Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Andrew D Scott is active.

Publication


Featured researches published by Andrew D Scott.


Radiology | 2009

Motion in Cardiovascular MR Imaging

Andrew D Scott; Jennifer Keegan; David N. Firmin

Modern rapid magnetic resonance (MR) imaging techniques have led to widespread use of the modality in cardiac imaging. Despite this progress, many MR studies suffer from image degradation due to involuntary motion during the acquisition. This review describes the type and extent of the motion of the heart due to the cardiac and respiratory cycles, which create image artifacts. Methods of eliminating or reducing the problems caused by the cardiac cycle are discussed, including electrocardiogram gating, subject-specific acquisition windows, and section tracking. Similarly, for respiratory motion of the heart, techniques such as breath holding, respiratory gating, section tracking, phase-encoding ordering, subject-specific translational models, and a range of new techniques are considered.


Journal of Cardiovascular Magnetic Resonance | 2012

Reproducibility of in-vivo diffusion tensor cardiovascular magnetic resonance in hypertrophic cardiomyopathy

Laura-Ann McGill; Tevfik F Ismail; Sonia Nielles-Vallespin; Pedro Ferreira; Andrew D Scott; Michael Roughton; Philip J. Kilner; S. Yen Ho; Karen P. McCarthy; Peter D. Gatehouse; Ranil de Silva; Peter Speier; Thorsten Feiweier; Choukkri Mekkaoui; David E. Sosnovik; Sanjay Prasad; David N. Firmin; Dudley J. Pennell

BackgroundMyocardial disarray is an important histological feature of hypertrophic cardiomyopathy (HCM) which has been studied post-mortem, but its in-vivo prevalence and extent is unknown. Cardiac Diffusion Tensor Imaging (cDTI) provides information on mean intravoxel myocyte orientation and potentially myocardial disarray. Recent technical advances have improved in-vivo cDTI, and the aim of this study was to assess the interstudy reproducibility of quantitative in-vivo cDTI in patients with HCM.Methods and resultsA stimulated-echo single-shot-EPI sequence with zonal excitation and parallel imaging was implemented. Ten patients with HCM were each scanned on 2 different days. For each scan 3 short axis mid-ventricular slices were acquired with cDTI at end systole. Fractional anisotropy (FA), mean diffusivity (MD), and helix angle (HA) maps were created using a cDTI post-processing platform developed in-house. The mean ± SD global FA was 0.613 ± 0.044, MD was 0.750 ± 0.154 × 10-3 mm2/s and HA was epicardium −34.3 ± 7.6°, mesocardium 3.5 ± 6.9° and endocardium 38.9 ± 8.1°. Comparison of initial and repeat studies showed global interstudy reproducibility for FA (SD = ± 0.045, Coefficient of Variation (CoV) = 7.2%), MD (SD = ± 0.135 × 10-3 mm2/s, CoV = 18.6%) and HA (epicardium SD = ± 4.8°; mesocardium SD = ± 3.4°; endocardium SD = ± 2.9°). Reproducibility of FA was superior to MD (p = 0.003). Global MD was significantly higher in the septum than the reference lateral wall (0.784 ± 0.188 vs 0.750 ± 0.154 x10-3 mm2/s, p < 0.001). Septal HA was significantly lower than the reference lateral wall in all 3 transmural layers (from −8.3° to −10.4°, all p < 0.001).ConclusionsTo the best of our knowledge, this is the first study to assess the interstudy reproducibility of DTI in the human HCM heart in-vivo and the largest cDTI study in HCM to date. Our results show good reproducibility of FA, MD and HA which indicates that current technology yields robust in-vivo measurements that have potential clinical value. The interpretation of regional differences in the septum requires further investigation.


Journal of Cardiovascular Magnetic Resonance | 2014

In vivo cardiovascular magnetic resonance diffusion tensor imaging shows evidence of abnormal myocardial laminar orientations and mobility in hypertrophic cardiomyopathy

Pedro Ferreira; Philip J. Kilner; Laura-Ann McGill; Sonia Nielles-Vallespin; Andrew D Scott; Siew Yen Ho; Karen P. McCarthy; Margarita M Haba; Tevfik F Ismail; Peter D. Gatehouse; Ranil de Silva; Alexander R. Lyon; Sanjay Prasad; David N. Firmin; Dudley J. Pennell

BackgroundCardiac diffusion tensor imaging (cDTI) measures the magnitudes and directions of intramyocardial water diffusion. Assuming the cross-myocyte components to be constrained by the laminar microstructures of myocardium, we hypothesized that cDTI at two cardiac phases might identify any abnormalities of laminar orientation and mobility in hypertrophic cardiomyopathy (HCM).MethodsWe performed cDTI in vivo at 3 Tesla at end-systole and late diastole in 11 healthy controls and 11 patients with HCM, as well as late gadolinium enhancement (LGE) for detection of regional fibrosis.ResultsVoxel-wise analysis of diffusion tensors relative to left ventricular coordinates showed expected transmural changes of myocardial helix-angle, with no significant differences between phases or between HCM and control groups. In controls, the angle of the second eigenvector of diffusion (E2A) relative to the local wall tangent plane was larger in systole than diastole, in accord with previously reported changes of laminar orientation. HCM hearts showed higher than normal global E2A in systole (63.9° vs 56.4° controls, p =0.026) and markedly raised E2A in diastole (46.8° vs 24.0° controls, p < 0.001). In hypertrophic regions, E2A retained a high, systole-like angulation even in diastole, independent of LGE, while regions of normal wall thickness did not (LGE present 57.8°, p =0.0028, LGE absent 54.8°, p =0.0022 vs normal thickness 38.1°).ConclusionsIn healthy controls, the angles of cross-myocyte components of diffusion were consistent with previously reported transmural orientations of laminar microstructures and their changes with contraction. In HCM, especially in hypertrophic regions, they were consistent with hypercontraction in systole and failure of relaxation in diastole. Further investigation of this finding is required as previously postulated effects of strain might be a confounding factor.


British Journal of Radiology | 2012

In vitro and in vivo repeatability of abdominal diffusion-weighted MRI

Marc E. Miquel; Andrew D Scott; N D Macdougall; Redha Boubertakh; N Bharwani; A G Rockall

OBJECTIVE To study the in vitro and in vivo (abdomen) variability of apparent diffusion coefficient (ADC) measurements at 1.5 T using a free-breathing multislice diffusion-weighted (DW) MRI sequence. METHODS DW MRI images were obtained using a multislice spin-echo echo-planar imaging sequence with b-values=0, 100, 200, 500, 750 and 1000 s mm(-2). A flood-field phantom was imaged at regular intervals over 100 days, and 10 times on the same day on 2 occasions. 10 healthy volunteers were imaged on two separate occasions. Mono-exponential ADC maps were fitted excluding b=0. Paired analysis was carried out on the liver, spleen, kidney and gallbladder using multiple regions of interest (ROIs) and volumes of interest (VOIs). RESULTS The in vitro coefficient of variation was 1.3% over 100 days, and 0.5% and 1.0% for both the daily experiments. In vivo, there was no statistical difference in the group mean ADC value between visits for any organ. Using ROIs, the coefficient of reproducibility was 20.0% for the kidney, 21.0% for the gallbladder, 24.7% for the liver and 28.0% for the spleen. For VOIs, values fall to 7.7%, 6.4%, 8.6% and 9.6%, respectively. CONCLUSION Good in vitro repeatability of ADC measurements provided a sound basis for in vivo measurement. In vivo variability is higher and when considering single measurements in the abdomen as a whole, only changes in ADC value greater than 23.1% would be statistically significant using a two-dimensional ROI. This value is substantially lower (7.9%) if large three-dimensional VOIs are considered.


Physica Medica | 2014

Speech MRI: Morphology and function

Andrew D Scott; Marzena Wylezinska; Malcolm J. Birch; Marc E. Miquel

Magnetic Resonance Imaging (MRI) plays an increasing role in the study of speech. This article reviews the MRI literature of anatomical imaging, imaging for acoustic modelling and dynamic imaging. It describes existing imaging techniques attempting to meet the challenges of imaging the upper airway during speech and examines the remaining hurdles and future research directions.


British Journal of Radiology | 2012

Towards clinical assessment of velopharyngeal closure using MRI: evaluation of real-time MRI sequences at 1.5 and 3 T

Andrew D Scott; Redha Boubertakh; Malcolm J. Birch; Marc E. Miquel

OBJECTIVE The objective of this study was to demonstrate soft palate MRI at 1.5 and 3 T with high temporal resolution on clinical scanners. METHODS Six volunteers were imaged while speaking, using both four real-time steady-state free-precession (SSFP) sequences at 3 T and four balanced SSFP (bSSFP) at 1.5 T. Temporal resolution was 9-20 frames s(-1) (fps), spatial resolution 1.6 × 1.6 × 10.0-2.7 × 2.7 × 10.0 mm(3). Simultaneous audio was recorded. Signal-to-noise ratio (SNR), palate thickness and image quality score (1-4, non-diagnostic-excellent) were evaluated. RESULTS SNR was higher at 3 T than 1.5 T in the relaxed palate (nasal breathing position) and reduced in the elevated palate at 3 T, but not 1.5 T. Image quality was not significantly different between field strengths or sequences (p=NS). At 3 T, 40% acquisitions scored 2 and 56% scored 3. Most 1.5 T acquisitions scored 1 (19%) or 4 (46%). Image quality was more dependent on subject or field than sequence. SNR in static images was highest with 1.9 × 1.9 × 10.0 mm(3) resolution (10 fps) and measured palate thickness was similar (p=NS) to that at the highest resolution (1.6 × 1.6 × 10.0 mm(3)). SNR in intensity-time plots through the soft palate was highest with 2.7 × 2.7 × 10.0 mm(3) resolution (20 fps). CONCLUSIONS At 3 T, SSFP images are of a reliable quality, but 1.5 T bSSFP images are often better. For geometric measurements, temporal should be traded for spatial resolution (1.9 × 1.9 × 10.0 mm(3), 10 fps). For assessment of motion, temporal should be prioritised over spatial resolution (2.7 × 2.7 × 10.0 mm(3), 20 fps). Advances in knowledge Diagnostic quality real-time soft palate MRI is possible using clinical scanners and optimised protocols have been developed. 3 T SSFP imaging is reliable, but 1.5 T bSSFP often produces better images.


Magnetic Resonance in Medicine | 2015

Optimal diffusion weighting for in vivo cardiac diffusion tensor imaging

Andrew D Scott; Pedro Ferreira; Sonia Nielles-Vallespin; Peter D. Gatehouse; Laura-Ann McGill; Philip J. Kilner; Dudley J. Pennell; David N. Firmin

To investigate the influence of the diffusion weighting on in vivo cardiac diffusion tensor imaging (cDTI) and obtain optimal parameters.


Magnetic Resonance Imaging | 2011

Beat-to-beat respiratory motion correction with near 100% efficiency: a quantitative assessment using high-resolution coronary artery imaging

Andrew D Scott; Jennifer Keegan; David N. Firmin

This study quantitatively assesses the effectiveness of retrospective beat-to-beat respiratory motion correction (B2B-RMC) at near 100% efficiency using high-resolution coronary artery imaging. Three-dimensional (3D) spiral images were obtained in a coronary respiratory motion phantom with B2B-RMC and navigator gating. In vivo, targeted 3D coronary imaging was performed in 10 healthy subjects using B2B-RMC spiral and navigator gated balanced steady-state free-precession (nav-bSSFP) techniques. Vessel diameter and sharpness in proximal and mid arteries were used as a measure of respiratory motion compensation effectiveness and compared between techniques. Phantom acquisitions with B2B-RMC were sharper than those acquired with navigator gating (B2B-RMC vs. navigator gating: 1.01±0.02 mm−1 vs. 0.86±0.08 mm−1, P<.05). In vivo B2B-RMC respiratory efficiency was significantly and substantially higher (99.7%±0.5%) than nav-bSSFP (44.0%±8.9%, P<.0001). Proximal and mid vessel sharpnesses were similar (B2B-RMC vs. nav-bSSFP, proximal: 1.00±0.14 mm−1 vs. 1.08±0.11 mm−1, mid: 1.01±0.11 mm−1 vs. 1.05±0.12 mm−1; both P=not significant [ns]). Mid vessel diameters were not significantly different (2.85±0.39 mm vs. 2.80±0.35 mm, P=ns), but proximal B2B-RMC diameters were slightly higher (2.85±0.38 mm vs. 2.70±0.34 mm, P<.05), possibly due to contrast differences. The respiratory efficiency of B2B-RMC is less variable and significantly higher than navigator gating. Phantom and in vivo vessel sharpness and diameter values suggest that respiratory motion compensation is equally effective.


Magnetic Resonance in Medicine | 2013

Adaptive averaging applied to dynamic imaging of the soft palate

Andrew D Scott; Redha Boubertakh; Malcolm J. Birch; Marc E. Miquel

Achieving sufficient temporal and spatial resolution with adequate signal‐to‐noise ratio (SNR) in dynamic soft palate imaging is challenging. Triggered acquisitions require repeated reproducible speech samples, and while real‐time imaging is more reliable, it may lack SNR. Adaptive averaging was implemented to improve SNR in nongated imaging during repetition of a speech task. Similar images were identified using localized cross‐correlation before averaging. Adaptive averaging was applied to the soft palate region of images from six volunteers and one patient acquired with various sequences. In volunteers, soft palate SNR increased by 53 ± 17% with four averages. The additional SNR was used to enable reduced slice thickness in two example subjects. Adaptive averaging was also compared to pseudotriggered images in one example and, in another, it was applied to an unrepeated speech task. In a patient with a repaired cleft palate, the technique was used to demonstrate residual velopharyngeal insufficiency. This initial work demonstrates that increased temporal or spatial resolution may be traded for reduced SNR, which can be recovered using adaptive averaging. This will be a valuable tool in assessing velopharyngeal function, particularly in pediatric patients where cooperation may make gated studies difficult or when their head sizes require increased spatial resolution while maintaining temporal resolution. Magn Reson Med 70:865–874, 2013.


NMR in Biomedicine | 2016

The effects of noise in cardiac diffusion tensor imaging and the benefits of averaging complex data.

Andrew D Scott; Sonia Nielles-Vallespin; Pedro Ferreira; Laura-Ann McGill; Dudley J. Pennell; David N. Firmin

There is growing interest in cardiac diffusion tensor imaging (cDTI), but, unlike other diffusion MRI applications, there has been little investigation of the effects of noise on the parameters typically derived. One method of mitigating noise floor effects when there are multiple image averages, as in cDTI, is to average the complex rather than the magnitude data, but the phase contains contributions from bulk motion, which must be removed first. The effects of noise on the mean diffusivity (MD), fractional anisotropy (FA), helical angle (HA) and absolute secondary eigenvector angle (E2A) were simulated with various diffusion weightings (b values). The effect of averaging complex versus magnitude images was investigated. In vivo cDTI was performed in 10 healthy subjects with b = 500, 1000, 1500 and 2000 s/mm2. A technique for removing the motion‐induced component of the image phase present in vivo was implemented by subtracting a low‐resolution copy of the phase from the original images before averaging the complex images. MD, FA, E2A and the transmural gradient in HA were compared for un‐averaged, magnitude‐ and complex‐averaged reconstructions. Simulations demonstrated an over‐estimation of FA and MD at low b values and an under‐estimation at high b values. The transition is relatively signal‐to‐noise ratio (SNR) independent and occurs at a higher b value for FA (b = 1000–1250 s/mm2) than MD (b ≈ 250 s/mm2). E2A is under‐estimated at low and high b values with a transition at b ≈ 1000 s/mm2, whereas the bias in HA is comparatively small. The under‐estimation of FA and MD at high b values is caused by noise floor effects, which can be mitigated by averaging the complex data. Understanding the parameters of interest and the effects of noise informs the selection of the optimal b values. When complex data are available, they should be used to maximise the benefit from the acquisition of multiple averages. The combination of complex data is also a valuable step towards segmented acquisitions. Copyright

Collaboration


Dive into the Andrew D Scott's collaboration.

Top Co-Authors

Avatar

David N. Firmin

National Institutes of Health

View shared research outputs
Top Co-Authors

Avatar

Pedro Ferreira

National Institutes of Health

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Dudley J. Pennell

National Institutes of Health

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Peter D. Gatehouse

National Institutes of Health

View shared research outputs
Top Co-Authors

Avatar

Philip J. Kilner

National Institutes of Health

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Ranil de Silva

National Institutes of Health

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge