Alexandr E. Urusov
Russian Academy of Sciences
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Alexandr E. Urusov.
Journal of Analytical Chemistry | 2011
Alexandr E. Urusov; S.N. Kostenko; P.G. Sveshnikov; Anatoly V. Zherdev; Boris B. Dzantiev
The detection of mycotoxins—toxic contaminants of fungal origin—is an important problem in the food and feed quality control. An immunochromatographic system was developed for the detection of ochratoxin A (OTA), which is one of the priority contaminants in grain. Monoclonal antibodies against OTA and their conjugates with colloidal gold nanoparticles were prepared. The detection is based on the competition of OTA in a sample and an OTA-protein conjugate immobilized on a test strip for the binding to anti-bodies on the colloidal particle surface. The method was tested in the analysis of plant extracts (maize and barley extracts). It was shown that OTA can be detected in a medium with a high content of an organic solvent (up to 35% of methanol). The disappearance of the line in the test zone is visually detected at OTA concentrations starting from 50 ng/mL. In the case of the video-digital detection of changes in the color intensity of the test zone, the limit of detection of OTA is 5 ng/mL. The duration of the assay is 10 min.
Applied Biochemistry and Microbiology | 2010
Alexandr E. Urusov; Anatoly V. Zherdev; Boris B. Dzantiev
The review is devoted to comparative characterization of immunochemical methods of detection of mycotoxin, which belongs to one of the priority groups of the food contaminants. It has been shown that the high specificity and the possibility of mycotoxin detection in low concentrations combined with existent diverse equipment allow for considering the immunochemical methods of analysis to be the most promising for wide practical application. The analytical characteristics of the existent developments are presented; the merits and demerits of the different kinds of immunoanalytical systems are compared.
Sensors | 2014
Alexandr E. Urusov; Alina V. Petrakova; Maxim V. Vozniak; Anatoly V. Zherdev; Boris B. Dzantiev
The main limitations of microplate-based enzyme immunoassays are the prolonged incubations necessary to facilitate heterogeneous interactions, the complex matrix and poorly soluble antigens, and the significant sample dilutions often required because of the presence of organic extractants. This study presents the use of antibody immobilization on the surface of magnetic particles to overcome these limitations in the detection of the mycotoxin, aflatoxin B1. Features of the proposed system are a high degree of nanoparticle dispersion and methodologically simple immobilization of the antibodies by adsorption. Reactions between the immobilized antibodies with native and labeled antigens are conducted in solution, thereby reducing the interaction period to 5 min without impairing the analytical outcome. Adsorption of immunoglobulins on the surface of magnetic nanoparticles increases their stability in aqueous-organic media, thus minimizing the degree of sample dilution required. Testing barley and maize extracts demonstrated a limit of aflatoxin B1 detection equal to 20 pg/mL and total assay duration of 20 min. Using this method, only the 3-fold dilution of the initial methanol/water (60/40) extraction mixture in the microplate wells is necessary. The proposed pseudo-homogeneous approach could be applied toward immunodetection of a wide range of compounds.
Toxins | 2015
Alexandr E. Urusov; Anatoly V. Zherdev; Alina V. Petrakova; Elchin G. Sadykhov; O. V. Koroleva; Boris B. Dzantiev
Mycotoxins are low molecular weight fungal metabolites that pose a threat as toxic contaminants of food products, thereby necessitating their effective monitoring and control. Microplate ELISA can be used for this purpose, but this method is characteristically time consuming, with a duration extending to several hours. This report proposes a variant of the ELISA method for the detection and quantification of three mycotoxins, ochratoxin A, aflatoxin B1 and zearalenone, in the kinetic regime. The main requirement for the proposed kinetic protocol was to provide a rapid method that combined sensitivity and accuracy. The use of biotin with an extended spacer together with a streptavidin–polyperoxidase conjugate provided high signal levels, despite these interactions occurring under non-equilibrium conditions. Duration of the individual mycotoxin assays was 20 min, whereas the analysis of all three mycotoxins in parallel reached a maximum duration of 25 min. Recovery of at least 95% mycotoxins in water-organic extracts was shown. The developed assays were successfully validated using poultry processing products and corn samples spiked with known quantities of mycotoxins. The detection limits for aflatoxin B1, ochratoxin A and zearalenone in these substances were 0.24, 1.2 and 3 ng/g, respectively.
Applied Biochemistry and Microbiology | 2017
Alina V. Petrakova; Alexandr E. Urusov; Anatoly V. Zherdev; Liqiang Liu; C. Xu; Boris B. Dzantiev
Highly sensitive immunochromatographic test systems were developed for the detection of zearalenone (ZEA) and T-2 toxin (T2T) using magnetite nanoparticles (MNPs) for the labeling. In order to detect an analyte with high sensitivity, the competitive reaction was performed with free specific antibodies, while immune complexes were detected by the reaction with label-conjugated anti-species antibodies. The conditions for the synthesis of magnetite nanoparticles conjugated to anti-species antibodies were optimized. The concentrations of specific reagents that provided the highly sensitive detection of T-2 toxin and zearalenone were found. The instrumental detection limit for the determination of T-2 toxin and zearalenone in baby food samples (oat flakes) was 0.1 and 0.05 ng/mL (2.0 and 1.0 ng/g), respectively. The assay time was 15 min. The results of the present study confirm the possibility of the practical use of magnetite nanoparticles for immunochromatographic assay labeling.
Analytical Methods | 2015
Alina V. Petrakova; Alexandr E. Urusov; Anatoly V. Zherdev; Boris B. Dzantiev
While immunoenzyme assay (ELISA) is widely used for the detection of various compounds, its use is significantly limited by the considerable duration (determined by the heterogeneous reaction to form detectable immune complexes) and the restricted detection limit. This study proposes an ELISA variant based on the application of highly dispersed (average diameter – 10 nm) magnetic iron oxide nanoparticles as carriers for the adsorbable antibodies. In conducting the proposed ELISA, the antibodies react with the detectable compound within the sample volume; the formed complexes are preconcentrated by precipitation in a magnetic field and are used for immunoenzyme detection in the wells of a microplate. This approach has been implemented for the detection of aflatoxin B1, a low molecular weight compound that needs to be controlled at extremely low concentrations due to its high toxicity. Using magnetic nanoparticles provided a 10-fold lowering of the detection limit and cut the test duration by half, compared to conventional ELISA. Immobilized antibodies exhibited high resistance to methanol when testing aqueous/methanol extracts of contaminated vegetable feed stocks (corn kernels), making it possible to identify aflatoxin B1 at concentrations as low as 2 pg ml−1 (40 pg g−1). The proposed approach is universal and can be used for the immunodetection of various compounds.
Nanotechnologies in Russia | 2017
Alexandr E. Urusov; Alina V. Petrakova; Anatoly V. Zherdev; Boris B. Dzantiev
Complexes of magnetic nanoparticles with antibodies are used for the selective and highly sensitive detection in medical diagnostics, environmental monitoring, and the product quality and safety control. Magnetic nanoparticles are applied as controllable carriers to concentrate samples, as a solid phase in assays, or as labels detected by virtue of their magnetic, optical, or other properties. This review covers the results of recent studies, including methods for the preparation of analytical reagents, new assays, and techniques for the detection of magnetic nanoparticles.
Nano Hybrids and Composites Vol | 2017
Alexandr E. Urusov; Alina V. Petrakova; Anatoly V. Zherdev; Boris B. Dzantiev
Magnetic nanoparticles (MNP) are efficient molecular carriers for affine molecules. MNP complexes with antibodies can be used for the selective concentration and highly sensitive detection of various compounds. In this paper, development steps of the enzyme immunoassay using MNP are considered in details. Simple method of MNP synthesis and production of conjugates of antibodies with the aggregated MNP using physical sorption is presented. Simple, yet effective, formats of enzyme immunoassay are given. Using aflatoxin B1 detection as an example, possibility of decreasing detection limit up to 2 pg/mL, with a considerable decrease in the assay time, and performing immune interaction in the media with high organic content is shown.
Applied Biochemistry and Microbiology | 2017
Alexandr E. Urusov; Alina V. Petrakova; A. V. Bartosh; Milyausha K. Gubaydullina; Anatoly V. Zherdev; Boris B. Dzantiev
A new scheme of immunochromatographic assay was developed for the highly sensitive detection of low-molecular-weight analytes. This scheme includes the following two steps: the formation of complexes of free specific antibodies with an antigen and their detection by anti-species antibodies conjugated to gold nanoparticles as the label. This scheme was tested with mycotoxin T-2 toxin in maize extracts. The use of specific antibodies and a label as two individual components made it possible to independently vary their concentrations with a simultaneous decrease in the detection limit and an increase in the color intensity. The assay did not require additional reagents and manipulations. The instrumental and visual detection limits of the designed test system were 0.1 and 5.0 ng/mL, respectively (2 and 90 ng per gram of analytes), which are two orders of magnitude lower compared to conventional immunochromatography using the same reagents.
Moscow University Chemistry Bulletin | 2018
M. K. Gubaidullina; Alexandr E. Urusov; Anatoly V. Zherdev; C. Xu; Boris B. Dzantiev
The traditional immunochromatographic assay using a conjugate of gold nanoparticles with specific ochratoxin A (OTA) antibodies and a new type of assay with indirect labeling using a combination of free antibodies and a conjugate of gold nanoparticles with anti-species antibodies were compared using the example of OTA detection. In the proposed assay, specific antibodies are included in the sample dilution buffer, which increases the duration of their interaction with the antigen, while a conjugate of anti-species antibodies with the marker is applied to the test strip. The assay was approbated for OTA detection in maize extracts. Transition to indirect labeling was shown to reduce the OTA detection limit by two orders of magnitude up to 0.12 ng/mL. The causes of this improvement are discussed. The high sensitivity of immunochromatography with indirect labeling makes it a promising approach for detection of various antigens with low molecular weight.