Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Alex Nemiroski is active.

Publication


Featured researches published by Alex Nemiroski.


Science | 2012

Camouflage and Display for Soft Machines

Stephen A. Morin; Robert F. Shepherd; Sen Wai Kwok; Adam A. Stokes; Alex Nemiroski; George M. Whitesides

Mechanical Chameleon A wide range of animals can adapt their color patterns as a means of camouflage or otherwise changing their appearance. This is accomplished through changes in coloration, contrast, patterning, or shape. Morin et al. (p. 828) show at a basic level that some of these features can be added as microfluidic layers attached to mobile, flexible, soft machines. By pumping different fluids through the channels, the robots were able to change their coloration or overall contrast and could thus blend into the background of the surface they were lying upon. Conversely, by pumping through fluids of different temperature, the infrared profile of the robot could be changed without changing its visible coloration. Soft robots with microfluidic channels in a skin layer show camouflaging abilities. Synthetic systems cannot easily mimic the color-changing abilities of animals such as cephalopods. Soft machines—machines fabricated from soft polymers and flexible reinforcing sheets—are rapidly increasing in functionality. This manuscript describes simple microfluidic networks that can change the color, contrast, pattern, apparent shape, luminescence, and surface temperature of soft machines for camouflage and display. The color of these microfluidic networks can be changed simultaneously in the visible and infrared—a capability that organisms do not have. These strategies begin to imitate the functions, although not the anatomies, of color-changing animals.


Proceedings of the National Academy of Sciences of the United States of America | 2014

Universal mobile electrochemical detector designed for use in resource-limited applications

Alex Nemiroski; Dionysios Christodouleas; Jonathan W. Hennek; Ashok Kumar; Elizabeth Jane Maxwell; María Teresa Fernández-Abedul; George M. Whitesides

Significance The ability to perform electrochemical testing in the field, and in resource-limited environments, and to transmit data automatically to “the cloud” can enable a broad spectrum of analyses useful for personal and public health, clinical analysis, food safety, and environmental monitoring. Although the developed world has many options for analysis and web connection, the developing world does not have broad access to either the expensive equipment necessary to perform these tests or the advanced technologies required for network connectivity. To overcome these limitations, we have developed a simple, affordable, handheld device that can perform all the most common electrochemical analyses, and transmit the results of testing to the cloud from any phone, over any network, anywhere in the world. This paper describes an inexpensive, handheld device that couples the most common forms of electrochemical analysis directly to “the cloud” using any mobile phone, for use in resource-limited settings. The device is designed to operate with a wide range of electrode formats, performs on-board mixing of samples by vibration, and transmits data over voice using audio—an approach that guarantees broad compatibility with any available mobile phone (from low-end phones to smartphones) or cellular network (second, third, and fourth generation). The electrochemical methods that we demonstrate enable quantitative, broadly applicable, and inexpensive sensing with flexibility based on a wide variety of important electroanalytical techniques (chronoamperometry, cyclic voltammetry, differential pulse voltammetry, square wave voltammetry, and potentiometry), each with different uses. Four applications demonstrate the analytical performance of the device: these involve the detection of (i) glucose in the blood for personal health, (ii) trace heavy metals (lead, cadmium, and zinc) in water for in-field environmental monitoring, (iii) sodium in urine for clinical analysis, and (iv) a malarial antigen (Plasmodium falciparum histidine-rich protein 2) for clinical research. The combination of these electrochemical capabilities in an affordable, handheld format that is compatible with any mobile phone or network worldwide guarantees that sophisticated diagnostic testing can be performed by users with a broad spectrum of needs, resources, and levels of technical expertise.


ACS Nano | 2014

Engineering shadows to fabricate optical metasurfaces.

Alex Nemiroski; Mathieu Gonidec; Jerome M. Fox; Philip Jean-Remy; Evan Turnage; George M. Whitesides

Optical metasurfaces-patterned arrays of plasmonic nanoantennas that enable the precise manipulation of light-matter interactions-are emerging as critical components in many nanophotonic materials, including planar metamaterials, chemical and biological sensors, and photovoltaics. The development of these materials has been slowed by the difficulty of efficiently fabricating patterns with the required combinations of intricate nanoscale structure, high areal density, and/or heterogeneous composition. One convenient strategy that enables parallel fabrication of periodic nanopatterns uses self-assembled colloidal monolayers as shadow masks; this method has, however, not been extended beyond a small set of simple patterns and, thus, has remained incompatible with the broad design requirements of metasurfaces. This paper demonstrates a technique-shadow-sphere lithography (SSL)-that uses sequential deposition from multiple angles through plasma-etched microspheres to expand the variety and complexity of structures accessible by colloidal masks. SSL harnesses the entire, relatively unexplored, space of shadow-derived shapes and-with custom software to guide multiangled deposition-contains sufficient degrees of freedom to (i) design and fabricate a wide variety of metasurfaces that incorporate complex structures with small feature sizes and multiple materials and (ii) generate, in parallel, thousands of variations of structures for high-throughput screening of new patterns that may yield unexpected optical spectra. This generalized approach to engineering shadows of spheres provides a new strategy for efficient prototyping and discovery of periodic metasurfaces.


Analytical Chemistry | 2015

Broadly Available Imaging Devices Enable High-Quality Low-Cost Photometry

Dionysios Christodouleas; Alex Nemiroski; Ashok Kumar; George M. Whitesides

This paper demonstrates that, for applications in resource-limited environments, expensive microplate spectrophotometers that are used in many central laboratories for parallel measurement of absorbance of samples can be replaced by photometers based on inexpensive and ubiquitous, consumer electronic devices (e.g., scanners and cell-phone cameras). Two devices, (i) a flatbed scanner operating in transmittance mode and (ii) a camera-based photometer (constructed from a cell phone camera, a planar light source, and a cardboard box), demonstrate the concept. These devices illuminate samples in microtiter plates from one side and use the RGB-based imaging sensors of the scanner/camera to measure the light transmitted to the other side. The broadband absorbance of samples (RGB-resolved absorbance) can be calculated using the RGB color values of only three pixels per microwell. Rigorous theoretical analysis establishes a well-defined relationship between the absorbance spectrum of a sample and its corresponding RGB-resolved absorbance. The linearity and precision of measurements performed with these low-cost photometers on different dyes, which absorb across the range of the visible spectrum, and chromogenic products of assays (e.g., enzymatic, ELISA) demonstrate that these low-cost photometers can be used reliably in a broad range of chemical and biochemical analyses. The ability to perform accurate measurements of absorbance on liquid samples, in parallel and at low cost, would enable testing, typically reserved for well-equipped clinics and laboratories, to be performed in circumstances where resources and expertise are limited.


Proceedings of the National Academy of Sciences of the United States of America | 2014

Noncontact orientation of objects in three-dimensional space using magnetic levitation.

Anand Bala Subramaniam; Dian Yang; Hai-Dong Yu; Alex Nemiroski; Simon Tricard; Audrey K. Ellerbee; Siowling Soh; George M. Whitesides

Significance We describe several noncontact methods of orienting objects in three-dimensional (3D) space using Magnetic Levitation (MagLev), and report the discovery of a sharp geometry-dependent transition of the orientation of levitating objects. An analytical theory of the orientation of arbitrary objects in MagLev explains this transition. MagLev is capable of manipulating and orienting hard and soft objects, and objects of irregular shape. Because controlling the orientation of objects in space is a prerequisite for assembling complex structures from simpler components, this paper extends MagLev into 3D self-assembly, robotic assembly, and noncontact (stiction-free) orientation of hard and soft objects for applications in biomimetics, soft robotics, and stimulus-responsive materials, among others. This paper describes several noncontact methods of orienting objects in 3D space using Magnetic Levitation (MagLev). The methods use two permanent magnets arranged coaxially with like poles facing and a container containing a paramagnetic liquid in which the objects are suspended. Absent external forcing, objects levitating in the device adopt predictable static orientations; the orientation depends on the shape and distribution of mass within the objects. The orientation of objects of uniform density in the MagLev device shows a sharp geometry-dependent transition: an analytical theory rationalizes this transition and predicts the orientation of objects in the MagLev device. Manipulation of the orientation of the levitating objects in space is achieved in two ways: (i) by rotating and/or translating the MagLev device while the objects are suspended in the paramagnetic solution between the magnets; (ii) by moving a small external magnet close to the levitating objects while keeping the device stationary. Unlike mechanical agitation or robotic selection, orienting using MagLev is possible for objects having a range of different physical characteristics (e.g., different shapes, sizes, and mechanical properties from hard polymers to gels and fluids). MagLev thus has the potential to be useful for sorting and positioning components in 3D space, orienting objects for assembly, constructing noncontact devices, and assembling objects composed of soft materials such as hydrogels, elastomers, and jammed granular media.


Advanced Materials | 2015

Using Magnetic Levitation for Non-Destructive Quality Control of Plastic Parts

Jonathan W. Hennek; Alex Nemiroski; Anand Bala Subramaniam; David K. Bwambok; Dian Yang; Daniel V. Harburg; Simon Tricard; Audrey K. Ellerbee; George M. Whitesides

Magnetic levitation (MagLev) enables rapid and non-destructive quality control of plastic parts. The feasibility of MagLev as a method to: i) rapidly assess injection-molded plastic parts for defects during process optimization, ii) monitor the degradation of plastics after exposure to harsh environmental conditions, and iii) detect counterfeit polymers by density is demonstrated.


Analytical Chemistry | 2016

High-Sensitivity Measurement of Density by Magnetic Levitation

Alex Nemiroski; Ashok Kumar; Siowling Soh; Daniel V. Harburg; Hai-Dong Yu; George M. Whitesides

This paper presents methods that use Magnetic Levitation (MagLev) to measure very small differences in density of solid diamagnetic objects suspended in a paramagnetic medium. Previous work in this field has shown that, while it is a convenient method, standard MagLev (i.e., where the direction of magnetization and gravitational force are parallel) cannot resolve differences in density <10(-4) g/cm(3) for macroscopic objects (>mm) because (i) objects close in density prevent each other from reaching an equilibrium height due to hard contact and excluded volume, and (ii) using weaker magnets or reducing the magnetic susceptibility of the medium destabilizes the magnetic trap. The present work investigates the use of weak magnetic gradients parallel to the faces of the magnets as a means of increasing the sensitivity of MagLev without destabilization. Configuring the MagLev device in a rotated state (i.e., where the direction of magnetization and gravitational force are perpendicular) relative to the standard configuration enables simple measurements along the axes with the highest sensitivity to changes in density. Manipulating the distance of separation between the magnets or the lengths of the magnets (along the axis of measurement) enables the sensitivity to be tuned. These modifications enable an improvement in the resolution up to 100-fold over the standard configuration, and measurements with resolution down to 10(-6) g/cm(3). Three examples of characterizing the small differences in density among samples of materials having ostensibly indistinguishable densities-Nylon spheres, PMMA spheres, and drug spheres-demonstrate the applicability of rotated Maglev to measuring the density of small (0.1-1 mm) objects with high sensitivity. This capability will be useful in materials science, separations, and quality control of manufactured objects.


Gastrointestinal Endoscopy | 2011

An implantable wireless biosensor for the immediate detection of upper GI bleeding: a new fluorescein-based tool for diagnosis and surveillance (with video)

Marvin Ryou; Alex Nemiroski; Dan E. Azagury; Sohail N. Shaikh; Michele B. Ryan; Robert M. Westervelt; Christopher C. Thompson

BACKGROUND Early recurrent hemorrhage after endoscopic intervention for acute upper GI bleeding (UGIB) can approach 20% and leads to increased morbidity and mortality. Little has changed over the past several decades regarding immediate posthemorrhage surveillance, and there has likewise been no significant improvement in outcomes. OBJECTIVE To develop and test an endoscopically implantable wireless biosensor for real-time detection of fluorescein-labeled blood in ex vivo and in vivo porcine models of UGIB. SETTING Animal laboratory. DESIGN Benchtop and acute animal studies. SUBJECTS Five pigs. INTERVENTIONS UGIB models were surgically created in living pigs. Biosensors were endoscopically deployed in the stomach using standard endoscopic clips. The ability to detect acute UGIB and estimated blood loss leading to biosensor activation were recorded. Feasibility of wireless data transmission out of the body to an external computer and cell phone was assessed. MAIN OUTCOME MEASUREMENTS Technical feasibility and immediate complications. RESULTS A porcine UGIB model was successfully created. Biosensors were able to detect all acute bleeding events and wirelessly transmit out of the body, and successfully sent an emergency text message to the intended cell phone in all cases. Average estimated blood loss leading to biosensor activation was 30 mL (10-75 mL). LIMITATIONS Animal study; small numbers. CONCLUSIONS An endoscopically implantable wireless biosensor successfully detected acute hemorrhage in a porcine UGIB model and sent an emergency cell-phone alert in real time.


Journal of the American Chemical Society | 2016

Tilted Magnetic Levitation Enables Measurement of the Complete Range of Densities of Materials with Low Magnetic Permeability

Alex Nemiroski; Siowling Soh; Sen Wai Kwok; Hai-Dong Yu; George M. Whitesides


Nano Letters | 2016

Fabrication of Nonperiodic Metasurfaces by Microlens Projection Lithography

Mathieu Gonidec; Mahiar Hamedi; Alex Nemiroski; Luis M. Rubio; Cesar Torres; George M. Whitesides

Collaboration


Dive into the Alex Nemiroski's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Marvin Ryou

Brigham and Women's Hospital

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge