Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Ahmad Khairi Abdul Wahab is active.

Publication


Featured researches published by Ahmad Khairi Abdul Wahab.


Clinical Biomechanics | 2014

Mechanomyography and muscle function assessment: A review of current state and prospects

Morufu Olusola Ibitoye; Nur Azah Hamzaid; Jorge M. Zuniga; Ahmad Khairi Abdul Wahab

Previous studies have explored to saturation the efficacy of the conventional signal (such as electromyogram) for muscle function assessment and found its clinical impact limited. Increasing demand for reliable muscle function assessment modalities continues to prompt further investigation into other complementary alternatives. Application of mechanomyographic signal to quantify muscle performance has been proposed due to its inherent mechanical nature and ability to assess muscle function non-invasively while preserving muscular neurophysiologic information. Mechanomyogram is gaining accelerated applications in evaluating the properties of muscle under voluntary and evoked muscle contraction with prospects in clinical practices. As a complementary modality and the mechanical counterpart to electromyogram; mechanomyogram has gained significant acceptance in analysis of isometric and dynamic muscle actions. Substantial studies have also documented the effectiveness of mechanomyographic signal to assess muscle performance but none involved comprehensive appraisal of the state of the art applications with highlights on the future prospect and potential integration into the clinical practices. Motivated by the dearth of such critical review, we assessed the literature to investigate its principle of acquisition, current applications, challenges and future directions. Based on our findings, the importance of rigorous scientific and clinical validation of the signal is highlighted. It is also evident that as a robust complement to electromyogram, mechanomyographic signal may possess unprecedented potentials and further investigation will be enlightening.


PLOS ONE | 2016

Strategies for Rapid Muscle Fatigue Reduction during FES Exercise in Individuals with Spinal Cord Injury: A Systematic Review

Morufu Olusola Ibitoye; Nur Azah Hamzaid; Nazirah Hasnan; Ahmad Khairi Abdul Wahab; Glen M. Davis

Background Rapid muscle fatigue during functional electrical stimulation (FES)-evoked muscle contractions in individuals with spinal cord injury (SCI) is a significant limitation to attaining health benefits of FES-exercise. Delaying the onset of muscle fatigue is often cited as an important goal linked to FES clinical efficacy. Although the basic concept of fatigue-resistance has a long history, recent advances in biomedical engineering, physiotherapy and clinical exercise science have achieved improved clinical benefits, especially for reducing muscle fatigue during FES-exercise. This review evaluated the methodological quality of strategies underlying muscle fatigue-resistance that have been used to optimize FES therapeutic approaches. The review also sought to synthesize the effectiveness of these strategies for persons with SCI in order to establish their functional impacts and clinical relevance. Methods Published scientific literature pertaining to the reduction of FES-induced muscle fatigue was identified through searches of the following databases: Science Direct, Medline, IEEE Xplore, SpringerLink, PubMed and Nature, from the earliest returned record until June 2015. Titles and abstracts were screened to obtain 35 studies that met the inclusion criteria for this systematic review. Results Following the evaluation of methodological quality (mean (SD), 50 (6) %) of the reviewed studies using the Downs and Black scale, the largest treatment effects reported to reduce muscle fatigue mainly investigated isometric contractions of limited functional and clinical relevance (n = 28). Some investigations (n = 13) lacked randomisation, while others were characterised by small sample sizes with low statistical power. Nevertheless, the clinical significance of emerging trends to improve fatigue-resistance during FES included (i) optimizing electrode positioning, (ii) fine-tuning of stimulation patterns and other FES parameters, (iii) adjustments to the mode and frequency of exercise training, and (iv) biofeedback-assisted FES-exercise to promote selective recruitment of fatigue-resistant motor units. Conclusion Although the need for further in-depth clinical trials (especially RCTs) was clearly warranted to establish external validity of outcomes, current evidence was sufficient to support the validity of certain techniques for rapid fatigue-reduction in order to promote FES therapy as an integral part of SCI rehabilitation. It is anticipated that this information will be valuable to clinicians and other allied health professionals administering FES as a treatment option in rehabilitation and aid the development of effective rehabilitation interventions.


Sensors | 2014

Mechanomyographic parameter extraction methods: An appraisal for clinical applications

Morufu Olusola Ibitoye; Nur Azah Hamzaid; Jorge M. Zuniga; Nazirah Hasnan; Ahmad Khairi Abdul Wahab

The research conducted in the last three decades has collectively demonstrated that the skeletal muscle performance can be alternatively assessed by mechanomyographic signal (MMG) parameters. Indices of muscle performance, not limited to force, power, work, endurance and the related physiological processes underlying muscle activities during contraction have been evaluated in the light of the signal features. As a non-stationary signal that reflects several distinctive patterns of muscle actions, the illustrations obtained from the literature support the reliability of MMG in the analysis of muscles under voluntary and stimulus evoked contractions. An appraisal of the standard practice including the measurement theories of the methods used to extract parameters of the signal is vital to the application of the signal during experimental and clinical practices, especially in areas where electromyograms are contraindicated or have limited application. As we highlight the underpinning technical guidelines and domains where each method is well-suited, the limitations of the methods are also presented to position the state of the art in MMG parameters extraction, thus providing the theoretical framework for improvement on the current practices to widen the opportunity for new insights and discoveries. Since the signal modality has not been widely deployed due partly to the limited information extractable from the signals when compared with other classical techniques used to assess muscle performance, this survey is particularly relevant to the projected future of MMG applications in the realm of musculoskeletal assessments and in the real time detection of muscle activity.


Sensors | 2014

The Effectiveness of FES-Evoked EMG Potentials to Assess Muscle Force and Fatigue in Individuals with Spinal Cord Injury

Morufu Olusola Ibitoye; Eduardo H. Estigoni; Nur Azah Hamzaid; Ahmad Khairi Abdul Wahab; Glen M. Davis

The evoked electromyographic signal (eEMG) potential is the standard index used to monitor both electrical changes within the motor unit during muscular activity and the electrical patterns during evoked contraction. However, technical and physiological limitations often preclude the acquisition and analysis of the signal especially during functional electrical stimulation (FES)-evoked contractions. Hence, an accurate quantification of the relationship between the eEMG potential and FES-evoked muscle response remains elusive and continues to attract the attention of researchers due to its potential application in the fields of biomechanics, muscle physiology, and rehabilitation science. We conducted a systematic review to examine the effectiveness of eEMG potentials to assess muscle force and fatigue, particularly as a biofeedback descriptor of FES-evoked contractions in individuals with spinal cord injury. At the outset, 2867 citations were identified and, finally, fifty-nine trials met the inclusion criteria. Four hypotheses were proposed and evaluated to inform this review. The results showed that eEMG is effective at quantifying muscle force and fatigue during isometric contraction, but may not be effective during dynamic contractions including cycling and stepping. Positive correlation of up to r = 0.90 (p < 0.05) between the decline in the peak-to-peak amplitude of the eEMG and the decline in the force output during fatiguing isometric contractions has been reported. In the available prediction models, the performance index of the eEMG signal to estimate the generated muscle force ranged from 3.8% to 34% for 18 s to 70 s ahead of the actual muscle force generation. The strength and inherent limitations of the eEMG signal to assess muscle force and fatigue were evident from our findings with implications in clinical management of spinal cord injury (SCI) population.


Sensors | 2016

Estimation of Electrically-Evoked Knee Torque from Mechanomyography Using Support Vector Regression

Morufu Olusola Ibitoye; Nur Azah Hamzaid; Ahmad Khairi Abdul Wahab; Nazirah Hasnan; Sunday Olusanya Olatunji; Glen M. Davis

The difficulty of real-time muscle force or joint torque estimation during neuromuscular electrical stimulation (NMES) in physical therapy and exercise science has motivated recent research interest in torque estimation from other muscle characteristics. This study investigated the accuracy of a computational intelligence technique for estimating NMES-evoked knee extension torque based on the Mechanomyographic signals (MMG) of contracting muscles that were recorded from eight healthy males. Simulation of the knee torque was modelled via Support Vector Regression (SVR) due to its good generalization ability in related fields. Inputs to the proposed model were MMG amplitude characteristics, the level of electrical stimulation or contraction intensity, and knee angle. Gaussian kernel function, as well as its optimal parameters were identified with the best performance measure and were applied as the SVR kernel function to build an effective knee torque estimation model. To train and test the model, the data were partitioned into training (70%) and testing (30%) subsets, respectively. The SVR estimation accuracy, based on the coefficient of determination (R2) between the actual and the estimated torque values was up to 94% and 89% during the training and testing cases, with root mean square errors (RMSE) of 9.48 and 12.95, respectively. The knee torque estimations obtained using SVR modelling agreed well with the experimental data from an isokinetic dynamometer. These findings support the realization of a closed-loop NMES system for functional tasks using MMG as the feedback signal source and an SVR algorithm for joint torque estimation.


Journal of Artificial Organs | 2017

Extracorporeal carbon dioxide removal (ECCO2R) in respiratory deficiency and current investigations on its improvement: a review

Hany Hazfiza Manap; Ahmad Khairi Abdul Wahab

The implementation of extracorporeal carbon dioxide removal (ECCO2R) as one of the extracorporeal life support system is getting more attention today. Thus, the objectives of this paper are to study the clinical practice of commercial ECCO2R system, current trend of its development and also the perspective on future improvement that can be done to the existing ECCO2R system. The strength of this article lies in its review scope, which focuses on the commercial ECCO2R therapy in the market based on membrane lung and current investigation to improve the efficiency of the ECCO2R system, in terms of surface modification by carbonic anhydrase (CA) immobilization technique and respiratory electrodialysis (R-ED). Our methodology approach involves the identification of relevant published literature from PubMed and Web of Sciences search engine using the terms Extracorporeal Carbon Dioxide Removal (ECCO2R), Extracorporeal life support, by combining terms between ECCO2R and CA and also ECCO2R with R-ED. This identification only limits articles in English language. Overall, several commercial ECCO2R systems are known and proven safe to be used in patients in terms of efficiency, safety and risk of complication. In addition, CA-modified hollow fiber for membrane lung and R-ED are proven to have good potential to be applied in conventional ECCO2R design. The detailed technique and current progress on CA immobilization and R-ED development were also reviewed in this article.


Medical Engineering & Physics | 2016

Torque and mechanomyogram relationships during electrically-evoked isometric quadriceps contractions in persons with spinal cord injury

Morufu Olusola Ibitoye; Nur Azah Hamzaid; Nazirah Hasnan; Ahmad Khairi Abdul Wahab; Md. Anamul Islam; Victor S.P. Kean; Glen M. Davis

The interaction between muscle contractions and joint loading produces torques necessary for movements during activities of daily living. However, during neuromuscular electrical stimulation (NMES)-evoked contractions in persons with spinal cord injury (SCI), a simple and reliable proxy of torque at the muscle level has been minimally investigated. Thus, the purpose of this study was to investigate the relationships between muscle mechanomyographic (MMG) characteristics and NMES-evoked isometric quadriceps torques in persons with motor complete SCI. Six SCI participants with lesion levels below C4 [(mean (SD) age, 39.2 (7.9) year; stature, 1.71 (0.05) m; and body mass, 69.3 (12.9) kg)] performed randomly ordered NMES-evoked isometric leg muscle contractions at 30°, 60° and 90° knee flexion angles on an isokinetic dynamometer. MMG signals were detected by an accelerometer-based vibromyographic sensor placed over the belly of rectus femoris muscle. The relationship between MMG root mean square (MMG-RMS) and NMES-evoked torque revealed a very high association (R(2)=0.91 at 30°; R(2)=0.98 at 60°; and R(2)=0.97 at 90° knee angles; P<0.001). MMG peak-to-peak (MMG-PTP) and stimulation intensity were less well related (R(2)=0.63 at 30°; R(2)=0.67 at 60°; and R(2)=0.45 at 90° knee angles), although were still significantly associated (P≤0.006). Test-retest interclass correlation coefficients (ICC) for the dependent variables ranged from 0.82 to 0.97 for NMES-evoked torque, between 0.65 and 0.79 for MMG-RMS, and from 0.67 to 0.73 for MMG-PTP. Their standard error of measurements (SEM) ranged between 10.1% and 31.6% (of mean values) for torque, MMG-RMS and MMG-PTP. The MMG peak frequency (MMG-PF) of 30Hz approximated the stimulation frequency, indicating NMES-evoked motor unit firing rate. The results demonstrated knee angle differences in the MMG-RMS versus NMES-isometric torque relationship, but a similar torque related pattern for MMG-PF. These findings suggested that MMG was well associated with torque production, reliably tracking the motor unit recruitment pattern during NMES-evoked muscle contractions. The strong positive relationship between MMG signal and NMES-evoked torque production suggested that the MMG might be deployed as a direct proxy for muscle torque or fatigue measurement during leg exercise and functional movements in the SCI population.


ieee region 10 conference | 2000

Temperature control for chemical reactor using adaptive neural network control strategy

Ahmad Khairi Abdul Wahab; Mohd Azlan Hussain; Mohd Zaki Sulaiman

A pilot scaled chemical reactor is constructed and commissioned to study various conventional and advanced control strategies. One of the approaches is the use of neural network inverse model based controller to control the temperature of the chemical reactor. Neural network control was chosen due to its capabilities to overcome the hassle in periodically tuning the conventional controller to obtain a good process response for a certain set point. Tests in a form of load disturbance and set point tracking are carried out to evaluate the neural network controller. The neural network controller exhibits satisfactory performance. Simulation work prior to the planned online implementation is vital to predict the control strategy performance and behavior. With the expected performance in hand, one has the prior knowledge of the control strategy.


Sensors | 2017

Mechanomyography and Torque during FES-Evoked Muscle Contractions to Fatigue in Individuals with Spinal Cord Injury

Nor Zainah Mohamad; Nur Azah Hamzaid; Glen M. Davis; Ahmad Khairi Abdul Wahab; Nazirah Hasnan

A mechanomyography muscle contraction (MC) sensor, affixed to the skin surface, was used to quantify muscle tension during repetitive functional electrical stimulation (FES)-evoked isometric rectus femoris contractions to fatigue in individuals with spinal cord injury (SCI). Nine persons with motor complete SCI were seated on a commercial muscle dynamometer that quantified peak torque and average torque outputs, while measurements from the MC sensor were simultaneously recorded. MC-sensor-predicted measures of dynamometer torques, including the signal peak (SP) and signal average (SA), were highly associated with isometric knee extension peak torque (SP: r = 0.91, p < 0.0001), and average torque (SA: r = 0.89, p < 0.0001), respectively. Bland-Altman (BA) analyses with Lin’s concordance (ρC) revealed good association between MC-sensor-predicted peak muscle torques (SP; ρC = 0.91) and average muscle torques (SA; ρC = 0.89) with the equivalent dynamometer measures, over a range of FES current amplitudes. The relationship of dynamometer torques and predicted MC torques during repetitive FES-evoked muscle contraction to fatigue were moderately associated (SP: r = 0.80, p < 0.0001; SA: r = 0.77; p < 0.0001), with BA associations between the two devices fair-moderate (SP; ρC = 0.70: SA; ρC = 0.30). These findings demonstrated that a skin-surface muscle mechanomyography sensor was an accurate proxy for electrically-evoked muscle contraction torques when directly measured during isometric dynamometry in individuals with SCI. The novel application of the MC sensor during FES-evoked muscle contractions suggested its possible application for real-world tasks (e.g., prolonged sit-to-stand, stepping,) where muscle forces during fatiguing activities cannot be directly measured.


IOP Conference Series: Materials Science and Engineering | 2017

Mathematical Modelling of Carbon Dioxide Exchange in Hollow Fiber Membrane Oxygenator

Hany Hazfiza Manap; Ahmad Khairi Abdul Wahab; Fathiah Mohamed Zuki

The main objective of this study is to simulate the carbon dioxide (CO2) blood-gas exchange in membrane oxygenator, evaluate the effect of sweep gas flow rate on CO2 partial pressure (pCO2) and to determine the response of pCO2 to the step change of sweep gas flow rate. In extension to the simulation of gas transfer in membrane oxygenator, open-loop response on sweep gas flow rate was applied to the developed mathematical model to prove its effect on CO2 removal rate. Three sweep gas flow rates were set, i.e. 1 L/min (Qg/Qb = 0.5), 2 L/min (Qg/Qb = 1) and 4 L/min (Qg/Qb = 2) and the simulated pCO2 in artery was observed. Next, one-way ANOVA test was performed to determine the significant difference in CO2 removal rate between these gas flow rates. For the next test, sweep gas flow rate was changed at t = 60 second and t = 120 second of simulation, to evaluate how pCO2 will response to the step change of gas flow rate. As the result, the highest CO2 removal observed when Qg/Qb = 2, as compared to gas-blood ratio of 1 and 0.5. The ANOVA test also proved the significant difference in simulated pCO2 for each flow rate. For the last test, a proportional response of pCO2 towards the change of sweep gas flow rate was highlighted. In conclusion, the rate of CO2 removal from blood can be manipulated by sweep gas flow rate and this rate can be adjusted to achieve the optimum performance of membrane oxygenator for CO2 sequestration.

Collaboration


Dive into the Ahmad Khairi Abdul Wahab's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Rosli Omar

Universiti Teknikal Malaysia Melaka

View shared research outputs
Top Co-Authors

Avatar

Md. Anamul Islam

Universiti Malaysia Perlis

View shared research outputs
Researchain Logo
Decentralizing Knowledge