Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Andy Wende.
ASME 2010 8th International Conference on Nanochannels, Microchannels, and Minichannels collocated with 3rd Joint US-European Fluids Engineering Summer Meeting | 2010
Marion Ritzi-Lehnert; Jan Claussen; Eva Schaeffer; Ole Wiborg; Isabell Wick; Klaus Drese; Ralf Himmelreich; Hans Attig; Rainer Dahlke; Gerd Grosshauser; Markus Jeziorski; Andy Wende; Thomas Rothmann
Early diagnosis followed by personalised efficient therapy of infectious diseases (e.g. respiratory diseases, meningitis, sepsis) can lead to considerable reduction of costs in health care. Point-of-care testing (POCT) can provide early detection since this kind of decentralised analysis can be done by unskilled personnel at any time. Other advantages of automated miniaturised Lab-on-a-Chip systems (LoC) are reduction of time and reagents, elimination of cross-contamination and enhanced reproducibility due to enhanced process control. Such Lab-on-a-Chip systems will establish themselves on market only when sensitivity and specificity meet clinical requirements. An integrated cost-efficient lab-on-a-chip system is presented which allows performing all diagnostic process steps for pathogen analysis of respiratory viruses from nasopharyngeal samples. The microfluidic disposable chip comprises structures for lysis of nasopharyngeal swab samples, preparation of total nucleic acids using magnetic silica beads, reverse transcription followed by QIAplex PCR technology and labelling of the nucleic acids by hybridisation with LiquiChip Beads and streptavidin-R-phycoerythrin. Labelled target sequences are transferred for analysis into a QIAGEN LiquiChip 200 workstation. The core of the instrument is a construction based on rotating heating bars allowing for fast cycling. All chemicals needed for performing of 24 analyses are either stored freeze-dried on the single-use disposable microfluidic chip (processing cartridge) or as liquids in a separate reagent cartridge. After introducing the sample into the lysis chamber of the microfluidic chip and inserting the chip into the device all steps are done automatically. To realise these steps, fluidic control in terms of light barriers and turning valves are integrated into the injection moulded disposable chip. This includes metering structures as well as magnetic stir bars for mixing. The functionality was proven by direct comparison of samples processed manually vs. automatically using the “ResPlex Panel II” for detection of respiratory viruses from nasopharyngeal samples. The efficiency of the automated LoC system yields at about 30–60% as compared to the manually performed reference experiments. Comparing the performance of the instrument with commercially available kits and nucleic acid preparation devices showed slightly weaker but clearly positive final signal intensities obtained from the prototype device even without protocol optimization.Copyright
Biomedical Microdevices | 2011
Marion Ritzi-Lehnert; Ralf Himmelreich; Hans Attig; Jan Claußen; Rainer Dahlke; Gerd Großhauser; Eva Holzer; Markus Jeziorski; Eva Schaeffer; Andy Wende; Sabine Werner; Jens Ole Wiborg; Isabell Wick; Klaus Drese; Thomas Rothmann
Archive | 2012
Andy Wende; Rainer Dahlke; Ralf Himmelreich; Thomas Rothmann; Michael Eberhard; Gerd Grosshauser; Markus Jeziorski; Hans Attig; Josef Drexler; Eva Holzer
Archive | 2010
Thomas Rothmann; Holger Engel; Ralf Himmelreich; Andy Wende; Rainer Dahlke
Archive | 2011
Andy Wende; Francesca Dipasquale; Sabine Werner; Sascha Strauss
Archive | 2010
Andy Wende; Hans Attig; Ralf Himmelreich
Archive | 2016
Andy Wende; Ralf Himmelreich
Archive | 2015
Gerd Grosshauser; Andy Wende; Ralf Himmelreich
Archive | 2012
Ralf Himmelreich; Eva Holzer; Gerd Grosshauser; Andy Wende
Archive | 2009
Hans Attig; Ralf Himmelreich; Andy Wende