Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Andreas Rechner is active.

Publication


Featured researches published by Andreas Rechner.


Platelets | 2011

The new INNOVANCE® PFA P2Y cartridge is sensitive to the detection of the P2Y12 receptor inhibition

Juergen Koessler; Anna L. Kobsar; Mirjana S. Rajkovic; A. Schäfer; Ulrike Flierl; Stephanie Pfoertsch; Johann Bauersachs; Udo Steigerwald; Andreas Rechner; Ulrich Walter

Insufficient response on antiplatelet medication has become an intensively discussed issue because of the risk factor of recurrent adverse cardiovascular events. However, the monitoring of antiplatelet therapy requires appropriate, robust and reliable test methods. For the measurement of thienopyridine effects, the manufacturer of the PFA-100® System provides the INNOVANCE® PFA P2Y cartridge. We tested this cartridge for its capacity to detect the inhibition of the P2Y12 receptor, which is the target for thienopyridine medication (e.g. clopidogrel). We compared the INNOVANCE® PFA P2Y results with those obtained by the receptor specific flow cytometric vasodilator stimulated phosphoprotein (VASP) assay that expresses the status of the P2Y12 receptor as “platelet reactivity index” (PRI). The in vitro addition of the P2Y12 receptor antagonist cangrelor (AR-C69931MX) to citrated human whole blood resulted in a dose-dependent prolongation of closure times (CTs) of the INNOVANCE® PFA P2Y cartridge correlating with decreased PRI levels. In volunteers, the intake of a 600 mg clopidogrel loading dose caused an increase of the CTs in all volunteers, although some of these volunteers were identified as “poor responders” by the VASP assay (no significant reduction of PRI levels). In 50 patients with stable coronary artery disease undergoing percutaneous coronary intervention (PCI) and under dual antiplatelet therapy, the new cartridge had a detection rate of 84% (CT 106 s as cut-off) for clopidogrel medication. After dividing the 50 patients into two groups according to their response to clopidogrel INNOVANCE® PFA P2Y recognized all “responders” (defined by a PRI > 50%) using >106 s as cut-off but the specificity for a “good response” was only 42% because several “poor responders” (defined by a PRI > 50%) also showed CTs above the cut-off. The best correlation (substantial agreement) between the results of INNOVANCE® PFA P2Y and of the VASP phosphorylation assay was achieved using CT > 200 s and PRI < 55% as cut-offs. Then, the sensitivity of INNOVANCE® PFA P2Y was 97% and the specificity for a “good response” 65%. In summary, INNOVANCE® PFA P2Y showed a high sensitivity for the detection of P2Y12 receptor blockade, but had only a limited specificity for a “good response” to clopidogrel. Therefore, this new cartridge is a useful tool to rule out P2Y12 receptor inhibition, if normal or only slightly prolonged CTs are obtained. Its predictive value for risk assessment of thromboembolic events, e.g. after coronary stent implantation, needs to be evaluated in clinical trials.


Annals of Hematology | 2010

Assessment of clopidogrel non-response by the PFA-100 system using the new test cartridge INNOVANCE PFA P2Y.

Birgit Linnemann; Jan Schwonberg; Andreas Rechner; Helen Mani; Edelgard Lindhoff-Last


Archive | 2014

METHOD AND DEVICE FOR THE DETERMINATION OF PLATELET FUNCTION UNDER FLOW CONDITIONS

Andreas Rechner


Archive | 2007

Method for determination of platelet function under flow conditions

Andreas Rechner


Archive | 2008

Thromboplastin reagent with long-term stability

Andreas Rechner


Archive | 2012

Devices and Methods for Determining the Platelet Function in a Centrifugal Analyzer

Joerg Endermann; Andreas Rechner; Norbert Zander


Archive | 2012

Method and devices for determining the platelet function in a centrifugal analyser

Joerg Endermann; Norbert Zander; Andreas Rechner


Archive | 2011

Method of Determining Inhibitors of Coagulation

Andreas Kappel; Andreas Rechner; Sina Stephan; Thomas Dr. Wissel


Archive | 2010

In vitro method for determining the risk of and diagnosis of an arterial vascular disorder

Wolfgang R. Nitz; Andreas Rechner


Archive | 2012

Devices for determining the platelet function in a centrifugal analyzer

Joerg Endermann; Andreas Rechner; Norbert Zander

Collaboration


Dive into the Andreas Rechner's collaboration.

Top Co-Authors

Avatar

A. Schäfer

University of Regensburg

View shared research outputs
Top Co-Authors

Avatar

Birgit Linnemann

Goethe University Frankfurt

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Helen Mani

Goethe University Frankfurt

View shared research outputs
Top Co-Authors

Avatar

Jan Schwonberg

Goethe University Frankfurt

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge