Allan J. Rasmussen
Purdue University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Allan J. Rasmussen.
Meat Science | 2000
J. C. Forrest; Mark T. Morgan; Claus Borggaard; Allan J. Rasmussen; Bo L Jespersen; Jan Rud Andersen
Two different technologies were tested on the slaughterline for their ability to predict drip loss at 24 h, namely near infrared reflectance (NIR) and impedance measurements using a tetra polar measuring geometry at a frequency of 1000 Hz. The results demonstrate that NIR measurements (900-1800 nm) acquired during a 6 min period starting only 30 min post exsanguination through a fibre optic probe in combination with multivariate data analysis can be used for predicting drip loss 24 h after slaughter. A correlation higher than 0.8 was observed for a trial on 99 carcasses measured at a commercial slaughterhouse. The tetrapolar impedance measurements did not perform as well as NIR yielding a correlation of 0.5 with 24 h drip loss.
Meat Science | 1999
Jan Rud Andersen; Claus Borggaard; Allan J. Rasmussen; Lars Plejdrup Houmøller
The pH changes occurring in a carcass during the first 24 h after slaughter are important for the quality of the final meat or meat products. Protein denaturation will occur if pH falls to too low a level or if a relatively low pH sets in at a time after slaughter where the carcass temperature is still high. This will result in meat with poor water holding capacity and in extreme cases in meat that is PSE. pH is measured electrochemically using either glass or solid state (IS-FET) electrodes. However, electrochemically based methods are slow to use and do not offer good precision on unhomogenized meat. In this work it has been investigated whether pH can be measured spectroscopically in reflectance using the visual and near infrared spectral regions. On a limited number of pig meat samples (46 longissimus dorsi and 46 semimembranosus muscles) correlations of 0.85 have been achieved using the fast spectroscopic techniques opposed to glass electrode measurements done in duplicate. The prediction errors for the spectroscopic techniques are found to be comparable to the precision of the reference method.
Archive | 1998
Claus Borggaard; Allan J. Rasmussen
Archive | 2000
Claus Borggaard; Lars Bager Christensen; Knut Erik Gulbrandsen; Allan J. Rasmussen
Archive | 1998
Jan Rud Andersen; J. C. Forrest; Claus Borggaard; Allan J. Rasmussen
Archive | 1991
Claus Borggaard; Allan J. Rasmussen
Archive | 2005
Niels Lynge Madsen; Claus Borggaard; Allan J. Rasmussen
Archive | 1997
Jan Rud Andersen; J. C. Forrest; Claus Borggaard; Allan J. Rasmussen
Archive | 1997
Allan J. Rasmussen; Claus Borggaard; Torben Leo Nielsen; Niels T. Madsen
Archive | 1997
Jan Rud Andersen; J. C. Forrest; Claus Borggaard; Allan J. Rasmussen