Publication


Featured researches published by Andreas Haeberlin.


Europace | 2014

Successful pacing using a batteryless sunlight-powered pacemaker

Andreas Haeberlin; Adrian Zurbuchen; Jakob Schaerer; Joerg Wagner; Sébastien Walpen; Christoph Huber; Heinrich Haeberlin; Juerg Fuhrer; Rolf Vogel

AIMS Todays cardiac pacemakers are powered by batteries with limited energy capacity. As the batterys lifetime ends, the pacemaker needs to be replaced. This surgical re-intervention is costly and bears the risk of complications. Thus, a pacemaker without primary batteries is desirable. The goal of this study was to test whether transcutaneous solar light could power a pacemaker. METHODS AND RESULTS We used a three-step approach to investigate the feasibility of sunlight-powered cardiac pacing. First, the harvestable power was estimated. Theoretically, a subcutaneously implanted 1 cm(2) solar module may harvest ∼2500 µW from sunlight (3 mm implantation depth). Secondly, ex vivo measurements were performed with solar cells placed under pig skin flaps exposed to a solar simulator and real sunlight. Ex vivo measurements under real sunlight resulted in a median output power of 4941 µW/cm(2) [interquartile range (IQR) 3767-5598 µW/cm(2), median skin flap thickness 3.0 mm (IQR 2.7-3.3 mm)]. The output power strongly depended on implantation depth (ρSpearman = -0.86, P < 0.001). Finally, a batteryless single-chamber pacemaker powered by a 3.24 cm(2) solar module was implanted in vivo in a pig to measure output power and to pace. In vivo measurements showed a median output power of >3500 µW/cm(2) (skin flap thickness 2.8-3.84 mm). Successful batteryless VVI pacing using a subcutaneously implanted solar module was performed. CONCLUSION Based on our results, we estimate that a few minutes of direct sunlight (irradiating an implanted solar module) allow powering a pacemaker for 24 h using a suitable energy storage. Thus, powering a pacemaker by sunlight is feasible and may be an alternative energy supply for tomorrows pacemakers.


Heart Rhythm | 2016

Failure rate and conductor externalization in the Biotronik Linox/Sorin Vigila implantable cardioverter-defibrillator lead

Fabian Noti; Anna Lam; Nicole Klossner; Jens Seiler; Helge Servatius; Argelia Medeiros-Domingo; Vân Nam Tran; Andreas Haeberlin; Juerg Fuhrer; Hildegard Tanner; Laurent Roten

BACKGROUND We observed a case of conductor externalization in a Biotronik Linox lead. OBJECTIVE The purpose of this study was to investigate lead performance of the Linox lead and the identical Sorin Vigila lead and prevalence of conductor externalization. METHODS We compared lead performance of all Linox and Vigila leads implanted at our center (BL group; n = 93) with that of all Boston Scientific Endotak Reliance leads (ER group; n = 190) and Medtronic Sprint Quattro leads (SQ group; n = 202) implanted during the same period. We screened all patients in the BL group for conductor externalization. RESULTS We identified 8 cases of lead failures in the BL group (index case of conductor externalization, 6 cases of nonphysiological high-rate sensing, and 1 case of high-voltage conductor fracture). Prospective fluoroscopic screening of 98% of all active BL group cases revealed 1 additional case of conductor externalization. The median follow-up was 41, 27, and 29 months for the BL group, ER group, and SQ group, respectively; lead survival was 94.9%, 99.2%, and 100% at 3 years and 88%, 97.5%, and 100% at 5 years (P = .038 for BL group vs ER group and P = .007 for BL group vs SQ group using the log-rank test). Younger age at implant was an independent predictor of lead failure in the BL group (adjusted hazard ratio 0.85; 95% confidence interval 0.77-0.94; P = .001). CONCLUSION At our center, survival of the Linox lead is 88% at 5 years and significantly worse than that of other leads. Conductor externalization is present in a minority of failed Linox leads. Younger age at implant is an independent predictor of Linox lead failure.


Heart Rhythm | 2014

Software-based detection of atrial fibrillation in long-term ECGs.

Andreas Haeberlin; Laurent Roten; Manuel Schilling; Flavio Scarcia; Thomas Niederhauser; Rolf Vogel; Juerg Fuhrer; Hildegard Tanner

BACKGROUND Atrial fibrillation (AF) is common and may have severe consequences. Continuous long-term electrocardiogram (ECG) is widely used for AF screening. Recently, commercial ECG analysis software was launched, which automatically detects AF in long-term ECGs. It has been claimed that such tools offer reliable AF screening and save time for ECG analysis. However, this has not been investigated in a real-life patient cohort. OBJECTIVE To investigate the performance of automatic software-based screening for AF in long-term ECGs. METHODS Two independent physicians manually screened 22,601 hours of continuous long-term ECGs from 150 patients for AF. Presence, number, and duration of AF episodes were registered. Subsequently, the recordings were screened for AF by an established ECG analysis software (Pathfinder SL), and its performance was validated against the thorough manual analysis (gold standard). RESULTS Sensitivity and specificity for AF detection was 98.5% (95% confidence interval 91.72%-99.96%) and 80.21% (95% confidence interval 70.83%-87.64%), respectively. Software-based AF detection was inferior to manual analysis by physicians (P < .0001). Median AF duration was underestimated (19.4 hours vs 22.1 hours; P < .001) and median number of AF episodes was overestimated (32 episodes vs 2 episodes; P < .001) by the software. In comparison to extensive quantitative manual ECG analysis, software-based analysis saved time (2 minutes vs 19 minutes; P < .001). CONCLUSION Owing to its high sensitivity and ability to save time, software-based ECG analysis may be used as a screening tool for AF. An additional manual confirmatory analysis may be required to reduce the number of false-positive findings.


Journal of Electrocardiology | 2013

The optimal lead insertion depth for esophageal ECG recordings with respect to atrial signal quality

Andreas Haeberlin; Thomas Niederhauser; Thanks Marisa; Josef Goette; Marcel Jacoment; Daniel Mattle; Laurent Roten; Juerg Fuhrer; Hildegard Tanner; Rolf Vogel

BACKGROUND Diagnosing supraventricular arrhythmias by conventional long-term ECG can be cumbersome because of poor p-waves. Esophageal long-term electrocardiography (eECG) has an excellent sensitivity for atrial signals and may overcome this limitation. However, the optimal lead insertion depth (OLID) is not known. METHODS We registered eECGs at different lead insertion depths in 27 patients and analyzed 199,716 atrial complexes with respect to signal amplitude and slope. Correlation and regression analyses were used to find a criterion for OLID. RESULTS Atrial signal amplitudes and slopes significantly depend on lead insertion depth. OLID correlates with body height (rSpearman=0.71) and can be estimated by OLID [cm]=0.25*body height[cm]-7cm. At this insertion depth, we recorded the largest esophageal atrial signal amplitudes (1.27±0.86mV), which were much larger compared to conventional surface lead II (0.19±0.10mV, p<0.0001). CONCLUSION The OLID depends on body height and can be calculated by a simple regression formula.


Medical & Biological Engineering & Computing | 2012

High-resolution esophageal long-term ECG allows detailed atrial wave morphology analysis in case of atrial ectopic beats

Thomas Niederhauser; Thanks Marisa; Andreas Haeberlin; Josef Goette; Marcel Jacoment; Rolf Vogel

Detection of arrhythmic atrial beats in surface ECGs can be challenging when they are masked by the R or T wave, or do not affect the RR-interval. Here, we present a solution using a high-resolution esophageal long-term ECG that offers a detailed view on the atrial electrical activity. The recorded ECG shows atrial ectopic beats with long coupling intervals, which can only be successfully classified using additional morphology criteria. Esophageal high-resolution ECGs provide this information, whereas surface long-term ECGs show poor atrial signal quality. This new method is a promising tool for the long-term rhythm monitoring with software-based automatic classification of atrial beats.


Circulation | 2012

Esophageal Long-Term ECG Reveals Paroxysmal Atrial Fibrillation

Andreas Haeberlin; Thomas Niederhauser; Thanks Marisa; Daniel Mattle; Marcel Jacomet; Josef Goette; Hildegard Tanner; Rolf Vogel

A 79-year-old man was referred for coronary angiography because of atypical chest pain. The patients medical history included a myocardial infarction 5 years previously and well-controlled arterial hypertension. Three months before this admission he reported atypical chest pain, sometimes associated with palpitations lasting seconds up to a few minutes. Hence, he underwent ambulant 24-hour ECG, which revealed frequent atrial premature beats but no other arrhythmia. On admission, the patient was in sinus rhythm. Echocardiography showed normal ventricular function without structural heart disease. After successful percutaneous transluminal coronary angioplasty, the patient was included in a study …


IEEE Transactions on Biomedical Engineering | 2013

Electrodes for Long-Term Esophageal Electrocardiography

Thomas Niederhauser; Andreas Haeberlin; Thanks Marisa; Michael Jungo; Josef Goette; Marcel Jacomet; Roger Abächerli; Rolf Vogel

The emerging application of long-term and high-quality ECG recording requires alternative electrodes to improve the signal quality and recording capability of surface skin electrodes. The esophageal ECG has the potential to overcome these limitations but necessitates novel recorder and lead designs. The electrode material is of particular interest, since the material has to ensure conflicting requirements like excellent biopotential recording properties and inertness. To this end, novel electrode materials like PEDOT and silver-PDMS as well as established electrode materials such as stainless steel, platinum, gold, iridium oxide, titanium nitride, and glassy carbon were investigated by long-term electrochemical impedance spectroscopy and model-based signal analysis using the derived in vitro interfacial properties in conjunction with a dedicated ECG amplifier. The results of this novel approach show that titanium nitride and iridium oxide featuring microstructured surfaces did not degrade when exposed to artificial acidic saliva. These materials provide low electrode potential drifts and insignificant signal distortion superior to surface skin electrodes making them compatible with accepted standards for ambulatory ECG. They are superior to the noble and polarizable metals such as platinum, silver, and gold that induced more signal distortions and are superior to esophageal stainless steel electrodes that corrode in artificial saliva. The study provides rigorous criteria for the selection of electrode materials for prolonged ECG recording by combining long-term in vitro electrode material properties with ECG signal quality assessment.


IEEE Transactions on Biomedical Engineering | 2015

Graphics Processor Unit Based Parallelization of Optimized Baseline Wander Filtering Algorithms for Long-term Electrocardiography

Thomas Niederhauser; Thomas Wyss-Balmer; Andreas Haeberlin; Thanks Marisa; Reto A. Wildhaber; Josef Goette; Marcel Jacomet; Rolf Vogel

Long-term electrocardiogram (ECG) often suffers from relevant noise. Baseline wander in particular is pronounced in ECG recordings using dry or esophageal electrodes, which are dedicated for prolonged registration. While analog high-pass filters introduce phase distortions, reliable offline filtering of the baseline wander implies a computational burden that has to be put in relation to the increase in signal-to-baseline ratio (SBR). Here, we present a graphics processor unit (GPU)-based parallelization method to speed up offline baseline wander filter algorithms, namely the wavelet, finite, and infinite impulse response, moving mean, and moving median filter. Individual filter parameters were optimized with respect to the SBR increase based on ECGs from the Physionet database superimposed to autoregressive modeled, real baseline wander. A Monte-Carlo simulation showed that for low input SBR the moving median filter outperforms any other method but negatively affects ECG wave detection. In contrast, the infinite impulse response filter is preferred in case of high input SBR. However, the parallelized wavelet filter is processed 500 and four times faster than these two algorithms on the GPU, respectively, and offers superior baseline wander suppression in low SBR situations. Using a signal segment of 64 mega samples that is filtered as entire unit, wavelet filtering of a seven-day high-resolution ECG is computed within less than 3 s. Taking the high filtering speed into account, the GPU wavelet filter is the most efficient method to remove baseline wander present in long-term ECGs, with which computational burden can be strongly reduced.


IEEE Transactions on Biomedical Circuits and Systems | 2016

A Baseline Wander Tracking System for Artifact Rejection in Long-Term Electrocardiography

Thomas Niederhauser; Thanks Marisa; Lukas Kohler; Andreas Haeberlin; Reto A. Wildhaber; Roger Abächerli; Josef Goette; Marcel Jacomet; Rolf Vogel

Long-term electrocardiogram (ECG) signals might suffer from relevant baseline disturbances during physical activity. Motion artifacts in particular are more pronounced with dry surface or esophageal electrodes which are dedicated to prolonged ECG recording. In this paper we present a method called baseline wander tracking (BWT) that tracks and rejects strong baseline disturbances and avoids concurrent saturation of the analog front-end. The proposed algorithm shifts the baseline level of the ECG signal to the middle of the dynamic input range. Due to the fast offset shifts, that produce much steeper signal portions than the normal ECG waves, the true ECG signal can be reconstructed offline and filtered using computationally intensive algorithms. Based on Monte Carlo simulations we observed reconstruction errors mainly caused by the non-linearity inaccuracies of the DAC. However, the signal to error ratio of the BWT is higher compared to an analog front-end featuring a dynamic input ranges above 15 mV if a synthetic ECG signal was used. The BWT is additionally able to suppress (electrode) offset potentials without introducing long transients. Due to its structural simplicity, memory efficiency and the DC coupling capability, the BWT is dedicated to high integration required in long-term and low-power ECG recording systems.


IEEE Transactions on Biomedical Engineering | 2015

Bufferless Compression of Asynchronously Sampled ECG Signals in Cubic Hermitian Vector Space

Thanks Marisa; Thomas Niederhauser; Andreas Haeberlin; Reto A. Wildhaber; Rolf Vogel; Marcel Jacomet; Josef Goette

Asynchronous level crossing sampling analog-to-digital converters (ADCs) are known to be more energy efficient and produce fewer samples than their equidistantly sampling counterparts. However, as the required threshold voltage is lowered, the number of samples and, in turn, the data rate and the energy consumed by the overall system increases. In this paper, we present a cubic Hermitian vector-based technique for online compression of asynchronously sampled electrocardiogram signals. The proposed method is computationally efficient data compression. The algorithm has complexity O(n), thus well suited for asynchronous ADCs. Our algorithm requires no data buffering, maintaining the energy advantage of asynchronous ADCs. The proposed method of compression has a compression ratio of up to 90% with achievable percentage root-mean-square difference ratios as a low as 0.97. The algorithm preserves the superior feature-to-feature timing accuracy of asynchronously sampled signals. These advantages are achieved in a computationally efficient manner since algorithm boundary parameters for the signals are extracted a priori.

Collaboration


Dive into the Andreas Haeberlin's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Thomas Niederhauser

Bern University of Applied Sciences

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Josef Goette

Bern University of Applied Sciences

View shared research outputs
Top Co-Authors

Avatar

Marcel Jacomet

Bern University of Applied Sciences

View shared research outputs
Top Co-Authors

Avatar

Thanks Marisa

Bern University of Applied Sciences

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge