Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Alfons Torrego is active.

Publication


Featured researches published by Alfons Torrego.


Respirology | 2014

Diagnostic yield of transbronchial cryobiopsy in interstitial lung disease: A randomized trial

Virginia Pajares; Carmen Puzo; Diego Castillo; Enrique Lerma; M. Angeles Montero; David Ramos-Barbón; Óscar Amor-Carro; Angels Gil de Bernabé; Tomás Franquet; Vicente Plaza; J. Hetzel; J. Sanchis; Alfons Torrego

Transbronchial lung biopsy (TBLB) is required for evaluation in selected patients with interstitial lung disease (ILD). The diagnostic yield of histopathologic assessment is variable and is influenced by factors such as the size of samples and the presence of crush artefacts left by conventional biopsy forceps. We compared the diagnostic yield and safety of TBLB with cryoprobe sampling versus conventional forceps sampling.


Archivos De Bronconeumologia | 2010

Utilización de criosondas para la realización de la biopsia pulmonar transbronquial

Virginia Pajares; Alfons Torrego; Carmen Puzo; Enrique Lerma; Maria Àngels Gil de Bernabé; Tomás Franquet

BACKGROUND AND OBJECTIVES Transbronchial lung biopsy (TBLB) is a bronchoscopy procedure used to obtain peripheral lung tissue. Small size samples and artefacts lead to variable, and usually poor, diagnostic yield. The use of cryoprobes may enable larger size and better quality biopsy samples to be obtained. The purpose of this study was to evaluate the feasibility of TBLB with cryoprobes and analyse the histological quality of samples obtained. PATIENTS AND METHODS We selected 10 patients with interstitial lung disease who were suitable for TBLB. A cryoprobe (Erbokryo CA, Erbe, Germany) was introduced through the bronchoscope work channel. Then, under fluoroscopic control, the cryoprobe was placed in an area of the peripheral lung previously selected according to CT findings. A temperature of -89.5 degrees C was applied for 3s and the cryoprobe and bronchoscope were removed with the frozen lung sample attached to the probe. The procedure was performed under sedation and the patient was intubated to allow bronchoscope and cryoprobe removal. Safety, duration of the procedure and histological findings has been evaluated. RESULTS There were 10 patients (64+/-8 years, 6 males). Procedure length was 35 min. The specimen area was 9.5 mm2 (range 3 to 25 mm2) and the mean number of alveolar spaces was 29.62. No pneumothorax was registered. 6/10 patients had mild post-biopsy bleeding controlled with standard bronchoscopy measures. CONCLUSIONS The use of cryoprobes for TBLB may become an alternative technique to increase diagnostic yield.


International Journal of Chronic Obstructive Pulmonary Disease | 2015

What pulmonologists think about the asthma-COPD overlap syndrome.

Marc Miravitlles; Bernardino Alcázar; Francisco Álvarez; Teresa Bazús; Myriam Calle; Ciro Casanova; Carolina Cisneros; Juan P. de-Torres; Luis Manuel Entrenas; Cristóbal Esteban; Patricia García-Sidro; Borja G. Cosío; Arturo Huerta; Milagros Iriberri; José Luis Izquierdo; Antolín López-Viña; José Luis López-Campos; Eva Martínez-Moragón; Luis Pérez de Llano; M. Perpiñá; José Antonio Ros; José Serrano; Juan José Soler-Cataluña; Alfons Torrego; Isabel Urrutia; Vicente Plaza

Background Some patients with COPD may share characteristics of asthma; this is the so-called asthma–COPD overlap syndrome (ACOS). There are no universally accepted criteria for ACOS, and most treatments for asthma and COPD have not been adequately tested in this population. Materials and methods We performed a survey among pulmonology specialists in asthma and COPD aimed at collecting their opinions about ACOS and their attitudes in regard to some case scenarios of ACOS patients. The participants answered a structured questionnaire and attended a face-to-face meeting with the Metaplan methodology to discuss different aspects of ACOS. Results A total of 26 pulmonologists with a mean age of 49.7 years participated in the survey (13 specialists in asthma and 13 in COPD). Among these, 84.6% recognized the existence of ACOS and stated that a mean of 12.6% of their patients might have this syndrome. In addition, 80.8% agreed that the diagnostic criteria for ACOS are not yet well defined. The most frequently mentioned characteristics of ACOS were a history of asthma (88.5%), significant smoking exposure (73.1%), and postbronchodilator forced expiratory volume in 1 second/forced vital capacity <0.7 (69.2%). The most accepted diagnostic criteria were eosinophilia in sputum (80.8%), a very positive bronchodilator test (69.2%), and a history of asthma before 40 years of age (65.4%). Up to 96.2% agreed that first-line treatment for ACOS was the combination of a long-acting β2-agonist and inhaled steroid, with a long-acting antimuscarinic agent (triple therapy) for severe ACOS. Conclusion Most Spanish specialists in asthma and COPD agree that ACOS exists, but the diagnostic criteria are not yet well defined. A previous history of asthma, smoking, and not fully reversible airflow limitation are considered the main characteristics of ACOS, with the most accepted first-line treatment being long-acting β2-agonist/inhaled corticosteroids.


Medical Engineering & Physics | 2013

In vivo electrical bioimpedance characterization of human lung tissue during the bronchoscopy procedure. A feasibility study

Benjamin Sanchez; Gerd Vandersteen; Irene Martin; Diego Castillo; Alfons Torrego; Pere J. Riu; Johan Schoukens; Ramon Bragós

Lung biopsies form the basis for the diagnosis of lung cancer. However, in a significant number of cases bronchoscopic lung biopsies fail to provide useful information, especially in diffuse lung disease, so more aggressive procedures are required. Success could be improved using a guided electronic biopsy based on multisine electrical impedance spectroscopy (EIS), a technique which is evaluated in this paper. The theoretical basis of the measurement method and the instrument developed are described, characterized and calibrated while the performance of the instrument is assessed by experiments to evaluate the noise and nonlinear source of errors from measurements on phantoms. Additional preliminary results are included to demonstrate that it is both feasible and safe to monitor in vivo human lung tissue electrical bioimpedance (EBI) during the bronchoscopy procedure. The time required for performing bronchoscopy is not extended because the bioimpedance measurements, present no complications, tolerance problems or side effects among any of the patients measured.


Respiratory Medicine | 2014

Identification of airway bacterial colonization by an electronic nose in Chronic Obstructive Pulmonary Disease

Oriol Sibila; Laia Garcia-Bellmunt; Jordi Giner; Jose Luis Merino; Guillermo Suarez-Cuartin; Alfons Torrego; Ingrid Solanes; Diego Castillo; Jose Luis Valera; Borja G. Cosío; Vicente Plaza; Alvar Agusti

BACKGROUND Airway bacterial colonization by potentially pathogenic microorganisms occurs in a proportion of patients with Chronic Obstructive Pulmonary Disease (COPD). It increases airway inflammation and influences outcomes negatively. Yet, its diagnosis in clinical practice is not straightforward. The electronic nose is a new non-invasive technology capable of distinguishing volatile organic compound (VOC) breath-prints in exhaled breath. We aim to explore if an electronic nose can reliably discriminate COPD patients with and without airway bacterial colonization. METHODS We studied 37 clinically stable COPD patients (67.8 ± 5.2 yrs, FEV1 41 ± 10% ref.) and 13 healthy controls (62.8 ± 5.2 yrs, FEV1 99 ± 10% ref.). The presence of potentially pathogenic microorganisms in the airways of COPD patients (n = 10, 27%) was determined using quantitative bacterial cultures of protected specimen brush. VOCs breath-prints were analyzed by discriminant analysis on principal component reduction, resulting in cross-validated accuracy values. Area Under Receiver Operating Characteristics (AUROC) was calculated using multiple logistic regression. RESULTS Demographic, functional and clinical characteristics were similar in colonized and non-colonized COPD patients but their VOC breath-prints were different (accuracy 89%, AUROC 0.92, p > 0.0001). Likewise, VOCs breath-prints from colonized (accuracy 88%, AUROC 0.98, p < 0.0001) and non-colonized COPD patients (accuracy 83%, AUROC 0.93, p < 0.0001) were also different from controls. CONCLUSIONS An electronic nose can identify the presence of airway bacterial colonization in clinically stable patients with COPD.


European Respiratory Journal | 2017

Th-2 signature in chronic airway diseases: towards the extinction of asthma−COPD overlap syndrome?

Borja G. Cosío; Luis Pérez de Llano; Antolín López Viña; Alfons Torrego; José Luis López-Campos; Joan B. Soriano; Eva Martinez Moragon; José Luis Izquierdo; Irina Bobolea; Javier Callejas; Vicente Plaza; Marc Miravitlles; Juan Jose Soler-Catalunya

We aimed to describe the differences and similarities between patients with chronic obstructive airway disease classified on the basis of classical diagnostic labels (asthma, chronic obstructive pulmonary disease (COPD), or asthma–COPD overlap (ACOS)) or according to the underlying inflammatory pattern (Th-2 signature, either Th-2-high or Th-2-low). We performed a cross-sectional study of patients aged ≥40 years and with a post-bronchodilator forced expiratory volume in 1 s to forced vital capacity ratio ≤0.7 with a previous diagnosis of asthma (non-smoking asthmatics (NSA)), COPD or ACOS, the latter including both smoking asthmatics (SA) and patients with eosinophilic COPD (COPD-e). Clinical, functional and inflammatory parameters (blood eosinophil count, IgE and exhaled nitric oxide fraction (FeNO)) were compared between groups. Th-2 signature was defined by a blood eosinophil count ≥300 cells·μL−1 and/or a sputum eosinophil count ≥3%. Overall, 292 patients were included in the study: 89 with COPD, 94 NSA and 109 with ACOS (44 SA and 65 with COPD-e). No differences in symptoms or exacerbation rate were found between the three groups. With regards the underlying inflammatory pattern, 94 patients (32.2%) were characterised as Th-2-high and 198 (67.8%) as Th-2-low. The Th-2 signature was found in 49% of NSA, 3.3% of patients with COPD, 30% of SA and 49.3% of patients with COPD-e. This classification yielded significant differences in demographic, functional and inflammatory characteristics. We conclude that a classification based upon the inflammatory profile, irrespective of the taxonomy, provides a more clear distinction of patients with chronic obstructive airway disease. Identifying a Th-2 signature in patients with chronic airflow limitation effectively differentiates treatable traits http://ow.ly/kq1E309MMkt


Annals of the American Thoracic Society | 2016

Airway Mucin 2 Is Decreased in Patients with Severe Chronic Obstructive Pulmonary Disease with Bacterial Colonization

Oriol Sibila; Laia Garcia-Bellmunt; Jordi Giner; Ana Rodrigo-Troyano; Guillermo Suarez-Cuartin; Alfons Torrego; Diego Castillo; Ingrid Solanes; Eder Mateus; Silvia Vidal; Ferran Sanchez-Reus; Ernest Sala; Borja G. Cosío; Marcos I. Restrepo; Antonio Anzueto; James D. Chalmers; Vicente Plaza

RATIONALE Mucins are essential for airway defense against bacteria. We hypothesized that abnormal secreted airway mucin levels would be associated with bacterial colonization in patients with severe chronic obstructive pulmonary disease (COPD) Objectives: To investigate the relationship between mucin levels and the presence of potentially pathogenic micro-organisms in the airways of stable patients with severe COPD Methods: Clinically stable patients with severe COPD were examined prospectively. All patients underwent a computerized tomography scan, lung function tests, induced sputum collection, and bronchoscopy with bronchoalveolar lavage (BAL) and protected specimen brush. Patients with bronchiectasis were excluded. Secreted mucins (MUC2, MUC5AC, and MUC5B) and inflammatory markers were assessed in BAL and sputum by ELISA. MEASUREMENTS AND MAIN RESULTS We enrolled 45 patients, with mean age (±SD) of 67 (±8) years and mean FEV1 of 41 (±10) % predicted. A total of 31% (n = 14) of patients had potentially pathogenic micro-organisms in quantitative bacterial cultures of samples obtained by protected specimen brush. Patients with COPD with positive cultures had lower levels of MUC2 both in BAL (P = 0.02) and in sputum (P = 0.01). No differences in MUC5B or MUC5AC levels were observed among the groups. Lower MUC2 levels were correlated with lower FEV1 (r = 0.32, P = 0.04) and higher sputum IL-6 (r = -0.40, P = 0.01). CONCLUSIONS Airway MUC2 levels are decreased in patients with severe COPD colonized by potentially pathogenic micro-organisms. These findings may indicate one of the mechanisms underlying airway colonization in patients with severe COPD. Clinical trial registered with www.clinicaltrials.gov (NCT01976117).


Respiration | 2015

Usefulness of the Exhaled Breath Temperature Plateau in Asthma Patients

Astrid Crespo Lessmann; Jordi Giner; Alfons Torrego; Eder Mateus; Montserrat Torrejón; Alicia Belda; Vicente Plaza

Background: Exhaled breath temperature (EBT) has recently been proposed as a noninvasive marker of bronchial inflammation in patients with asthma. However, the usefulness of EBT in everyday clinical practice is not well established. Results to date are contradictory and are mainly derived from small, pediatric populations. A comparison of results is further complicated by the use of different equipment and measurements. Objective: We performed a comprehensive study to determine whether EBT is related to asthma control, disease severity, bronchial obstruction, or bronchial inflammation. Methods: Sixty-nine patients on maintenance treatment for asthma were included in a cross-sectional study. At the same visit, we measured the EBT plateau (EBTp) using an X-halo Breath Thermometer (Delmedica, Singapore), the fraction of exhaled nitric oxide (FeNO), spirometry, and inflammatory cell count in induced sputum, and we administered the Asthma Control Test questionnaire. Results: No significant differences were found between EBTp measurements and the level of asthma control, disease severity, bronchial obstruction, FeNO levels, or inflammatory asthma phenotypes. We found a significant difference between EBTp and gender. The EBTp was 34.07°C (SD 0.74) in women and 34.38°C (0.46) in men (p = 0.038). We also found a significant correlation between EBTp measurements and the induced sputum eosinophil count (R = -0.348, p = 0.003). Conclusions: The results of this study do not support the usefulness of the EBTp in asthma management in routine clinical practice. Further research using standardized methods is needed to determine the potential use of the EBTp measurement in asthma management.


Current Respiratory Care Reports | 2014

Transbronchial cryobiopsy in diffuse lung disease

Alfons Torrego; Virginia Pajares

Transbronchial biopsy is required for evaluation of some patients with interstitial lung disease (ILD). The diagnostic success of histopathologic assessment is variable, and affected by such factors as specimen size and the presence of crush artifact attributable to the use of conventional biopsy forceps. Use of cryoprobes to perform transbronchial biopsy enables larger and better quality samples to be obtained compared with conventional methods. The safety profile of transbronchial cryobiopsy is similar to that of transbronchial biopsy with forceps. Diagnostic success of histopathology seems higher when the cryoprobe is used although multidisciplinary agreement with close interaction between clinicians, radiologist, and pathologist is essential to assess the utility of this transbronchial procedure. Larger multisite randomized trials are required to confirm the potential benefits of transbronchial cryobiopsy.


Case Reports | 2010

Influenza A (H1N1) organising pneumonia

Alfons Torrego; Virginia Pajares; Anna Mola; Enrique Lerma; Tomás Franquet

In November 2009, countries around the world reported confirmed cases of pandemic influenza H1N1, including over 6000 deaths. No peak in activity has been seen. The most common causes of death are pneumonia and acute respiratory distress syndrome. We report a case of a 55-year-old woman who presented with organising pneumonia associated with influenza A (H1N1) infection confirmed by transbronchial lung biopsy. Organising pneumonia should also be considered as a possible complication of influenza A (H1N1) infection, given that these patients can benefit from early diagnosis and appropriate specific management.

Collaboration


Dive into the Alfons Torrego's collaboration.

Top Co-Authors

Avatar

Virginia Pajares

Autonomous University of Barcelona

View shared research outputs
Top Co-Authors

Avatar

Vicente Plaza

Autonomous University of Barcelona

View shared research outputs
Top Co-Authors

Avatar

Diego Castillo

Autonomous University of Barcelona

View shared research outputs
Top Co-Authors

Avatar

Enrique Lerma

Autonomous University of Barcelona

View shared research outputs
Top Co-Authors

Avatar

Borja G. Cosío

Instituto de Salud Carlos III

View shared research outputs
Top Co-Authors

Avatar

Carmen Puzo

Autonomous University of Barcelona

View shared research outputs
Top Co-Authors

Avatar

Jordi Giner

Autonomous University of Barcelona

View shared research outputs
Top Co-Authors

Avatar

Eder Mateus

Autonomous University of Barcelona

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Luis Pérez de Llano

University of Santiago de Compostela

View shared research outputs
Researchain Logo
Decentralizing Knowledge