Andrea Siani
Sapienza University of Rome
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Andrea Siani.
Journal of Vascular Surgery | 2012
Roberto Gabrielli; Maria Sofia Rosati; Silvio Vitale; Giulia Baciarello; Andrea Siani; Roberto Chiappa; Giovanni Caselli; Luigi Irace
OBJECTIVE This study evaluated outcomes of remote endarterectomy (RE) vs endovascular (ENDO) interventions on TransAtlantic Inter-Societal Consensus (TASC)-II D femoropopliteal lesions and identified factors predictive of restenosis. METHODS From October 2004 to December 2008, 95 patients with TASC-II D lesions were randomized 1:1 to receive RE of the superficial femoral artery (SFA) with end point stenting (51 patients) or ENDO, consisting of subintimal angioplasty with stenting (44 patients). The groups were balanced for age, sex, atherosclerotic risk factors, and comorbidities. Categoric data were analyzed with χ2 tests, and time to event provided two-sided P values with a level of significance at .05 and 95% confidence intervals (CIs). Survival curves for primary patency were plotted using the Kaplan-Meier method. Univariate analysis for diabetes, hypertension, dyslipidemia, smoking, and critical ischemia was performed according to the Cox proportional hazards model. RESULTS The mean follow-up was 52.5 months (range, 35-75 months). Five RE patients and four ENDO patients were lost to follow-up (censored). Primary patency was 76.5% (39 of 51) in RE and 56.8% (25 of 44) in ENDO (hazard ratio [HR], 2.6; 95% CI, 0.99-4.2; P=.05) at 24 months and was 62.7% (32 of 46) in RE and 47.7% (21 of 40) in ENDO (HR, 1.89; 95% CI, 0.94-3.78; P=.07) at 36 months. Assisted primary patency was 70.6% (36 of 51) in RE and 52.3% (23 of 44) in ENDO (HR, 2.45; 95% CI, 1.20-5.02; P=.01). Secondary patency overlapped the primary comparison data at 12 and 24 months; at 36 months, there was a slight but significative advantage for RE (HR, 2.26; 95% CI, 1.05-4.86; P=.03). Univariate analysis demonstrated that hypercholesterolemia and critical limb ischemia (CLI) were significantly related to patency failure, whereas diabetes was significant only in ENDO. These factors (hypercholesterolemia and CLI) were independent predictors of patency on Cox multivariate analysis. CONCLUSIONS RE is a safe, effective, and durable procedure for TASC-II D lesions. Our data demonstrate a significantly higher primary, assisted primary, and secondary patency of RE vs ENDO procedures. Furthermore, overall secondary patency rates remain within the standard limits, although preoperative CLI and dyslipidemia continue to be associated with worse outcomes. Taken together, these data suggest that RE should be considered better than an endovascular procedure in SFA long-segment occlusion treatment.
Interactive Cardiovascular and Thoracic Surgery | 2011
Giustino Marcucci; Andrea Siani; Federico Accrocca; Roberto Gabrielli; Alessandro Giordano; Roberto Antonelli; Andrea Sbroscia; Federica Mounayergi
OBJECTIVES We prospectively evaluated safety and efficacy from our six-year results of general anesthesia (GA) using remifentanil conscious sedation in carotid endarterectomy (CEA). METHODS From January 2005 to December 2010, 625 consecutive CEAs were performed on 545 patients (male/female 336/209, age 75 ± 7 years). After a superficial plexus block with ropavacaine, GA was induced with an intravenous infusion of propofol, using local lidocaine during tracheal intubation and a high-dose of remifentanil, in all cases reducing and then stopping the remifentanil infusion at the clamping time so that the patient would be awake and collaborating within a few minutes, as in local anesthesia. Data on postoperative morbidity and mortality, neurological complications, shunt insertions and the responses to one-day and three-month questionnaires on satisfaction were collected for all patients. RESULTS The 30-day mortality was 0.32% (two patients). Only one major stroke (0.16%) and two minor strokes (0.32%) occurred. A shunt was deployed in 83 cases (13.3%). Eight patients (1.28%) reported cranial nerve injuries, and surgical drainage for postoperative hematoma was performed in 11 patients (1.8%). Thirty-one patients (4.6%) suffered postoperative nausea/vomiting. Almost all patients were satisfied at the 24-h (94.6%) and three-month (>98%) follow-up questionnaire. CONCLUSIONS The six-year results for GA using remifentanil conscious sedation were very satisfactory and highlighted the advantages of both GA (hemodynamic stability and excellent control of ventilation) and local anesthesia (ease of evaluation of neurological status) in a calm and relaxed environment for both patient and surgeon.
Interactive Cardiovascular and Thoracic Surgery | 2011
Andrea Siani; Federico Accrocca; Roberto Gabrielli; Roberto Antonelli; Alessandro Giordano; Cesare Ambrogi; Giustino Marcucci
Arterial percutaneous closure devices (APCD) could lead to severe vascular complications, like acute lower limb ischemia. The aim of this study was to evaluate retrospectively our personal series of acute lower limb ischemia following the use of APCD. From January 2004 to June 2009 the Angio-Seal percutaneous closure devices was deployed in 198 patients. Eight (4%) acute lower limb ischemia required urgent surgical repair. The device was removed in all cases. A thromboembolectomy was performed in five patients (62.5%) and in three (37.5%) an endarterectomy with patch closure was carried out (two saphenous vein and one Dacron). Limb salvage rate was 87.5%. We compared Angio-Seal complications group (A) with the 190 patients in which the Angio-Seal was successfully used without complications (group B) by means of Students t-test. At 36-month follow-up with color-coded duplex ultrasounds, no chronic limb ischemia or other complications requiring surgical repair occurred. Diabetes, obesity, severe femoral atherosclerotic involvement, use of sheath size >7 Fr and time-consuming procedures were significant risk factors for ischemic APCD complications. Despite vascular injuries being uncommon after APCD deployment, generally a complex surgical repair is necessary. A more careful patient selection would be advisable.
Interactive Cardiovascular and Thoracic Surgery | 2013
Andrea Siani; Federico Accrocca; Roberto Gabrielli; Giustino Marcucci
The chimney graft (CG) technique, based on the deployment of a covered stent parallel to the aortic endograft, has been proposed to achieve a safe proximal fixation extending the sealing zone. We report our experience with the CG technique in an emergency setting. Between December 2010 and April 2012, 4 patients underwent the CG technique. The mean age was 79 (range 76-82 years) and 3 patients were men. The median aneurysm diameter was 64.7 mm (range 63-68 mm). Indications for CG were painful proximal para-anastomotic aneurysm in 2 cases and symptomatic juxtarenal aneurysm in the other 2. Target vessels were both the renal arteries. Technical success was achieved in 100% and no intraoperative complications occurred. No stent-related complications, or Type I endoleak, were detected. No death occurred during the postoperative course. Creatinine elevation was observed in 2 cases. At follow-up, no endoleaks or rupture occurred. One patient died of myocardial infarction 3 months after the procedure. The primary patency rate of covered stents was 100%. The CG technique seems to be safe and feasible with an excellent patency rate of covered stents and a low incidence of endoleaks. More evidence in the literature is needed to carry out a validation of this technique in an emergency.
Interactive Cardiovascular and Thoracic Surgery | 2008
Andrea Siani; Luca Maria Siani; Federica Mounayergi
A coronary stent may be lost in the peripheral or visceral arterial system with an incidence ranging from 0.9 to 8.4%, however, a limb or organ ischemia after stent migration is very uncommon. We report the case of an 83-year-old man who underwent coronary artery stenting at our Hospitals Cardiological Department. During this difficult procedure, due to the critical stenosis of the circumflex artery, the stent was accidentally lost and found at the level of the insertion of the right common femoral on the external iliac artery. After several attempts to rescue the stent through an omolateral and contralateral femoral approach with the hook technique, the right common, superficial and profunda femoral arteries were surgically exposed. The stent was easily removed from the origin of the profunda femoral artery by a longitudinal arteriotomy. Finally, the arteriotomy was closed with a homologous saphenous vein patch. We underline the importance of an early extraction of the stent, discussing the preferable surgical approach to minimize the possible dramatic complications in the peripheral artery system.
Interactive Cardiovascular and Thoracic Surgery | 2010
Giustino Marcucci; Federico Accrocca; Pier Luigi Antignani; Andrea Siani
We report the first case of isolated aneurysm of the anterolateral branch of the greater saphenous vein in a 24-year-old man. The aneurysm was initially confused with an inguinal hernia. The patient referred with a respiratory distress due to a pulmonary embolism. The Doppler ultrasounds permitted to clarify the diagnosis. The aneurysm was removed en block under local anaesthesia. Surgeons should be aware to consider a venous aneurysm in the differential diagnosis of an inguinal mass. Indeed, due to its potential risk or embolism, the surgical treatment is mandatory.
Annals of Vascular Surgery | 2012
Andrea Siani; Giustino Marcucci; Federico Accrocca; Roberto Antonelli; Federica Mounayergi; Maria Sofia Rosati; Roberto Gabrielli
Venous hypertension and outflow stenosis of arteriovenous hemodialysis access managed using endovascular procedures usually present a high technical success rate, with few complications. We reported a rare and fatal complication of superior vena cava perforation with pericardial tamponade 3 months after subclavian vein stenting. Interventional recanalization with stenting for the management of superior vena cava syndrome or central vein stenosis is a safe procedure with a low complication rate. Stent misplacement, reocclusion, migration, or access-related complications appear to occur most frequently.
Annals of Vascular Surgery | 2011
Roberto Gabrielli; Andrea Siani; Maria Sofia Rosati; Roberto Antonelli; Federico Accrocca; Gioacchino Alessandro Giordano; Giustino Marcucci
Heparin-induced thrombocytopenia type II is an immune-mediated syndrome that may arise in a time-dependent manner after heparin therapy. Thrombocytopenia and thrombosis in patients exposed to heparin are suggestive of this syndrome.
Journal of Vascular Surgery | 2010
Roberto Gabrielli; Maria Sofia Rosati; Alessandro Costanzo; Roberto Chiappa; Andrea Siani; Giovanni Caselli
We report the case of a 42-year-old man with pleuritic chest pain, shortness of breath, and associated tachycardia. Three months before, he had been treated for similar features with the diagnosis of pulmonary emboli. Computed tomography scan showed multiple bilateral pulmonary emboli. He had no clinical evidence of deep venous thrombosis, but an accurate venous duplex examination revealed a thrombosis of the posterior tibial vein aneurysm. Thrombolysis, a temporary inferior cava filter (ICV filter), and tangential aneurysmectomy and lateral venorrhaphy were performed. Accurate duplex scan evaluation of lower limb venous system is mandatory in all cases of pulmonary embolism; anticoagulation may be ineffective in preventing pulmonary embolism, and the surgical repair is treatment of choice of this pathology because it is safe and effective.
Interactive Cardiovascular and Thoracic Surgery | 2008
Giustino Marcucci; Federico Accrocca; Roberto Antonelli; Andrea Siani
OBJECTIVES Arterial injury of the lower limb is a rare but catastrophic complication of saphenous vein stripping with a high morbidity rate and severe medico-legal implications. Diagnosis is often delayed and outcome depends on the severity of injury. We report two cases of severe ischemia due to arterial lesion during varicose veins surgery. METHODS In the first case, a superficial femoral artery ligature after an operation for recurrent varicose veins surgery occurred; in the second case, an intraoperative ligature of the superficial femoral artery and vein was detected. In the first case, an angiography was carried out and a superficial-superficial femoral artery interposition graft with PTFE was performed. In the other case, an interposition graft with a contralateral saphenous vein between the common and superficial femoral artery and an end-to-end anastomosis of the superficial femoral vein was carried out. RESULTS No amputation occurred, good patency rate of the graft was achieved and no neurologic-muscle complications were revealed. CONCLUSIONS Femoral artery injury after venous stripping shows a high amputation rate due to delayed diagnosis and severity of arterial involvement. Angiography must be reserved in any case of late ischemia. Prompt diagnosis and aggressive management is mandatory.