Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Aileen Grassmann is active.

Publication


Featured researches published by Aileen Grassmann.


Clinical Journal of The American Society of Nephrology | 2015

Body Composition and Survival in Dialysis Patients: Results from an International Cohort Study

Daniele Marcelli; Len Usvyat; Peter Kotanko; Inga Bayh; Bernard Canaud; Michael Etter; Emanuele Gatti; Aileen Grassmann; Yuedong Wang; Cristina Marelli; Laura Scatizzi; Andrea Stopper; Frank M. van der Sande; Jeroen P. Kooman

BACKGROUND AND OBJECTIVES High body mass index appears protective in hemodialysis patients, but uncertainty prevails regarding which components of body composition, fat or lean body mass, are primarily associated with survival. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS Data between April 2006 and December 2012 were extracted from the Fresenius Medical Care Europe subset of the international MONitoring Dialysis Outcomes initiative. Fresenius Medical Care Europe archives a unique repository of predialysis body composition measurements determined by multifrequency bioimpedance (BCM Body Composition Monitor). The BCM Body Composition Monitor reports lean tissue indices (LTIs) and fat tissue indices (FTIs), which are the respective tissue masses normalized to height squared, relative to an age- and sex-matched healthy population. The relationship between LTI and FTI and all-cause mortality was studied by Kaplan-Meier analysis, multivariate Cox regression, and smoothing spline ANOVA logistic regression. RESULTS In 37,345 hemodialysis patients, median (25th-75th percentile) LTI and FTI were 12.2 (10.3-14.5) and 9.8 (6.6-12.4) kg/m(2), respectively. Median (25th-75th percentile) follow-up time was 266 (132-379) days; 3458 (9.2%) patients died during follow-up. Mortality was lowest with both LTI and FTI in the 10th-90th percentile (reference group) and significantly higher at the lower LTI and FTI extreme (hazard ratio [HR], 3.37; 95% confidence interval [95% CI], 2.94 to 3.87; P<0.001). Survival was best with LTI between 15 and 20 kg/m(2) and FTI between 4 and 15 kg/m(2) (probability of death during follow-up: <5%). When taking the relation between both compartments into account, the interaction was significant (P=0.01). Higher FTI appeared protective in patients with low LTI (HR, 3.37; 95% CI, 2.94 to 3.87; P<0.001 at low LTI-low FTI, decreasing to HR, 1.79; 95% CI, 1.47 to 2.17; P<0.001 at low LTI-high FTI). CONCLUSIONS This large international study indicates best survival in patients with both LTI and FTI in the 10th-90th percentiles of a healthy population. In analyses of body composition, both lean tissue and fat tissue compartments and also their relationship should be considered.


Kidney International | 2014

Cannulation technique influences arteriovenous fistula and graft survival.

Maria Teresa Parisotto; Volker Schoder; Cristina Miriunis; Aileen Grassmann; Laura Scatizzi; Peter Kaufmann; Andrea Stopper; Daniele Marcelli

Hemodialysis patient survival is dependent on the availability of a reliable vascular access. In clinical practice, procedures for vascular access cannulation vary from clinic to clinic. We investigated the impact of cannulation technique on arteriovenous fistula and graft survival. Based on an April 2009 cross-sectional survey of vascular access cannulation practices in 171 dialysis units, a cohort of patients with corresponding vascular access survival information was selected for follow-up ending March 2012. Of the 10,807 patients enrolled in the original survey, access survival data were available for 7058 patients from nine countries. Of these, 90.6% had an arteriovenous fistula and 9.4% arteriovenous graft. Access needling was by area technique for 65.8%, rope-ladder for 28.2%, and buttonhole for 6%. The most common direction of puncture was antegrade with bevel up (43.1%). A Cox regression model was applied, adjusted for within-country effects, and defining as events the need for creation of a new vascular access. Area cannulation was associated with a significantly higher risk of access failure than rope-ladder or buttonhole. Retrograde direction of the arterial needle with bevel down was also associated with an increased failure risk. Patient application of pressure during cannulation appeared more favorable for vascular access longevity than not applying pressure or using a tourniquet. The higher risk of failure associated with venous pressures under 100 or over 150 mm Hg should open a discussion on limits currently considered acceptable.


Kidney International | 2013

Interdialytic weight gain, systolic blood pressure, serum albumin, and C-reactive protein levels change in chronic dialysis patients prior to death

Len Usvyat; Claudia Barth; Inga Bayh; Michael Etter; Gero von Gersdorff; Aileen Grassmann; Adrian Guinsburg; Maggie Lam; Daniele Marcelli; Cristina Marelli; Laura Scatizzi; Mathias Schaller; Adam Tashman; Ted Toffelmire; Stephan Thijssen; Jeroen P. Kooman; Frank M. van der Sande; Nathan W. Levin; Yuedong Wang; Peter Kotanko

Reports from a United States cohort of chronic hemodialysis patients suggested that weight loss, a decline in pre-dialysis systolic blood pressure, and decreased serum albumin may precede death. However, no comparative studies have been reported in such patients from other countries. Here we analyzed dynamic changes in these parameters in hemodialysis patients and included 3593 individuals from 5 Asian countries; 35,146 from 18 European countries; 8649 from Argentina; and 4742 from the United States. In surviving prevalent patients, these variables appeared to have notably different dynamics than in patients who died. While in all populations the interdialytic weight gain, systolic blood pressure, and serum albumin levels were stable in surviving patients, these indicators declined starting more than a year ahead in those who died with the dynamics similar irrespective of gender and geographic region. In European patients, C-reactive protein levels were available on a routine basis and indicated that levels of this acute-phase protein were low and stable in surviving patients but rose sharply before death. Thus, relevant fundamental biological processes start many months before death in the majority of chronic hemodialysis patients. Longitudinal monitoring of these dynamics may help to identify patients at risk and aid the development of an alert system to initiate timely interventions to improve outcomes.


Artificial Organs | 2015

High-Volume Postdilution Hemodiafiltration Is a Feasible Option in Routine Clinical Practice

Daniele Marcelli; Caecilia Scholz; Pedro Ponce; Tânia Sousa; Pascal Kopperschmidt; Aileen Grassmann; Bruno Pinto; Bernard Canaud

Hemodiafiltration (HDF) with 20–22 L of substitution fluid is increasingly recognized as associated with significant benefits regarding patient outcome. However, some doubt exists as to whether these high volumes can be achieved in routine clinical practice. A total of 4176 sessions with 366 patients on postdilution HDF were analyzed in this 1-month observational cohort study with prospective data collection. All dialysis machines were equipped with AutoSub plus signal analysis software that automatically and continuously adapts the substitution fluid flow according to the blood flow, blood viscosity, and dialyzer characteristics. Percentages of sessions with different types of vascular access were compared regarding achievement of ≥21 L substitution fluid. Logistic regression analysis was conducted to study the independent relationship of selected variables with achievement of ≥21 L substitution volume. Patient- and dialysis-related variables that showed an association with the convection volume were entered in a multivariable model that included hematocrit up front. Respectively, 87%, 84%, and 33% of routine sessions conducted with fistulas, grafts, and catheters qualified as high-volume HDF. Serum albumin levels ≥4.2 g/dL were positively associated with the achievement of at least 21 L substitution volume. Positive associations were also observed for blood flows in the ranges 350–399 and ≥400 mL/min compared with the reference range (300–350 mL/min), for longer treatment time, for fistula versus catheter, for higher filtration fraction, and for dialysis conducted at the end of the week versus Monday. It can be concluded that implementation and sustainability of high-volume HDF is possible in routine clinical practice for almost all patients treated with fistulas and grafts.


Journal of Renal Nutrition | 2016

Longitudinal Changes in Body Composition in Patients After Initiation of Hemodialysis Therapy: Results From an International Cohort

Daniele Marcelli; Katharina Brand; Pedro Ponce; Andrzej Milkowski; Cristina Marelli; Ercan Ok; José-Ignacio Merello Godino; Konstantin Gurevich; Tomas Jirka; Jaroslav Rosenberger; Attilio Di Benedetto; Erzsébet Ladányi; Aileen Grassmann; Laura Scatizzi; Inga Bayh; Jeroen P. Kooman; Bernard Canaud

OBJECTIVE In patients with advanced kidney disease, metabolic and nutritional derangements induced by uremia interact and reinforce each other in a deleterious vicious circle. Literature addressing the effect of dialysis initiation on changes in body composition (BC) is limited and contradictory. The aim of this study was to evaluate changes in BC in a large international cohort of incident hemodialysis patients. METHODS A total of 8,227 incident adult end-stage renal disease patients with BC evaluation within the initial first 6 months of baseline, defined as 6 months after renal replacement therapy initiation, were considered. BC, including fat tissue index (FTI) and lean tissue index (LTI), were evaluated by Body Composition Monitor (BCM, Fresenius Medical Care, Bad Homburg, Germany). Exclusion criteria at baseline were lack of a BCM measurement before or after baseline, body mass index (BMI) < 18.5 kg/m(2), presence of metastatic solid tumors, treatment with a catheter, and prescription of less or more than 3 treatments per week. Maximum follow-up was 2 years. Descriptive analysis was performed comparing current values with the baseline in each interval (delta analysis). Linear mixed models considering the correlation structure of the repeated measurements were used to evaluate factors associated with different trends in FTI and LTI. RESULTS BMI increased about 0.6 kg/m(2) over 24 months from baseline. This was associated with increase in FTI of about 0.95 kg/m(2) and a decrease in LTI of about 0.4 kg/m(2). Female gender, diabetic status, and low baseline FTI were associated with a significant greater increase of FTI. Age > 67 years, diabetes, male gender, high baseline LTI, and low baseline FTI were associated with a significant greater decrease of LTI. CONCLUSIONS With the transition to hemodialysis, end-stage renal disease patients presented with distinctive changes in BC. These were mainly associated with gender, older age, presence of diabetes, low baseline FTI, and high baseline LTI. BMI increases did not fully represent the changes in BC.


Kidney International | 2017

Impact of fluid status and inflammation and their interaction on survival: a study in an international hemodialysis patient cohort

Marijke Dekker; Daniele Marcelli; Bernard Canaud; Paola Carioni; Yuedong Wang; Aileen Grassmann; Constantijn Konings; Peter Kotanko; Karel M.L. Leunissen; Nathan W. Levin; Frank M. van der Sande; Xiaoling Ye; Vaibhav Maheshwari; Len Usvyat; Jeroen P. Kooman

In hemodialysis patients extracellular fluid overload is a predictor of all-cause and cardiovascular mortality, and a relation with inflammation has been reported in previous studies. The magnitude and nature of this interaction and the effects of moderate fluid overload and extracellular fluid depletion on survival are still unclear. We present the results of an international cohort study in 8883 hemodialysis patients from the European MONDO initiative database where, during a three-month baseline period, fluid status was assessed using bioimpedance and inflammation by C-reactive protein. All-cause mortality was recorded during 12 months of follow up. In a second analysis a three-month baseline period was added to the first baseline period, and changes in fluid and inflammation status were related to all-cause mortality during six-month follow up. Both pre-dialysis estimated fluid overload and fluid depletion were associated with an increased mortality, already apparent at moderate levels of estimated pre-dialysis fluid overload (1.1-2.5L); hazard ratio 1.64 (95% confidence interval 1.35-1.98). In contrast, post-dialysis estimated fluid depletion was associated with a survival benefit (0.74 [0.62-0.90]). The concurrent presence of fluid overload and inflammation was associated with the highest risk of death. Thus, while pre-dialysis fluid overload was associated with inflammation, even in the absence of inflammation, fluid overload remained a significant risk factor for short-term mortality, even following improvement of fluid status.


Blood Purification | 2012

Converting to a Capitation System for Dialysis Payment - The Portuguese Experience

Pedro Ponce; Daniele Marcelli; António Guerreiro; Aileen Grassmann; Carlos Gonçalves; Laura Scatizzi; Inga Bayh; Andrea Stopper; Ricardo Da Silva

Due to the challenge of operating within an economically strained healthcare budget, Portuguese health authorities convened with dialysis providers and agreed on a framework to change from a fee-for-service reimbursement modality to a capitation payment system for hemodialysis. This article reviews the components of the agreed capitation package implemented in 2008 as well as the necessary preparatory work undertaken by a for-profit 34-unit dialysis network (approx. 4,200 patients) to cope with the introduction of this system. Furthermore, trends in clinical quality indicators and in resource management are reviewed for 3 years immediately following capitation introduction. Here, improvements were observed over time for the specified clinical targets. Simultaneously, costs controllable by the physician could be reduced. As more countries convert to a capitation or bundled payment system for hemodialysis services, this article offers insight into the scope of the necessary preparatory work and the possible consequences in terms of costs and treatment quality.


Blood Purification | 2013

Monitoring dialysis outcomes across the world--the MONDO Global Database Consortium

G.D. von Gersdorff; Len Usvyat; Danielle Marcelli; Aileen Grassmann; Cristina Marelli; Michael Etter; J.P. Kooman; Albert Power; Ted Toffelmire; Yosef S. Haviv; Adrian Guinsburg; Claudia Barth; Mathias Schaller; Inga Bayh; Laura Scatizzi; Adam Tashman; Stephan Thijssen; Nathan W. Levin; F.M. van der Sande; C. Pusey; Yuedong Wang; Peter Kotanko

Background/Aims: Dialysis providers frequently collect detailed longitudinal and standardized patient data, providing valuable registries of routine care. However, even large organizations are restricted to certain regions, limiting their ability to separate effects of local practice from the pathophysiology shared by most dialysis patients. To overcome this limitation, the MONDO (MONitoring Dialysis Outcomes) research consortium has created a platform for the joint analysis of data from almost 200,000 dialysis patients worldwide. Methods: We examined design and operation of MONDO as well as its methodology with respect to patient inclusion, descriptive data and other study parameters. Results: MONDO partners contribute primary databases of anonymized patient data and collaboratively analyze populations across national and regional boundaries. To that end, datasets from different electronic health record systems are converted into a uniform structure. Patients are enrolled without systematic exclusions into open cohorts representing the diversity of patients. A large number of patient level treatment and outcome data is recorded frequently and can be analyzed with little delay. Detailed variable definitions are used to determine if a parameter can be studied in a subset or all databases. Conclusion: MONDO has created a large repository of validated dialysis data, expanding the opportunities for outcome studies in dialysis patients. The density of longitudinal information facilitates in particular trend analysis. Limitations include the paucity of uniform definitions and standards regarding descriptive information (e.g. comorbidities), which limits the identification of patient subsets. Through its global outreach, depth, breadth and size, MONDO advances the observational study of dialysis patients and care.


Nephrology Dialysis Transplantation | 2013

Impact of targeting Kt instead of Kt/V

Francisco Maduell; Rosa Ramos; Inés Palomares; Alejandro Martin-Malo; Manolo Molina; Jesus Bustamante; Rafael Pérez-García; Aileen Grassmann; José Ignacio Merello

BACKGROUND Patients must receive an adequate dialysis dose in each hemodialysis (HD) session. Ionic dialysance (ID) enables the dialysis dose to be monitored in each session. The aim of this study was to compare the achievement of Kt versus eKt/V values and to analyse the main impediments to reaching the dialysis dose. METHODS Of 5316 patients from 54 Fresenius Medical Care centers in Spain undergoing their usual HD regime, 3275 received ID and were included in the study. RESULTS The minimum prescribed dose of eKt/V was reached in 91.2% of the patients, while the minimum recommended dose of Kt was reached in only 66.8%. Patients not receiving the minimum Kt dose were older, had spent 7 months less on dialysis, had a dialysis duration of 6 min less, had 5.7 kg more of body weight and Qb was 47 mL/min lower. The target Kt was not reached by 62% of patients with catheters and by 37% of women. With each quintile increase of body weight, eKt/V decreased and Kt increased. Of patients with a body weight >80 kg, 1.4%, mostly men, reached the target Kt but not prescribed eKt/V. CONCLUSIONS The impact of monitoring the dose with Kt instead of Kt/V is that identifies 25.8% of patients who did not reach the minimum Kt while achieving Kt/V. The main impediments to achieving an adequate dialysis dose were catheter use, female sex, advanced age, greater body weight, shorter dialysis time and lower Qb.


PLOS ONE | 2015

The forgotten role of central volume in low frequency oscillations of heart rate variability.

Manuela Ferrario; Ulrich Moissl; Francesco Garzotto; Dinna N. Cruz; Ciro Tetta; Maria Gabriella Signorini; Claudio Ronco; Aileen Grassmann; Sergio Cerutti; Stefano Guzzetti

The hypothesis that central volume plays a key role in the source of low frequency (LF) oscillations of heart rate variability (HRV) was tested in a population of end stage renal disease patients undergoing conventional hemodialysis (HD) treatment, and thus subject to large fluid shifts and sympathetic activation. Fluid overload (FO) in 58 chronic HD patients was assessed by whole body bioimpedance measurements before the midweek HD session. Heart Rate Variability (HRV) was measured using 24-hour Holter electrocardiogram recordings starting before the same HD treatment. Time domain and frequency domain analyses were performed on HRV signals. Patients were retrospectively classified in three groups according to tertiles of FO normalized to the extracellular water (FO/ECW%). These groups were also compared after stratification by diabetes mellitus. Patients with the low to medium hydration status before the treatment (i.e. 1st and 2nd FO/ECW% tertiles) showed a significant increase in LF power during last 30 min of HD compared to dialysis begin, while no significant change in LF power was seen in the third group (i.e. those with high pre-treatment hydration values). In conclusion, several mechanisms can generate LF oscillations in the cardiovascular system, including baroreflex feedback loops and central oscillators. However, the current results emphasize the role played by the central volume in determining the power of LF oscillations.

Collaboration


Dive into the Aileen Grassmann's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Peter Kotanko

Icahn School of Medicine at Mount Sinai

View shared research outputs
Top Co-Authors

Avatar

Inga Bayh

Fresenius Medical Care

View shared research outputs
Top Co-Authors

Avatar

Len Usvyat

Fresenius Medical Care

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Pedro Ponce

Fresenius Medical Care

View shared research outputs
Top Co-Authors

Avatar

Yuedong Wang

University of California

View shared research outputs
Researchain Logo
Decentralizing Knowledge