Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Anna Maria Pistritto is active.

Publication


Featured researches published by Anna Maria Pistritto.


American Journal of Cardiology | 2011

Dual Antiplatelet Therapy Versus Aspirin Alone in Patients Undergoing Transcatheter Aortic Valve Implantation

Gian Paolo Ussia; Marilena Scarabelli; Massimiliano Mulè; Marco Barbanti; Kunal Sarkar; Valeria Cammalleri; Sebastiano Immè; Patrizia Aruta; Anna Maria Pistritto; Simona Gulino; Wanda Deste; Davide Capodanno; Corrado Tamburino

Dual antiplatelet therapy (DAPT) with clopidogrel and aspirin is a widely accepted strategy in patients undergoing transcatheter aortic valve implantation (TAVI), but this approach is not evidence based. The goal of the present study was to determine whether DAPT in patients undergoing TAVI is associated with improved outcomes compared to aspirin alone. From May 2009 to August 2010, consecutive patients were randomized to receive a 300-mg loading dose of clopidogrel on the day before TAVI followed by a 3-month maintenance daily dose of 75 mg plus aspirin 100 mg lifelong (DAPT group) or aspirin 100 mg alone (ASA group). The primary end point was the composite of major adverse cardiac and cerebrovascular events, defined as death from any cause, myocardial infarction, major stroke, urgent or emergency conversion to surgery, or life-threatening bleeding. The cumulative incidence of major adverse cardiac and cerebrovascular events at 30 days and 6 months was 14% and 16%, respectively. No significant differences between the DAPT and ASA groups were noted at both 30 days (13% vs 15%, p = 0.71) and 6 months (18% vs 15%; p = 0.85). In conclusion, the strategy of adding clopidogrel to aspirin for 3 months after TAVI was not found to be superior to aspirin alone. These results must be confirmed in a larger randomized trial.


American Journal of Cardiology | 2013

One- and Twelve-Month Safety and Efficacy Outcomes of Patients Undergoing Edge-to-Edge Percutaneous Mitral Valve Repair (from the GRASP Registry)

Carmelo Grasso; Davide Capodanno; Salvatore Scandura; Stefano Cannata; Sebastiano Immè; Sarah Mangiafico; Anna Maria Pistritto; Margherita Ministeri; Marco Barbanti; Anna Caggegi; Marta Chiarandà; Fabio Dipasqua; Sandra Giaquinta; Michele Occhipinti; Gianpaolo Ussia; Corrado Tamburino

The aim of this study was to report on the 30-day and 1-year outcomes of percutaneous mitral valve repair with the MitraClip technique in patients with grade ≥3+ mitral regurgitation (MR) at high risk for conventional surgical therapy enrolled in the prospective Getting Reduction of Mitral Insufficiency by Percutaneous Clip Implantation (GRASP) registry. Acute device success was defined as residual MR ≤2+ after clip implantation. The primary safety end point was the rate of major adverse events at 30 days. The primary efficacy end point was freedom from death, surgery for mitral valve dysfunction, or grade ≥3+ MR at 30 days and 1 year. A total of 117 patients were treated. Eighty-nine patients (76%) presented with functional MR and 28 patients (24%) with organic MR. Acute device success was observed in all patients. Device implantation time significantly diminished with experience and varied significantly between cases with 1 versus ≥2 clips. No procedural mortality was recorded. Major adverse events occurred in 4 patients at 30 days (4.3%). Deterioration to MR ≥3+ was recorded in 25% of patients with degenerative MR and 7% of those with functional MR at 1 year. No surgery for mitral valve dysfunction occurred within 1 year. Freedom from death, surgery for mitral valve dysfunction, or grade ≥3+ MR was 96.4% and 75.8% at 30 days and 1 year, respectively. No significant differences were noted in the primary efficacy end point between patients with degenerative MR and those with functional MR. In conclusion, percutaneous mitral valve repair with the MitraClip technique was shown to be safe and reasonably effective in 117 patients from a real-world setting.


American Journal of Cardiology | 2012

Comparison of Complications and Outcomes to One Year of Transcatheter Aortic Valve Implantation Versus Surgical Aortic Valve Replacement in Patients With Severe Aortic Stenosis

Corrado Tamburino; Marco Barbanti; Davide Capodanno; Carmelo Mignosa; Maurizio Gentile; Patrizia Aruta; Anna Maria Pistritto; Claudio Bonanno; Salvatore Bonura; Alessandra Cadoni; Simona Gulino; Maria Concetta Di Pasqua; Valeria Cammalleri; Marilena Scarabelli; Massimiliano Mulè; Sebastiano Immè; Giuliana Del Campo; Gian Paolo Ussia

Comparisons of transcatheter aortic valve implantation (TAVI) to surgical aortic valve replacement (SAVR) in patients with severe aortic stenosis remain sparse or limited by a short follow-up. We sought to evaluate early and midterm outcomes of consecutive patients (n = 618) undergoing successful TAVI (n = 218) or isolated SAVR (n = 400) at 2 centers. The primary end point was incidence of Valvular Academic Research Consortium-defined major adverse cerebrovascular and cardiac events (MACCEs) up to 1 year. Control of potential confounders was attempted with extensive statistical adjustment by covariates and/or propensity score. In-hospital MACCEs occurred in 73 patients (11.8%) and was more frequent in patients treated with SAVR compared to those treated with TAVI (7.8% vs 14.0%, p = 0.022). After addressing potential confounders using 3 methods of statistical adjustment, SAVR was consistently associated with a higher risk of MACCEs than TAVI, with estimates of relative risk ranging from 2.2 to 2.6 at 30 days, 2.3 to 2.5 at 6 months, and 2.0 to 2.2 at 12 months. This difference was driven by an adjusted increased risk of life-threatening bleeding at 6 and 12 months and stroke at 12 months with SAVR. Conversely, no differences in adjusted risk of death, stroke and myocardial infarction were noted between TAVI and SAVR at each time point. In conclusion, in a large observational registry with admitted potential for selection bias and residual confounding, TAVI was not associated with a higher risk of 1-year MACCEs compared to SAVR.


Jacc-cardiovascular Interventions | 2015

Extended use of percutaneous edge-to-edge mitral valve repair beyond EVEREST (Endovascular Valve Edge-to-Edge Repair) criteria: 30-day and 12-month clinical and echocardiographic outcomes from the GRASP (Getting Reduction of Mitral Insufficiency by Percutaneous Clip Implantation) registry.

Guilherme F. Attizzani; Yohei Ohno; Davide Capodanno; Stefano Cannata; Fabio Dipasqua; Sebastiano Immè; Sarah Mangiafico; Marco Barbanti; Margherita Ministeri; Anna Cageggi; Anna Maria Pistritto; Sandra Giaquinta; Silvia Farruggio; Marta Chiarandà; Giuseppe Ronsivalle; Audrey Schnell; Salvatore Scandura; Corrado Tamburino; Piera Capranzano; Carmelo Grasso

OBJECTIVES This study sought to compare, in high-risk patients with 3+ to 4+ mitral regurgitation (MR) dichotomized by baseline echocardiographic features, acute, 30-day, and 12-month outcomes following percutaneous mitral valve repair using the MitraClip. BACKGROUND The feasibility and mid-term outcomes after MitraClip implantation in patients with echocardiographic features different from the EVEREST (Endovascular Valve Edge-to-Edge Repair) I and II trials have been scarcely studied. METHODS Clinical and echocardiographic outcomes through 12-month follow-up of consecutive patients who underwent MitraClip implantation were obtained from an ongoing prospective registry. Two different groups, divided according to baseline echocardiographic criteria (investigational group [EVERESTOFF] and control group [EVERESTON]), were compared. RESULTS Seventy-eight patients were included in EVERESTOFF and 93 patients in EVERESTON groups. Important and comparable acute reductions in MR and no clip-related complications were revealed. The primary safety endpoint at 30 days was comparable between groups (2.6% vs. 6.5%, respectively, p = 0.204); in addition, MR reduction was mostly sustained, whereas equivalent improvement in New York Heart Association functional class were demonstrated. Kaplan-Meier freedom from death, surgery for mitral valve dysfunction, or grade ≥3+ MR at 12 months was demonstrated in 71.4% and 76.2%, respectively, in the EVERESTOFF and EVERESTON groups (log rank p = 0.378). Significant improvements in ejection fraction and reduction in left ventricle volumes were demonstrated in both groups over time, but the baseline between-group differences were sustained. CONCLUSIONS MitraClip implantation in patients with expanded baseline echocardiographic features, compared with the control group, was associated with similar rates of safety and efficacy through 12-month follow-up. Further validation of our findings is warranted.


Catheterization and Cardiovascular Interventions | 2010

Management of implant failure during transcatheter aortic valve implantation

Gian Paolo Ussia; Marco Barbanti; Sebastiano Immè; Marilena Scarabelli; Massimiliano Mulè; Valeria Cammalleri; Patrizia Aruta; Anna Maria Pistritto; Davide Capodanno; Wanda Deste; Maria Concetta Di Pasqua; Corrado Tamburino

Background: Transcatheter aortic valve implantation (TAVI) is an emerging alternative to palliative medical therapy for nonsurgical patients with severe aortic stenosis. There is a paucity of detailed data on the management and outcome of complications related to the sub‐optimal deployment of the prosthesis. We appraised the incidence and management of early implant failure occurring during TAVI. Methods: Of 110 patients who underwent TAVI using the third generation 18‐French CoreValve ReValving System (Medtronic, MN) in our Institution between June 2007 and January 2010, we identified those experiencing early implant failure and reported on their management and clinical outcome. The primary endpoint was the incidence of major adverse cardiovascular and cerebrovascular event (MACCE) at 30 days and mid‐term follow up. Results: Early implant failure occurred in 18 of 110 patients (16.3%). The most common cause was prosthesis under‐expansion conditioning moderate to severe peri‐valvular leak (44.4%). Prosthesis deployment too low or too high with respect to the aortic annulus leading to severe peri‐valvular leak occurred in 22.2% and 5.5% of patients, respectively. Need of valve retrieve after the first attempt of deployment occurred in four cases (22.2%). Prosthesis embolization in the ascending aorta occurred in 5.5% of patients who experienced early implant failure. All implant failure cases were managed percutaneously with gain in aortic valve area from 0.44 ± 0.17 to 1.28 ± 0.27 cm2 (P < 0.001), decrease of mean transaortic gradient from 55.00 ± 19.51 to 11.58 ± 5.91 mmHg (P < 0.001) and no MACCE at 30 days. After 11 ± 6 months, MACCE occurred cumulatively in two patients (11.1%). Conclusions: Early implant failure can complicate the TAVI procedure with the CoreValve system, but it can be managed safely and effectively with bailout transcatheter techniques, avoiding surgery, with good early and mid‐term clinical and echocardiographic results.


European Journal of Echocardiography | 2014

Association of tricuspid regurgitation with clinical and echocardiographic outcomes after percutaneous mitral valve repair with the MitraClip System: 30-day and 12-month follow-up from the GRASP Registry

Yohei Ohno; Guilherme F. Attizzani; Davide Capodanno; Stefano Cannata; Fabio Dipasqua; Sebastiano Immè; Marco Barbanti; Margherita Ministeri; Anna Caggegi; Anna Maria Pistritto; Marta Chiarandà; Giuseppe Ronsivalle; Sandra Giaquinta; Silvia Farruggio; Sarah Mangiafico; Salvatore Scandura; Corrado Tamburino; Piera Capranzano; Carmelo Grasso

AIM The aim of this study was to evaluate the association of baseline tricuspid regurgitation (TR) on the outcomes after percutaneous mitral valve repair (PMVR) with the MitraClip system. METHODS AND RESULTS Data from 146 consecutive patients with functional mitral regurgitation (MR) were obtained. Two different groups, dichotomized according to the degree of pre-procedural TR (moderate/severe, n = 47 and none/mild, n = 99), had their clinical and echocardiographic outcomes through 12-month compared. At 30-day, the primary safety endpoint was significantly higher in moderate/severe TR compared with none/mild TR (10.6 vs. 2.0%, P = 0.035). Marked reduction in MR grades observed post-procedure were maintained through 12 months. Although NYHA functional class significantly improved in both groups compared with baseline, it was impaired in moderate/severe TR compared with the none/mild TR group (NYHA > II at 30 day: 33.3 vs. 9.2%, P < 0.001; at 1 year: 38.5 vs. 12.3%, respectively, P = 0.006). Left ventricle reverse remodelling and ejection fraction improvement were revealed in both groups. The primary efficacy endpoint at 12-month determined by freedom from death, surgery for mitral valve dysfunction, or grade ≥ 3+ MR was comparable between groups, but combined death and re-hospitalization for heart failure rates were higher in the moderate/severe TR group. Multivariable Cox regression analysis demonstrated that baseline moderate/severe TR and chronic kidney disease were independent predictors of this combined endpoint. CONCLUSIONS Although PMVR with MitraClip led to improvement in MR, TR, and NYHA functional class in patients with baseline moderate/severe TR, the primary safety endpoint at 30-day was impaired, while moderate/severe TR independently predicted death and re-hospitalization for heart failure at 12-month.


Eurointervention | 2011

Quality-of-life in elderly patients one year after transcatheter aortic valve implantation for severe aortic stenosis.

Gian Paolo Ussia; Marco Barbanti; Cammalleri; Scarabelli M; Mulè M; Aruta P; Anna Maria Pistritto; Sebastiano Immè; Davide Capodanno; Sarkar K; Gulino S; Corrado Tamburino

AIMS Transcatheter aortic valve implantation (TAVI) is an emerging alternative to medical therapy reserved to a limited population with severe aortic stenosis. Quality-of-life (QoL) is a critical measure of effectiveness of TAVI in this patient population. In this prospective study, we sought to assess one year changes in QoL in patients who underwent TAVI. METHODS AND RESULTS From June 2007 to July 2010, 149 consecutive patients underwent TAVI using the 18 Fr CoreValve (Medtronic Inc, Minneapolis, MN, USA) or the Edwards SAPIEN XT heart valve (Edwards Lifescience, Irvine, CA, USA) at our institution. Of these, 143 patients with successful prosthesis implantation comprised the study population. The SF-12v2 Health-Survey questionnaire provides scales for physical (physical component summary [PCS]) and mental (mental component summary [MCS]) health. Among patients included in the present analysis, device success was obtained in 138 patients (96.5%). Mean preprocedural SF-12v2 scores showed an important upgrading after TAVI: PCS improved from 28.3 to 44.0 at five months and 42.4 at 12 months (p<0.001). MCS increased from 38.0 to 47.3 at five months and 48.2 at 12 months (p<0.001). Both the physical and mental score summaries at follow-up of these post-TAVI patients were not significantly different from the anticipated thresholds of the general Italian population over the age of 75 years. NYHA functional class improvement was reported in all patients. CONCLUSIONS Our results showed a marked mid-term improvement in functional status and physical and mental health in patients who underwent TAVI.


Catheterization and Cardiovascular Interventions | 2010

Postprocedural management of patients after transcatheter aortic valve implantation procedure with self‐expanding bioprosthesis

Gian Paolo Ussia; Marilena Scarabelli; Massimiliano Mulè; Marco Barbanti; Valeria Cammalleri; Sebastiano Immè; Patrizia Aruta; Anna Maria Pistritto; Alessandro Carbonaro; Wanda Deste; Paolo Sciuto; Giovanni Licciardello; Valeria Calvi; Corrado Tamburino

Background: Transcatheter aortic valve implantation (TAVI) carries higher risk of post‐procedural adverse events than conventional percutaneous cardiovascular interventions. We report our experience about postoperative management protocol adopted in our Division. Methods: One hundred and ten patients underwent TAVI and 108 were transferred to the cardiac intensive care unit (CICU) after procedure. During the first 48 hours, vital parameters were monitored continuously. Close attention was given to rhythm and atrio‐ventricular conduction disturbances, systemic blood pressure, fluid balance and vascular accesses. Results: The most common complications were renal impairment (21.3%), femoral artery pseudo‐aneurysms (FAP) (11%), new complete atrioventricular block (20.3 %), cerebral vascular accident (4.5%) and cardiac perforation due to temporary pacemaker lead (1.8%). Ultrasound‐guided compression repair was considered the first line treatment for FAP, but in 6 cases surgical treatment was immediately performed due to the rapid expansion of FAP. Complete atrio‐ventricular block occurred in 22 patients (20.3 %) within the first 24 hours after TAVI and a permanent pacemaker was implanted in 21 patients (19.1%). Acute kidney injury occurred in 18 patients (35%) with pre‐procedural chronic renal failure and in 5 patients (9%) without preoperative renal dysfunction. Conclusions: After TAVI, cardiovascular complications are common and therefore accurate standardized management of patients in CICU during the first 48 hours is mandatory to early detect and manage complications and to decrease the rate of adverse events and the length of in‐hospital stay.


International Journal of Cardiology | 2012

Quality of life following percutaneous mitral valve repair with the MitraClip System

Gian Paolo Ussia; Valeria Cammalleri; Kunal Sarkar; Salvatore Scandura; Sebastiano Immè; Anna Maria Pistritto; Anna Caggegi; Marta Chiarandà; Sarah Mangiafico; Marco Barbanti; Marilena Scarabelli; Massimiliano Mulè; Patrizia Aruta; Corrado Tamburino

BACKGROUND Percutaneous valve repair with MitraClip System is an emerging alternative for high surgical risk patients with severe mitral regurgitation (MR). QoL is a critical measure of effectiveness of this procedure. We sought to evaluate quality of life (QoL) and NYHA class following this novel procedure. METHODS The study included 39 consecutive patients who underwent mitral valve repair with the MitraClip System, both for functional (64%) and degenerative (36%) MR. All patients received the SF-12v2 questionnaire pre-procedure and at 6 months follow-up to assess the physical and mental health. RESULTS Acute procedural success was obtained in 100%. Three patients experienced minor procedural complications. At follow-up 86% of patients had MR ≤ 1+ and 14% experienced a moderate MR. Mean pre-procedural SF-12v2 scores of our patients showed a severe impairment of perceived QoL, both for physical and mental scores; after six months a striking improvement in physical (PCS 35.44 vs 44.67, p<0.0001) and mental (MCS 38.07 vs 46.94, p<0.0001) aspect of QoL was observed. Furthermore, physical and mental status upgrading was higher in patients with functional MR. NYHA functional class improved in all patients. CONCLUSION Our results show an early marked improvement in functional status and physical and mental health in patients underwent percutaneous mitral valve repair with the MitraClip System.


Journal of The American Society of Echocardiography | 2012

Left Cardiac Chambers Reverse Remodeling after Percutaneous Mitral Valve Repair with the MitraClip System

Salvatore Scandura; Gian Paolo Ussia; Piera Capranzano; Anna Caggegi; Kunal Sarkar; Valeria Cammalleri; Sarah Mangiafico; Marta Chiarandà; Sebastiano Immè; Fabio Di Pasqua; Anna Maria Pistritto; Giovanni Millan; Corrado Tamburino

BACKGROUND Successful mitral valve surgical repair, decreasing volume overload, has been shown to provide reverse left ventricular (LV) and/or left atrial remodeling in most patients. Percutaneous mitral valve repair with the MitraClip system (Abbott, Abbott Park, IL) has been associated with favorable clinical outcomes in patients with mitral regurgitation at high risk of surgery. However, specific data on left cardiac chambers reverse remodeling after such procedures are limited. METHODS This was a prospective observational study of consecutive patients at high risk of surgery, with moderate-to-severe or severe mitral regurgitation undergoing MitraClip system implantation. Follow-up echocardiography was performed at 6 months. The evaluated parameters were the LV end-diastolic and end-systolic volume indexes, LV sphericity index, LV ejection fraction, and left atrial volume index. Reverse LV remodeling was defined as a decrease of 10% in the LV end-diastolic volume index. RESULTS The study population included 44 patients: 14 with degenerative and 30 with functional mitral regurgitation. At 6 months of follow-up, significant reductions in the median and interquartile range of the sphericity index (from 0.57 [interquartile range 0.54-0.62] to 0.54 [interquartile range 0.50-0.58]; P < .001), LV end-diastolic volume index (from 79.4 mL/m(2) [interquartile range 63.0-102.2] to 60.7 mL/m(2) [50.8-84.4]; P < .001), and LV end-systolic volume index (from 49.3 mL/m(2) [interquartile range 28.2-70.5] to 28.9 mL/m(2) [interquartile range 22.2-55.8]; P < .001) were observed. The LV ejection fraction improved significantly (from 38.0% [interquartile range 30.0-55.0%] to 46.0% [interquartile range 35.0-58.0%]; P < .001) from baseline to 6 months. Minor differences in the left atrial volume index were observed. Reverse remodeling, according to the specified definition, was observed in 77.3% of the patients. CONCLUSIONS The present study reports positive LV reshape effects after mitral valve repair with the MitraClip system, showing significant improvements in LV size and function.

Collaboration


Dive into the Anna Maria Pistritto's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge