Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Ahmad Haidar is active.

Publication


Featured researches published by Ahmad Haidar.


Automatica | 2008

Technical communique: Delay-range-dependent control synthesis for time-delay systems with actuator saturation

Lixian Zhang; El Kebir Boukas; Ahmad Haidar

The control synthesis problem for a class of linear time-delay systems with actuator saturation is investigated in this paper. The time delay is considered to be time-varying and has lower and upper bounds. A delay-range-dependent approach is adopted and the corresponding existence conditions of the stabilizing state-feedback controller are derived in terms of LMIs. An estimate for the domain of attraction of the origin can be obtained for the underlying systems with different time-delay ranges. Two numerical examples are presented to show the effectiveness and less conservatism of the developed theoretical results.


Diabetes Care | 2013

Closed-Loop Basal Insulin Delivery Over 36 Hours in Adolescents With Type 1 Diabetes: Randomized clinical trial

Daniela Elleri; Janet M. Allen; Kavita Kumareswaran; Lalantha Leelarathna; Marianna Nodale; Karen Caldwell; Peiyao Cheng; Craig Kollman; Ahmad Haidar; Helen R. Murphy; Malgorzata E. Wilinska; Carlo L. Acerini; David B. Dunger; Roman Hovorka

OBJECTIVE We evaluated the safety and efficacy of closed-loop basal insulin delivery during sleep and after regular meals and unannounced periods of exercise. RESEARCH DESIGN AND METHODS Twelve adolescents with type 1 diabetes (five males; mean age 15.0 [SD 1.4] years; HbA1c 7.9 [0.7]%; BMI 21.4 [2.6] kg/m2) were studied at a clinical research facility on two occasions and received, in random order, either closed-loop basal insulin delivery or conventional pump therapy for 36 h. During closed-loop insulin delivery, pump basal rates were adjusted every 15 min according to a model predictive control algorithm informed by subcutaneous sensor glucose levels. During control visits, subjects’ standard infusion rates were applied. Prandial insulin boluses were given before main meals (50–80 g carbohydrates) but not before snacks (15–30 g carbohydrates). Subjects undertook moderate-intensity exercise, not announced to the algorithm, on a stationary bicycle at a 140 bpm heart rate in the morning (40 min) and afternoon (20 min). Primary outcome was time when plasma glucose was in the target range (71–180 mg/dL). RESULTS Closed-loop basal insulin delivery increased percentage time when glucose was in the target range (median 84% [interquartile range 78–88%] vs. 49% [26–79%], P = 0.02) and reduced mean plasma glucose levels (128 [19] vs. 165 [55] mg/dL, P = 0.02). Plasma glucose levels were in the target range 100% of the time on 17 of 24 nights during closed-loop insulin delivery. Hypoglycemia occurred on 10 occasions during control visits and 9 occasions during closed-loop delivery (5 episodes were exercise related, and 4 occurred within 2.5 h of prandial bolus). CONCLUSIONS Day-and-night closed-loop basal insulin delivery can improve glucose control in adolescents. However, unannounced moderate-intensity exercise and excessive prandial boluses pose challenges to hypoglycemia-free closed-loop basal insulin delivery.


The Lancet Diabetes & Endocrinology | 2015

Comparison of dual-hormone artificial pancreas, single-hormone artificial pancreas, and conventional insulin pump therapy for glycaemic control in patients with type 1 diabetes: an open-label randomised controlled crossover trial

Ahmad Haidar; Laurent Legault; Virginie Messier; Tina Maria Mitre; Catherine Leroux; Rémi Rabasa-Lhoret

BACKGROUND The artificial pancreas is an emerging technology for the treatment of type 1 diabetes and two configurations have been proposed: single-hormone (insulin alone) and dual-hormone (insulin and glucagon). We aimed to delineate the usefulness of glucagon in the artificial pancreas system. METHODS We did a randomised crossover trial of dual-hormone artificial pancreas, single-hormone artificial pancreas, and conventional insulin pump therapy (continuous subcutaneous insulin infusion) in participants aged 12 years or older with type 1 diabetes. Participants were assigned in a 1:1:1:1:1:1 ratio with blocked randomisation to the three interventions and attended a research facility for three 24-h study visits. During visits when the patient used the single-hormone artificial pancreas, insulin was delivered based on glucose sensor readings and a predictive dosing algorithm. During dual-hormone artificial pancreas visits, glucagon was also delivered during low or falling glucose. During conventional insulin pump therapy visits, patients received continuous subcutaneous insulin infusion. The study was not masked. The primary outcome was the time for which plasma glucose concentrations were in the target range (4·0-10·0 mmol/L for 2 h postprandially and 4·0-8·0 mmol/L otherwise). Hypoglycaemic events were defined as plasma glucose concentration of less than 3·3 mmol/L with symptoms or less than 3·0 mmol/L irrespective of symptoms. Analysis was by modified intention to treat, in which we included data for all patients who completed at least two visits. A p value of less than 0·0167 (0·05/3) was regarded as significant. This trial is registered with ClinicalTrials.gov, number NCT01754337. FINDINGS The mean proportion of time spent in the plasma glucose target range over 24 h was 62% (SD 18), 63% (18), and 51% (19) with single-hormone artificial pancreas, dual-hormone artificial pancreas, and conventional insulin pump therapy, respectively. The mean difference in time spent in the target range between single-hormone artificial pancreas and conventional insulin pump therapy was 11% (17; p=0·002) and between dual-hormone artificial pancreas and conventional insulin pump therapy was 12% (21; p=0·00011). There was no difference (15; p=0·75) in the proportion of time spent in the target range between the single-hormone and dual-hormone artificial pancreas systems. There were 52 hypoglycaemic events with conventional insulin pump therapy (12 of which were symptomatic), 13 with the single-hormone artificial pancreas (five of which were symptomatic), and nine with the dual-hormone artificial pancreas (0 of which were symptomatic); the number of nocturnal hypoglycaemic events was 13 (0 symptomatic), 0, and 0, respectively. INTERPRETATION Single-hormone and dual-hormone artificial pancreas systems both provided better glycaemic control than did conventional insulin pump therapy. The single-hormone artificial pancreas might be sufficient for hypoglycaemia-free overnight glycaemic control. FUNDING Canadian Diabetes Association; Fondation J A De Sève; Juvenile Diabetes Research Foundation; and Medtronic.


Diabetes Care | 2011

Closed-Loop Insulin Delivery During Pregnancy Complicated by Type 1 Diabetes

Helen R. Murphy; Daniela Elleri; Janet M. Allen; Julie Harris; David Simmons; Gerry Rayman; Rosemary C. Temple; David B. Dunger; Ahmad Haidar; Marianna Nodale; Malgorzata E. Wilinska; Roman Hovorka

OBJECTIVE This study evaluated closed-loop insulin delivery with a model predictive control (MPC) algorithm during early (12–16 weeks) and late gestation (28–32 weeks) in pregnant women with type 1 diabetes. RESEARCH DESIGN AND METHODS Ten women with type 1 diabetes (age 31 years, diabetes duration 19 years, BMI 24.1 kg/m2, booking A1C 6.9%) were studied over 24 h during early (14.8 weeks) and late pregnancy (28.0 weeks). A nurse adjusted the basal insulin infusion rate from continuous glucose measurements (CGM), fed into the MPC algorithm every 15 min. Mean glucose and time spent in target (63–140 mg/dL), hyperglycemic (>140 to ≥180 mg/dL), and hypoglycemic (<63 to ≤50 mg/dL) were calculated using plasma and sensor glucose measurements. Linear mixed-effects models were used to compare glucose control during early and late gestation. RESULTS During closed-loop insulin delivery, median (interquartile range) plasma glucose levels were 117 (100.8–154.8) mg/dL in early and 126 (109.8–140.4) mg/dL in late gestation (P = 0.72). The overnight mean (interquartile range) plasma glucose time in target was 84% (50–100%) in early and 100% (94–100%) in late pregnancy (P = 0.09). Overnight mean (interquartile range) time spent hyperglycemic (>140 mg/dL) was 7% (0–40%) in early and 0% (0–6%) in late pregnancy (P = 0.25) and hypoglycemic (<63 mg/dL) was 0% (0–3%) and 0% (0–0%), respectively (P = 0.18). Postprandial glucose control, glucose variability, insulin infusion rates, and CGM sensor accuracy were no different in early or late pregnancy. CONCLUSIONS MPC algorithm performance was maintained throughout pregnancy, suggesting that overnight closed-loop insulin delivery could be used safely during pregnancy. More work is needed to achieve optimal postprandial glucose control.


Automatica | 2009

Brief paper: Exponential stability of singular systems with multiple time-varying delays

Ahmad Haidar; El Kebir Boukas

This paper deals with the class of continuous-time singular linear systems with multiple time-varying delays in a range. The global exponential stability problem of this class of systems is addressed. Delay-range-dependent sufficient conditions such that the system is regular, impulse-free and @a-stable are developed in the linear matrix inequality (LMI) setting. Moreover, an estimate of the convergence rate of such stable systems is presented. A numerical example is employed to show the usefulness of the proposed results.


Diabetes Care | 2016

Outcome measures for artificial pancreas clinical trials: A consensus report

David M. Maahs; Bruce Buckingham; Jessica R. Castle; Ali Cinar; Edward R. Damiano; Eyal Dassau; J. Hans De Vries; Francis J. Doyle; Steven C. Griffen; Ahmad Haidar; Lutz Heinemann; Roman Hovorka; Timothy W. Jones; Craig Kollman; Boris P. Kovatchev; Brian L. Levy; Revital Nimri; David O'Neal; Moshe Philip; Eric Renard; Steven J. Russell; Stuart A. Weinzimer; Howard Zisser; John Lum

Research on and commercial development of the artificial pancreas (AP) continue to progress rapidly, and the AP promises to become a part of clinical care. In this report, members of the JDRF Artificial Pancreas Project Consortium in collaboration with the wider AP community 1) advocate for the use of continuous glucose monitoring glucose metrics as outcome measures in AP trials, in addition to HbA1c, and 2) identify a short set of basic, easily interpreted outcome measures to be reported in AP studies whenever feasible. Consensus on a broader range of measures remains challenging; therefore, reporting of additional metrics is encouraged as appropriate for individual AP studies or study groups. Greater consistency in reporting of basic outcome measures may facilitate the interpretation of study results by investigators, regulatory bodies, health care providers, payers, and patients themselves, thereby accelerating the widespread adoption of AP technology to improve the lives of people with type 1 diabetes.


The Lancet Diabetes & Endocrinology | 2015

Outpatient overnight glucose control with dual-hormone artificial pancreas, single-hormone artificial pancreas, or conventional insulin pump therapy in children and adolescents with type 1 diabetes: an open-label, randomised controlled trial

Ahmad Haidar; Laurent Legault; Laurence Matteau-Pelletier; Virginie Messier; Maryse Dallaire; Martin Ladouceur; Rémi Rabasa-Lhoret

BACKGROUND Additional benefits of the dual-hormone (insulin and glucagon) artificial pancreas compared with the single-hormone (insulin alone) artificial pancreas have not been assessed in young people in outpatient unrestricted conditions. We evaluated the efficacy of three systems for nocturnal glucose control in children and adolescents with type 1 diabetes. METHODS We did a randomised, three-way, crossover trial in children aged 9-17 years with type 1 diabetes attending a diabetes camp in Canada. With use of sealed envelopes, children were randomly assigned in a 1:1:1:1:1:1 ratio with blocks of six to different sequences of the three interventions (single-hormone artificial pancreas, dual-hormone artificial pancreas, and conventional continuous subcutaneous insulin pump therapy). Each intervention was applied for 3 consecutive nights. Participants, study staff, and endpoint assessors were not masked. The primary outcome was the percentage of time spent with glucose concentrations lower than 4·0 mmol/L from 2300 h to 0700 h. Analysis was by intention to treat. A p value of less than 0·0167 was regarded as significant. This study is registered with ClinicalTrials.gov, number NCT02189694. FINDINGS Between June 30, 2014, and Aug 9, 2014, we enrolled 33 children of mean age 13·3 years (SD 2·3; range 9-17). The time spent at a glucose concentration lower than 4·0 mmol/L was median 0% (IQR 0·0-2·4) during nights with the dual-hormone artificial pancreas, 3·1% (0·0-6·9) during nights with the single-hormone artificial pancreas (p=0·032), and 3·4% (0-11·0) during nights with conventional pump therapy (p=0·0048 compared with dual-hormone artificial pancreas and p=0·32 compared with single-hormone artificial pancreas). 15 hypoglycaemic events (<3·1 mmol/L for 20 min measured by sensor then confirmed with capillary glucose <4·0 mmol/L) were noted during nights with conventional pump therapy compared with four events with the single-hormone system and no events with the dual-hormone system. None of the assessed outcomes varied with the order in which children and young adults were assigned interventions. INTERPRETATION The dual-hormone artificial pancreas could improve nocturnal glucose control in children and adolescents with type 1 diabetes. Longer and larger outpatient studies are now needed. FUNDING Canadian Diabetes Association, Fondation J A De Sève.


Diabetes Technology & Therapeutics | 2013

Assessing Performance of Closed-Loop Insulin Delivery Systems by Continuous Glucose Monitoring: Drawbacks and Way Forward

Roman Hovorka; Marianna Nodale; Ahmad Haidar; Malgorzata E. Wilinska

BACKGROUND We investigated whether continuous glucose monitoring (CGM) levels can accurately assess glycemic control while directing closed-loop insulin delivery. SUBJECTS AND METHODS Data were analyzed retrospectively from 33 subjects with type 1 diabetes who underwent closed-loop and conventional pump therapy on two separate nights. Glycemic control was evaluated by reference plasma glucose and contrasted against three methods based on Navigator (Abbott Diabetes Care, Alameda, CA) CGM levels. RESULTS Glucose mean and variability were estimated by unmodified CGM levels with acceptable clinical accuracy. Time when glucose was in target range was overestimated by CGM during closed-loop nights (CGM vs. plasma glucose median [interquartile range], 86% [65-97%] vs. 75% [59-91%]; P=0.04) but not during conventional pump therapy (57% [32-72%] vs. 51% [29-68%]; P=0.82) providing comparable treatment effect (mean [SD], 28% [29%] vs. 23% [21%]; P=0.11). Using the CGM measurement error of 15% derived from plasma glucose-CGM pairs (n=4,254), stochastic interpretation of CGM gave unbiased estimate of time in target during both closed-loop (79% [62-86%] vs. 75% [59-91%]; P=0.24) and conventional pump therapy (54% [33-66%] vs. 51% [29-68%]; P=0.44). Treatment effect (23% [24%] vs. 23% [21%]; P=0.96) and time below target were accurately estimated by stochastic CGM. Recalibrating CGM using reference plasma glucose values taken at the start and end of overnight closed-loop was not superior to stochastic CGM. CONCLUSIONS CGM is acceptable to estimate glucose mean and variability, but without adjustment it may overestimate benefit of closed-loop. Stochastic CGM provided unbiased estimate of time when glucose is in target and below target and may be acceptable for assessment of closed-loop in the outpatient setting.


Diabetes Technology & Therapeutics | 2013

Evaluating the accuracy and large inaccuracy of two continuous glucose monitoring systems.

Lalantha Leelarathna; Marianna Nodale; Janet M. Allen; Daniela Elleri; Kavita Kumareswaran; Ahmad Haidar; Karen Caldwell; Malgorzata E. Wilinska; Carlo L. Acerini; Mark L. Evans; Helen R. Murphy; David B. Dunger; Roman Hovorka

OBJECTIVE This study evaluated the accuracy and large inaccuracy of the Freestyle Navigator (FSN) (Abbott Diabetes Care, Alameda, CA) and Dexcom SEVEN PLUS (DSP) (Dexcom, Inc., San Diego, CA) continuous glucose monitoring (CGM) systems during closed-loop studies. RESEARCH DESIGN AND METHODS Paired CGM and plasma glucose values (7,182 data pairs) were collected, every 15-60 min, from 32 adults (36.2±9.3 years) and 20 adolescents (15.3±1.5 years) with type 1 diabetes who participated in closed-loop studies. Levels 1, 2, and 3 of large sensor error with increasing severity were defined according to absolute relative deviation greater than or equal to ±40%, ±50%, and ±60% at a reference glucose level of ≥6 mmol/L or absolute deviation greater than or equal to ±2.4 mmol/L,±3.0 mmol/L, and ±3.6 mmol/L at a reference glucose level of <6 mmol/L. RESULTS Median absolute relative deviation was 9.9% for FSN and 12.6% for DSP. Proportions of data points in Zones A and B of Clarke error grid analysis were similar (96.4% for FSN vs. 97.8% for DSP). Large sensor over-reading, which increases risk of insulin over-delivery and hypoglycemia, occurred two- to threefold more frequently with DSP than FSN (once every 2.5, 4.6, and 10.7 days of FSN use vs. 1.2, 2.0, and 3.7 days of DSP use for Level 1-3 errors, respectively). At levels 2 and 3, large sensor errors lasting 1 h or longer were absent with FSN but persisted with DSP. CONCLUSIONS FSN and DSP differ substantially in the frequency and duration of large inaccuracy despite only modest differences in conventional measures of numerical and clinical accuracy. Further evaluations are required to confirm that FSN is more suitable for integration into closed-loop delivery systems.


The Journal of Clinical Endocrinology and Metabolism | 2016

Single- and Dual-Hormone Artificial Pancreas for Overnight Glucose Control in Type 1 Diabetes

Ahmad Haidar; Rémi Rabasa-Lhoret; Laurent Legault; Leif E. Lovblom; Rohan Rakheja; Virginie Messier; Émilie D'Aoust; C. Marcelo Falappa; Tara Justice; Andrej Orszag; Holly Tschirhart; Maryse Dallaire; Martin Ladouceur; Bruce A. Perkins

CONTEXT The added benefit of glucagon in artificial pancreas systems for overnight glucose control in type 1 diabetes has not been fully explored. OBJECTIVE The objective of the study was to compare the efficacy of dual-hormone (insulin and glucagon) artificial pancreas, single-hormone (insulin alone) artificial pancreas, and conventional insulin pump therapy. DESIGN This study was a three-center, three-arm, open-label, randomized, crossover controlled trial involving three interventions, each applied over a night after a high carbohydrate/high fat meal and a second after exercise to mimic real-life glycemic excursions. SETTING The study was conducted in a home setting. PATIENTS Twenty-eight type 1 diabetes participants (21 adults and seven adolescents) participated in the study. INTERVENTIONS Dual-hormone artificial pancreas, single-hormone artificial pancreas, and conventional pump therapy was activated from 9:00 PM to 7:00 AM. MAIN OUTCOME The main outcome was a proportion of time in target (4-8 mmol/L) by continuous glucose monitoring from 11:00 PM to 7:00 AM. Analysis was by intention to treat. RESULTS The median (interquartile range) percentage of time-in-target glucose range was 47% (36%-71%) for conventional therapy, higher on both single-hormone (76% [65%-91%], P < .001) and dual-hormone artificial pancreas (81 [68%-93%], P < .001). The median (interquartile range) time spent below 4 mmol/L was 14% (4%-28%) for conventional therapy, lower on both single-hormone (5% [0%-13%], P = .004) and dual-hormone artificial pancreas (1% [0%-8%], P < .001). There were 14 hypoglycemic events on conventional therapy compared with six incidences on the single-hormone artificial pancreas (P = .059) and three incidences on the dual-hormone artificial pancreas (P = .017). None of these outcomes differed significantly between single- and dual-hormone configurations. CONCLUSIONS Single- and dual-hormone artificial pancreas systems both provided better glucose control than conventional therapy. Although the dual-hormone configuration did not increase overnight time-in-target glucose levels, an effect on lowering hypoglycemia risk cannot be ruled out.

Collaboration


Dive into the Ahmad Haidar's collaboration.

Top Co-Authors

Avatar

Laurent Legault

McGill University Health Centre

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge