Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Andrew E. Hanselman is active.

Publication


Featured researches published by Andrew E. Hanselman.


Foot & Ankle International | 2015

Cryopreserved human amniotic membrane injection for plantar fasciitis: a randomized, controlled, double-blind pilot study.

Andrew E. Hanselman; John E. Tidwell; Robert D. Santrock

Background: Treatment options for plantar fasciitis have resulted in varied patient outcomes. The aim of this study was to compare a novel treatment, cryopreserved human amniotic membrane (c-hAM), to a traditional treatment, corticosteroid. Our hypothesis was that c-hAM would be safe and comparable to corticosteroids for plantar fasciitis in regard to patient outcomes. Methods: A randomized, controlled, double-blind, single-center pilot study was completed. Patients were randomized into one of 2 treatment groups: c-hAM or corticosteroid. Patients received an injection at their initial baseline visit with an option for a second injection at their first 6-week follow-up. Total follow-up was obtained for 12 weeks after the most recent injection. The primary outcome measurement was the Foot Health Status Questionnaire (FHSQ). The secondary outcome measurements were the Visual Analog Scale (VAS) and verbally reported percentage improvement. Data were analyzed between groups for the 2 different cohorts (1 injection versus 2 injections). Twenty-three patients had complete follow-up. Fourteen were randomized to receive corticosteroid and 9 were randomized to receive c-hAM. Results: Three patients in each group received second injections. With the numbers available, the majority of outcome measurements showed no statistical difference between groups. The corticosteroid did, however, have greater FHSQ shoe fit improvement (P = .0244) at 6 weeks, FHSQ general health improvement (P = .0132) at 6 weeks, and verbally reported improvement (P = .041) at 12 weeks in the one-injection cohort. Cryopreserved hAM had greater FHSQ foot pain improvement (P = .0113) at 18 weeks in the 2-injection cohort. Conclusion: Cryopreserved hAM injection may be safe and comparable to corticosteroid injection for treatment of plantar fasciitis. This is a pilot study and requires further investigation. Level of Evidence: Level I, prospective randomized trial.


Orthopedics | 2015

Total Ankle Arthroplasty With Severe Preoperative Varus Deformity

Andrew E. Hanselman; Brian D Powell; Robert D. Santrock

Advancements in total ankle arthroplasty (TAA) over the past several decades have led to improved patient outcomes and implant survivorship. Despite these innovations, many implant manufacturers still consider a preoperative coronal plane deformity greater than 10° a relative contraindication to TAA. Without proper intraoperative alignment, these implants may experience abnormal wear and hardware failure. Correcting these deformities, often through the use of soft tissue procedures and/or osteotomies, not only increases the difficulty of a case, but also the intraoperative time and radiation exposure. The authors report a case in which a 54-year-old man with a severe right ankle varus deformity of 29° underwent successful TAA using the INBONE II Prophecy total ankle system (Wright Medical Technology, Inc, Memphis, Tennessee) and additional soft tissue reconstruction. Intraoperatively, the patients coronal deformity was corrected to 1.8°. At 8 months postoperatively, the patient ambulated without restriction and had substantial improvement in validated patient outcome scores, specifically the Academy of Orthopaedic Surgeons Foot and Ankle Module and the Short Form Health Survey-12 This unique report documents the first time that this particular implant, with an exclusive preoperative computed tomography-derived patient-specific guide, has been used effectively for a severe preoperative varus deformity greater than 20° without the need for an osteotomy. Future studies should be directed toward the prospective evaluation of different total ankle implant systems and their outcomes with severe coronal plane deformity, specifically computed tomography-derived patient-specific guided implants.


Foot and Ankle Specialist | 2015

Topical Review Use of Fetal Tissue in Foot and Ankle Surgery

Andrew E. Hanselman; Trapper Lalli; Robert D. Santrock

Fetal tissues are well known for their therapeutic potential. They contain numerous growth factors, cytokines, and matrix components that promote regeneration of tissues while downregulating inflammation and scar formation. As a result, use of these treatments has expanded over the previous 20 years throughout various surgical specialties, including orthopaedics. With improved methods of sterilization, processing, and storage, surgeons need to be informed about the potential benefits of fetal tissue in foot and ankle surgery. The aim of this review is to provide a brief historical background, basic anatomy and physiology, and a current review of the literature in regard to chronic wounds, diabetic foot ulcerations, plantar fasciitis, tendon repair, adhesion prevention, nerve repair, and bone healing. Levels of Evidence: Level V: Expert Opinion


Knee | 2017

Smartphone assessment of knee flexion compared to radiographic standards

Matthew J. Dietz; Daniel Sprando; Andrew E. Hanselman; Michael Regier; Benjamin M. Frye

BACKGROUND Measuring knee range of motion (ROM) is an important assessment for the outcomes of total knee arthroplasty. Recent technological advances have led to the development and use of accelerometer-based smartphone applications to measure knee ROM. The purpose of this study was to develop, standardize, and validate methods of utilizing smartphone accelerometer technology compared to radiographic standards, visual estimation, and goniometric evaluation. METHODS Participants used visual estimation, a long-arm goniometer, and a smartphone accelerometer to determine range of motion of a cadaveric lower extremity; these results were compared to radiographs taken at the same angles. RESULTS The optimal smartphone position was determined to be on top of the leg at the distal femur and proximal tibia location. Between methods, it was found that the smartphone and goniometer were comparably reliable in measuring knee flexion (ICC=0.94; 95% CI: 0.91-0.96). Visual estimation was found to be the least reliable method of measurement. CONCLUSIONS The results suggested that the smartphone accelerometer was non-inferior when compared to the other measurement techniques, demonstrated similar deviations from radiographic standards, and did not appear to be influenced by the person performing the measurements or the girth of the extremity.


Foot & Ankle International | 2014

Effect of Dorsal Plate Positioning on Dorsiflexion Angle in Arthrodesis of the First Metatarsophalangeal Joint A Cadaveric Study

Jesse T. Lewis; Andrew E. Hanselman; Trapper Lalli; Justin L. Daigre; Robert D. Santrock

Background: The relationship between dorsal plate positioning and final dorsiflexion angle after first metatarsophalangeal (MTP) joint fusion has not been well established. The main purpose of this study was to investigate whether changes in dorsal plate positioning along the longitudinal axis affect fusion dorsiflexion angle, as excessive dorsiflexion angles can lead to poor clinical results. Methods: Ten cadaver foot specimens were randomly assigned to 2 groups for first MTP joint fusion: 1 group used a straight plate, and the other group used a 10-degree precontoured plate. After routine preparation, the plates were placed in an “ideal” position based on clinical and radiological examination. The plates were then moved proximally 3 mm and 6 mm from the initial site, with repeat imaging completed at each position. The radiological dorsiflexion angle was determined for each position, and the results were assessed. Results: Placement of both straight and precontoured plates at positions more proximal from the initial position led to significant increases in dorsiflexion angles (P = .04), although the percentage change was larger in the precontoured plate group (P = .01). While placement of the plate 3 mm proximal from the perceived “ideal” position did increase the dorsiflexion angle, the percentage of specimens with dorsiflexion angles in the suggested optimal range changed minimally. Positioning at 6 mm from the starting point, however, led to significantly increased dorsiflexion angles for both plates (P = .004). Conclusion: Positioning the dorsal plate at more proximal locations leads to increasing dorsiflexion angles. Precontoured plates are more likely to lead to excessive dorsiflexion compared with straight plates regardless of plate position. Clinical Relevance: Fusion at excessive dorsiflexion angles can be minimized with appropriate selection and proper positioning of the dorsal fusion plate along the longitudinal axis.


Orthopedics | 2016

Operative Cost Comparison: Plating Versus Intramedullary Fixation for Clavicle Fractures

Andrew E. Hanselman; Timothy R. Murphy; George K. Bal; E Barry McDonough

Although clavicle fractures often heal well with nonoperative management, current literature has shown improved outcomes with operative intervention for specific fracture patterns in specific patient types. The 2 most common methods of midshaft clavicle fracture fixation are intramedullary and plate devices. Through retrospective analysis, this study performed a direct cost comparison of these 2 types of fixation at a single institution over a 5-year period. Outcome measures included operative costs for initial surgery and any hardware removal surgeries. This study reviewed 154 patients (157 fractures), and of these, 99 had intramedullary fixation and 58 had plate fixation. A total of 80% (79 of 99) of intramedullary devices and 3% (2 of 58) of plates were removed. Average cost for initial intramedullary placement was


Advances in orthopedics | 2018

Osseointegrated Transcutaneous Device for Amputees: A Pilot Large Animal Model

Brian T. Grisez; Andrew E. Hanselman; Karim W. Boukhemis; Trapper Lalli; Brock A. Lindsey

2955 (US dollars) less than that for initial plate placement (P<.001); average cost for removal was


Foot and Ankle Specialist | 2017

Posterior Tibialis Tendon Rupture in a Closed Bimalleolar-Equivalent Ankle Fracture: Case Report

Richard M. Wardell; Andrew E. Hanselman; Scott D. Daffner; Robert D. Santrock

1874 less than that for plate removal surgery (P=.2). Average total cost for all intramedullary surgeries was


Clinics in Podiatric Medicine and Surgery | 2017

Acute Rupture Open Repair Techniques

Robert D. Santrock; Andrew J. Friedmann; Andrew E. Hanselman

1392 less than the average cost for all plating surgeries (P<.001). Average cost for all intramedullary surgeries requiring plate placement and removal was


The Foot | 2015

Economic impact of syndesmosis hardware removal

Trapper Lalli; Leslie J Matthews; Andrew E. Hanselman; David F. Hubbard; Michelle A. Bramer; Robert D. Santrock

653 less than the average cost for all plating surgeries that involved only placement (P=.04). Intramedullary fixation of clavicle fractures resulted in a statistically significant cost reduction compared with plate fixation, despite the incidence of more frequent removal surgeries. [Orthopedics.2016; 39(5):e877-e882.].

Collaboration


Dive into the Andrew E. Hanselman's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Trapper Lalli

West Virginia University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge