscopy Research and Technique | 2011
Lucas Zago Naves; Fernanda Ribeiro Santana; Carolina Guimarães Castro; Andréa Dolores Correia Miranda Valdivia; Adérito Soares da Mota; Carlos Estrela; Lourenço Correr-Sobrinho; Carlos José Soares
Morphology, etching patterns, surface modification, and characterization of 2 different fiber posts: Gfp, Glass fiber post; and Cfp, carbon fiber were investigated by SEM analysis, after different surface treatments. Thirty fiber posts, being 15 Gfp and 15 Cfp were divided into a 5 surface treatments (n = 3): C‐alcohol 70% (control); HF 4%‐immersion in 4% hydrofluoric acid for 1min; H3PO4 37%‐immersion in 37% phosphoric acid for 30s; H2O2 10%‐immersion in 10% hydrogen peroxide for 20 min; H2O2 24%‐immersion in 24% hydrogen peroxide for 10 min. Morphology, etching patterns, surface modification and surface characterization were acessed by SEM analysis. SEM evaluation revealed that the post surface morphology was modified following all treatment when compared with a control group, for both type of reinforced posts. HF seems to penetrate around the fibers of Gfp and promoted surface alterations. The Cfp surface seems to be inert to treatment with HF 4%. Dissolution of epoxy resin and exposure of the superficial fiber was observed in both post groups, regardless the type of reinforcing fiber, H2O2 in both concentrations. Relative smooth surface area was produced by H3PO4 37% treatment, but with similar features to untreated group. Surface treatment of fiber post is a determinant factor on micromechanical entanglement to resin composite core. Post treatment with hydrogen peroxide resulted strength of carbon and glass/epoxy resin fiber posts to resin composite core. Microsc. Res. Tech., 2011.
Journal of Applied Oral Science | 2009
Luís Henrique Araújo Raposo; Natália Antunes Neiva; Gisele Rodrigues da Silva; Hugo Lemes Carlo; Adérito Soares da Mota; Célio Jesus do Prado; Carlos José Soares
The esthetic and functional rehabilitation of patients with multiple missing teeth can be performed with several techniques and materials. Ceramic restorations provide reliable masticatory function and good esthetics. However, fracture can occur in some cases due to their brittle behavior. In some cases, the replacement of an extensive prosthesis is a problem due to the high treatment cost. In this paper, two cases are presented, in which fractures occurred in extensive metal-ceramic fixed partial dentures, and their replacement was not possible. Ceramic repair was chosen and the sequences of treatment with and without presence of the ceramic fragment are also discussed. The cases illustrate that, in some situations, fractured metal-ceramic partial dentures can be successfully repaired when prosthetic replacement is not a choice. Prosthodontists must use alternatives that allow a reliable repair to extensive metal-ceramic fixed partial dentures. Surface preparation of the ceramic with hydrofluoric acid in conjunction with a silane coupling agent is essential for a predictable bonding of composite resin. The repair performed with composite resin is an esthetic and functional alternative when extensive fixed partial dentures cannot be replaced.
International Journal of Dentistry | 2016
Lucas Costa de Medeiros Dantas; João Paulo da Silva-Neto; Talita Souza Dantas; Lucas Zago Naves; Flávio Domingues das Neves; Adérito Soares da Mota
This study sought to assess the effect of different surface finishing and polishing protocols on the surface roughness and bacterial adhesion (S. sanguinis) to polymethyl methacrylates (PMMA). Fifty specimens were divided into 5 groups (n = 10) according to their fabrication method and surface finishing protocol: LP (3 : 1 ratio and laboratory polishing), NF (Nealon technique and finishing), NP (Nealon technique and manual polishing), MF (3 : 1 ratio and manual finishing), and MP (3 : 1 ratio and manual polishing). For each group, five specimens were submitted to bacterial adhesion tests and analyzed by scanning electron microscopy (SEM). Two additional specimens were subjected to surface topography analysis by SEM and the remaining three specimens were subjected to surface roughness measurements. Data were compared by one-way ANOVA. The mean bacterial counts were as follows: NF, 19.6 ± 3.05; MP, 5.36 ± 2.08; NP, 4.96 ± 1.93; MF, 7.36 ± 2.45; and LP, 1.56 ± 0.62 (CFU). The mean surface roughness values were as follows: NF, 3.23 ± 0.15; MP, 0.52 ± 0.05; NP, 0.60 ± 0.08; MF, 2.69 ± 0.12; and LP, 0.07 ± 0.02 (μm). A reduction in the surface roughness was observed to be directly related to a decrease in bacterial adhesion. It was verified that the laboratory processing of PMMA might decrease the surface roughness and consequently the adhesion of S. sanguinis to this material.
Journal of Oral Implantology | 2014
Flávio Domingues das Neves; Gisele Araújo Elias; João Paulo da Silva-Neto; Lucas Costa de Medeiros Dantas; Adérito Soares da Mota; Alfredo Júlio Fernandes Neto
The aim of this study was to compare vertical and horizontal adjustments of castable abutments after conducting casting and soldering procedures. Twelve external hexagonal implants (3.75 × 10 mm) and their UCLA abutments were divided according their manufacturer and abutment type: PUN (plastic UCLA, Neodent), PUC (plastic UCLA, Conexão), PU3i (plastic UCLA, Biomet 3i), and PUTN (plastic UCLA with Tilite milled base, Neodent). Three infrastructures of a fixed partial implant-supported bridge with 3 elements were produced for each group. The measurements of vertical (VM) and horizontal (HM) misfits were obtained via scanning electron microscopy after completion of casting and soldering. The corresponding values were determined to be biomechanically acceptable to the system, and the results were rated as a percentage. Statistical analysis establishes differences between groups by chi-square after procedures, and McNemans test was applied to analyze the influence of soldering over casting (α ≤ .05). For the values of VM and HM, respectively, when the casting process was complete, it was observed that 83.25% and 100% (PUTN), 33.3% and 27.75% (PUN), 33.3% and 88.8% (PUC), 33.3% and 94.35% (PU3i) represented acceptable values. After completing the requisite soldering, acceptable values were 50% and 94.35% (PUTN), 16.6% and 77.7% (PUN), 38.55% and 77.7% (PUC), and 27.75% and 94.35% (PU3i). Within the limitations of this study, it can be concluded that the premachined abutments presented more acceptable VM values. The HM values were within acceptable limits before and after the soldering procedure for most groups. Further, the soldering procedure resulted in an increase of VM in all groups.
Brazilian Dental Journal | 2012
Gisele Rodrigues da Silva; Marina Guimarães Roscoe; Cristianne Pacheco Ribeiro; Adérito Soares da Mota; Luis Roberto Marcondes Martins; Carlos José Soares
Dental ceramics present excellent ability to reproduce the natural teeth regarding esthetic and biomechanics. Recently, due to the advancement of ceramic technology, metal-free restorations were developed. However, the traditional metal-ceramic restorations still present the requirements of high strength, long survival in the oral environment and favorable aesthetics. In this context, it is essential to know the specificity of each ceramic system available in order to apply it properly to various clinical situations. This report describes an integrated rehabilitation using metal-ceramic restorations of a patient at 50 years of age, who presented edentulous spaces, and previous unsatisfactory composite and amalgam restorations, and indirect metallic restorations, leading to compromised quality of life in both functional and psychosocial aspects. The impact on quality of life was measured using a generic instrument, OHIP-14, validated for the World Health Organization, which covers both the biological and the psychosocial dimensions. This instrument was applied to the patient before and after treatment. The patient had an overall OHIP-14 score of 28 before the treatment and after treatment the score decreased to 0, showing that dental and oral health conditions are factors that do impact on the quality of life. Rehabilitation has provided functional and aesthetic restorations, harmony of the stomatognathic system and improvement of life quality.
Brazilian Dental Journal | 2013
Gabriela Campos Mesquita; Crisnicaw Veríssimo; Luís Henrique Araújo Raposo; Paulo César Freitas Santos-Filho; Adérito Soares da Mota; Carlos José Soares
The cure time of endodontic sealers may influence the bond strength of fiber posts to root dentin. Forty teeth were selected and endodontically filled using calcium hydroxide cement and then divided into 2 groups according to the time elapsed between endodontic filling and post luting (n = 20): Immediately - glass fiber post luting immediately after endodontic filling; and Delayed - post luting performed 7 days after endodontic filling. The roots were also subdivided according to resin cement used for post luting (RelyX ARC and RelyX Unicem). The specimens were stored at 37°C for 24 h and sectioned in six 1-mm-thick slices from cervical, middle and apical thirds. The slice specimens were submitted to a push-out test at a crosshead speed of 0.5 mm/min, and the bond strength values obtained (MPa) were submitted to two-way ANOVA in a split-plot arrangement and Tukeys test (α=0.05). For both RelyX ARC and Unicem, the bond strength was significantly higher when the posts were cemented 7 days after the endodontic treatment. RelyX Unicem showed significantly higher bond strength values than RelyX ARC for both cementation periods. It was concluded that post luting should be made after the complete setting of the root canal sealer. Self-adhesive resin cement should be preferred for fiber post luting.
Brazilian Oral Research | 2012
Michele Andrea Lopes Iglesias; Gabriela Campos Mesquita; Analice Giovani Pereira; Lucas Costa de Medeiros Dantas; Luís Henrique Araújo Raposo; Carlos José Soares; Adérito Soares da Mota
The core finishing of cast posts-and-cores after luting is routine in dental practice. However, the effects of the vibrations produced by the rotary cutting instruments over the luting cements are not well-documented. This study evaluated the influence of the time intervals that elapsed between the cementation and the core-finishing procedures on the tensile strength of cast posts-and-cores luted with zinc phosphate cement. Forty-eight bovine incisor roots were selected, endodontically treated, and divided into four groups (n = 12): GA, control (without finishing); GB, GC, and GD, subjected to finishing at 20 minutes, 60 minutes, and 24 hours after cementation, respectively. Root canals were molded, and the resin patterns were cast in copper-aluminum alloy. Cast posts-and-cores were luted with zinc phosphate cement, and the core-finishing procedures were applied according to the groups. The tensile tests were performed at a crosshead speed of 0.5 mm/min for all groups, 24 hours after the core-finishing procedures. The data were subjected to one-way analysis of variance (ANOVA) and Tukeys test (α = 0.05). No significant differences were observed in the tensile strengths between the control and experimental groups, regardless of the time interval that elapsed between the luting and finishing steps. Within the limitations of the present study, it was demonstrated that the core-finishing procedures and time intervals that elapsed after luting did not appear to affect the retention of cast posts-and-cores when zinc phosphate cement was used.