Amandine Dispas
University of Liège
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Amandine Dispas.
Journal of Chromatography A | 2012
Jérémie Kindenge Mbinze; Pierre Lebrun; Benjamin Debrus; Amandine Dispas; N. Kalenda; J. Mavar Tayey Mbay; T. Schofield; Bruno Boulanger; Eric Rozet; Ph. Hubert; R.D. Marini
In the context of the battle against counterfeit medicines, an innovative methodology has been used to develop rapid and specific high performance liquid chromatographic methods to detect and determine 18 non-steroidal anti-inflammatory drugs, 5 pharmaceutical conservatives, paracetamol, chlorzoxazone, caffeine and salicylic acid. These molecules are commonly encountered alone or in combination on the market. Regrettably, a significant proportion of these consumed medicines are counterfeit or substandard, with a strong negative impact in countries of Central Africa. In this context, an innovative design space optimization strategy was successfully applied to the development of LC screening methods allowing the detection of substandard or counterfeit medicines. Using the results of a unique experimental design, the design spaces of 5 potentially relevant HPLC methods have been developed, and transferred to an ultra high performance liquid chromatographic system to evaluate the robustness of the predicted DS while providing rapid methods of analysis. Moreover, one of the methods has been fully validated using the accuracy profile as decision tool, and was then used for the quantitative determination of three active ingredients and one impurity in a common and widely used pharmaceutical formulation. The method was applied to 5 pharmaceuticals sold in the Democratic Republic of Congo. None of these pharmaceuticals was found compliant to the European Medicines Agency specifications.
Journal of Chromatography A | 2014
Amandine Dispas; Pierre Lebrun; Eric Ziemons; Roland D. Marini; Eric Rozet; Philippe Hubert
Recently, the number of papers about SFC increased drastically but scientists did not truly focus their work on quantitative performances of this technique. In order to prove the potential of UHPSFC, the present work discussed about the different steps of the analytical life cycle of a method: from development to validation and application. Moreover, the UHPSFC quantitative performances were evaluated in comparison with UHPLC, which is the main technique used for quality control in the pharmaceutical industry and then could be considered as a reference. The methods were developed using Design Space strategy, leading to the optimization of robust method. In this context, when the Design Space optimization shows guarantee of quality, no more robustness study is required prior to the validation. Then, the methods were geometrically transferred in order to reduce the analysis time. The UHPSFC and UHPLC methods were validated based on the total error approach using accuracy profile. Even if UHPLC showed better precision and sensitivity, UHPSFC method is able to give accurate results in a dosing range larger than the 80-120% range required by the European Medicines Agency. Consequently, UHPSFC results are valid and could be used for the control of active substance in a finished pharmaceutical product. Finally, UHPSFC validated method was used to analyse real samples and gave similar results than the reference method (UHPLC).
Journal of Chromatography A | 2012
Amandine Dispas; Pierre Lebrun; Patrick Sassiat; Eric Ziemons; Didier Thiébaut; Jérôme Vial; Philippe Hubert
In the context of green analytical chemistry, a supercritical fluid chromatography method was developed. In order to prove the potential of this technology, a worst case was selected, i.e. the separation of very polar compounds. For that purpose, an innovative methodology based on design of experiments (DoE) and design space (DS) was previously developed and successfully tested on liquid chromatography. For the first time, this methodology was applied to a supercritical fluid chromatography (SFC) separation. First, a screening design was used to select the stationary phase and the nature of the mobile phase based on a maximization of the number of peaks eluted and a minimization of the number of co-eluted peaks. Then, a central composite design with orthogonal blocks defined a set of experiments used to model the retention times of each peak at the beginning, the apex, and the end. The gradient slope, the isocratic plateau before the gradient, the temperature, and the concentration of trifluoroacetic acid (TFA) in the mobile phase were the potentially influential factors. The critical quality attributes (CQAs), i.e. the separation (S) between peaks of the most critical pair, and the analysis time were the criteria considered to assess the quality of the separation. The DS was computed as the multidimensional subspace where the probability for the separation and analysis time criteria to be within acceptance limits was higher than a defined quality level. The DS was computed propagating the prediction error from the modeled responses to the quality criterion using Monte Carlo simulations. The optimal condition was predicted at a gradient slope of 3.8% min(-1) to linearly modify the modifier proportion between 5 and 40%, an isocratic time of 3min, a concentration of TFA of 25mM, and a temperature of 60.5°C. This optimal condition was experimentally tested to confirm the prediction. Furthermore, chromatographic conditions included in the DS and on the limits of the DS were experimentally tested to assess the robustness of the developed SFC method.
Journal of Pharmaceutical and Biomedical Analysis | 2014
Amandine Dispas; Pierre Lebrun; Bertyl Andri; Eric Rozet; Philippe Hubert
The concept of Quality by Design (QbD) is now well established in pharmaceutical industry and should be applied to the development of any analytical methods. In this context, the key concept of Design Space (DS) was introduced in the field of analytical method optimization. In chromatographic words, the DS is the space of chromatographic conditions that will ensure the quality of peaks separation, thus DS is a zone of robustness. In the present study, the interest of robust method optimization strategy was investigated in the context of direct method transfer from sending to receiving laboratory. The benefit of this approach is to speed up the method life cycle by performing only one quantitative validation step in the final environment of method use. A Supercritical Fluid Chromatography (SFC) method previously developed was used as a case study in this work. Moreover, the interest of geometric transfer was investigated simultaneously in order to stress a little bit more the transfer exercise and, by the way, emphasize the additional benefit of DS strategy in this particular context. Three successful transfers were performed on two column geometries. In order to compare original and transferred methods, the observed relative retention times (RT) were modelled as a function of the predicted relative RT and of the method type (original or transferred). The observed relative RT of the original and transferred methods are not statistically different and thus the method transfer is successfully achieved thanks to the robust optimization strategy. Furthermore, the analytical method was improved considering analysis time (reduced five times) and peak capacity (increased three times). To conclude, the advantage of using a DS strategy implemented for the optimization and transfer of SFC method was successfully demonstrated in this work.
Journal of Pharmaceutical and Biomedical Analysis | 2012
Frédéric Lecomte; Cédric Hubert; Sophie Demarche; C. De Bleye; Amandine Dispas; M. Jost; F. Frankenne; Attilio Ceccato; Eric Rozet; Ph. Hubert
Method validation is essential to ensure that an analytical method is fit for its intended purpose. Additionally, it is advisable to estimate measurement uncertainty in order to allow a correct interpretation of the results generated by analytical methods. Measurement uncertainty can be efficiently estimated during method validation as a top-down approach. However, method validation predictions of the quantitative performances of the assay and estimations of measurement uncertainty may be far away from the real performances obtained during the routine application of this assay. In this work, the predictions of the quantitative performances and measurement uncertainty estimations obtained from a method validation are compared to those obtained during routine applications of a bioanalytical method. For that purpose, a new hydrophilic interaction chromatography (HILIC) method was used. This method was developed for the determination of cidofovir, an antiviral drug, in human plasma. Cidofovir (CDV) is a highly polar molecule presenting three ionizable functions. Therefore, it is an interesting candidate for determination by HILIC mode. CDV is an acyclic cytidine monophosphate analog that has a broad antiviral spectrum and is currently undergoing evaluation in clinical trials as a topical agent for treatment of papillomavirus infections. The analytical conditions were optimized by means of design of experiments approach in order to obtain robust analytical conditions. These ones were absolutely necessary to enable the comparisons mentioned above. After a sample clean-up by means of solid phase extraction, the chromatographic analysis was performed on bare silica stationary phase using a mixture of acetonitrile-ammonium hydrogen carbonate (pH 7.0; 20mM) (72:28, v/v) as mobile phase. This newly developed bioanalytical method was then fully validated according to FDA (Food and Drug Administration) requirements using a total error approach that guaranteed that each future result will fall within acceptance limits of ±30% with a probability of 95% over a concentration range of 92.7-1020ng/mL. A routine application of the cidofovir determination in two pre-clinical trials demonstrated that the prediction made during the pre-study validation was consistent by retrospective analysis of the quality control (QC) samples. Finally, comparison of the measurement uncertainty estimations calculated from the method validation with those obtained from the routine application of the method was performed, stressing that the estimations obtained during method validation underestimated those obtained from routine applications and that the magnitude of this underestimation was function of the cidofovir concentration. Finally, this new HILIC method is reliable, easily applicable to routine analysis and transposable at low cost in other laboratories.
Journal of Pharmaceutical and Biomedical Analysis | 2016
Amandine Dispas; Pierre Lebrun; Pierre-Yves Sacre; Philippe Hubert
Nowadays, supercritical fluid chromatography is commonly presented as a promising alternative technique in the field of separation sciences. Nevertheless the selection of chromatographic conditions and sample preparation of pharmaceutical compounds remain a challenge and peak distortion was previously highlighted. The main objective of the present work was to evaluate the impact of different critical method parameters (CMPs), i.e. stationary phase, mobile phase composition and injection solvent nature. The experiments were performed considering two groups of antimalarial molecules: one group with neutral/apolar compounds and the other one with salt form of polar compounds. In this context, another objective was to propose a suitable sample solvent for quantitative analysis. The interest of new generation stationary phase to obtain good peak shape and the interest to tune the mobile phase composition were demonstrated. During this study, design of experiments and desirability function approach enabled to highlight optimal chromatographic conditions in order to maximise peak capacity and to get acceptable value of symmetry factor. Regarding sample injection solvent composition, some counterintuitive results were observed: solvents closer to the mobile phase polarity (i.e heptane or 2-propanol/heptane mixture) did not provide best results in terms of peak symmetry. In addition, acetonitrile and short aliphatic alcohols offered an interesting alternative as injection solvent: toxicity of solvents used is clearly reduced and better quantitative performances could be expected while keeping high peak capacity and symmetric sharp peaks. Finally, the quantitative performances were evaluated by the method validation for the quantitative determination of quinine sulfate in a pharmaceutical formulation. These better understandings on critical method parameters led SFC to be an even more promising technique in the field of the analysis of pharmaceutical compounds.
Journal of Chromatography A | 2017
Bertyl Andri; Pierre Lebrun; Amandine Dispas; Régis Klinkenberg; Bruno Streel; Eric Ziemons; R.D. Marini; Ph. Hubert
In the uprising context of green analytical chemistry, Supercritical Fluid Chromatography (SFC) is often suggested as an alternative to Normal Phase Liquid Chromatography. Indeed, SFC provides fast, efficient and green separations. In this report, the quantitative performances of SFC were challenged on a real-life case study: the Quality Control (QC) of vitamin D3. A rapid and green SFC method was optimized thanks to the Design of Experiments-Design Space (DoE-DS) methodology. It provided robust and high quality separation of the compounds within a 2min timeframe, using a gradient of ethanol as co-solvent of the carbon dioxide. The analytical method was fully validated according to the total error approach, demonstrating the compliance of the method to the specifications of U.S. Pharmacopeia (USP: 97.0-103.0%) and European Pharmacopeia (EP: 97.0-102.0%) for an interval of [50-150%] of the target concentration. In order to allow quantification of impurities using vitamin D3 as an external standard in SFC-UV, correction factors were determined and verified during method validation. Thus, accurate quantification of impurities was demonstrated at the specified levels (0.1 and 1.0% of the main compound) for a 70.0-130.0% dosing range. This work demonstrates the validity of an SFC method for the QC of vitamin D3 raw material and its application to real samples. Therefore, it supports the switch to a greener and faster separative technique as an alternative to NPLC in the pharmaceutical industry.
Journal of Pharmaceutical and Biomedical Analysis | 2017
Amandine Dispas; Vincent Desfontaine; Bertyl Andri; Pierre Lebrun; Dorina Kotoni; Adrian Clarke; Davy Guillarme; Philippe Hubert
HIGHLIGHTSSFC is an alternative to European Pharmacopeia method LC method for salbutamol sulfate impurities determination.Separation of salbutamol sulfate impurities was achieved in 7 min using SFC.Robust SFC method was optimized thanks to Design Space strategy.SFC method was successfully validated according to total error approach.SFC could be used for the quality control of salbutamol sulfate API. ABSTRACT In the last years, supercritical fluid chromatography has largely been acknowledged as a singular and performing technique in the field of separation sciences. Recent studies highlighted the interest of SFC for the quality control of pharmaceuticals, especially in the case of the determination of the active pharmaceutical ingredient (API). Nevertheless, quality control requires also the determination of impurities. The objectives of the present work were to (i) demonstrate the interest of SFC as a reference technique for the determination of impurities in salbutamol sulfate API and (ii) to propose an alternative to a reference HPLC method from the European Pharmacopeia (EP) involving ion‐pairing reagent. Firstly, a screening was carried out to select the most adequate and selective stationary phase. Secondly, in the context of robust optimization strategy, the method was developed using design space methodology. The separation of salbutamol sulfate and related impurities was achieved in 7 min, which is seven times faster than the LC‐UV method proposed by European Pharmacopeia (total run time of 50 min). Finally, full validation using accuracy profile approach was successfully achieved for the determination of impurities B, D, F and G in salbutamol sulfate raw material. The validated dosing range covered 50 to 150% of the targeted concentration (corresponding to 0.3% concentration level), LODs close to 0.5 &mgr;g/mL were estimated. The SFC method proposed in this study could be presented as a suitable fast alternative to EP LC method for the quantitative determination of salbutamol impurities.
Journal of Pharmaceutical and Biomedical Analysis | 2013
Jérémie Kindenge Mbinze; Amandine Dispas; Pierre Lebrun; J. Mavar Tayey Mbay; Védaste Habyalimana; N. Kalenda; Eric Rozet; Ph. Hubert; R.D. Marini
The poor quality of medicines is a crucial problem of public health. Therefore, it is important to have analytical tools to attend decisions of the legal authorities while combating this offense. In this context, the main objective of this study was to develop generic methods able to trace, screen and determine several antibiotics and common associated molecules by mean of liquid chromatographic techniques. For that purpose, an innovative Design Space optimization strategy was applied, targeting 16 antibiotics and 3 beta-lactamase inhibitors. The robustness of the developed method allowed using its use in an environment where operational factors such as temperature are not easy to control and eased its transfer to Ultra High Performance Liquid Chromatography. To demonstrate its ability to quantify the targeted molecules, the developed and transferred method was fully validated for two active ingredients commonly used in association, sulbactam and ceftriaxone, using the accuracy profile as decision tool. Based on this successful step, the method was then used for the quantitative determination of these two active ingredients in three pharmaceutical brands marketed in the Democratic Republic of Congo. Two out of the three pharmaceutical products did not comply with the specifications.
Bioanalysis | 2018
Amandine Dispas; Hugues Jambo; Sébastien André; Eva Tyteca; Philippe Hubert
During the last years, chemistry was involved in the worldwide effort toward environmental problems leading to the birth of green chemistry. In this context, green analytical tools were developed as modern Supercritical Fluid Chromatography in the field of separative techniques. This chromatographic technique knew resurgence a few years ago, thanks to its high efficiency, fastness and robustness of new generation equipment. These advantages and its easy hyphenation to MS fulfill the requirements of bioanalysis regarding separation capacity and high throughput. In the present paper, the technical aspects focused on bioanalysis specifications will be detailed followed by a critical review of bioanalytical supercritical fluid chromatography methods published in the literature.