Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Andreas Schicho.
PeerJ | 2016
Lukas Philipp Beyer; Benedikt Pregler; Christoph Nießen; Andreas Schicho; Michael Haimerl; Ernst Michael Jung; Christian Stroszczynski; Philipp Wiggermann
Purpose. The purpose of this study was to compare CT-navigated stereotactic IRE (SIRE) needle placement to non-navigated conventional IRE (CIRE) for percutaneous ablation of liver malignancies. Materials and Methods. A prospective trial including a total of 20 patients was conducted with 10 patients in each arm of the study. IRE procedures were guided using either CT fluoroscopy (CIRE) or a stereotactic planning and navigation system (SIRE). Primary endpoint was procedure time. Secondary endpoints were accuracy of needle placement, technical success rate, complication rate and dose-length product (DLP). Results. A total of 20 IRE procedures were performed to ablate hepatic malignancies (16 HCC, 4 liver metastases), 10 procedures in each arm. Mean time for placement of IRE electrodes in SIRE was significantly shorter with 27 ± 8 min compared to 87 ± 30 min for CIRE (p < 0.001). Accuracy of needle placement for SIRE was higher than CIRE (2.2 mm vs. 3.3 mm mean deviation, p < 0.001). The total DLP and the fluoroscopy DLP were significantly lower in SIRE compared to CIRE. Technical success rate and complication rates were equal in both arms. Conclusion. SIRE demonstrated a significant reduction of procedure length and higher accuracy compared to CIRE. Stereotactic navigation has the potential to reduce radiation dose for the patient and the radiologist without increasing the risk of complications or impaired technical success compared to CIRE.
Oncotarget | 2017
Andreas Schicho; Philippe L. Pereira; Michael Haimerl; Christoph Niessen; Katharina Michalik; Lukas Philipp Beyer; Christian Stroszczynski; Philipp Wiggermann
Background Hepatocellular carcinoma (HCC) is the 3rd leading cause of cancer-related death worldwide. The majority of HCCs are diagnosed in a stage that is not eligible for curative resection. For intermediate stage HCC, transarterial chemoembolization (TACE) is the recommended treatment. We evaluated the safety and efficacy of DSM (degradable starch microspheres) as embolic agent in transarterial chemoembolization (TACE) for the treatment of intermediate stage, non-resectable hepatocellular carcinoma (HCC). Methods and Findings A national, multi-center observational study on the safety and efficacy of DSM-TACE for the treatment of intermediate HCC was conducted. The recruitment period for the study was from January 2010 to June 2014. The primary endpoints were safety and treatment response according to the mRECIST criteria. A total of 179 DSM-TACE procedures in 50 patients were included in the analysis. The therapeutic efficacy assessed with mRECIST was as follows: complete response (n=1; 2 %), 21 partial response (42 %), 13 stable disease (26 %), 9 progressive disease (18 %), and 6 incomplete data (12 %). Thus, the objective response rate was 44% (n=22) and disease control rate was 70% (n=35). A total of 76 immediate adverse events (AE) and 2 severe adverse events (SAE) were recorded. Forty-eight percent of patients (n=24) did not encounter any immediate AE/SAE. Between treatments, a total of 66 AE and one SAE were recorded. Twenty-four patients (48 %) did not encounter any AE/SAE in between treatments. Conclusion The use of DSM as a TACE embolic agent appears to be safe for the treatment of HCC and has promising efficacy.
Clinics and practice | 2017
Andreas Schicho; Christian Stroszczynski; Philipp Wiggermann
Although high mortality rates have been reported for emphysematous pyelonephritis (EP), information on emphysematous cystitis (EC), which is less common, is sparse. Here, we report one new case of severe EC and 136 cases of EC that occurred between 2007 and 2016, and review information about the characteristics, diagnosis, treatment and mortality of these patients, and the pathogens found in these patients. The mean age of the 136 patients was 67.9±14.2 years. Concurrent emphysematous infections of other organs were found in 21 patients (15.4%), with emphysematous pyelonephritis being the most common of these infections. The primary pathogen identified was Escherichia coli (54.4%). Patients were mainly treated by conservative management that included antibiotics (n=105; 77.2%). Ten of the 136 patients with EC died, yielding a mortality rate of 7.4%. Despite the relatively low mortality rate of EC compared with that of EP, a high degree of suspicion must be maintained to facilitate successful and conservative management.
Therapeutics and Clinical Risk Management | 2018
Andreas Schicho; Lukas Luerken; Ramona Meier; Antonio Ernstberger; Christian Stroszczynski; Andreas G. Schreyer; Lena-Marie Dendl; Stephan Schleder
Purpose The aim of this study was to evaluate the true incidence of cervical artery dissections (CeADs) in trauma patients with an Injury Severity Score (ISS) of ≥16, since head-and-neck computed tomography angiogram (CTA) is not a compulsory component of whole-body trauma computed tomography (CT) protocols. Patients and methods A total of 230 consecutive trauma patients with an ISS of ≥16 admitted to our Level I trauma center during a 24-month period were prospectively included. Standardized whole-body CT in a 256-detector row scanner included a head-and-neck CTA. Incidence, mortality, patient and trauma characteristics, and concomitant injuries were recorded and analyzed retrospectively in patients with carotid artery dissection (CAD) and vertebral artery dissection (VAD). Results Of the 230 patients included, 6.5% had a CeAD, 5.2% had a CAD, and 1.7% had a VAD. One patient had both CAD and VAD. For both, CAD and VAD, mortality is 25%. One death was caused by fatal cerebral ischemia due to high-grade CAD. A total of 41.6% of the patients with traumatic CAD and 25% of the patients with VAD had neurological sequelae. Conclusion Mandatory head-and-neck CTA yields higher CeAD incidence than reported before. We highly recommend the compulsory inclusion of a head-and-neck CTA to whole-body CT routines for severely injured patients.
Acta Radiologica | 2018
Andreas Schicho; Lukas Lürken; Ramona Meier; Christian Stroszczynski; Andreas G. Schreyer; Lena-Marie Dendl; Stephan Schleder
Background In severely injured trauma patients, non-penetrating aortic arch injuries (NAAI) have a remarkable incidence and mortality. Both diagnostics and therapy of NAAI recently underwent significant changes. Purpose To assess mortality, morbidity, and the risk factors associated with NAAI in severely injured patients (Injury Severity Score [ISS] ≥16) under the light of recent technical and procedural advances in trauma care. Material and Methods A total of 230 consecutive trauma patients with ISS ≥16 admitted to our level-I trauma center during a 24-month period, were prospectively included and underwent standardized whole-body computed tomography (CT) in a 2 × 128-detector-row scanner. Incidence, mortality, patient and trauma characteristics, and concomitant injuries were recorded for patients with NAAI. Localization of NAAI was described referring to Mitchell and Ishimaru; severity was graded according to the proposal of Heneghan et al. Results Thirteen of 230 patients had a NAAI, yielding an incidence of 5.6%. Mean age and ISS was not elevated in NAAI (44.4 ± 14.8 years, ISS = 38 ± 12.4). Mortality was 23.1%. One patient had severe neurologic sequelae from a stroke; all surviving patients had to undergo (transient) anticoagulant therapy. Trauma mechanism was of high kinetic energy in all cases. Concomitant injuries were predominantly thoracic (rib fractures = 76.9%, thoracic spine fracture = 38.5%). Conclusion Whenever an individual possibly encountered a deceleration–acceleration trauma mechanism, a high level of suspicion for NAAI should be maintained. It remains to be determined whether recent advances in mortality are due to changes in trauma care or due to improved vehicle and road safety.
OncoTargets and Therapy | 2018
Andreas Schicho; Philippe L. Pereira; Katharina Michalik; Lukas Philipp Beyer; Christian Stroszczynski; Philipp Wiggermann
Purpose To evaluate the safety and efficacy of degradable starch microspheres (DSM) as embolic agents in transarterial chemoembolization (TACE) in the treatment of secondary liver metastases. Methods This was a national, multicenter observational study. Primary endpoints were safety and treatment response according to Modified Response Evaluation Criteria in Solid Tumors (mRECIST) criteria. Results A total of 77 DSM-TACE procedures were performed in 20 patients. Minor immediate adverse events (AEs) were epigastric pain with an incidence of 45.5% (35/77), and nausea and vomiting at an incidence of 23.4% (18/77). Delayed minor AEs were epigastric pain in 13/77 (16.9%) treatments and nausea and vomiting in 10 (13.0%) treatments. No severe AEs were documented. Therapeutic efficacy of DSM-TACE procedures according to mRECIST was as follows: complete response 0/77, partial response 17/77, stable disease 33/77 and progressive disease 6/77, no data was available for 21/77 treatments. Overall, objective response was achieved in 8 of 20 patients (40.0%). Conclusion DSM as embolic agent for TACE is safe in the treatment of liver metastases. An objective response in 40.0% of patients and disease control in 64.9% of procedures was achieved, and this should lead to further evaluation of DSM-TACE as treatment option for nonresectable liver metastases.
PLOS ONE | 2017
Andreas Schicho; Lukas Luerken; Christian Stroszczynski; Ramona Meier; Andreas G. Schreyer; Lena-Marie Dendl; Stephan Schleder
Purpose To assess biomechanical factors in aortic arch geometry contributing to the development of non-penetrating aortic arch injury (NAAI) in multiply injured patients with an Injury Severity Score (ISS) ≥ 16. Material and methods 230 consecutive multiply injured trauma patients with an ISS ≥ 16 admitted to our Level-I trauma center during a consecutive 24-month period were prospectively included of whom 13 presented with NAAI (5.7%). Standardized whole-body CT in a 2x128-detector-row scanner included a head-and-neck CTA. Aortic arch diameters, width, height, angles and thoracic width and height were measured in individuals with NAAI and ISS-, sex-, age-, and trauma mechanism-matched controls. Results There was no difference between groups regarding sex, age, ISS, and aortic diameters. The aortic arch angle in individuals with NAAI (71.3° ± 14.9°) was larger than in healthy control (60.7° ± 8.6°; p*<0.05). In patients with NAAI, the distance between ascendent and descendent aorta was larger (5.2 cm ± 1.9 cm) than in control (2.8 ± 0.5 cm; ***p<0.001). The aortic arch is higher above tracheal bifurcation in NAAI (3.6 cm ± 0.6 cm) than in matched control (2.4 cm ± 0.3 cm; ***p<0.001). Accordingly, the area under the aortic arch, calculated as half of an eliptic shape, is significantly larger in patients with NAAI (15.0 cm2 ± 6.5 cm2) when compared to age- and sex-matched controls without NAAI (5.5 cm2 ± 1.3 cm2; ***p<0.001). Conclusion Besides the magnitude of deceleration and direction of impact, width and height of the aortic arch are the 3rd and 4th factor directly contributing to the risk of developing traumatic NAAI in severely injured patients.
Medical Science Monitor | 2017
Andreas Schicho; Philippe L. Pereira; Manfred Pützler; Katharina Michalik; Thomas Albrecht; Claus Nolte-Ernsting; Christian Stroszczynski; Philipp Wiggermann
Background The aim of this study was to evaluate the safety and efficacy of DSM (degradable starch microspheres) as an embolic agent in transarterial chemoembolization in the treatment of intrahepatic cholangiocellular carcinoma (ICC). Material/Methods This was a national, multi-center observational cohort study on the safety and efficacy of DSM-TACE using mitomycin, gemcitabine, cisplatin, doxorubicin, and carboplatin in palliative treatment of ICC. Recruitment period for the study was from January 2010 to June 2014. Primary endpoints were toxicity, safety, and response according to mRECIST criteria. Results Twenty-five DSM-TACE procedures in cases of advanced ICC were performed in seven patients. Nausea and vomiting occurred as adverse event (AE) in eight out of 25 treatments (32%), with seven of eight events (87.5%) associated with the use of gemcitabine. In 11 out of 25 treatments (44%) moderate, transient epigastric pain was registered as an adverse event (AE) within 24 hours of DSM-TACE. One case (1/25) of severe AE (4%) with thrombocytopenia led to discontinuation of the DSM-TACE-treatment. A total of 25 DSM-TACE procedures with complete clinical and imaging follow-up over a two-year-period were analyzed: objective response (OR) was achieved in three of 25 treatments (12%) Disease control (DC) was achieved in 44% (11/25) of treatments; progress was registered in 4% (1/25). Conclusions The use of DSM as an embolic agent for TACE is safe in the treatment of ICC. A standardized anti-emetic medication should be established, especially when using gemcitabine. Further prospective studies need to be conducted to find the most suitable, standardized DSM-TACE treatment regime.
Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren | 2018
Wolf Bäumler; Andreas Schicho; Andreas G. Schreyer
Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren | 2017
Andreas Schicho; C Hellerbrand; W Wohlgemuth; Christian Stroszczynski; Philipp Wiggermann; P Pereira