Publication


Featured researches published by Andrew Maitland.


American Journal of Cardiology | 1993

Comparison of biphasic and monophasic shocks for defibrillation using a nonthoracotomy system

D. George Wyse; Katherine M. Kavanagh; Anne M. Gillis; L. Brent Mitchell; Henry J. Duff; Robert S. Sheldon; Teresa M. Kieser; Andrew Maitland; Patricia Flanagan; John M. Rothschild; Rahul Mehra

A comparison of defibrillation thresholds was made using biphasic and monophasic shocks delivered by a nonthoracotomy lead system in 2 clinically distinct groups of patients. The first group were patients receiving an implantable cardioverter-defibrillator who were studied before surgery with their chests closed. The second group were patients undergoing coronary artery bypass grafting (CABG) who were studied before surgery with their chests open but reapproximated. Biphasic defibrillation thresholds (stored energy) were significantly (p < 0.001) less than monophasic ones in subjects with the implantable cardioverter-defibrillator (12.3 +/- 5.3 vs 21.1 +/- 9.3 J) or CABG (14.6 +/- 7.1 vs 24.2 +/- 12.6 J). These values are less than were previously reported with a similar nonthoracotomy lead configuration. There were no significant differences between the 2 groups in all measurements derived from corresponding shock waveforms, although impedance tended to be greater in patients with CABG. However, subjects with CABG had greater left ventricular ejection fractions and did not have history of potentially lethal ventricular arrhythmias. Despite these differences, the conclusion that biphasic shocks are more effective would have been made in a study of either group alone. It is concluded that patients with CABG who have not had preceding potentially lethal ventricular arrhythmias may be a potential source of surrogate subjects for defibrillation research such as epicardial mapping, which requires that the chest be open.


The Annals of Thoracic Surgery | 2002

The intraaortic balloon pump in cardiac surgery

Roger J.F. Baskett; William A. Ghali; Andrew Maitland; Gregory M. Hirsch

The intraaortic balloon pump (IABP) has been used in cardiac operations since the late 1960s. Over the years, with refinements in technology, its use has expanded; the IABP is now the most commonly used mechanical assist device in cardiac operative procedures. This review provides an evaluation of evidence for the efficacy of IABP use in different clinical scenarios, using the American College of Cardiology/American Heart Association classification of evidence where appropriate. We evaluated complications and outcomes associated with IABP use, and attempted to draw conclusions regarding the use of the IABP in different clinical situations. We examined the trends and variation in utilization over time and across centers. We discussed the IABP in light of new cardiac assist devices and the changing patient population and management strategies. Lastly, we identified areas of future research.


Canadian Medical Association Journal | 2005

Outcomes in octogenarians undergoing coronary artery bypass grafting

Roger J.F. Baskett; Karen J. Buth; William A. Ghali; Colleen M. Norris; Tony Maas; Andrew Maitland; David B. Ross; Rand Forgie; Gregory M. Hirsch

Background: Although octogenarians are being referred for coronary artery bypass grafting (CABG) with increasing frequency, contemporary outcomes have not been well described. We examined data from 4 Canadian centres to determine outcomes of CABG in this age group. Methods: Data for the years 1996 to 2001 were examined in a comparison of octogenarians with patients less than 80 years of age. Logistic regression analysis was used to adjust for preoperative factors and to generate adjusted rates of mortality and postoperative stroke. Results: A total of 15 070 consecutive patients underwent isolated CABG during the study period. Overall, 725 (4.8%) were 80 years of age or older, the proportion increasing from 3.8% in 1996 to 6.2% in 2001 (p for linear trend = 0.03). The crude rate of death was higher among the octogenarians (9.2% v. 3.8%; p < 0.001), as was the rate of stroke (4.7% v. 1.6%, p < 0.001). The octogenarians had a significantly greater burden of comorbid conditions and more urgent presentation at surgery. After adjustment, the octogenarians remained at greater risk for in-hospital death (odds ratio [OR] 2.64, 95% confidence interval [CI] 1.95–3.57) and stroke (OR 3.25, 95% CI 2.15–4.93). Mortality declined over time for both age groups (p for linear trend < 0.001 for both groups), but the incidence of postoperative stroke did not change (p for linear trend = 0.61 [age < 80 years] and 0.08 [age ≥ 80 years]). Octogenarians who underwent elective surgery had crude and adjusted rates of death (OR 1.31, 95% CI 0.60–2.90) and stroke (OR 1.59, 95% CI 0.57–4.44) that were higher than but not significantly different from those for non-octogenarians who underwent elective surgery. Interpretation: In this study, rates of death and stroke were higher among octogenarians, although the adjusted differences in mortality over time were decreasing. The rate of adverse outcomes in association with elective surgery was similar for older and younger patients.


Cardiovascular Research | 2001

Endothelin receptor blockade improves endothelial function in human internal mammary arteries

Subodh Verma; Fina Lovren; Aaron S. Dumont; Kieren J. Mather; Andrew Maitland; Teresa M. Kieser; William T. Kidd; John H. McNeill; Duncan J. Stewart; Chris R. Triggle; Todd J. Anderson

OBJECTIVE Endothelial dysfunction, specifically endothelium-derived contracting factors have been implicated in the development of arterial conduit vasospasm. The potent vasoconstrictor endothelin-1 (ET-1) has received much attention in this regard. The present study was designed to evaluate the role of ET-1 in the development of endothelial dysfunction in human internal mammary arteries (IMA). To this aim, we examined the effects of specific and non-specific ET-receptor antagonists on endothelial function (assessed using acetylcholine (ACh)-induced vasodilation) in segments of IMA obtained during coronary artery bypass graft (CABG) surgery. METHODS Vascular segments of IMA were obtained from 51 patients undergoing elective coronary artery bypass graft (CABG) surgery and in vitro endothelium-dependent and -independent responses to ACh and sodium nitroprusside (SNP) were assessed. Isometric dose response curves (DRC) to ACh and SNP were constructed in pre-contracted rings in the presence and absence of bosentan (ET(A/B) receptor antagonist, 3 microM), BQ-123 (ET(A) antagonist, 1 microM) and BQ-788 (ET(B) antagonist, 1 microM) using the isolated organ bath apparatus. Percent maximum relaxation (%E(max)) and sensitivity (pEC(50)) were compared between interventions. RESULTS ACh caused dose-dependent endothelium-mediated relaxation in IMA (%E(max) 43+/-4, pEC(50) 6. 74+/-0.12). In the presence of bosentan, BQ-123 and BQ-788 ACh-induced relaxation was significantly augmented (%E(max) bosentan 60+/-3, BQ-123 56+/-4, BQ-788 53+/-5 vs. control 43+/-4, P<0.05) without affecting sensitivity. The effects of these antagonists were endothelium-specific since endothelium-independent responses to SNP remained unaltered. Furthermore, the beneficial effects were independently and maximally mediated by ET(A) and ET(B) receptors (%E(max) BQ-123 56+/-4 vs. BQ-788 53+/-5 vs. bosentan 60+/-3, P>0. 05). CONCLUSIONS These data uncover, for the first time, beneficial effects of ET receptor blockade on endothelial-dependent vasorelaxation in human IMA.


Molecular and Cellular Biochemistry | 2003

Tetrahydrobiopterin attenuates homocysteine induced endothelial dysfunction.

Bikramjit Dhillon; Mitesh Badiwala; Andrew Maitland; Rao; Shu-Hong Li; Subodh Verma

Homocysteine is an independent risk factor for atherosclerotic vascular disease. It impairs endothelial function via increasing superoxide production and quenching nitric oxide (NO) release. Tetrahydrobiopterin (BH4) is a critical cofactor that couples nitric oxide synthase and facilitates the production of nitric oxide (vs. superoxide anions). In the first study, the effects of hyperhomocysteinemia (0.1 mM, 3 h) on endothelium-dependent vasorelaxation to ACh and A23187 were examined in isolated segments of rat aortae in the presence or absence of BH4 (0.1 mM). In the second study, the effects of hyperhomocysteinemia (24 h) on nitric oxide production and superoxide release (using lucigenin chemiluminescence) were studied in human umbilical vein endothelial cells in the absence or presence of BH4 (10 μM). Homocysteine incubation impaired receptor-dependent and -independent endothelial function to ACh and A23187. This effect was attenuated by BH4. Furthermore, homocysteine exposure increased superoxide production and impaired agonist-stimulated nitric oxide release. These effects were attenuated by BH4 (p < 0.05). Hyperhomocysteinemia impairs endothelial function, in part due to a diminished bioavailability of BH4 with resultant uncoupling of nitric oxide synthase. BH4 may represent an important target for strategies aimed at improving endothelial dysfunction secondary to hyperhomocysteinemia.


Pacing and Clinical Electrophysiology | 1993

A randomized comparison of a bipolar steroid-eluting electrode and a bipolar microporous platinum electrode: implications for long-term programming.

Anne M. Gillis; John M. Rothschild; Karen R. Hillier; Wilma Fudge; Teresa M. Kieser; Andrew Maitland

Differences in acute and chronic pacing thresholds were compared in patients receiving either the Medtronic Model 4004 steroid‐eluting lead or the Medtronic Model 4012 microporous platinum lead. Patients (n = 35) were randomized at the time of implant to receive either a steroid‐eluting (n = 17) or a microporous (n = 18) lead. Pacing thresholds were determined within 24 hours and at 2, 4, 6, 12. 24, and 52 weeks postimplant. By 2 weeks postimplant. pacing thresholds measured at 0.8, 1.6, 2.5, 3.3, and 4.2 V were significantly lower in the steroid lead group compared to the microporous Jead group (P < 0.05). At 24 weeks, the voltage threshold at 0.3 msec was 0.8 V in 88% of patients with a steroid lead whereas this threshold was only observed in 33% of patients with the microporous lead (P < 0.01). At 52 weeks the pacing energy measured at 1.6 V, twice pulse duration threshold, was significantly lower in the steroid lead group (0.81 ± 0.59 μJ) compared to the microporous lead group (1.25 ± 0.60 μJ, P < 0.05). Thirteen patients in the steroid lead group and 9 patients in the microporous lead group have been programmed at a pulse amplitude of 1.6 V since the 24‐week follow‐up visit. These patients have been followed for a minimum of 6 months without documented failure to capture. This study shows that pacemaker/lead systems with stable chronic low thresholds can be safely programmed to low pulse amplitude settings. This practice will prolong the longevity of pulse generators.


The Annals of Thoracic Surgery | 2003

A multicenter comparison of intraaortic balloon pump utilization in isolated coronary artery bypass graft surgery

Roger Baskett; Gerald T. O'Connor; Gregory M. Hirsch; William A. Ghali; Kathy Sabadosa; Jeremy R. Morton; Cathy S. Ross; Felix Hernandez; William C. Nugent; Stephen J. Lahey; Donato Sisto; Lawrence J. Dacey; John D. Klemperer; Robert E. Helm; Andrew Maitland

BACKGROUND Single-center studies suggest substantial variation in intraaortic balloon pump (IABP) utilization. Our purpose is to examine IABP utilization over time and across medical centers. METHODS This was a prospective cohort of 29,961 consecutive patients undergoing isolated coronary artery bypass graft surgery, between 1995 and 2000, at 10 centers (eight in northern New England and two in Canada). RESULTS A total of 2,678 (8.9%) patients received an IABP. The rate of preoperative IABP insertion was 6.3%, and that of intra- or postoperative insertion was 2.6%. During the 6 years, IABP use increased from 7.0% to 10.3% (p(trend) <0.001). Preoperative IABP insertion increased from 5.4% to 7.8% (p(trend) < 0.001). There was no significant increase in intra-/postoperative IABP insertion 1.7% to 3.4% (p(trend) = 0.34). Adjustment for changes in patient and disease characteristics did not substantially alter these results. The rate of IABP use varied substantially by center, from 5.9% to 16.4% (p < 0.001). Adjustment for patient and disease characteristics resulted in variation from 4.8% to 12.8% across the 10 centers (p < 0.001). The adjusted rates of preoperative IABP insertion varied from 3.6% to 13.7% (p < 0.001), and the rates of intra-/postoperative IABP insertion ranged from 1.0% to 5.2% (p < 0.001). There was no significant correlation between the rates of preoperative and intra-/postoperative IABP use (r(s) = 0.085, p = 0.815). CONCLUSIONS During the 6 years, there was a 47% increase in the rate of IABP utilization. Even after adjustment, there was almost threefold variation in IABP use across centers. This variation likely reflects lack of consensus on the appropriate use of the IABP in CABG patients.


The Annals of Thoracic Surgery | 2001

Medtronic mosaic porcine bioprosthesis: midterm investigational trial results

Dorothy Thomson; W.R. Eric Jamieson; Jean G. Dumesnil; John J Burgess; Charles Peniston; Jacques Métras; John A Sullivan; James C.W. Parrott; Andrew Maitland; Irene J. Cybulsky

BACKGROUND The midterm clinical and hemodynamic performance of the Medtronic Mosaic porcine bioprosthesis was evaluated in a regulatory trial. METHODS In nine Canadian centers, 802 bioprostheses (560 aortic and 242 mitral) were implanted between September 1994 and April 1999 in patients with a mean age of 70 years. RESULTS Survival for aortic valve replacement at 4 years was 84.4%+/-3.1%. Freedom from valve-related or unexplained death was 95.6%+/-1.9%; structural valve deterioration, 100.0%; reoperation, 96.2%+/-1.7%; major thromboembolism, 96.1%+/-1.8%; and major antithrombotic-related hemorrhage, 96.4%+/-1.7%. Echocardiographic derived mean systolic gradient was 13.4 mm Hg at 4 years with an indexed effective orifice area of 0.7 to 0.8 cm2/m2. A significant decrease in left ventricular mass was shown over time in all valve sizes. Survival for mitral valve replacement at 4 years was 79.2%+/-6.8%. Freedom from valve-related or unexplained death was 96.5%+/-3.4%; structural valve deterioration, 100%; reoperation, 97.0%+/-3.2%; major thromboembolism, 95.7%+/-3.8%; and major antithrombotic-related hemorrhage, 95.0%+/-4.2%. Echocardiographically measured averaged mean diastolic gradient was 4.5 mm Hg. CONCLUSIONS The Medtronic Mosaic bioprosthesis is safe and effective in both the aortic and mitral positions. The valve has low gradients in both positions and excellent left ventricular mass regression in the patients with aortic valve replacement.


Stroke | 2009

The Erythropoietin NeuroProtective Effect: Assessment in CABG Surgery (TENPEAKS). A Randomized, Double-Blind, Placebo Controlled, Proof-of-Concept Clinical Trial

Gregory Haljan; Andrew Maitland; Alastair M. Buchan; Rakesh C. Arora; Michael King; John Haigh; Bruce Culleton; Peter Faris; David A. Zygun

Background and Purpose— Neurocognitive dysfunction complicates coronary artery bypass surgery. Erythropoietin may be neuroprotective. We sought to determine whether human recombinant erythropoietin would reduce the incidence of neurocognitive dysfunction after surgery. Methods— We randomly assigned 32 elective first-time coronary artery bypass graft patients to receive placebo or 375 U/kg, 750 U/kg, or 1500 U/kg of recombinant human erythropoietin divided in 3 daily doses, starting the day before surgery. Primary outcomes were feasibility and safety, and secondary outcomes were neurocognitive dysfunction at discharge and 2 months. Results— All subjects were male, mean age 60 years (range 46 to 73). No significant differences were found in pump time, cross-clamp time, or hospital length of stay. Mortality and pure red cell aplasia were not observed. One patient in the 375 U/kg group had ST changes compatible with myocardial injury immediately postoperative, but no other thrombotic complications were observed. Neurocognitive dysfunction occurred in 21/32 (66%) of patients at discharge and 5/32 (16%) at 2 months. Neurocognitive dysfunction at discharge by group was: placebo 6/8 (75%), 375 U/kg 4/8 (50%), 750 U/kg 6/8 (75%), and 1500 U/kg 5/8 (63%). Neurocognitive dysfunction at 2 months by group was: placebo 3/8 (38%), 375 U/kg 1/8 (13%), 750 U/kg 1/8 (13%), and 1500 U/kg 0/8 (0%). Neurocognitive dysfunction at 2 months for erythropoietin at any dose was 2/24 (8.3%) versus 3/8 (38%) for placebo (P=0.085). Conclusions— This study demonstrates feasibility and safety for the use of human recombinant erythropoietin as a neuroprotectant in coronary artery bypass graft surgery. A trend in the reduction of neurocognitive dysfunction at 2 months was associated with erythropoietin use. A multicenter randomized controlled trial is warranted.


The Annals of Thoracic Surgery | 2002

Endothelin blockade potentiates endothelial protective effects of ace inhibitors in saphenous veins

Lawrence Ko; Andrew Maitland; Paul W.M. Fedak; Aaron S. Dumont; Mitesh Badiwala; Fina Lovren; Chris R. Triggle; Todd J. Anderson; Vivek Rao; Subodh Verma

BACKGROUND Angiotensin II and endothelin-1 are potent endothelium-derived contracting factors. The effects of acute endothelin antagonism on endothelial function in saphenous vein from patients treated with and without angiotensin-converting enzyme inhibitors were compared. METHODS Vascular segments of saphenous vein were obtained perioperatively from 14 patients on angiotensin-converting enzyme inhibitors and 29 controls. In vitro endothelium-dependent and -independent responses to acetylcholine and sodium nitroprusside were assessed by constructing isometric dose-response curves in precontracted rings in the presence and absence of bosentan (endothelinA/B receptor antagonist) and BQ-123 (endothelinA antagonist) using isolated organ baths. Percent maximum relaxation and sensitivity were compared between interventions. RESULTS Endothelium-dependent relaxation to acetylcholine was augmented in the angiotensin-converting enzyme inhibitor-treated group (p < 0.005). Both specific and mixed endothelin receptor blockade improved acetylcholine-mediated relaxation in the angiotensin-converting enzyme inhibitor-treated and untreated groups (p < 0.02). The effects of these antagonists were endothelium specific as endothelium-independent responses to sodium nitroprusside remain unaltered. CONCLUSIONS These data demonstrate that (1) chronic angiotensin-converting enzyme inhibition improves endothelial function in saphenous veins, and (2) this effect can be further augmented by acute endothelin blockade. These data suggest that antagonism of both angiotensin II and endothelin may be important in attenuating saphenous vein arteriosclerosis.

Collaboration


Dive into the Andrew Maitland's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Shu-Hong Li

University Health Network

View shared research outputs
Top Co-Authors

Avatar

Vivek Rao

University Health Network

View shared research outputs
Researchain Logo
Decentralizing Knowledge