Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Andrzej Cieszanowski is active.

Publication


Featured researches published by Andrzej Cieszanowski.


PLOS ONE | 2014

Non-Contrast-Enhanced Whole-Body Magnetic Resonance Imaging in the General Population: The Incidence of Abnormal Findings in Patients 50 Years Old and Younger Compared to Older Subjects

Andrzej Cieszanowski; Edyta Maj; Piotr Kulisiewicz; Ireneusz P. Grudzinski; Karolina Jakoniuk-Glodala; Irena Chlipala-Nitek; Bartosz Kaczynski; Olgierd Rowiński

Purpose To assess and compare the incidence of abnormal findings detected during non-contrast-enhanced whole-body magnetic resonance imaging (WB-MRI) in the general population in two age groups: (1) 50 years old and younger; and (2) over 50 years old. Materials and Methods The analysis included 666 non-contrast-enhanced WB-MRIs performed on a 1.5-T scanner between December 2009 and June 2013 in a private hospital in 451 patients 50 years old and younger and 215 patients over 50 years old. The following images were obtained: T2-STIR (whole body-coronal plane), T2-STIR (whole spine-sagittal), T2-TSE with fat-saturation (neck and trunk-axial), T2-FLAIR (head-axial), 3D T1-GRE (thorax-coronal, axial), T2-TSE (abdomen-axial), chemical shift (abdomen-axial). Detected abnormalities were classified as: insignificant (type I), potentially significant, requiring medical attention (type II), significant, requiring treatment (type III). Results There were 3375 incidental findings depicted in 659 (98.9%) subjects: 2997 type I lesions (88.8%), 363 type II lesions (10.8%) and 15 type III lesions (0.4%), including malignant or possibly malignant lesions in seven subjects. The most differences in the prevalence of abnormalities on WB-MRI between patients 50 years old and younger and over 50 years old concerned: brain infarction (22.2%, 45.0% respectively), thyroid cysts/nodules (8.7%, 18.8%), pulmonary nodules (5.0%, 16.2%), significant degenerative disease of the spine (23.3%, 44.5%), extra-spinal degenerative disease (22.4%, 61.1%), hepatic steatosis (15.8%, 24.9%), liver cysts/hemangiomas (24%, 34.5%), renal cysts (16.9%, 40.6%), prostate enlargement (5.1% of males, 34.2% of males), uterine fibroids (16.3% of females, 37.9% of females). Conclusions Incidental findings were detected in almost all of the subjects. WB-MRI demonstrated that the prevalence of the vast majority of abnormalities increases with age.


European Journal of Radiology | 2013

Detection of active bile leak with Gd-EOB-DTPA enhanced MR cholangiography: Comparison of 20–25 min delayed and 60–180 min delayed images

Andrzej Cieszanowski; Anna Stadnik; Aleksandra Lezak; Edyta Maj; K. Zieniewicz; Katarzyna Rowinska-Berman; Ireneusz P. Grudzinski; Marek Krawczyk; Olgierd Rowiński

OBJECTIVES The purpose of this study was to assess the value of contrast-enhanced magnetic resonance cholangiography (MRC) performed in different time delays after injection of gadoxetic acid disodium (Gd-EOB-DTPA) for the diagnosis of active bile leak. METHODS This retrospective analysis included Gd-EOB-DTPA enhanced MR images of 34 patients suspected of bile leak. Images were acquired 20-25 min after Gd-EOB-DTPA injection. If there was inadequate contrast in the bile ducts then delayed images after 60-90 min and 150-180 min were obtained. Results were correlated with intraoperative findings, ERCP results, clinical data, laboratory tests, and follow-up examinations. RESULTS Gd-EOB-DTPA enhanced MRC yielded an overall sensitivity of 96.4%, specificity of 100% and accuracy of 97.1% for the diagnosis of an active bile leak. The sensitivity of 20-25 min delayed MR images was 42.9%, of combined 20-25 min and 60-90 min delayed images was 92.9% and of combined 20-25 min, 60-90 min and 150-180 min delayed images was 96.4%. CONCLUSIONS Gd-EOB-DTPA enhanced MRC utilizing delayed phase images was effective for detecting the presence and location of active bile leaks. The images acquired 60-180 min post-injection enabled identification of bile leaks even in patients with a dilated biliary system or moderate liver dysfunction.


Colloids and Surfaces B: Biointerfaces | 2014

Comparative cytotoxicity studies of carbon-encapsulated iron nanoparticles in murine glioma cells.

Ireneusz P. Grudzinski; M. Bystrzejewski; Monika A. Cywinska; Anita Kosmider; Magdalena Poplawska; Andrzej Cieszanowski; Zbigniew Fijałek; Agnieszka Ostrowska

Carbon-encapsulated iron nanoparticles (CEINs) have recently emerged as a new class of magnetic nanomaterials with a great potential for an increasing number of biomedical applications. To address the current deficient knowledge of cellular responses due to CEIN exposures, we focused on the investigation of internalization profile and resulting cytotoxic effects of CEINs (0.0001-100 μg/ml) in murine glioma cells (GL261) in vitro. The studied CEIN samples were characterized (TEM, FT-IR, Zeta potential, Boehm titration) and examined as raw and purified nanomaterials with various surface chemistry composition. Of the four type CEINs (the mean diameter 47-56 nm) studied here, the as-synthesized raw nanoparticles (Fe@C/Fe) exhibited high cytotoxic effects on the plasma cell membrane (LDH, Calcein AM/PI) and mitochondria (MTT, JC-1) causing some pro-apoptotic evens (Annexin V/PI) in glioma cells. The effects of the purified (Fe@C) and surface-modified (Fe@C-COOH and Fe@C-(CH2)2COOH) CEINs were found in quite similar patterns; however, most of these cytotoxic events were slightly diminished compared to those induced by Fe@C/Fe. The study showed that the surface-functionalized CEINs affected the cell cycle progression in both S and G2/M phases to a greater extent compared to that of the rest of nanoparticles studied to data. Taken all together, the present results highlight the importance of the rational design of CEINs as their physicochemical features such as morphology, hydrodynamic size, impurity profiles, and especially surface characteristics are critical determinants of different cytotoxic responses.


PLOS ONE | 2016

MR Imaging of Pulmonary Nodules: Detection Rate and Accuracy of Size Estimation in Comparison to Computed Tomography.

Andrzej Cieszanowski; Antonina Lisowska; Marta Dabrowska; Piotr Korczynski; Malgorzata Zukowska; Ireneusz P. Grudzinski; Ryszard Pacho; Olgierd Rowiński; Rafał Krenke

Objective The aims of this study were to assess the sensitivity of various magnetic resonance imaging (MRI) sequences for the diagnosis of pulmonary nodules and to estimate the accuracy of MRI for the measurement of lesion size, as compared to computed tomography (CT). Methods Fifty patients with 113 pulmonary nodules diagnosed by CT underwent lung MRI and CT. MRI studies were performed on 1.5T scanner using the following sequences: T2-TSE, T2-SPIR, T2-STIR, T2-HASTE, T1-VIBE, and T1-out-of-phase. CT and MRI data were analyzed independently by two radiologists. Results The overall sensitivity of MRI for the detection of pulmonary nodules was 80.5% and according to nodule size: 57.1% for nodules ≤4mm, 75% for nodules >4-6mm, 87.5% for nodules >6-8mm and 100% for nodules >8mm. MRI sequences yielded following sensitivities: 69% (T1-VIBE), 54.9% (T2-SPIR), 48.7% (T2-TSE), 48.7% (T1-out-of-phase), 45.1% (T2-STIR), 25.7% (T2-HASTE), respectively. There was very strong agreement between the maximum diameter of pulmonary nodules measured by CT and MRI (mean difference -0.02 mm; 95% CI –1.6–1.57 mm; Bland-Altman analysis). Conclusions MRI yielded high sensitivity for the detection of pulmonary nodules and enabled accurate assessment of their diameter. Therefore it may be considered an alternative to CT for follow-up of some lung lesions. However, due to significant number of false positive diagnoses, it is not ready to replace CT as a tool for lung nodule detection.


Journal of Applied Toxicology | 2014

Assessing carbon-encapsulated iron nanoparticles cytotoxicity in Lewis lung carcinoma cells

Ireneusz P. Grudzinski; M. Bystrzejewski; Monika A. Cywinska; Anita Kosmider; Magdalena Poplawska; Andrzej Cieszanowski; Zbigniew Fijałek; Agnieszka Ostrowska; Andrzej Parzonko

Carbon‐encapsulated iron nanoparticles (CEINs) have been considered as attractive candidates for several biomedical applications. In the present study, we synthesized CEINs (the mean diameter 40–80 nm) using a carbon arc route, and the as‐synthesized CEINs were characterized (scanning and transmission electron microscopy, dynamic light scattering, turbidimetry, Zeta potential) and further tested as raw and purified nanomaterials containing the carbon surface modified with acidic groups. For cytotoxicity evaluation, we applied a battery of different methods (3‐(4,5‐dimethylthiazol‐2‐yl)‐2,5‐diphenyltetrazolium bromide, lactate dehydrogenase, calcein AM/propidium iodide, annexin V/propidium iodide, JC‐1, cell cycle assay, Zeta potential, TEM and inductively coupled plasma mass spectrometry) to address the strategic cytotoxic endpoints of Lewis lung carcinoma cells due to CEIN (0.0001–100 µg ml–1) exposures in vitro. Our studies evidence that incubation of Lewis lung carcinoma cells with CEINs is accompanied in substantial changes of zeta potential in cells and these effects may result in different internalization profiles. The results show that CEINs increased the mitochondrial and cell membrane cytotoxicity; however, the raw CEIN material (Fe@C/Fe) produced higher toxicities than the rest of the CEINs studied to data. The study showed that non‐modified CEINs (Fe@C/Fe and Fe@C) elevated some pro‐apoptotic events to a greater extent compared to that of the surface‐modified CEINs (Fe@C‐COOH and Fe@C‐(CH2)2COOH). They also diminished the mitochondrial membrane potentials. In contrast to non‐modified CEINs, the surface‐functionalized nanoparticles caused the concentration‐ and time‐dependent arrest of the S phase in cells. Taken all together, our results shed new light on the rational design of CEINs, as their geometry, hydrodynamic and, in particular, surface characteristics are important features in selecting CEINs as future nanomaterials for nanomedicine applications. Copyright


Polish Journal of Radiology | 2012

Pancreatic lipoma: An incydentaloma which can resemble cancer - analysis of 13 cases studied with CT and MRI.

Anna Stadnik; Andrzej Cieszanowski; Leopold Bakoń; Agnieszka Grodzicka; Olgierd Rowiński

Summary Background: The purpose of this article is to present computed tomography (CT) and magnetic resonance imaging (MRI) findings of rare pancreatic lipomas. Material/Methods: The analysis covered 13 patients (7 men and 6 women, aged 47–88, average: 65.6 years), with 13 pancreatic lipomas, whose cases constituted the basis for 10 contrast-enhanced CT and 5 MRI studies. Results: Lipomas measured from 6 mm to 32 mm (average 12.8 mm) and were located in the pancreatic head (n=7), body (n=2), tail (n=3) and uncinate process (n=1). Most lesions (n=11) were homogenous, well-circumscribed. On contrast-enhanced CT scans, macroscopic fat (<−30 HU) was present in 9 lipomas. In one case (10 mm lesion) the density was −20 HU and the lesion was poorly circumscribed with septations, which altogether made it difficult to precisely characterize its contents. On MR scans fat was demonstrated in all studied cases (n=5). Conclusions: Lipomas are rare, small, homogenous and well-circumscribed pancreatic tumours. The most important feature, decisive for the diagnosis and distinguishing them from pancreatic carcinoma, is detection of fatty tissue on CT and MR scans. In these cases differential diagnosis includes other rare fatty tumours of the pancreas (focal fatty infiltration, teratoma, liposarcoma).


Clinical Imaging | 2013

Angiomyolipoma of the liver: analysis of typical features and pitfalls based on own experience and literature

Agnieszka Anysz-Grodzicka; Ryszard Pacho; Mariusz Grodzicki; Lukasz Koperski; Barbara Górnicka; Andrzej Cieszanowski; K. Zieniewicz; Marek Krawczyk

We present imaging findings (ultrasound, computed tomography, and magnetic resonance imaging) of eight patients with hepatic angiomyolipoma (HAML). The lesions were solitary in seven patients, and one patient had multiple tumors (n=11). Angiomyolipoma, even though a rare liver tumor, should be included in the differential diagnosis in cases of highly vascularized lesion containing a significant amount of fat. Suggestion of the diagnosis of HAML might be helpful for the pathologist in the selection of the typical histochemical staining of the tumor, allowing accurate diagnosis, which, in turn, determines the implementation of appropriate therapeutic intervention.


Journal of Magnetic Resonance Imaging | 2017

Diffusion tensor tractography of pyramidal tracts in patients with brainstem and intramedullary spinal cord tumors: Relationship with motor deficits and intraoperative MEP changes

Tomasz Czernicki; Edyta Maj; Anna Podgórska; Przemysław Kunert; Marek Prokopienko; Arkadiusz Nowak; Andrzej Cieszanowski; Andrzej Marchel

To evaluate whether pyramidal tracts course alterations observed in diffusion tensor tractography (DTT) in cases of brainstem and intramedullary spinal cord tumors reflect patient clinical status and prognosis.


Toxicology in Vitro | 2016

Internalization and cytotoxicity effects of carbon-encapsulated iron nanoparticles in murine endothelial cells: Studies on internal dosages due to loaded mass agglomerates

Monika A. Cywinska; M. Bystrzejewski; Magdalena Poplawska; Anita Kosmider; Robert Zdanowski; Sławomir Lewicki; Zbigniew Fijałek; Agnieszka Ostrowska; Magdalena Bamburowicz; Andrzej Cieszanowski; Ireneusz P. Grudzinski

Carbon-encapsulated iron nanoparticles (CEINs) qualified as metal-inorganic hybrid nanomaterials offer a potential scope for an increasing number of biomedical applications. In this study, we have focused on the investigation of cellular fate and resulting cytotoxic effects of CEINs synthesized using a carbon arc route and studied in murine endothelial (HECa-10) cells. The CEIN samples were characterized as pristine (the mean diameter between 47 and 56nm) and hydrodynamic (the mean diameter between 270 and 460nm) forms and tested using a battery of methods to determine the cell internalization extent and cytotoxicity effects upon to the exposures (0.0001-100μg/ml) in HECa-10 cells. Our studies evidenced that the incubation with CEINs for 24h is accompanied with substantial changes of Zeta potential in cells which can be considered as a key factor for affecting the membrane transport, cellular distribution and cytotoxicity of these nanoparticles. The results demonstrate that CEINs have entered the endothelial cell through the endocytic pathway rather than by passive diffusion and they were mainly loaded as agglomerates on the cell membrane and throughout the cytoplasm, mitochondria and nucleus. The studies show that CEINs induce the mitochondrial and cell membrane cytotoxicities in a dose-dependent manner resulting from the internal dosages due to CEIN agglomerates. Our results highlight the importance of the physicochemical characterization of CEINs in studying the magnetic nanoparticle-endothelial cell interactions because the CEIN mass agglomerates can sediment more or less rapidly in culture models.


BioMed Research International | 2016

Diffusion-Weighted Imaging of Small Peritoneal Implants in “Potentially” Early-Stage Ovarian Cancer

Laretta Grabowska-Derlatka; Paweł Derlatka; Wojciech Szeszkowski; Andrzej Cieszanowski

Introduction. MRI is established modality for the diagnosis of ovarian malignancies. Advances in MRI technology, including DW imaging, could lead to the further increase in the sensitivity of MRI for the detection of peritoneal metastases. The aim of this study was to assess the accuracy of DW imaging for detection of peritoneal metastatic disease in patients suspected of having potentially early ovarian cancer and secondly to evaluate ADC values of peritoneal implants. Materials and Methods. The prospective study group consisted of 26 women with sonographic or/and CT diagnosis of suspected ovarian tumor. Based on the results of the above imaging, in none of them was extraovarian spread of disease or ascites recognized. All patients underwent MRI with DW imaging. Results. Overall, 18 extraovarian peritoneal lesions were found on DW images in 10 from 26 examined patients. All implants had diameter ≤10 mm. The presence of all lesions diagnosed by MRI was confirmed intraoperatively. Histopathologic findings in 17 proofs confirmed ovarian cancer. PPV was 94%. On all DW images (with b values of 0, 50, 100, 150, 200, 400, 800, and 1200 s/mm2) the mean signal intensities of peritoneal lesions were significantly higher than the mean signal intensities of normal adjacent tissue (p = 0.000001).

Collaboration


Dive into the Andrzej Cieszanowski's collaboration.

Top Co-Authors

Avatar

Olgierd Rowiński

Medical University of Warsaw

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Edyta Maj

Medical University of Warsaw

View shared research outputs
Top Co-Authors

Avatar

Joanna Podgorska

Medical University of Warsaw

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Monika A. Cywinska

Medical University of Warsaw

View shared research outputs
Top Co-Authors

Avatar

Magdalena Poplawska

Warsaw University of Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Marek Krawczyk

Medical University of Warsaw

View shared research outputs
Top Co-Authors

Avatar

Anita Kosmider

Medical University of Warsaw

View shared research outputs
Researchain Logo
Decentralizing Knowledge