Alexandra Valsamakis
Johns Hopkins University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Alexandra Valsamakis.
Nature Medicine | 1999
Fernando P. Polack; Paul G. Auwaerter; Sok H. Lee; Hossein C. Nousari; Alexandra Valsamakis; Kristin M. Leiferman; Arwind Diwan; Robert J. Adams; Diane E. Griffin
The severe disease atypical measles occurred when individuals immunized with a poorly protective inactivated vaccine contracted measles, and was postulated to be due to a lack of fusion-inhibiting antibodies. Here, rhesus macaques immunized with formalin-inactivated measles vaccine developed transient neutralizing and fusion-inhibiting antibodies, but no cytotoxic T-cell response. Subsequent infection with measles virus caused an atypical rash and pneumonitis, accompanied by immune complex deposition and an increase in eosinophils. Fusion-inhibiting antibody appeared earlier in these monkeys than in non-immunized monkeys. These data indicate that atypical measles results from previous priming for a nonprotective type 2 CD4 T-cell response rather than from lack of functional antibody against the fusion protein.
Nature Medicine | 2000
Fernando P. Polack; Sok H. Lee; Sallie R. Permar; Elizabeth Manyara; Hossein G. Nousari; Yaikah Jeng; Farah Mustafa; Alexandra Valsamakis; Robert J. Adams; Harriet L. Robinson; Diane E. Griffin
Measles remains a principal cause of worldwide mortality, in part because young infants cannot be immunized effectively. Development of new vaccines has been hindered by previous experience with a formalin-inactivated vaccine that predisposed to a severe form of disease (atypical measles). Here we have developed and tested potential DNA vaccines for immunogenicity, efficacy and safety in a rhesus macaque model of measles. DNA protected from challenge with wild-type measles virus. Protection correlated with levels of neutralizing antibody and not with cytotoxic T lymphocyte activity. There was no evidence in any group, including those receiving hemagglutinin-encoding DNA alone, of ‘priming’ for atypical measles.
Clinical Microbiology Reviews | 2007
Alexandra Valsamakis
SUMMARY Hepatitis B virus (HBV) is an enveloped virus with a small (3.2-kb) partially double-stranded DNA genome that causes acute and chronic infections. The impact of these infections on public health worldwide is enormous, with an estimated prevalence of 2 billion acute infections and 360 million chronic infections globally. This review focuses on chronic hepatitis B and the molecular assays used in its diagnosis and management. Background information, including that about features of the hepatitis B virion, viral replication, and epidemiology of infection, that is important for understanding chronic hepatitis B and molecular diagnostic tests for HBV is provided. To facilitate an understanding of the utility of molecular testing for chronic hepatitis B, the four stages of chronic hepatitis B infection that are currently recognized, as well as an additional entity, occult hepatitis B, that can be diagnosed only by sensitive nucleic acid amplification methods, are reviewed in detail, including available therapeutic agents. The molecular diagnostic content focuses on tests for HBV DNA quantification, genotyping, and mutation detection (including precore/core promoter and antiviral resistance mutations). The discussion of these tests encompasses their current utility and performance characteristics, drawing from current clinical guidelines and other studies from the literature. In recognition of the continual evolution of this field, the final section describes emerging molecular markers with future diagnostic potential.
Journal of Clinical Microbiology | 2003
Julia H. Knepp; Melissa A. Geahr; Michael Forman; Alexandra Valsamakis
ABSTRACT Automated nucleic acid extraction is an attractive alternative to labor-intensive manual methods. We compared two automated methods, the BioRobot M48 instrument (Qiagen, Inc.) and MagNA Pure (Roche Applied Sciences) methods, to two manual methods, the QIAamp Viral RNA Mini kit (Qiagen) and TRIzol (Invitrogen), for the extraction of enterovirus RNA. Analytical sensitivity was assessed by dilution analysis of poliovirus type 2 Sabin in cerebrospinal fluid. The sensitivity of PCR was equivalent after RNA extraction with QIAamp, BioRobot M48, and MagNA Pure. All 18 replicates of 100 PFU/ml were detected after extraction by the four methods. Fewer replicates of each successive dilution were detected after extraction by each method. At 10−1 PFU/ml, 17 of 18 replicates were positive by QIAamp, 15 of 18 replicates were positive by BioRobot M48, and 12 of 18 replicates were positive by MagNA Pure; at 10−2 PFU/ml, 4 of 17 replicates were positive by QIAamp, 2 of 18 replicates were positive by BioRobot M48, and 0 of 18 replicates were positive by MagNA Pure. At 10−3 PFU/ml, no replicates were detected. Evaluation of TRIzol was discontinued after nine replicates due to a trend of lower sensitivity (at 10−3 PFU/ml eight of nine replicates were positive at 100 PFU/ml, four of nine replicates were positive at 10−1 PFU/ml, and zero of nine replicates were positive at 10−2 PFU/ml). Concordant results were obtained in 24 of 28 clinical specimens after extraction by all methods. No evidence of contamination was observed after extraction by automated instruments. The data indicate that the sensitivity of enterovirus PCR is largely similar after extraction by QIAamp, BioRobot M48, and MagNA Pure; a trend of decreased sensitivity was observed after TRIzol extraction. However, the results of enterovirus PCR were largely concordant in patient samples, indicating that the four extraction methods are suitable for detection of enteroviruses in clinical specimens.
