Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Anjali Upadhyay is active.

Publication


Featured researches published by Anjali Upadhyay.


Analytica Chimica Acta | 2015

Fabrication of novel coated pyrolytic graphite electrodes for the selective nano-level monitoring of Cd2+ ions in biological and environmental samples using polymeric membrane of newly synthesized macrocycle

Manoj Kumar Sahani; Anurupa Singh; Akshay Jain; Anjali Upadhyay; Amit Kumar; Udai P. Singh; Shikha Narang

Novel 5-amino-1,3,4-thiadiazole-2-thiol unit based macrocyclic ionophore 5,11,17-trithia-1,3,7,9,13,15,19,20,21-nonaazatetracyclo[14.2.1.1(4,7).1(10,13)]henicosa-4(20),10(21),16(19)-triene-6,12,18-trithione (M1), was synthesized and characterized. Preliminary studies on M1 have showed that it has more the affinity toward Cd(2+) ion. Thus, the macrocyclic ionophore (M1) was used as electroactive material in the fabrication of PVC-membrane electrodes such as polymeric membrane electrode (PME), coated graphite electrode (CGE) and coated pyrolytic graphite electrode (CPGE) were prepared and its performance characteristic were compared with. The electroanalytical studies performed on PME, CGE and CPGE revealed that CPGE having membrane composition M1:PVC:1-CN:NaTPB in the ratio of 7:37:54:2 exhibits the best potentiometric characteristics in terms of detection limit of 7.58×10(-9) mol L(-1), Nernstian slope of 29.6 mV decade(-1) of activity. The sensor was found to be independent of pH in the range 2.5-8.5. The sensor showed a fast response time of 10s and could be used over a period of 4 months without any significant divergence in its potentiometric characteristics. The sensor has been employed for monitoring of the Cd(2+) ion in real samples and also used as an indicator electrode in the potentiometric titration of Cd(2+) ion with EDTA.


Materials Science and Engineering: C | 2014

Electroanalytical and naked eye determination of Cu2 + ion in various environmental samples using 5-amino-1,3,4-thiadiazole-2-thiol based Schiff bases

Koteswara Rao Bandi; Ashok Kumar Singh; Anjali Upadhyay

Novel polydentate Schiff bases 4-(5-mercapto-1,3,4-thiadiazol-2-ylimino)pentan-2-one (S1) and (2-(indol-3-yl)vinyl)-1,3,4-thiadiazole-2-thiol (S2) were synthesized and explored as Cu(2+) selective polymeric membrane electrodes (PME) using different plasticizers and anionic excluders. The potentiometric data revealed that the PME having the membrane composition (S2: NaTPB: TBP: PVC as 4: 2: 58: 36 (w/w; mg)) is shown to have good results. Thus the coated graphite electrode (CGE) with the same composition as the best PME was also fabricated and investigated as Cu(2+) selective electrode. It was found that CGE showed better response characteristics than PME with respect to low detection limit (1.2×10(-8)molL(-1)), near Nernstian slope (29.8±0.4mV decade(-1) of activity), wide working concentration range (6.4×10(-8)-1.0×10(-1)molL(-1)), long shelf life (90days) and fast response time (9s). The CGE was used successfully as an indicator electrode for the potentiometric determination of Cu(2+) ion against EDTA and also used to quantify Cu(2+) ion in soil, water, medicinal plants, vegetables and edible oil samples. The Schiff base S2 is used as chemosensor for the selective determination of Cu(2+) ion.


Materials Science and Engineering: C | 2014

Construction and performance characteristics of polymeric membrane electrode and coated graphite electrode for the selective determination of Fe3 + ion

Koteswara Rao Bandi; Ashok Kumar Singh; Anjali Upadhyay

Novel Fe(3+) ion-selective polymeric membrane electrodes (PMEs) were prepared using three different ionophores N-(4-(dimethylamino)benzylidene)thiazol-2-amine [L1], 5-((3-methylthiophene-2yl) methyleneamino)-1,3,4-thiadiazole-2-thiol [L2] and N-((3-methylthiophene-2yl)methylene)thiazol-2-amine [L3] and their potentiometric characteristics were discussed. Effect of various plasticizers and anion excluders was also studied in detail and improved performance was observed. The best performance was obtained for the membrane electrode having a composition of L2:PVC:o-NPOE:NaTPB as 3:38.5:56:2.5 (w/w; mg). A coated graphite electrode (CGE) was also prepared with the same composition and compared. CGE is found to perform better as it shows a wider working concentration range of 8.3×10(-8)-1.0×10(-1)molL(-1), a lower detection limit of 2.3×10(-8)molL(-1), and a near Nernstian slope of 19.5 ± 0.4 mVdecade(-1) of activity with a response time of 10s. The CGE shows a shelf life of 6 weeks and in view of high selectivity, it can be used to quantify Fe(3+) ion in water, soil, vegetable and medicinal plants. It can also be used as an indicator electrode in potentiometric titration of EDTA with Fe(3+) ion.


Materials Science and Engineering: C | 2014

Highly selective potentiometric and colorimetric determinations of cobalt (II) ion using thiazole based ligands

Divya Singhal; Ashok Kumar Singh; Anjali Upadhyay

New PVC-membrane electrodes were prepared by using 2-((thiazol-2-ylimino)methyl)phenol (L1) and 2-((thiazol-2-ylamino)methyl)phenol (L2) and explored as Co(II) selective electrodes. The effect of various plasticizers and anion excluder was studied in detail and improved performance was observed. It was found that the electrode based on L1 shows better response characteristics in comparison to L2. Optimum performance was observed for the membrane electrode having a composition of L1:NaTPB:DBP:PVC≡2:8:78:62 (w/w, mg). The performance of PME based on L1 was compared with that of CGE. The electrodes exhibit Nernstian slope for Co(II) ions with a limit of detection of 6.91×10(-7) mol L(-1) for PME and 7.94×10(-8) mol L(-1) for CGE. The response time for PME and CGE was found to be 15s and 12 s respectively. The potentiometric responses are independent in the pH range 3.0-9.0 for CGE. The CGE could be used for a period of 90 days. The CGE was used as an indicator electrode in potentiometric titration of EDTA with Co(2+) ion. Further the selectivity of the L1 and L2 was also confirmed by the UV-vis and colorimetric studies and found that L1 is more selective for Co(II) ion.


Talanta | 2013

Fabrication of coated graphite electrode for the selective determination of europium (III) ions

Anjali Upadhyay; Ashok Kumar Singh; Koteswara Rao Bandi; Ajay K. Jain

Preliminary complexation study showed that two ligands (ionophores) (2-((2-phenyl-2-(pyridin-2-yl)hydazono)methyl)pyridine) [L1], (2-((2-phenyl-2-(pyridin-2-yl)hydazono) methyl)phenol) [L2] can act as europium selective electrode. Europium selective coated graphite electrodes (CGE) were prepared by using ligands [L1] and [L2] and their potentiometric characteristics were determined. Membranes having different compositions of poly(vinylchloride) (PVC), the different plasticizers, anionic additives and ionophores were coated onto the graphite surface. The potential response measurements showed that the best performance was exhibited by the proposed CGE. This electrode had the widest working concentration range, Nernstian slope and fast response times of 10s. The selectivity studies showed that this electrode have higher selectivity towards Eu(3+) over a large number of cations. Furthermore, the electrode generated constant potentials in the pH range 2.7-9.0. This electrode can be used to quantify europium in soil, binary mixtures and also used as an indicator electrode in the potentiometric titration of Eu(3+) with EDTA. The proposed electrode was also successfully applied to the determination of fluoride ions in real samples.


Materials Science and Engineering: C | 2013

A comparative study on fabrication of Mn2+ selective polymeric membrane electrode and coated graphite electrode.

Ashok Kumar Singh; Koteswara Rao Bandi; Anjali Upadhyay; Ajay K. Jain

Poly(vinyl chloride)-based membranes of two ligands 2,4-bis(2-acetoxybenzylamino)-6-phenyl-1,3,5-triazine (L1) and N2,N4-di(cyanoethyl)-2,4-bis(2-acetoxybenzylamino)-6-phenyl-1,3,5-triazine (L2) were fabricated and explored as Mn(2+) ion selective electrodes. The performance of the polymeric membranes electrodes of ionophores with different plasticizers (dibutylphthalate, benzoic acid, o-nitrophenyloctyl ether, 1-chloronapthalene and tri-n-butylphosphate) and anion excluders (sodium tetraphenylborate and potassium tetrakis p-(chloro phenyl)borate) was looked in to and the better results were obtained with the membrane having composition L2: NaTPB: DBP: PVC as 6: 3: 56: 35 (w/w; mg). The coated graphite electrode (CGE) with same composition was also fabricated and investigated as Mn(2+) selective electrode. It was found that CGE showed better response characteristics than PME. The potentiometric response of CGE was independent of pH in the range 3.0-9.0 exhibiting the Nernstian slope 29.5 ± 0.3 mVdecade(-1) of activity and working concentration range 4.1 × 10(-7)-1.0 × 10(-1)mol L(-1) with a limit of detection 6.7 × 10(-8)mol L(-1). The electrode showed a fast response time of 12s with a shelf life of 105 days. The proposed CGE could be successfully used for the determination of Mn(2+) ions in different water, soil, vegetables and medicinal plants also used as an indicator electrode in potentiometric titration with EDTA.


Materials Science and Engineering: C | 2016

Nano-level monitoring of Er(III) by fabrication of coated graphite electrode based on newly synthesized Schiff base as neutral carrier

Koteswara Rao Bandi; Anjali Upadhyay; Ashok Kumar Singh; Akshay Jain

Plasticized membranes using N-(-3-((thiazol-2-ylimino)methyl)benzylidene)thiazol-2-amine (S1) and 5-((-3-((5-mercapto-1,3,4-thiadiazol-2-ylimino)methyl)benzylidene)amino)-1,3,4-thiadiazole-2-thiol (S2) have been prepared and explored as Er (III) selective electrodes. Effect of various plasticizers viz. dibutylphthalate, tri-n-butylphosphate, dioctylphthalate, acetophenone, 1-chloronapthalene, o-nitrophenyloctylether, and anion excluders viz. sodium tetraphenylborate and potassium tetrakis-p-(chlorophenyl)borate was studied in detail and improved performance was observed. Optimum performance was observed for the membrane electrode having a composition of S2: PVC: o-NPOE: KTpClPB in the ratio of 4: 38: 55: 3 (w/w, mg). The performance of the PME based on S2 was compared with CGE. The electrodes exhibit Nernstian slope for Er (III) ion with detection limit 5.4 × 10(-8)mol L(-1) for PME and 6.1 × 10(-9)mol L(-1) for CGE. The response time for PME and CGE was found to be 12s and 9s respectively. The practical utility of the CGE has been demonstrated by its usage as an indicator electrode in potentiometric titration of EDTA with Er (III) solution and determination of fluoride ions in mouthwash solution. The proposed electrode was also applied to the determination of added Er(3+) ion in water and binary mixtures. It is found that the electrode could be able to recover the Er(3+) ion in 96.2-99.5%.


International Journal of Environmental Analytical Chemistry | 2013

Electroanalytical performance of Cd(II) selective sensor based on PVC membranes of 5,5′‐(5,5′‐(benzo[c][1,2,5]thiadiazole‐4,7‐diyl)bis(thiophene‐5,2‐diyl))bis(N1,N1,N3,N3‐tetraphenylbenzene‐1,3‐diamine)

Ashok Kumar Singh; Ajay K. Jain; Anjali Upadhyay; K.R.J. Thomas; Prerna Singh

The construction and performance characteristics of polymeric membrane electrodes based on neutral ionophore 5,5′‐(5,5′‐(benzo[c][1,2,5]thiadiazole‐4,7‐diyl)bis(thiophene‐5,2‐diyl))bis‐(N1,N1,N3,N3‐tetraphenylbenzene‐1,3‐diamine) (L) for quantification of cadmium ions, are described. Effect of plastisizers dibutylpthalate (DBP), tri‐n‐butylphosphate (TBP), dioctylpthalate (DOP), o‐nitrophenyloctyl ether (o‐NPOE), 1‐chloronaphthalene (CN) and ionic additives sodium tetraphenylborate (NaTPB), potassium tetrakis p‐(chlorophenyl)borate (KTpClPB) was studied. Best performance was obtained with the membrane having a composition L : PVC : DBP : NaTPB ≡ 2 : 37 : 59 : 2 (w/w; mg). The membrane electrode exhibits Nernstian response in the concentration range 6.3 × 10−8 to 1.0 × 10 −1 mol L−1 with detection limit 3.6 × 10−8 mol L−1 and is not affected by H+ ions over a wide pH range 3.0–10.0. The electrode possess a fast response time of 10 s and shelf life period of 3 months. The analytical utility of the proposed electrode has demonstrated by its application in the determination of cadmium in water, medicinal plants and soil samples. It could also be used successfully as an indicator electrode in the potentiometric titration of Cd2+ with EDTA (ethylenediaminetetraacetic acid).


Sensors and Actuators B-chemical | 2014

Electrochemical determination of perchlorate ion by polymeric membrane and coated graphite electrodes based on zinc complexes of macrocyclic ligands

Vinod Kumar Gupta; Ashok Kumar Singh; Prerna Singh; Anjali Upadhyay


Electrochimica Acta | 2013

Biologically active Schiff bases as potentiometric sensor for the selective determination of Nd3+ ion

Koteswara Rao Bandi; Ashok Kumar Singh; Anjali Upadhyay

Collaboration


Dive into the Anjali Upadhyay's collaboration.

Top Co-Authors

Avatar

Ashok Kumar Singh

Indian Institute of Technology Roorkee

View shared research outputs
Top Co-Authors

Avatar

Koteswara Rao Bandi

Indian Institute of Technology Roorkee

View shared research outputs
Top Co-Authors

Avatar

Ajay K. Jain

Indian Institute of Technology Roorkee

View shared research outputs
Top Co-Authors

Avatar

Prerna Singh

Indian Institute of Technology Roorkee

View shared research outputs
Top Co-Authors

Avatar

Akshay Jain

Indian Institute of Technology Roorkee

View shared research outputs
Top Co-Authors

Avatar

Vinod Kumar Gupta

University of Johannesburg

View shared research outputs
Top Co-Authors

Avatar

A.K. Singh

Indian Institute of Technology Roorkee

View shared research outputs
Top Co-Authors

Avatar

Amit Kumar

Indian Institute of Technology Roorkee

View shared research outputs
Top Co-Authors

Avatar

Anurupa Singh

Indian Institute of Technology Roorkee

View shared research outputs
Top Co-Authors

Avatar

Divya Singhal

Indian Institute of Technology Roorkee

View shared research outputs
Researchain Logo
Decentralizing Knowledge