Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Andy Fan is active.

Publication


Featured researches published by Andy Fan.


Analytical Chemistry | 2015

Paper-Based RNA Extraction, in Situ Isothermal Amplification, and Lateral Flow Detection for Low-Cost, Rapid Diagnosis of Influenza A (H1N1) from Clinical Specimens

Natalia M. Rodriguez; Jacqueline C. Linnes; Andy Fan; Courtney K. Ellenson; Nira R. Pollock; Catherine M. Klapperich

The 2009 Influenza A (H1N1) pandemic disproportionately affected the developing world and highlighted the key inadequacies of traditional diagnostic methods that make them unsuitable for use in resource-limited settings, from expensive equipment and infrastructure requirements to unacceptably long turnaround times. While rapid immunoassay diagnostic tests were much less costly and more context-appropriate, they suffered from drastically low sensitivities and high false negative rates. An accurate, sensitive, and specific molecular diagnostic that is also rapid, low-cost, and independent of laboratory infrastructure is needed for effective point-of-care detection and epidemiological control in these developing regions. We developed a paper-based assay that allows for the extraction and purification of RNA directly from human clinical nasopharyngeal specimens through a poly(ether sulfone) paper matrix, H1N1-specific in situ isothermal amplification directly within the same paper matrix, and immediate visual detection on lateral flow strips. The complete sample-to-answer assay can be performed at the point-of-care in just 45 min, without the need for expensive equipment or laboratory infrastructure, and it has a clinically relevant viral load detection limit of 10(6) copies/mL, offering a 10-fold improvement over current rapid immunoassays.


PLOS ONE | 2013

Low Cost Extraction and Isothermal Amplification of DNA for Infectious Diarrhea Diagnosis

Shichu Huang; Jaephil Do; Andy Fan; Lei Zhao; Lisa I. Jepeal; Satish K. Singh; Catherine M. Klapperich

In order to counter the common perception that molecular diagnostics are too complicated to work in low resource settings, we have performed a difficult sample preparation and DNA amplification protocol using instrumentation designed to be operated without wall or battery power. In this work we have combined a nearly electricity-free nucleic acid extraction process with an electricity-free isothermal amplification assay to detect the presence of Clostridium difficile (C. difficile) DNA in the stool of infected patients. We used helicase-dependent isothermal amplification (HDA) to amplify the DNA in a low-cost, thermoplastic reaction chip heated with a pair of commercially available toe warmers, while using a simple Styrofoam insulator. DNA was extracted from known positive and negative stool samples. The DNA extraction protocol utilized an air pressure driven solid phase extraction device run using a standard bicycle pump. The simple heater setup required no electricity or battery and was capable of maintaining the temperature at 65°C±2°C for 55 min, suitable for repeatable HDA amplification. Experiments were performed to explore the adaptability of the system for use in a range of ambient conditions. When compared to a traditional centrifuge extraction protocol and a laboratory thermocycler, this disposable, no power platform achieved approximately the same lower limit of detection (1.25×10−2 pg of C. difficile DNA) while requiring much less raw material and a fraction of the lab infrastructure and cost. This proof of concept study could greatly impact the accessibility of molecular assays for applications in global health.


RSC Advances | 2014

Paper-based molecular diagnostic for Chlamydia trachomatis.

Jacqueline C. Linnes; Andy Fan; Natalia M. Rodriguez; Bertrand Lemieux; Huimin Kong; Catherine M. Klapperich

Herein we show the development of a minimally instrumented paper-based molecular diagnostic for point of care detection of sexually transmitted infections caused by Chlamydia trachomatis. This new diagnostic platform incorporates cell lysis, isothermal nucleic acid amplification, and lateral flow visual detection using only a pressure source and heat block, eliminating the need for expensive laboratory equipment. This paper-based test can be performed in less than one hour and has a clinically relevant limit of detection that is 100x more sensitive than current rapid immunoassays used for chlamydia diagnosis.


Analytical Methods | 2013

A portable, pressure driven, room temperature nucleic acid extraction and storage system for point of care molecular diagnostics

Samantha Byrnes; Andy Fan; Jacob Trueb; Francis Jareczek; Mark Mazzochette; Andre Sharon; Alexis F. Sauer-Budge; Catherine M. Klapperich

Many new and exciting portable HIV viral load testing technologies are emerging for use in global medicine. While the potential to provide fast, isothermal, and quantitative molecular diagnostic information to clinicians in the field will soon be a reality, many of these technologies lack a robust front end for sample clean up and nucleic acid preparation. Such a technology would enable many different downstream molecular assays. Here, we present a portable system for centrifuge-free room temperature nucleic acid extraction from small volumes of whole blood (70 µL), using only thermally stable reagents compatible with storage and transport in low resource settings. Quantitative reverse transcriptase polymerase chain reaction (qRT-PCR) analysis of simulated samples demonstrate a lower limit of detection of 1000 copies/ml, with the ability to detect differences in viral load across four orders of magnitude. The system can also be used to store extracted RNA on detachable cartridges for up to one week at ambient temperature, and can be operated using only hand generated air pressure.


Methods of Molecular Biology | 2013

Purification of DNA/RNA in a microfluidic device.

Andy Fan; Samantha Byrnes; Catherine M. Klapperich

Often, modern diagnostic techniques require the isolation and purification of nucleic acids directly from patient samples such as blood or stool. Many diagnostic tests are being miniaturized onto micro-sized platforms and integrated into microfluidic devices due to the economies resulting from smaller sample and reagent volumes. Often, these devices perform sample preparation in series with the diagnostic tests. The sample preparation steps are vital in order to purify the desired genetic material from potential inhibitors that can interfere with the outcome of the test. There are various techniques used to selectively capture the nucleic acids while washing away potential contamination (proteins, enzymes, lipids, etc.). Two of the most common forms of selective capture are based on nucleic acid binding to silica surface or on the precipitation of nucleic acids with or without the presence of a carrier species. Each of these methods can be performed in liquid phase or in a solid support such as an extraction column. Here we discuss both methods and address microfluidic applications.


international conference of the ieee engineering in medicine and biology society | 2012

Sample concentration and purification for point-of-care diagnostics

Nga T. Ho; Andy Fan; Catherine M. Klapperich; Mario Cabodi

The ability to increase the concentration of target analytes in a fixed sample volume can potentially lower the limit of detection for many biosensing techniques, and thus is key in sample preparation for infectious disease diagnosis. Concentration by evaporation is an effective method to achieve target enrichment. However, concentrating human samples, including blood and plasma, by evaporation-based methods is made challenging by high concentrations of proteins and electrolytes. Dehydration of the proteins causes the sample to turn into a gel, hindering further analysis. At the same time, decreasing the volume increases the overall concentration of electrolytes, causing bacterial or viral particle lysis, and making them more difficult to detect in affinity-based biosensors. Thus, we fabricated a microfluidic chip that incorporates both dialysis and concentration in a single design. The chip dialyzes the proteins from the plasma, while maintaining an appropriate concentration of electrolytes and concentrating the sample targets. The process to concentrate plasma or serum samples by a factor of 10 takes less than 30 minutes. As a proof-of-concept, we demonstrated the chip using a defective Human Immunodeficiency Virus (HIV). To distinguish patients on antiretroviral therapy who are failing therapy from those who are not, a diagnostic must be able to detect HIV in plasma down to at least 1000 particles per milliliter. For a number of technical reasons, it is difficult to get on-chip PCR reactions to reach this level of sensitivity, so concentration of HIV from lower viral load samples has the potential to improve the sensitivity of many types of molecular point-of-care viral load tests.


Journal of Visualized Experiments | 2013

Microfluidic chip fabrication and method to detect influenza.

Qingqing Cao; Andy Fan; Catherine M. Klapperich

Fast and effective diagnostics play an important role in controlling infectious disease by enabling effective patient management and treatment. Here, we present an integrated microfluidic thermoplastic chip with the ability to amplify influenza A virus in patient nasopharyngeal (NP) swabs and aspirates. Upon loading the patient sample, the microfluidic device sequentially carries out on-chip cell lysis, RNA purification and concentration steps within the solid phase extraction (SPE), reverse transcription (RT) and polymerase chain reaction (PCR) in RT-PCR chambers, respectively. End-point detection is performed using an off-chip Bioanalyzer (Agilent Technologies, Santa Clara, CA). For peripherals, we used a single syringe pump to drive reagent and samples, while two thin film heaters were used as the heat sources for the RT and PCR chambers. The chip is designed to be single layer and suitable for high throughput manufacturing to reduce the fabrication time and cost. The microfluidic chip provides a platform to analyze a wide variety of virus and bacteria, limited only by changes in reagent design needed to detect new pathogens of interest.


2013 IEEE Point-of-Care Healthcare Technologies (PHT) | 2013

Monitoring HIV drug adherence with a paper-based assay

George W. Pratt; Andy Fan; Suhina Minocha; Evelyn Orozco; Jose F. Gomez-Marquez; Catherine M. Klapperich

Treating HIV in developing countries involves highly active antiretroviral therapies that require strict adherence by the patient. Current methods of self-reporting to monitor adherence to a drug regimen are less reliable than a drug test. This work introduces proof-of-concept of a new assay involving azide-alkyne cycloaddition to detect the presence of azidothymidine (AZT), a common antiretroviral therapy used in developing countries, in patient urine. Spotting experiments were performed on a paper-based platform with simple materials that selectively detects urine samples containing AZT and these results were confirmed by NMR and UV-Vis spectroscopy. The detection of the assay to AZT was found to be around 12mM. This assay can be translated into a point-of-care set-up that can be used by clinicians to directly monitor patient adherence while increasing efficiency and reducing the costs of health care for HIV patients.


Analytica Chimica Acta | 2018

A competitive lateral flow assay for the detection of tenofovir

George W. Pratt; Andy Fan; Bissrat Melakeberhan; Catherine M. Klapperich

Proper management of an HIV infection requires that a patient be at least 80-95% adherent to a prescribed drug regimen to avoid poor health outcomes and the development of drug-resistant HIV strains. Clinicians generally monitor adherence habits indirectly through patient self-reporting, pill counting, and electronic drug monitoring. While direct measurement of patient samples like urine for monitoring drug levels is possible, it requires specialized equipment and training that is not readily available in resource-limited settings where the need is greatest. In this work we report the development of an antibody that binds to tenofovir (TFV), a key small molecule drug for both the treatment and prevention of HIV, and a competitive lateral flow assay that uses that antibody to monitor urine samples for the presence of the drug. TFV was conjugated to an immunogenic protein and injected into rabbits to raise polyclonal antibodies sensitive to the drug. The antibodies were verified for TFV-sensitivity by immunoprecipitation and HPLC. A gold nanoparticle-based competitive assay was developed to detect the presence of TFV in urine samples with a sensitivity of 1 μg mL-1. This TFV assay could be deployed as a point-of-care device for adherence monitoring in resource-limited settings as a low-cost, accurate, and speedy alternative to current methods to better inform changes in treatment.


PLOS ONE | 2017

Low concentration DNA extraction and recovery using a silica solid phase

Constantinos Katevatis; Andy Fan; Catherine M. Klapperich

DNA extraction from clinical samples is commonly achieved with a silica solid phase extraction column in the presence of a chaotrope. Versions of these protocols have been adapted for point of care (POC) diagnostic devices in miniaturized platforms, but commercial kits require a high amount of input DNA. Thus, when the input clinical sample contains less than 1 μg of total DNA, the target-specific DNA recovery from most of these protocols is low without supplementing the sample with exogenous carrier DNA. In fact, many clinical samples used in the development of POC diagnostics often exhibit target DNA concentrations as low as 3 ng/mL. With the broader goal of improving the yield and efficiency of nucleic acid-based POC devices for dilute samples, we investigated both DNA adsorption and recovery from silica particles by using 1 pg– 1 μg of DNA with a set of adsorption and elution buffers ranging in pH and chaotropic presence. In terms of adsorption, we found that low pH and the presence of chaotropic guanidinium thiocyanate (GuSCN) enhanced DNA-silica adsorption. When eluting with a standard low-salt, high-pH buffer, > 70% of DNA was unrecoverable, except when DNA was initially adsorbed with 5 M GuSCN at pH 5.2. Unrecovered DNA was either not initially adsorbed or irreversibly bound on the silica surface. Recovery was improved when eluting with 95°C formamide and 1 M NaOH, which suggested that DNA-silica-chaotrope interactions are dominated by hydrophobic interactions and hydrogen bonding. While heated formamide and NaOH are non-ideal elution buffers for practical POC devices, the salient results are important for engineering a set of optimized reagents that could maximize nucleic acid recovery from a microfluidic DNA-silica-chaotrope system.

Collaboration


Dive into the Andy Fan's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge