Featured researches published by Andrew Kuhls-Gilcrist.


Physics in Medicine and Biology | 2008

A practical exposure-equivalent metric for instrumentation noise in x-ray imaging systems

G Yadava; Andrew Kuhls-Gilcrist; Stephen Rudin; V Patel; K Hoffmann; Daniel R. Bednarek

The performance of high-sensitivity x-ray imagers may be limited by additive instrumentation noise rather than by quantum noise when operated at the low exposure rates used in fluoroscopic procedures. The equipment-invasive instrumentation noise measures (in terms of electrons) are generally difficult to make and are potentially not as helpful in clinical practice as would be a direct radiological representation of such noise that may be determined in the field. In this work, we define a clinically relevant representation for instrumentation noise in terms of noise-equivalent detector entrance exposure, termed the instrumentation noise-equivalent exposure (INEE), which can be determined through experimental measurements of noise-variance or signal-to-noise ratio (SNR). The INEE was measured for various detectors, thus demonstrating its usefulness in terms of providing information about the effective operating range of the various detectors. A simulation study is presented to demonstrate the robustness of this metric against post-processing, and its dependence on inherent detector blur. These studies suggest that the INEE may be a practical gauge to determine and compare the range of quantum-limited performance for clinical x-ray detectors of different design, with the implication that detector performance at exposures below the INEE will be instrumentation-noise limited rather than quantum-noise limited.


Proceedings of SPIE--the International Society for Optical Engineering | 2008

The Solid-State X-Ray Image Intensifier (SSXII): An EMCCD- Based X-Ray Detector

Andrew Kuhls-Gilcrist; G Yadava; V Patel; Amit Jain; Daniel R. Bednarek; Stephen Rudin

The solid-state x-ray image intensifier (SSXII) is an EMCCD-based x-ray detector designed to satisfy an increasing need for high-resolution real-time images, while offering significant improvements over current flat panel detectors (FPDs) and x-ray image intensifiers (XIIs). FPDs are replacing XIIs because they reduce/eliminate veiling glare, pincushion or s-shaped distortions and are physically flat. However, FPDs suffer from excessive lag and ghosting and their performance has been disappointing for low-exposure-per-frame procedures due to excessive instrumentation-noise. XIIs and FPDs both have limited resolution capabilities of ~3 cycles/mm. To overcome these limitations a prototype SSXII module has been developed, consisting of a 1k x 1k, 8 μm pixel EMCCD with a fiber-optic input window, which views a 350 μm thick CsI(Tl) phosphor via a 4:1 magnifying fiber-optic-taper (FOT). Arrays of such modules will provide a larger field-of- view. Detector MTF, DQE, and instrumentation-noise equivalent exposure (INEE) were measured to evaluate the SSXIIs performance using a standard x-ray spectrum (IEC RQA5), allowing for comparison with current state-of-the-art detectors. The MTF was 0.20 at 3 cycles/mm, comparable to standard detectors, and better than 0.05 up to 7 cycles/mm, well beyond current capabilities. DQE curves indicate no degradation from high-angiographic to low-fluoroscopic exposures (< 2% deviation in overall DQE from 1.3 mR to 2.7 μR), demonstrating negligible instrumentation-noise, even with low input signal intensities. An INEE of < 0.2 μR was measured for the highest-resolution mode (32 μm effective pixel size). Comparison images between detector technologies qualitatively demonstrate these improved imaging capabilities provided by the SSXII.


Proceedings of SPIE | 2009

Component analysis of a new Solid State X-ray Image Intensifier (SSXII) using photon transfer and Instrumentation Noise Equivalent Exposure (INEE) measurements

Andrew Kuhls-Gilcrist; Daniel R. Bednarek; Stephen Rudin

The SSXII is a novel x-ray imager designed to improve upon the performance limitations of conventional dynamic radiographic/fluoroscopic imagers related to resolution, charge-trapping, frame-rate, and instrumentation-noise. The SSXII consists of a CsI:Tl phosphor coupled via a fiber-optic taper (FOT) to an electron-multiplying CCD (EMCCD). To facilitate investigational studies, initial designs enable interchangeability of such imaging components. Measurements of various component and configuration characteristics enable an optimization analysis with respect to overall detector performance. Photon transfer was used to characterize the EMCCD performance including ADC sensitivity, read-noise, full-well capacity and quantum efficiency. X-ray sensitivity was measured using RQA x-ray spectra. Imaging components were analyzed in terms of their MTF and transmission efficiency. The EMCCD was measured to have a very low effective read-noise of less than 1 electron rms at modest EMCCD gains, which is more than two orders-ofmagnitude less than flat panel (FPD) and CMOS-based detectors. The variable signal amplification from 1 to 2000 times enables selectable sensitivities ranging from 8.5 (168) to over 15k (300k) electrons per incident x-ray photon with (without) a 4:1 FOT; these sensitivities could be readily increased with further component optimization. MTF and DQE measurements indicate the SSXII performance is comparable to current state-of-the-art detectors at low spatial frequencies and far exceeds them at higher spatial frequencies. The instrumentation noise equivalent exposure (INEE) was measured to be less than 0.3 μR out to 10 cycles/mm, which is substantially better than FPDs. Component analysis suggests that these improvements can be substantially increased with further detector optimization.


Proceedings of SPIE--the International Society for Optical Engineering | 2008

Generalized objective performance assessment of a new high-sensitivity microangiographic fluoroscopic (HSMAF) imaging system

G Yadava; Stephen Rudin; Andrew Kuhls-Gilcrist; Daniel R. Bednarek

The objective performance evaluation metrics, termed Generalized Modulation Transfer Function (GMTF), Generalized Noise Power Spectrum (GNPS), Generalized Noise Equivalent Quanta (GNEQ), and Generalized Detective Quantum Efficiency (GDQE), have been developed to assess total imaging-system performance by including the effects of geometric unsharpness due to the finite size of the focal spot and scattered radiation in addition to the detector properties. These metrics were used to evaluate the performance of the HSMAF, a custom-built, high-resolution, real-time-acquisition detector with 35-μm pixels, in simulated neurovascular angiographic conditions using a uniform head-equivalent phantom. The HSMAF consists of a 300-μm-thick CsI(Tl) scintillator coupled to a 4 cm diameter, variable-gain, Gen2 light image intensifier with dual-stage microchannel plate, followed by direct fiber-optic coupling to a 30-fps CCD camera, and is capable of both fluoroscopy and angiography. Effects of focal-spot size, geometric magnification, irradiation field-of-view, and air-gap between the phantom and the detector were evaluated. The resulting plots of GMTF and GDQE showed that geometric blurring is the more dominant image degradation factor at high spatial frequencies, whereas scatter dominates at low spatial frequencies. For the standard image-geometry and scatter conditions used here, the HSMAF maintains substantial system imaging capabilities (GDQE>5%) at frequencies above 4 cycles/mm where conventional detectors cannot operate. The loss in image SNR due to scatter or focal-spot unsharpness could be compensated by increasing the exposure by a factor of 2 to 3. This generalized evaluation method may be used to more realistically evaluate and compare total system performance leading to improved system designs.


Proceedings of SPIE | 2010

Generalized two-dimensional (2D) linear system analysis metrics (GMTF, GDQE) for digital radiography systems including the effect of focal spot, magnification, scatter, and detector characteristics

Amit Jain; Andrew Kuhls-Gilcrist; Sandesh K. Gupta; Daniel R. Bednarek; Stephen Rudin

The MTF, NNPS, and DQE are standard linear system metrics used to characterize intrinsic detector performance. To evaluate total system performance for actual clinical conditions, generalized linear system metrics (GMTF, GNNPS and GDQE) that include the effect of the focal spot distribution, scattered radiation, and geometric unsharpness are more meaningful and appropriate. In this study, a two-dimensional (2D) generalized linear system analysis was carried out for a standard flat panel detector (FPD) (194-micron pixel pitch and 600-micron thick CsI) and a newly-developed, high-resolution, micro-angiographic fluoroscope (MAF) (35-micron pixel pitch and 300- micron thick CsI). Realistic clinical parameters and x-ray spectra were used. The 2D detector MTFs were calculated using the new Noise Response method and slanted edge method and 2D focal spot distribution measurements were done using a pin-hole assembly. The scatter fraction, generated for a uniform head equivalent phantom, was measured and the scatter MTF was simulated with a theoretical model. Different magnifications and scatter fractions were used to estimate the 2D GMTF, GNNPS and GDQE for both detectors. Results show spatial non-isotropy for the 2D generalized metrics which provide a quantitative description of the performance of the complete imaging system for both detectors. This generalized analysis demonstrated that the MAF and FPD have similar capabilities at lower spatial frequencies, but that the MAF has superior performance over the FPD at higher frequencies even when considering focal spot blurring and scatter. This 2D generalized performance analysis is a valuable tool to evaluate total system capabilities and to enable optimized design for specific imaging tasks.


ieee nuclear science symposium | 2009

Improved contrast and spatial resolution with single photon counting (SPC) for an area X-ray imager, the newly developed high-resolution Micro-Angiographic Fluoroscopic (MAF) detector

Amit Jain; Andrew Kuhls-Gilcrist; Daniel R. Bednarek; Stephen Rudin

Although in radiological imaging, the prevailing mode of acquisition is the integration of the energy deposited by all x-rays absorbed in the imaging detector, much improvement in image spatial and contrast resolution could be achieved if each individual x-ray photon were detected and counted separately. In this work we compare the conventional energy integration (EI) mode with the new single photon counting (SPC) mode for a recently developed high-resolution Micro-Angiographic Fluoroscopic (MAF) detector, which is uniquely capable of both modes of operation. The MAF has 1024×1024 pixels of 35 microns effective size and is capable of real-time imaging at 30 fps. The large variable gain of its light image intensifier (LII) provides quantum limited operation with essentially no additive instrumentation noise and enables the MAF to operate in both EI and the very sensitive low-exposure SPC modes. We used high LII gain with very low exposure (<1 x-ray photon/pixel) per frame for SPC mode and higher exposure per frame with lower gain for EI mode. Multiple signal-thresholded frames were summed in SPC mode to provide an integrated frame with the same total exposure as EI mode. A heavily K-edge filtered x-ray beam (average energy of 31 keV) was used to provide a nearly monochromatic spectrum. The MTF measured using a standard slit method showed a dramatic improvement for the SPC mode over the EI mode at all frequencies. Images of a line pair phantom also showed improved spatial resolution with 12 lp/mm visible in SPC mode compared to only 8 lp/mm in EI mode. In SPC mode, images of human distal and middle phalanges showed the trabecular structures of the bone with far better contrast and detail. These improvements with the SPC mode should be advantageous for clinical applications where high resolution and/or high contrast are essential such as in mammography and extremity imaging as well as for dual modality applications, which combine nuclear medicine and x-ray imaging using a single detector.


ieee nuclear science symposium | 2010

Quantum performance analysis of an EMCCD-based x-ray detector using photon transfer technique

Bin Qu; Andrew Kuhls-Gilcrist; Ying Huang; Weiyuan Wang; Alexander N. Cartwright; Albert H. Titus; Daniel R. Bednarek; Stephen Rudin

The low electronic noise, high resolution, and good temporal performance of electron-multiplying CCDs (EMCCDs) are ideally suited for applications traditionally served by x-ray image intensifiers. In order to improve an expandable clinical detectors field-of-view and have full control of the system performance, we have successfully built a solid-state x-ray detector. The photon transfer technique was used to quantify the EMCCD quantum performance in terms of sensitivity (or camera gain constant, K), read noise (RN), full-well capacity (FW), and dynamic range (DR). Measured results show the system maintains a K of 11.3 ± 0.9 e−/DN at unit gain, with a read noise of 71.5±6.0 e− rms at gain 1, which decreases proportionally with higher gains. The full well capacity was measured to be 31.3±2.7 ke−, providing a dynamic range of 52.8±0.7 dB using the chip manufacturer specified clocking scheme. Similar performance was measured with other commercial camera systems. The manufacturer data sheet indicates a dynamic range of 66 dB is plausible with improved read noise and full well capacity. Different clocking schemes are under investigation to assess their impact on improving performance towards idealized values. EMCCD driver clock voltage levels were adjusted individually to check the influence on quantum performance. The clocks work to transfer charge from the image area to readout amplifier through the storage area, horizontal and multiplication registers. Results indicate that the clock that contributes to lateral overflow drain bias is essential to the system performance in terms of dynamic range and full well capacity. The serial register clocks used for transporting charge stored in the pixels of the memory lines to the output amplifier had the largest effect on RN, while others had less of an impact. Initial adjustment of these clocks resulted in a variability of 16% in the performance of dynamic range, 38% in read noise and 56% in full well capacity. Quantifying the quantum performance provides valuable insight into overall performance and enables optimal adjustment of the clocking scheme. Further improvements are expected.


Proceedings of SPIE | 2010

The solid state x-ray image intensifier (SSXII) in single photon counting (SPC) mode

Andrew Kuhls-Gilcrist; Amit Jain; Daniel R. Bednarek; Stephen Rudin

The new Solid State X-Ray Image Intensifier (SSXII) has the unique ability to operate in single photon counting (SPC) mode, with improved resolution, as well as in traditional energy integrating (EI) mode. The SSXII utilizes an electron-multiplying CCD (EMCCD), with an effective pixel size of 32μm, which enables variable signal amplification (up to a factor of 2000) prior to digital readout, providing very high-sensitivity capabilities. The presampled MTF was measured in both imaging modes using the standard angulated-slit method. A measured detector entrance exposure of 24μR per frame was used to provide approximately 0.8 interaction events per pixel in the 10μm-wide slit area. For demonstration purposes, a simple thresholding technique was used to localize events in SPC mode and a number of such frames were summed to provide an image with the same total exposure used for acquiring the EI image. The MTF for SPC mode, using a threshold level of 15% of the maximum 12-bit signal and 95% of the expected events, and for EI mode (in parentheses) was 0.67 (0.20), 0.37 (0.07), 0.20 (0.03), and 0.11 (0.01) at 2.5, 5, 7.5, and 10 cycles/mm, respectively. Increasing the threshold level resulted in a corresponding increase in the measured SPC MTF and a lower number of detected events, indicating a tradeoff between resolution and count efficiency is required. The SSXII in SPC mode was shown to provide substantial improvements in resolution relative to traditional EI mode, which should benefit applications that have demanding spatial resolution requirements, such as mammography.


Proceedings of SPIE | 2011

Graphical user interface for a dual-module EMCCD x-ray detector array

Weiyuan Wang; Ciprian N. Ionita; Andrew Kuhls-Gilcrist; Ying Huang; Bin Qu; Sandesh K. Gupta; Daniel R. Bednarek; Stephen Rudin

A new Graphical User Interface (GUI) was developed using Laboratory Virtual Instrumentation Engineering Workbench (LabVIEW) for a high-resolution, high-sensitivity Solid State X-ray Image Intensifier (SSXII), which is a new x-ray detector for radiographic and fluoroscopic imaging, consisting of an array of Electron-Multiplying CCDs (EMCCDs) each having a variable on-chip electron-multiplication gain of up to 2000x to reduce the effect of readout noise. To enlarge the field-of-view (FOV), each EMCCD sensor is coupled to an x-ray phosphor through a fiberoptic taper. Two EMCCD camera modules are used in our prototype to form a computer-controlled array; however, larger arrays are under development. The new GUI provides patient registration, EMCCD module control, image acquisition, and patient image review. Images from the array are stitched into a 2kx1k pixel image that can be acquired and saved at a rate of 17 Hz (faster with pixel binning). When reviewing the patients data, the operator can select images from the patients directory tree listed by the GUI and cycle through the images using a slider bar. Commonly used camera parameters including exposure time, trigger mode, and individual EMCCD gain can be easily adjusted using the GUI. The GUI is designed to accommodate expansion of the EMCCD array to even larger FOVs with more modules. The high-resolution, high-sensitivity EMCCD modular-array SSXII imager with the new user-friendly GUI should enable angiographers and interventionalists to visualize smaller vessels and endovascular devices, helping them to make more accurate diagnoses and to perform more precise image-guided interventions.


ieee nuclear science symposium | 2010

Optical demonstration of a medical imaging system with an EMCCD-sensor array for use in a high resolution dynamic X-ray imager

Bin Qu; Ying Huang; Weiyuan Wang; P. Sharma; Andrew Kuhls-Gilcrist; Alexander N. Cartwright; Albert H. Titus; Daniel R. Bednarek; Stephen Rudin

Use of an extensible array of Electron Multiplying CCDs (EMCCDs) in medical x-ray imager applications was demonstrated for the first time. The large variable electronic-gain (up to 2000) and small pixel size of EMCCDs provide effective suppression of readout noise compared to signal, as well as high resolution, enabling the development of an x-ray detector with far superior performance compared to conventional x-ray image intensifiers and flat panel detectors. We are developing arrays of EMCCDs to overcome their limited field of view (FOV). In this work we report on an array of two EMCCD sensors running simultaneously at a high frame rate and optically focused on a mammogram film showing calcified ducts. The work was conducted on an optical table with a pulsed LED bar used to provide a uniform diffuse light onto the film to simulate x-ray projection images. The system can be selected to run at up to 17.5 frames per second or even higher frame rate with binning. Integration time for the sensors can be adjusted from 1 ms to 1000 ms. Twelve-bit correlated double sampling AD converters were used to digitize the images, which were acquired by a National Instruments dual-channel Camera Link PC board in real time. A user-friendly interface was programmed using LabVIEW to save and display 2K × 1K pixel matrix digital images. The demonstration tiles a 2 × 1 array to acquire increased-FOV stationary images taken at different gains and fluoroscopic-like videos recorded by scanning the mammogram simultaneously with both sensors. The results show high resolution and high dynamic range images stitched together with minimal adjustments needed. The EMCCD array design allows for expansion to an M×N array for arbitrarily larger FOV, yet with high resolution and large dynamic range maintained.

Collaboration


Dive into the Andrew Kuhls-Gilcrist's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

S Rudin

University at Buffalo

View shared research outputs
Top Co-Authors

Avatar

Amit Jain

University at Buffalo

View shared research outputs
Top Co-Authors

Avatar

A Jain

University at Buffalo

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

K Hoffmann

State University of New York System

View shared research outputs
Top Co-Authors

Avatar

Bin Qu

University at Buffalo

View shared research outputs
Researchain Logo
Decentralizing Knowledge