Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Amir Manbachi is active.

Publication


Featured researches published by Amir Manbachi.


Advanced Materials | 2012

Microfabricated biomaterials for engineering 3D tissues.

Pinar Zorlutuna; Nasim Annabi; Gulden Camci-Unal; Mehdi Nikkhah; Jae Min Cha; Jason W. Nichol; Amir Manbachi; Hojae Bae; Shaochen Chen; Ali Khademhosseini

Mimicking natural tissue structure is crucial for engineered tissues with intended applications ranging from regenerative medicine to biorobotics. Native tissues are highly organized at the microscale, thus making these natural characteristics an integral part of creating effective biomimetic tissue structures. There exists a growing appreciation that the incorporation of similar highly organized microscale structures in tissue engineering may yield a remedy for problems ranging from vascularization to cell function control/determination. In this review, we highlight the recent progress in the field of microscale tissue engineering and discuss the use of various biomaterials for generating engineered tissue structures with microscale features. In particular, we will discuss the use of microscale approaches to engineer the architecture of scaffolds, generate artificial vasculature, and control cellular orientation and differentiation. In addition, the emergence of microfabricated tissue units and the modular assembly to emulate hierarchical tissues will be discussed.


Lab on a Chip | 2008

Microcirculation within grooved substrates regulates cell positioning and cell docking inside microfluidic channels

Amir Manbachi; Shamit Shrivastava; Margherita Cioffi; Bong Geun Chung; Matteo Moretti; Utkan Demirci; Marjo Yliperttula; Ali Khademhosseini

Immobilization of cells inside microfluidic devices is a promising approach for enabling studies related to drug screening and cell biology. Despite extensive studies in using grooved substrates for immobilizing cells inside channels, a systematic study of the effects of various parameters that influence cell docking and retention within grooved substrates has not been performed. We demonstrate using computational simulations that the fluid dynamic environment within microgrooves significantly varies with groove width, generating microcirculation areas in smaller microgrooves. Wall shear stress simulation predicted that shear stresses were in the opposite direction in smaller grooves (25 and 50 microm wide) in comparison to those in wider grooves (75 and 100 microm wide). To validate the simulations, cells were seeded within microfluidic devices, where microgrooves of different widths were aligned perpendicularly to the direction of the flow. Experimental results showed that, as predicted, the inversion of the local direction of shear stress within the smaller grooves resulted in alignment of cells on two opposite sides of the grooves under the same flow conditions. Also, the amplitude of shear stress within microgrooved channels significantly influenced cell retainment in the channels. Therefore, our studies suggest that microscale shear stresses greatly influence cellular docking, immobilization, and retention in fluidic systems and should be considered for the design of cell-based microdevices.


Ultrasound | 2011

Development and Application of Piezoelectric Materials for Ultrasound Generation and Detection

Amir Manbachi; Richard S. C. Cobbold

The piezoelectric effect and its converse are the primary means used in biomedical ultrasound for converting acoustical energy into electrical energy and vice versa. Piezoelectricity has found many bioengineering applications ranging from ultrasound imaging and therapeutics, to piezoelectric surgery and microelectromechanical systems, and to biomedical implants with associated energy harvesting. Because of its fundamental importance to the proper functioning of most medical ultrasound systems, it is important to gain a general understanding of the effect, the history of its development and from this, an appreciation of its limitations and advantages in the generation and detection of ultrasound. This article describes the historical evolvement associated with its use in relation to most medical ultrasound applications and is intended to serve as an introduction for non-expert readers.


The Spine Journal | 2014

Guided pedicle screw insertion: techniques and training

Amir Manbachi; Richard S. C. Cobbold; Howard J. Ginsberg

BACKGROUND CONTEXT In spinal fusion surgery, the accuracy with which screws are inserted in the pedicle has a direct effect on the surgical outcome. Accurate placement generally involves considerable judgmental skills that have been developed through a lengthy training process. Because the impact of misaligning one or more pedicle screws can directly affect patient safety, a number of navigational and trajectory verification approaches have been described and evaluated in the literature to provide some degree of guidance to the surgeon. PURPOSE To provide a concise review to justify the need and explore the current state of developing navigational or trajectory verification techniques for ensuring proper pedicle screw insertion along with simulation methods for better educating the surgical trainees. STUDY DESIGN Recent literature review. METHODS To justify the need to develop new methods for optimizing pedicle screw paths, we first reviewed some of the recent publications relating to the statistical outcomes for different types of navigation along with the conventional freehand (unassisted) screw insertion. Second, because of the importance of providing improved training in the skill of accurate screw insertion, the training aspects of relevant techniques are considered. The third part is devoted to the description of specific navigational assist methods or trajectory verification techniques and these include computer-assisted navigation, three-dimensional simulations, and also electric impedance and optical and ultrasonic image-guided methods. CONCLUSIONS This article presents an overview of the need and the current status of the guidance methods available for improving the surgical outcomes in spinal fusion procedures. It also describes educational aids that have the potential for reducing the training process.


Applied In Vitro Toxicology | 2016

Cardiovascular Organ-on-a-Chip Platforms for Drug Discovery and Development

João Ribas; Hossein Sadeghi; Amir Manbachi; Jeroen Leijten; Katelyn N. Brinegar; Yu Shrike Zhang; Lino Ferreira; Ali Khademhosseini

Cardiovascular diseases are prevalent worldwide and are the most frequent causes of death in the United States. Although spending in drug discovery/development has increased, the amount of drug approvals has seen a progressive decline. Particularly, adverse side effects to the heart and general vasculature have become common causes for preclinical project closures, and preclinical models do not fully recapitulate human in vivo dynamics. Recently, organs-on-a-chip technologies have been proposed to mimic the dynamic conditions of the cardiovascular system-in particular, heart and general vasculature. These systems pay particular attention to mimicking structural organization, shear stress, transmural pressure, mechanical stretching, and electrical stimulation. Heart- and vasculature-on-a-chip platforms have been successfully generated to study a variety of physiological phenomena, model diseases, and probe the effects of drugs. Here, we review and discuss recent breakthroughs in the development of cardiovascular organs-on-a-chip platforms, and their current and future applications in the area of drug discovery and development.


Journal of the Acoustical Society of America | 2012

Slow and fast ultrasonic wave detection improvement in human trabecular bones using Golay code modulation

Bahman Lashkari; Amir Manbachi; Andreas Mandelis; Richard S. C. Cobbold

The identification of fast and slow waves propagating through trabecular bone is a challenging task due to temporal wave overlap combined with the high attenuation of the fast wave in the presence of noise. However, it can provide valuable information about bone integrity and become a means for monitoring osteoporosis. The objective of this work is to apply different coded excitation methods for this purpose. The results for single-sine cycle pulse, Golay code, and chirp excitations are compared. It is shown that Golay code is superior to the other techniques due to its signal enhancement while exhibiting excellent resolution without the ambiguity of sidelobes.


Physiological Measurement | 2011

On the shape of the common carotid artery with implications for blood velocity profiles

Amir Manbachi; Yiemeng Hoi; Bruce A. Wasserman; Edward G. Lakatta; David A. Steinman

Clinical and engineering studies typically assume that the common carotid artery (CCA) is straight enough to assume fully developed flow, yet recent studies have demonstrated the presence of skewed velocity profiles. Toward elucidating the influence of mild vascular curvatures on blood flow patterns and atherosclerosis, this study aimed to characterize the three-dimensional shape of the human CCA. The left and right carotid arteries of 28 participants (63 ± 12 years) in the VALIDATE (Vascular Aging--The Link that Bridges Age to Atherosclerosis) study were digitally segmented from 3D contrast-enhanced magnetic resonance angiograms, from the aortic arch to the carotid bifurcation. Each CCA was divided into nominal cervical and thoracic segments, for which curvatures were estimated by least-squares fitting of the respective centerlines to planar arcs. The cervical CCA had a mean radius of curvature of 127 mm, corresponding to a mean lumen:curvature radius ratio of 1:50. The thoracic CCA was significantly more curved at 1:16, with the plane of curvature tilted by a mean angle of 25° and rotated close to 90° with respect to that of the cervical CCA. The left CCA was significantly longer and slightly more curved than the right CCA, and there was a weak but significant increase in CCA curvature with age. Computational fluid dynamic simulations carried out for idealized CCA geometries derived from these and other measured geometric parameters demonstrated that mild cervical curvature is sufficient to prevent flow from fully-developing to axisymmetry, independent of the degree of thoracic curvature. These findings reinforce the idea that fully developed flow may be the exception rather than the rule for the CCA, and perhaps other nominally long and straight vessels.


Biofabrication | 2017

Surface acoustic waves induced micropatterning of cells in gelatin methacryloyl (GelMA) hydrogels.

Shahid M Naseer; Amir Manbachi; Mohamadmahdi Samandari; Philipp Walch; Yuan Gao; Yu Shrike Zhang; Farideh Davoudi; Wesley Wang; Karen Abrinia; Jonathan M. Cooper; Ali Khademhosseini; Su Ryon Shin

Acoustic force patterning is an emerging technology that provides a platform to control the spatial location of cells in a rapid, accurate, yet contactless manner. However, very few studies have been reported on the usage of acoustic force patterning for the rapid arrangement of biological objects, such as cells, in a three-dimensional (3D) environment. In this study, we report on a bio-acoustic force patterning technique, which uses surface acoustic waves (SAWs) for the rapid arrangement of cells within an extracellular matrix-based hydrogel such as gelatin methacryloyl (GelMA). A proof-of-principle was achieved through both simulations and experiments based on the in-house fabricated piezoelectric SAW transducers, which enabled us to explore the effects of various parameters on the performance of the built construct. The SAWs were applied in a fashion that generated standing SAWs (SSAWs) on the substrate, the energy of which subsequently was transferred into the gel, creating a rapid, and contactless alignment of the cells (<10 s, based on the experimental conditions). Following ultraviolet radiation induced photo-crosslinking of the cell encapsulated GelMA pre-polymer solution, the patterned cardiac cells readily spread after alignment in the GelMA hydrogel and demonstrated beating activity in 5-7 days. The described acoustic force assembly method can be utilized not only to control the spatial distribution of the cells inside a 3D construct, but can also preserve the viability and functionality of the patterned cells (e.g. beating rates of cardiac cells). This platform can be potentially employed in a diverse range of applications, whether it is for tissue engineering, in vitro cell studies, or creating 3D biomimetic tissue structures.


Physiological Measurement | 2014

On estimating the directionality distribution in pedicle trabecular bone from micro-CT images.

Catherine M. Gdyczynski; Amir Manbachi; Sayed Masoud Hashemi; Bahman Lashkari; Richard S. C. Cobbold

Our interest in the trabecular alignment within bone stems from the need to better understand the manner in which it can affect ultrasound propagation, particularly in pedicles. Within long bones it is well established that trabecular structures are aligned in an organized manner associated with the direction of load distribution; however, for smaller bones there are limited alignment studies. To investigate the directionality distribution in a quantitative manner we used a micro-CT to obtain three-dimensional (3D) structural data and developed analytical methods based on the special properties of Gabor filters. Implementation of these techniques has been developed and tested on a variety of simulated images as well as on 3D structures whose geometry is well-defined. To test the use of this technique we compared the results obtained on vertebral body trabecular bone with visual directionality and previous measurements by others. The method has been applied to six human pedicle samples in two orthogonal planes with results that provide reasonable proof-of-principle evidence that the method is well suited for estimating the directionality distribution within pedicle bones.


Advanced Materials | 2018

Microfluidics-Enabled Multimaterial Maskless Stereolithographic Bioprinting.

Amir K. Miri; Daniel Nieto; Luis Iglesias; Hossein Goodarzi Hosseinabadi; Sushila Maharjan; Guillermo U. Ruiz-Esparza; Parastoo Khoshakhlagh; Amir Manbachi; Mehmet R. Dokmeci; Shaochen Chen; Su Ryon Shin; Yu Shrike Zhang; Ali Khademhosseini

A stereolithography-based bioprinting platform for multimaterial fabrication of heterogeneous hydrogel constructs is presented. Dynamic patterning by a digital micromirror device, synchronized by a moving stage and a microfluidic device containing four on/off pneumatic valves, is used to create 3D constructs. The novel microfluidic device is capable of fast switching between different (cell-loaded) hydrogel bioinks, to achieve layer-by-layer multimaterial bioprinting. Compared to conventional stereolithography-based bioprinters, the system provides the unique advantage of multimaterial fabrication capability at high spatial resolution. To demonstrate the multimaterial capacity of this system, a variety of hydrogel constructs are generated, including those based on poly(ethylene glycol) diacrylate (PEGDA) and gelatin methacryloyl (GelMA). The biocompatibility of this system is validated by introducing cell-laden GelMA into the microfluidic device and fabricating cellularized constructs. A pattern of a PEGDA frame and three different concentrations of GelMA, loaded with vascular endothelial growth factor, are further assessed for its neovascularization potential in a rat model. The proposed system provides a robust platform for bioprinting of high-fidelity multimaterial microstructures on demand for applications in tissue engineering, regenerative medicine, and biosensing, which are otherwise not readily achievable at high speed with conventional stereolithographic biofabrication platforms.

Collaboration


Dive into the Amir Manbachi's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Ali Uneri

Johns Hopkins University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

J. Goerres

Johns Hopkins University

View shared research outputs
Top Co-Authors

Avatar

M. D. Ketcha

Johns Hopkins University

View shared research outputs
Top Co-Authors

Avatar

M. Jacobson

Johns Hopkins University

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge