Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Andreas Schatz is active.

Publication


Featured researches published by Andreas Schatz.


Proceedings of the Royal Society of London B: Biological Sciences | 2013

Artificial vision with wirelessly powered subretinal electronic implant alpha-IMS

Katarina Stingl; Karl Ulrich Bartz-Schmidt; Dorothea Besch; Angelika Braun; A. Bruckmann; Florian Gekeler; Udo Greppmaier; Stephanie Hipp; Gernot Hörtdörfer; Christoph Kernstock; Assen Koitschev; Akos Kusnyerik; Helmut G. Sachs; Andreas Schatz; Krunoslav Stingl; Tobias Peters; Barbara Wilhelm; Eberhart Zrenner

This study aims at substituting the essential functions of photoreceptors in patients who are blind owing to untreatable forms of hereditary retinal degenerations. A microelectronic neuroprosthetic device, powered via transdermal inductive transmission, carrying 1500 independent microphotodiode-amplifier-electrode elements on a 9 mm2 chip, was subretinally implanted in nine blind patients. Light perception (8/9), light localization (7/9), motion detection (5/9, angular speed up to 35 deg s−1), grating acuity measurement (6/9, up to 3.3 cycles per degree) and visual acuity measurement with Landolt C-rings (2/9) up to Snellen visual acuity of 20/546 (corresponding to decimal 0.037 or corresponding to 1.43 logMAR (minimum angle of resolution)) were restored via the subretinal implant. Additionally, the identification, localization and discrimination of objects improved significantly (n = 8; p < 0.05 for each subtest) in repeated tests over a nine-month period. Three subjects were able to read letters spontaneously and one subject was able to read letters after training in an alternative-force choice test. Five subjects reported implant-mediated visual perceptions in daily life within a field of 15° of visual angle. Control tests were performed each time with the implants power source switched off. These data show that subretinal implants can restore visual functions that are useful for daily life.


Investigative Ophthalmology & Visual Science | 2011

Transcorneal Electrical Stimulation for Patients with Retinitis Pigmentosa: A Prospective, Randomized, Sham-Controlled Exploratory Study

Andreas Schatz; Tobias Röck; Lubka Naycheva; Gabriel Willmann; Barbara Wilhelm; Tobias Peters; Karl Ulrich Bartz-Schmidt; Eberhart Zrenner; Andre Messias; Florian Gekeler

PURPOSE To assess the safety of transcorneal electrical stimulation (TES) and explore its efficacy in various subjective and objective parameters of visual function in patients with retinitis pigmentosa (RP). METHODS Twenty-four patients in this prospective, randomized, partially blinded, good-clinical-practice study underwent TES (5-ms biphasic pulses; 20 Hz; DTL electrodes) 30 minutes per week for 6 consecutive weeks. The patients were randomly assigned to one of three groups: sham, 66%, or 150% of individual electrical phosphene threshold (EPT). Visual acuity (VA), visual field (VF; kinetic, static), electroretinography (Ganzfeld, multifocal), dark-adaptation (DA), color discrimination, and EPTs were assessed at all visits or four times, according to the study plan. RESULTS TES using DTL electrodes was tolerated well; all patients finished the study. Two adverse (foreign body sensation), but no serious adverse events were encountered. There was a tendency for most functional parameters to improve (8/18) or to remain constant (8/18) in the 150% group. VF area and scotopic b-wave amplitude reached statistical significance (P < 0.027 and P < 0.001, respectively). Only desaturated color discrimination and VF mean sensitivity decreased. There was no obvious trend in the 66% group. CONCLUSIONS TES was found to be safe in RP patients. Positive trends were discovered, but due to the small sample size of this exploratory study, statistical significance was reached only for VF area and scotopic b-wave amplitude. Further studies with larger sample sizes and longer duration are needed to confirm the findings and to define optimal stimulation parameters. (ClinicalTrials.gov number, NCT00804102.).


Investigative Ophthalmology & Visual Science | 2011

Gene expression profiling of the retina after transcorneal electrical stimulation in wild-type Brown Norway rats.

Gabriel Willmann; Karin Schäferhoff; M. D. Fischer; Blanca Arango-Gonzalez; Sylvia Bolz; Lubka Naycheva; Tobias Röck; Michael Bonin; Karl U. Bartz-Schmidt; Eberhart Zrenner; Andreas Schatz; Florian Gekeler

PURPOSE Transcorneal electrical stimulation (TES) has been beneficial in several neurodegenerative ocular diseases, but the exact mechanisms remain to be elucidated. This study was conducted to investigate the effects of TES on the retinas of wild-type Brown Norway (BN) rats by gene expression profiling and to assess its effects on retinal function and morphology. METHODS TES was applied to BN wild-type rat retinas in vivo for 1 hour (1-ms biphasic pulses at 20 Hz; 200 μA). RNA was isolated and processed for microarray-based profiling 4 hours after TES; differentially expressed genes from TES compared with those from sham-treated animals were validated by quantitative real-time polymerase chain reaction. Furthermore, the effect of TES was assessed at the structural and functional levels using electroretinography, confocal scanning laser ophthalmoscopy, optical coherence tomography, and immunohistochemistry. RESULTS Transcriptome changes associated with TES versus sham-stimulated BN wild-type retina were identified. Four hundred ninety genes were differentially expressed in TES and included potentially neuroprotective genes such as Bax or members of the tumor necrosis factor family (Tnfrsf11b, Tnrsf12a, Tnfsf13b, Tnfsf13). ERG recordings showed physiological retinal function after TES, and structural in vivo and ex vivo studies revealed intact retinal anatomy. CONCLUSIONS These results demonstrate that TES applied to the retina of the wild-type BN rats induces distinct transcriptome level changes and may help in the understanding of the mechanisms underlying TES. In addition, TES treatment indicates no negative effect on structure and function of the wild-type BN retina up to 35 hours after application.


PLOS ONE | 2011

Quantification of optic disc edema during exposure to high altitude shows no correlation to acute mountain sickness.

Gabriel Willmann; M. Dominik Fischer; Andreas Schatz; Kai Schommer; Andre Messias; Eberhart Zrenner; Karl U. Bartz-Schmidt; Florian Gekeler

Background The study aimed to quantify changes of the optic nerve head (ONH) during exposure to high altitude and to assess a correlation with acute mountain sickness (AMS). This work is related to the Tuebingen High Altitude Ophthalmology (THAO) study. Methodology/Principal Findings A confocal scanning laser ophthalmoscope (cSLO, Heidelberg Retina Tomograph, HRT3®) was used to quantify changes at the ONH in 18 healthy participants before, during and after rapid ascent to high altitude (4559 m). Slitlamp biomicroscopy was used for clinical optic disc evaluation; AMS was assessed with Lake Louise (LL) and AMS-cerebral (AMS-c) scores; oxygen saturation (SpO2) and heart rate (HR) were monitored. These parameters were used to correlate with changes at the ONH. After the first night spent at high altitude, incidence of AMS was 55% and presence of clinical optic disc edema (ODE) 79%. Key stereometric parameters of the HRT3® used to describe ODE (mean retinal nerve fiber layer [RNFL] thickness, RNFL cross sectional area, optic disc rim volume and maximum contour elevation) changed significantly at high altitude compared to baseline (p<0.05) and were consistent with clinically described ODE. All changes were reversible in all participants after descent. There was no significant correlation between parameters of ODE and AMS, SpO2 or HR. Conclusions/Significance Exposure to high altitude leads to reversible ODE in the majority of healthy subjects. However, these changes did not correlate with AMS or basic physiologic parameters such as SpO2 and HR. For the first time, a quantitative approach has been used to assess these changes during acute, non-acclimatized high altitude exposure. In conclusion, ODE presents a reaction of the body to high altitude exposure unrelated to AMS.


Investigative Ophthalmology & Visual Science | 2012

Transcorneal electrical stimulation shows neuroprotective effects in retinas of light-exposed rats

Andreas Schatz; Blanca Arango-Gonzalez; Dominik Fischer; Heike Enderle; Sylvia Bolz; Tobias Röck; Lubka Naycheva; Christian Grimm; Andre Messias; Eberhart Zrenner; Karl Ulrich Bartz-Schmidt; Gabriel Willmann; Florian Gekeler

PURPOSE To examine the effects of transcorneal electrical stimulation (TES) on retinal degeneration of light-exposed rats. METHODS Thirty-three Sprague Dawley albino rats were divided into three groups: STIM (n = 15) received 60 minutes of TES, whereas SHAM (n = 15) received identical sham stimulation 2 hours before exposure to bright light with 16,000 lux; healthy animals (n = 3) served as controls for histology. At baseline and weekly for 3 consecutive weeks, dark- and light-adapted electroretinography was used to assess retinal function. Analysis of the response versus luminance function retrieved the parameters Vmax (saturation amplitude) and k (luminance to reach ½Vmax). Retinal morphology was assessed by histology (hematoxylin-eosin [HE] staining; TUNEL assay) and immunohistochemistry (rhodopsin staining). RESULTS Vmax was higher in the STIM group compared with SHAM 1 week after light damage (mean intra-individual difference between groups 116.06 μV; P = 0.046). The b-wave implicit time for the rod response (0.01 cd.s/m²) was lower in the STIM group compared with the SHAM group 2 weeks after light damage (mean intra-individual difference between groups 5.78 ms; P = 0.023); no other significant differences were found. Histological analyses showed photoreceptor cell death (TUNEL and HE) in SHAM, most pronounced in the superior hemiretina. STIM showed complete outer nuclear layer thickness preservation, reduced photoreceptor cell death, and preserved outer segment length compared with SHAM (HE and rhodopsin). CONCLUSIONS This sham-controlled study shows that TES can protect retinal cells against mild light-induced degeneration in Sprague Dawley rats. These findings could help to establish TES as a treatment in human forms of retinal degenerative disease.


Investigative Ophthalmology & Visual Science | 2012

Phosphene thresholds elicited by transcorneal electrical stimulation in healthy subjects and patients with retinal diseases.

Lubka Naycheva; Andreas Schatz; Tobias Röck; Gabriel Willmann; Andre Messias; Karl Ulrich Bartz-Schmidt; Eberhart Zrenner; Florian Gekeler

PURPOSE To evaluate electrically evoked phosphene thresholds (EPTs) in healthy subjects and in patients with retinal disease and to assess repeatability and possible correlations with common ophthalmologic tests. METHODS In all, 117 individuals participated: healthy subjects (n = 20) and patients with retinitis pigmentosa (RP, n = 30), Stargardts disease (STG, n = 14), retinal artery occlusion (RAO, n = 20), nonarteritic anterior ischemic optic neuropathy (NAION, n = 16), and primary open-angle glaucoma (POAG, n = 17). EPTs were determined at 3, 6, 9, 20, 40, 60, and 80 Hz with 5 + 5-ms biphasic current pulses using DTL electrodes. Subjects were examined twice (test-retest range: 1-6 weeks). An empirical model was developed to describe the current-frequency relationship of EPTs. Visual acuity, visual field (kinetic + static), electrophysiology (RP, RAO, STG: Ganzfeld-electroretinography [ERG]/multifocal-ERG; POAG: pattern-ERG; NAION: VEP), slit-lamp biomicroscopy, fundus examination, and tonometry were assessed. RESULTS EPTS varied between disease groups (20 HZ: healthy subjects: 0.062 ± 0.038 mA; STG: 0.102 ± 0.097 mA; POAG: 0.127 ± 0.09 mA; NAION: 0.244 ± 0.126 mA; RP: 0.371 ± 0.223 mA; RAO: 0.988 ± 1.142 mA). In all groups EPTs were lowest at 20 Hz. In patients with retinal diseases and across all frequencies EPTs were significantly higher than those in healthy subjects, except in STG at 20 Hz (P = 0.09) and 40 Hz (P = 0.17). Test-retest difference at 20 Hz was 0.006 mA in the healthy group and 0.003-0.04 mA in disease groups. CONCLUSIONS Considering the fast, safe, and reliable practicability of EPT testing, this test might be used more often under clinical circumstances. Determination of EPTs could be potentially useful in elucidation of the progress of ophthalmologic diseases, either in addition to standard clinical assessment or under conditions in which these standard tests cannot be used meaningfully. (ClinicalTrials.gov number, NCT00804102.).


PLOS ONE | 2012

Structural and Functional Changes of the Human Macula during Acute Exposure to High Altitude

M. Dominik Fischer; Gabriel Willmann; Andreas Schatz; Kai Schommer; Ahmad Zhour; Eberhart Zrenner; Karl U. Bartz-Schmidt; Florian Gekeler

Background This study aimed to quantify structural and functional changes at the macula during acute exposure to high altitude and to assess their structure/function relationship. This work is related to the Tuebingen High Altitude Ophthalmology (THAO) study. Methodology/Principal Findings Spectral domain optical coherence tomography and microperimetry were used to quantify changes of central retinal structure and function in 14 healthy subjects during acute exposure to high altitude (4559 m). High-resolution volume scans and fundus-controlled microperimetry of the posterior pole were performed in addition to best-corrected visual acuity (BCVA) measurements and assessment of acute mountain sickness. Analysis of measurements at altitude vs. baseline revealed increased total retinal thickness (TRT) in all four outer ETDRS grid subfields during acute altitude exposure (TRTouter = 2.80±1.00 μm; mean change±95%CI). This change was inverted towards the inner four subfields (TRTinner = −1.89±0.97 μm) with significant reduction of TRT in the fovea (TRTfoveal = −6.62±0.90 μm) at altitude. BCVA revealed no significant difference compared to baseline (0.06±0.08 logMAR). Microperimetry showed stable mean sensitivity in all but the foveal subfield (MSfoveal = −1.12±0.68 dB). At baseline recordings before and >2 weeks after high altitude exposure, all subjects showed equal levels with no sign of persisting structural or functional sequels. Conclusions/Significance During acute exposure to high altitude central retinal thickness is subject to minor, yet statistically significant changes. These alterations describe a function of eccentricity with an increase in regions with relatively higher retinal nerve fiber content and vascular arcades. However, these changes did not correlate with measures of central retinal function or acute mountain sickness. For the first time a quantitative approach has been used to assess these changes during acute, non-acclimatized high altitude exposure.


Annals of clinical and translational neurology | 2014

Missing correlation of retinal vessel diameter with high-altitude headache

Gabriel Willmann; M. Dominik Fischer; Kai Schommer; Peter Bärtsch; Florian Gekeler; Andreas Schatz

The most common altitude‐related symptom, high‐altitude headache (HAH), has recently been suggested to originate from restricted cerebral venous drainage in the presence of increased inflow caused by hypoxia. In support of this novel hypothesis, retinal venous distension was shown to correlate with the degree of HAH. We quantified for the first time retinal vessel diameter changes at 4559 m using infrared fundus images obtained from a state of the art Spectralis™ HRA+OCT with a semiautomatic VesselMap 1® software. High‐altitude exposure resulted in altered arterial and venous diameter changes at high altitude, however, independent of headache burden.


Graefes Archive for Clinical and Experimental Ophthalmology | 2012

GDF-15: a novel serum marker for metastases in uveal melanoma patients

Daniela Suesskind; Andreas Schatz; Sven Schnichels; Sarah E. Coupland; Sarah L. Lake; Bernd Wissinger; Karl U. Bartz-Schmidt; Sigrid Henke-Fahle

BackgroundAbout 50% of patients with uveal melanoma (UM) develop metastases during the course of their disease. We analyzed serum levels of Growth Differentiation Factor-15 (GDF-15), with the aim of identifying patients with early metastases.MethodsGDF-15 concentration was measured using an enzyme-linked immunosorbent assay (ELISA) in serum samples from 188 UM patients (170 patients without metastases; 18 patients with clinically detectable metastases) and 18 healthy control individuals. Data were analyzed with respect to differences between patients with and without clinically detectable UM metastases. GDF-15 serum levels were further analyzed with regard to significant patient and tumor characteristics as revealed by histology and multiplex ligation-dependent probe amplification (MLPA) to determine chromosome 3 copy number. GDF-15 expression in UM was investigated by immunohistochemistry.ResultsPatients with clinically detectable metastases had significantly higher GDF-15 serum levels compared to those without clinically detectable metastases as well as to healthy individuals (ANOVA; p < 0.001). GDF-15 concentrations in UM patients with overt clinically detectable metastases were significantly higher than those in UM patients with a second malignancy in remission but without clinically detected UM metastases (ANOVA; p < 0.001). No association between serum concentration of GDF-15 and clinical, pathological, and genetic features was observed. GDF-15 protein was only expressed in a minority of UM cells in most tumors.ConclusionsOur data suggest that GDF-15 can be used as a serum marker for the diagnosis of metastases in UM patients. Further data collection and analysis are necessary to evaluate a possible prognostic role of GDF-15 in predicting early metastases.


Journal of Cataract and Refractive Surgery | 2012

Sulcus anatomy and diameter in pseudophakic eyes and correlation with biometric data: evaluation with a 50 MHz ultrasound biomicroscope.

Katrin Petermeier; Daniela Suesskind; Elke Altpeter; Andreas Schatz; Andre Messias; Florian Gekeler; Peter Szurman

PURPOSE: To evaluate the sulcus anatomy and possible correlations between sulcus diameter and white‐to‐white (WTW) diameter in pseudophakic eyes, data that may be important in the stability of add‐on intraocular lenses (IOLs). SETTING: University Eye Hospital, Tuebingen, Germany. DESIGN: Case series. METHODS: In pseudophakic eyes, the axial length (AL) and horizontal WTW were measured by the IOLMaster device. Cross‐sectional images were obtained with a 50 MHz ultrasound biomicroscope on the 4 meridians: vertical, horizontal (180 degrees), temporal oblique, and nasal oblique. Sulcus‐to‐sulcus (STS), angle‐to‐angle (ATA), and sclera‐to‐sclera (ScTSc) diameters were measured. The IOL optic diameter (6.0 mm) served as a control. To test reliability, optic measurements were repeated 5 times in a subset of eyes. RESULTS: The vertical ATA and STS diameters were statistically significantly larger than the horizontal diameter (P=.0328 and P=.0216, respectively). There was no statistically significant difference in ScTSc diameters. A weak correlation was found between WTW and horizontal ATA (r = 0.5766, P<.0001) and between WTW and horizontal STS (r = 0.5040, P=.0002). No correlation was found between WTW and horizontal ScTSc (r = 0.2217, P=.1217). CONCLUSIONS: The sulcus anatomy had a vertical oval shape with the vertical meridian being the largest, but it also had variation in the direction of the largest meridian. The WTW measurements showed a weak correlation with STS. In pseudophakic eyes, Soemmerring ring or a bulky haptic may affect the ciliary sulcus anatomy. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned.

Collaboration


Dive into the Andreas Schatz's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Kai Schommer

University Hospital Heidelberg

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Andre Messias

University of São Paulo

View shared research outputs
Top Co-Authors

Avatar

Tobias Röck

University of Tübingen

View shared research outputs
Researchain Logo
Decentralizing Knowledge