Gastroenterology | 2011
Kathleen B. Schwarz; Regino P. Gonzalez-Peralta; Karen F. Murray; Jean P. Molleston; Barbara Haber; Maureen M. Jonas; Philip J. Rosenthal; Parvathi Mohan; William F. Balistreri; Michael R. Narkewicz; Lesley J. Smith; Steven J. Lobritto; Stephen J. Rossi; Alexandra Valsamakis; Zachary D. Goodman; Patricia R. Robuck; Bruce A. Barton
BACKGROUND & AIMS Although randomized trials of adults infected with hepatitis C virus (HCV) have shown that ribavirin increases the efficacy of pegylated interferon (PEG), such trials have not been performed in children. We conducted a randomized controlled trial of PEG and ribavirin, compared with PEG and placebo, in children 5 to 17 years old with chronic hepatitis C. METHODS HCV RNA-positive children from 11 university medical centers were randomly assigned to receive either PEG alfa-2a (PEG-2a; 180 μg/1.73 m(2) body surface area, subcutaneously each week; n = 55) and ribavirin (15 mg/kg orally in 2 doses daily) or PEG-2a and placebo (n = 59) for 48 weeks. The primary end point was sustained virologic response (SVR; lack of detectable HCV RNA at least 24 weeks after stopping therapy). RESULTS SVR was achieved in 53% of children treated with PEG-2a and ribavirin, compared with 21% of children who received PEG-2a and placebo (P < .001). Early virologic response (HCV RNA reduction >2 log(10) IU at 12 weeks) had a negative predictive value of only 0.89 in children with genotype 1, indicating that these children might benefit from 24 weeks of therapy before stopping treatment. Side effects, especially neutropenia, led to dose modification in 40% of children. Eighty-two percent of the PEG/ribavirin and 86% of the PEG/placebo group were in compliance with the year 2 follow-up visit; the durability of virologic response was 100% in both groups. CONCLUSIONS The combination of PEG and ribavirin is superior to PEG and placebo as therapy for chronic hepatitis C in children and adolescents.
Journal of Clinical Microbiology | 2008
R. T. Hayden; Kristin M. Hokanson; S. B. Pounds; Susan Belzer; J. Carr; D. Diorio; Michael Forman; Yagnya Joshi; David R. Hillyard; Richard L. Hodinka; M. N. Nikiforova; Charlotte A. Romain; Jeffery Stevenson; Alexandra Valsamakis; Henry H. Balfour
ABSTRACT Quantification of Epstein-Barr virus (EBV) in peripheral blood is important for the diagnosis and management of serious EBV diseases, including posttransplant lymphoproliferative disorder. A variety of PCR-based methods are currently in use; however, there is little information on their comparability. This study assessed the relative performance of different quantitative assays. A multicenter comparative study was performed at eight sites using three panels consisting of serial dilutions of quantified EBV DNA and extracts from a total of 19 whole-blood specimens. Samples were distributed and tested blindly. Instrumentation, probe chemistries, amplification targets, and other test-related aspects varied considerably between laboratories. Each laboratorys calibration curve indicated strong evidence of a consistent log-linear relationship between viral load and cycle threshold, suggesting that intralaboratory tracking of a given patient would yield similar relative quantitative trends among the participating test sites. There was strong concordance among laboratories with respect to qualitative test results; however, marked quantitative discordance was seen. For most samples, the across-laboratory interquartile range of the reported viral load (in copies/μl) was roughly 0.6 log-units, and for one sample the overall range was approximately 4.2 log-units. While intralaboratory tracking of patients may yield similar results, these data indicate a need for caution when attempting to compare clinical results obtained at different institutions and suggest the potential value to be gained by more standardized testing methodology.
Journal of Clinical Microbiology | 2004
Tarek Elbeik; Johan Surtihadi; Mark Destree; Jed Gorlin; Mark Holodniy; Saeed A. Jortani; Ken Kuramoto; Valerie L. Ng; Roland Valdes; Alexandra Valsamakis; Norah A. Terrault
ABSTRACT In this multicenter evaluation, the VERSANT HCV RNA 3.0 Assay (bDNA) (Bayer Diagnostics, Tarrytown, N.Y.) was shown to have excellent reproducibility, linearity, and analytical sensitivity across specimen collection matrices (serum, EDTA, ACD-A), and hepatitis C virus (HCV) genotypes 1 to 6. The VERSANT HCV bDNA Assay has a reportable range of 615 to 7,690,000 (7.69 × 106) IU/ml. The total coefficient of variation (CV) ranged from 32.4% at 615 IU/ml to 17% at 6.8 × 106 IU/ml. The assay was linear across the reportable range. Analytical specificity of 98.8% was determined by testing 999 specimens from volunteer blood donors. Evaluation of HCV genotypes using RNA transcripts of representative clones of 1a, 1b, 2a, 2b, 2c, 3a, 4a, 5a, and 6a and patient specimens showed that the largest difference between genotype 1, upon which the assay is standardized, and non-1 genotypes was within 1.5-fold. Testing of potentially interfering endogenous substances and exogenous substances and conditions found no interference in HCV-positive or HCV-negative specimens except for unconjugated bilirubin at concentrations of ≥20 mg/dl and protein at concentrations of ≥9 g/dl. Biological variability was estimated from 29 clinically stable individuals not on HCV therapy who were tested weekly over an 8-week period. The combined estimate of total (biologic plus assay) variability was 0.15 log10 standard deviation (CV, 36.1%), a fold change of 2.6. Thus, the observed fold change between any two consecutive HCV RNA measures is expected to be less than 2.6-fold (equivalent to 0.41 log10 IU/ml) 95% of the time in clinically stable individuals.
Clinical Infectious Diseases | 2013
Hans H. Hirsch; Irmeli Lautenschlager; Benjamin A. Pinsky; Laura Cardeñoso; Shagufta Aslam; Bryan Cobb; Regis A. Vilchez; Alexandra Valsamakis
A new quantitative polymerase chain reaction assay, COBAS AmpliPrep/COBAS TaqMan CMV Test, was developed using the first World Health Organization cytomegalovirus standard. It demonstrated a high level of interlaboratory agreement and precision compared to quantitative results obtained with tests used by 5 different laboratories.
Clinical Infectious Diseases | 2012
Hans H. Hirsch; Irmeli Lautenschlager; Benjamin A. Pinsky; Laura Cardeñoso; Shagufta Aslam; Bryan Cobb; Regis A. Vilchez; Alexandra Valsamakis
A new quantitative polymerase chain reaction assay, COBAS AmpliPrep/COBAS TaqMan CMV Test, was developed using the first World Health Organization cytomegalovirus standard. It demonstrated a high level of interlaboratory agreement and precision compared to quantitative results obtained with tests used by 5 different laboratories.
Journal of Clinical Microbiology | 2006
Angela M. Caliendo; Alexandra Valsamakis; Ye E. Zhou; Belinda Yen-Lieberman; Janet Andersen; Stephen Young; Andrea Ferreira-Gonzalez; Gregory J. Tsongalis; Richard B. Pyles; James W. Bremer; Nell S. Lurain
ABSTRACT We report a multilaboratory evaluation of hepatitis C virus (HCV) viral load assays to determine their linear range, reproducibility, subtype detection, and agreement. A panel of HCV RNA samples ranging in nominal concentration from 1.0 to 7.0 log10 IU/ml was constructed by diluting a clinical specimen (genotype 1b). Replicates of the panel were tested in multiple laboratories using the Abbott TaqMan analyte-specific reagent (Abbott reverse transcription-PCR [RT-PCR]), Roche TaqMan RUO (Roche RT-PCR), Roche Amplicor Monitor HCV 2.0 (Roche Monitor), and Bayer VERSANT HCV RNA 3.0 (Bayer bDNA) assays. Bayer bDNA-negative specimens were tested reflexively using the Bayer VERSANT HCV RNA qualitative assay (Bayer TMA). Abbott RT-PCR and Roche RT-PCR detected all 28 replicates with a concentration of 1.0 log10 IU/ml and were linear to 7.0 log10 IU/ml. Roche Monitor and Bayer bDNA detected 27 out of 28 and 13 out of 28 replicates, respectively, of 3.0 log10 IU/ml. Bayer TMA detected all seven replicates with 1.0 log10 IU/ml. Bayer bDNA was the most reproducible of the four assays. The mean viral load values for panel members in the linear ranges of the assays were within 0.5 log10 for the different tests. Eighty-nine clinical specimens of various genotypes (1 through 4) were tested in the Bayer bDNA, Abbott RT-PCR, and Roche RT-PCR assays. For Abbott RT-PCR, mean viral load values were 0.61 to 0.96 log10 greater than the values for Bayer bDNA assay for samples with genotype 1, 2, or 3 samples and 0.08 log10 greater for genotype 4 specimens. The Roche RT-PCR assay gave mean viral load values that were 0.28 to 0.82 log10 greater than those obtained with the Bayer bDNA assay for genotype 1, 2, and 3 samples. However, for genotype 4 samples the mean viral load value obtained with the Roche RT-PCR assay was, on average, 0.15 log10 lower than that of the Bayer bDNA. Based on these data, we conclude that the sensitivity and linear range of the Abbott and Roche RT-PCR assays enable them to be used for HCV diagnostics and therapeutic monitoring. However, the differences in the viral load values obtained with the different assays underscore the importance of using one assay when monitoring response to therapy.