Akihiro Nogi
Nara Medical University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Akihiro Nogi.
Journal of Vascular Surgery | 2013
Shigeo Ichihashi; Nagaaki Marugami; Toshihiro Tanaka; Shinichi Iwakoshi; Norio Kurumatani; Satoru Kitano; Akihiro Nogi; Kimihiko Kichikawa
OBJECTIVE Contrast-enhanced computed tomography (CE-CT) has been commonly used for follow-up imaging after endovascular aneurysm repair (EVAR), but it is difficult to use on patients with renal insufficiency. Superparamagnetic iron oxide (SPIO) particles, contrast medium for magnetic resonance imaging (MRI) that has been widely used for detection of the liver tumor, rarely affects renal function. The present study examined SPIO-enhanced dynamic MRI as a potential alternative to CE-CT for detection of endoleaks after EVAR. METHODS Institutional review board approval was obtained for this prospective study. Twenty-three consecutive patients with normal renal function were evaluated using both CE-CT and SPIO-enhanced MRI within 2 weeks after EVAR. The median interval between the two modalities was 2 days. SPIO-enhanced MRI was performed at 1.5 T with T1-weighted, SPIO-enhanced dynamic, and postcontrast T1-weighted gradient echo sequences. The CE-CT protocol consisted of triple scans. Two experienced, blinded observers evaluated all images. Consensus reading of CE-CT and SPIO-MRI was defined as the reference standard. Interobserver, intraobserver, and intermodality agreement for endoleak detection was assessed by κ statistics. RESULTS A total of 11 type II endoleaks originating from either the lumbar or inferior mesenteric artery were detected. Eight were able to be detected by CE-CT (8/11:73%) and 10 (10/11:91%) by SPIO-enhanced MRI. Interobserver (κ = 0.91; 95% CI, 0.74-1.00) and intraobserver agreement for MRI (κ = 1.00) were excellent. Intermodality agreement for endoleak detection was moderate (κ = 0.63; 95% CI, 0.32-0.94; and κ = 0.62; 95% CI, 0.29-0.95 for observers A and B, respectively). CONCLUSIONS SPIO-enhanced MRI could represent a useful alternative to CE-CT, as it offers excellent interobserver, intraobserver agreement, and could detect more endoleaks than CE-CT.
Nihon Hōshasen Gijutsu Gakkai zasshi | 2015
Kozo Shimizu; Yuya Yamatani; Akihiro Nogi; Toshinari Okamoto
The most common methods to determine the signal-to-noise ratio (SNR) of magnetic resonance imaging (MRI) are based on the signal statistics in regions of interest (ROIs) in a magnitude image. For this, methods to calculate the ROI have still several discussions; we assumed SNR of a magnitude image could be estimated from standard deviation of a phase image (the phase method). The purpose of this study is to evaluate the validity of the phase method to determine the SNR. The simulation using digital phantom was carried out for evaluation of the effect to measure SNR; fluctuation in the phase image and SNR of the magnitude image. The phantom study was also performed for evaluation of the validity of estimation using the phase method in comparison with the conventional method (the identical ROI method and the subtraction method). The result of the simulation showed that SNR of magnitude image is larger than 4 for the SNR measurement using the phase method and this results reliable. The influence of fluctuation of the phase image should be eliminated for practical purposes. In the phantom study, phase method showed similar results compared to conventional methods in condition with elimination of the fluctuation of the phase image. Though there was a difference in the results of the phase method and the subtraction method according to the position of the ROI, the error was less than 4%. In this study, the method using the phase image to determine the SNR was identified as valuable.
Japanese Journal of Radiological Technology | 2018
Akihiro Nogi
Nihon Hōshasen Gijutsu Gakkai zasshi | 2010
Yuya Yamatani; Tsukasa Doi; Kozo Shimizu; Akihiro Nogi
Japanese Journal of Radiological Technology | 2001
Akihiro Nogi; Tsukasa Doi; Asuka Kasai; Yoshimasa Mizuno
Japanese Journal of Radiological Technology | 2001
Tsukasa Doi; Akihiro Nogi; Yoshimasa Mizuno
Japanese Journal of Radiological Technology | 1998
Yoshimasa Mizuno; Akihiro Nogi; Tsukasa Doi; Katsuya Kokubo; Nobuhiro Morita
Japanese Journal of Radiological Technology | 1998
Akihiro Nogi; Tsukasa Doi; Yoshimasa Mizuno; Katsuya Kokubo; Nobuhiro Morita
Japanese Journal of Radiological Technology | 1997
Akihiro Nogi; Tadashi Yoshimine; Takeshi Tsujimoto; Takekazu Hosokawa; Toshitake Sawai; Tsukasa Doi
Japanese Journal of Radiological Technology | 1993
Akihiro Nogi; Mitsuhiro Nakamae; Tdashi Yoshimine; Satoshi Fukugami; Hidekazu Kitaba; Akiko Shirai; Kname Maeda