Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Akimasa Tsujimoto is active.

Publication


Featured researches published by Akimasa Tsujimoto.


Operative Dentistry | 2017

Influence of Thermal Cycling on Flexural Properties and Simulated Wear of Computer-aided Design/Computer-aided Manufacturing Resin Composites

Akimasa Tsujimoto; Wayne W. Barkmeier; Toshiki Takamizawa; Mark A. Latta; Masashi Miyazaki

OBJECTIVEnThe purpose of this study was to evaluate the influence of thermal cycling on the flexural properties and simulated wear of computer-aided design/computer-aided manufacturing (CAD/CAM) resin composites.nnnMETHODSnThe six CAD/CAM resin composites used in this study were 1) Lava Ultimate CAD/CAM Restorative (LU); 2) Paradigm MZ100 (PM); 3) CERASMART (CS); 4) Shofu Block HC (SB); 5) KATANA AVENCIA Block (KA); and 6) VITA ENAMIC (VE). Specimens were divided randomly into two groups, one of which was stored in distilled water for 24 hours, and the other of which was subjected to 10,000 thermal cycles. For each material, 15 specimens from each group were used to determine the flexural strength and modulus according to ISO 6872, and 20 specimens from each group were used to examine wear using a localized wear simulation model. The test materials were subjected to a wear challenge of 400,000 cycles in a Leinfelder-Suzuki device (Alabama machine). The materials were placed in custom-cylinder stainless steel fixtures, and simulated localized wear was generated using a stainless steel ball bearing (r=2.387 mm) antagonist in a water slurry of polymethyl methacrylate beads. Simulated wear was determined using a noncontact profilometer (Proscan 2100) with Proscan and AnSur 3D software.nnnRESULTSnThe two-way analysis of variance of flexural properties and simulated wear of CAD/CAM resin composites revealed that material type and thermal cycling had a significant influence (p<0.05), but there was no significant interaction (p>0.05) between the two factors. The flexural properties and maximum depth of wear facets of CAD/CAM resin composite were different (p<0.05) depending on the material, and their values were influenced (p>0.05) by thermal cycling, except in the case of VE. The volume losses in wear facets on LU, PM, and SB after 10,000 thermal cycles were significantly higher (p<0.05) than those after 24 hours of water storage, unlike CS, KA, and VE.nnnCONCLUSIONnThe results of this study indicate that the flexural properties and simulated wear of CAD/CAM resin composites are different depending on the material. In addition, the flexural properties and simulated wear of CAD/CAM resin composites are influenced by thermal cycling.


European Journal of Oral Sciences | 2016

Relationship between mechanical properties and bond durability of short fiber-reinforced resin composite with universal adhesive

Akimasa Tsujimoto; Wayne W. Barkmeier; Toshiki Takamizawa; Hidehiko Watanabe; William W. Johnson; Mark A. Latta; Masashi Miyazaki

The purpose of this study was to determine the relationship between mechanical properties and bond durability of short fiber-reinforced resin composite with universal adhesive. As controls, micro-hybrid and nano-hybrid resin composites were tested. The universal adhesives used were Scotchbond Universal, Adhese Universal, and G-Premio Bond. The fracture toughness and flexural properties of resin composites, and shear bond strength and shear fatigue strength of universal adhesive with resin composite using both total-etch and self-etch modes were determined. In the results, short fiber-reinforced resin composite showed significantly higher fracture toughness than did micro-hybrid and nano-hybrid resin composites. The flexural strength and modulus of short fiber-reinforced and nano-hybrid resin composites were significantly lower than were those of micro-hybrid resin composites. Regardless of etching mode, the shear bond strength of universal adhesives with short fiber-reinforced resin composite did not show any significant differences from micro-hybrid and nano-hybrid resin composites. The shear fatigue strength of universal adhesives with short fiber-reinforced resin composite and micro-hybrid resin composites were significantly higher than that of nano-hybrid resin composites. The results of this study suggest that the mechanical properties of short fiber-reinforced resin composite improve their bond durability with universal adhesive.


Dental Materials Journal | 2016

Mechanical properties, volumetric shrinkage and depth of cure of short fiber-reinforced resin composite

Akimasa Tsujimoto; Wayne W. Barkmeier; Toshiki Takamizawa; Mark A. Latta; Masashi Miyazaki

The mechanical properties, volumetric shrinkage and depth of cure of a short fiber-reinforced resin composite (SFRC) were investigated in this study and compared to both a bulk fill resin composite (BFRC) and conventional glass/ceramic-filled resin composite (CGRC). Fracture toughness, flexural properties, volumetric shrinkage and depth of cure of the SFRC, BFRC and CGRC were measured. SFRC had significantly higher fracture toughness than BFRCs and CGRCs. The flexural properties of SFRC were comparable with BFRCs and CGRCs. SFRC showed significantly lower volumetric shrinkage than the other tested resin composites. The depth of cure of the SFRC was similar to BFRCs and higher than CGRCs. The data from this laboratory investigation suggests that SFRC exhibits improvements in fracture toughness, volumetric shrinkage and depth of cure when compared with CGRC, but depth of cure of SFRC was similar to BFRC.


Operative Dentistry | 2017

Interfacial Characteristics and Bond Durability of Universal Adhesive to Various Substrates

Akimasa Tsujimoto; Wayne W. Barkmeier; Toshiki Takamizawa; Terry M. Wilwerding; Mark A. Latta; Masashi Miyazaki

OBJECTIVEnThis study investigated the interfacial characteristics and bond durability of universal adhesives to various substrates.nnnMETHODS AND MATERIALSnTwo universal adhesives were used: 1) Scotchbond Universal and 2) G-Premio Bond. The substrates used were bovine enamel and dentin with or without phosphoric acid etching, resin composite, lithium disilicate and leucite-reinforced glass ceramics, zirconia, and metal alloys. The surface free energy and the parameters of various substrates and of substrates treated by adhesive after light irradiation were determined by measuring the contact angles of three test liquids. Resin composite was bonded to the various substrates to determine shear bond strength after 24 hours water storage and 10,000 thermal cycles. A one-way analysis of variance (ANOVA) and the Tukey post hoc test were used for the surface free energy data, and a two-way ANOVA and the Tukey post hoc test were used for analysis of shear bond strength data (α=0.05).nnnRESULTSnThe interfacial characteristics of the various substrates show significant differences depending on the type of substrate, but the interfacial characteristics of substrate treated by adhesive after light irradiation did not show any significant differences regardless of the substrate used. The bond durability of two universal adhesives to various substrates differs depending on the type of substrate and the adhesive.nnnCONCLUSIONSnThe results of this study suggest that universal adhesives modify the interfacial characteristics of a wide range of substrates and create a consistent surface, but the bond durability of universal adhesive to various substrates differs depending on the type of substrate and the adhesive.


Operative Dentistry | 2016

The Effect of Phosphoric Acid Pre-etching Times on Bonding Performance and Surface Free Energy with Single-step Self-etch Adhesives

Akimasa Tsujimoto; Wayne W. Barkmeier; Toshiki Takamizawa; Mark A. Latta; Masashi Miyazaki

OBJECTIVEnThe purpose of this study was to evaluate the effect of phosphoric acid pre-etching times on shear bond strength (SBS) and surface free energy (SFE) with single-step self-etch adhesives.nnnMETHODSnThe three single-step self-etch adhesives used were: 1) Scotchbond Universal Adhesive (3M ESPE), 2) Clearfil tri-S Bond (Kuraray Noritake Dental), and 3) G-Bond Plus (GC). Two no pre-etching groups, 1) untreated enamel and 2) enamel surfaces after ultrasonic cleaning with distilled water for 30 seconds to remove the smear layer, were prepared. There were four pre-etching groups: 1) enamel surfaces were pre-etched with phosphoric acid (Etchant, 3M ESPE) for 3 seconds, 2) enamel surfaces were pre-etched for 5 seconds, 3) enamel surfaces were pre-etched for 10 seconds, and 4) enamel surfaces were pre-etched for 15 seconds. Resin composite was bonded to the treated enamel surface to determine SBS. The SFEs of treated enamel surfaces were determined by measuring the contact angles of three test liquids. Scanning electron microscopy was used to examine the enamel surfaces and enamel-adhesive interface.nnnRESULTSnThe specimens with phosphoric acid pre-etching showed significantly higher SBS and SFEs than the specimens without phosphoric acid pre-etching regardless of the adhesive system used. SBS and SFEs did not increase for phosphoric acid pre-etching times over 3 seconds. There were no significant differences in SBS and SFEs between the specimens with and without a smear layer.nnnCONCLUSIONnThe data suggest that phosphoric acid pre-etching of ground enamel improves the bonding performance of single-step self-etch adhesives, but these bonding properties do not increase for phosphoric acid pre-etching times over 3 seconds.


European Journal of Oral Sciences | 2016

Bonding performance and interfacial characteristics of short fiber-reinforced resin composite in comparison with other composite restoratives.

Akimasa Tsujimoto; Wayne W. Barkmeier; Toshiki Takamizawa; Mark A. Latta; Masashi Miyazaki

The purpose of this study was to investigate the shear bond strength (SBS) and surface free-energy (SFE) of short fiber-reinforced resin composite (SFRC), using different adhesive systems, in comparison with other composite restoratives. The resin composites used were everX Posterior (EP), Clearfil AP-X (CA), and Filtek Supreme Ultra Universal Restorative (FS). The adhesive systems used were Scotchbond Multi-Purpose (SM), Clearfil SE Bond (CS), and G-Premio Bond (GB). Resin composite was bonded to dentin, and SBS was determined after 24 h of storage in distilled water and after 10,000 thermal cycles (TCs). The SFEs of the resin composites and the adhesives were determined by measuring the contact angles of three test liquids. The SFE values and SFE characteristics were not influenced by the type of resin composite, but were influenced by the type of adhesive system. The results of this study suggest that the bonding performance and interfacial characteristics of SFRC are the same as for other composite restoratives, but that these parameters are affected by the type of adhesive system. The bonding performance of SFRC was enhanced by thermal cycling in a manner similar to that for other composite restoratives.


European Journal of Oral Sciences | 2016

Influence of duration of phosphoric acid pre-etching on bond durability of universal adhesives and surface free-energy characteristics of enamel

Akimasa Tsujimoto; Wayne W. Barkmeier; Toshiki Takamizawa; Hidehiko Watanabe; William W. Johnson; Mark A. Latta; Masashi Miyazaki

The purpose of this study was to evaluate the influence of duration of phosphoric acid pre-etching on the bond durability of universal adhesives and the surface free-energy characteristics of enamel. Three universal adhesives and extracted human molars were used. Two no-pre-etching groups were prepared: ground enamel; and enamel after ultrasonic cleaning with distilled water for 30 s to remove the smear layer. Four pre-etching groups were prepared: enamel pre-etched with phosphoric acid for 3, 5, 10, and 15 s. Shear bond strength (SBS) values of universal adhesive after no thermal cycling and after 30,000 or 60,000 thermal cycles, and surface free-energy values of enamel surfaces, calculated from contact angle measurements, were determined. The specimens that had been pre-etched showed significantly higher SBS and surface free-energy values than the specimens that had not been pre-etched, regardless of the aging condition and adhesive type. The SBS and surface free-energy values did not increase for pre-etching times of longer than 3 s. There were no significant differences in SBS values and surface free-energy characteristics between the specimens with and without a smear layer. The results of this study suggest that phosphoric acid pre-etching of enamel improves the bond durability of universal adhesives and the surface free-energy characteristics of enamel, but these bonding properties do not increase for phosphoric acid pre-etching times of longer than 3 s.


Dental Materials Journal | 2015

Influence of surface treatment of contaminated lithium disilicate and leucite glass ceramics on surface free energy and bond strength of universal adhesives.

Fumi Yoshida; Akimasa Tsujimoto; Ryo Ishii; Kie Nojiri; Toshiki Takamizawa; Masashi Miyazaki; Mark A. Latta

This study investigates the influence of surface treatment of contaminated lithium disilicate and leucite glass ceramic restorations on the bonding efficacy of universal adhesives. Lithium disilicate and leucite glass ceramics were contaminated with saliva, and then cleaned using distilled water (SC), or 37% phosphoric acid (TE), or hydrofluoric acid (CE). Specimens without contamination served as controls. The surface free energy was determined by measuring the contact angles formed when the three test liquids were placed on the specimens. Bond strengths of the universal adhesives were also measured. Saliva contamination and surface treatment of ceramic surfaces significantly influenced the surface free energy. The bond strengths of universal adhesives were also affected by surface treatment and the choice of adhesive materials. Our data suggest that saliva contamination of lithum disilicate and leucite glass ceramics significantly impaired the bonding of the universal adhesives, and reduced the surface free energy of the ceramics.


European Journal of Oral Sciences | 2017

Comparison between universal adhesives and two-step self-etch adhesives in terms of dentin bond fatigue durability in self-etch mode

Akimasa Tsujimoto; Wayne W. Barkmeier; Toshiki Takamizawa; Hidehiko Watanabe; William W. Johnson; Mark A. Latta; Masashi Miyazaki

This aim of this study was to compare universal adhesives and two-step self-etch adhesives in terms of dentin bond fatigue durability in self-etch mode. Three universal adhesives - Clearfil Universal, G-Premio Bond, and Scotchbond Universal Adhesive - and three-two-step self-etch adhesives - Clearfil SE Bond, Clearfil SE Bond 2, and OptiBond XTR - were used. The initial shear bond strength and shear fatigue strength of resin composite bonded to adhesive on dentin in self-etch mode were determined. Scanning electron microscopy observations of fracture surfaces after bond strength tests were also made. The initial shear bond strength of universal adhesives was material dependent, unlike that of two-step self-etch adhesives. The shear fatigue strength of Scotchbond Universal Adhesive was not significantly different from that of two-step self-etch adhesives, unlike the other universal adhesives. The shear fatigue strength of universal adhesives differed depending on the type of adhesive, unlike those of two-step self-etch adhesives. The results of this study encourage the continued use of two-step self-etch adhesive over some universal adhesives but suggest that changes to the composition of universal adhesives may lead to a dentin bond fatigue durability similar to that of two-step self-etch adhesives.


Dental Materials Journal | 2017

Depth of Cure, Flexural Properties and Volumetric Shrinkage of Low and High Viscosity Bulk-Fill Giomers and Resin Composites

Akimasa Tsujimoto; Wayne W. Barkmeier; Toshiki Takamizawa; Mark A. Latta; Masashi Miyazaki

The purpose of this study was to investigate the depth of cure, flexural properties and volumetric shrinkage of low and high viscosity bulk-fill giomers and resin composites. Depth of cure and flexural properties were determined according to ISO 4049, and volumetric shrinkage was measured using a dilatometer. The depths of cure of giomers were significantly lower than those of resin composites, regardless of photo polymerization times. No difference in flexural strength and modulus was found among either high or low viscosity bulk fill materials. Volumetric shrinkage of low and high viscosity bulk-fill resin composites was significantly less than low and high viscosity giomers. Depth of cure of both low and high viscosity bulk-fill materials is time dependent. Flexural strength and modulus of high viscosity or low viscosity bulk-fill giomer or resin composite materials are not different for their respective category. Resin composites exhibited less polymerization shrinkage than giomers.

Collaboration


Dive into the Akimasa Tsujimoto's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

William W. Johnson

University of Nebraska Medical Center College of Dentistry

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge