Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Anna Sonia Petronio is active.

Publication


Featured researches published by Anna Sonia Petronio.


The Lancet | 2007

Outcomes associated with drug-eluting and bare-metal stents: a collaborative network meta-analysis

Christoph Stettler; Simon Wandel; Sabin Allemann; Adnan Kastrati; Marie Claude Morice; Albert Schömig; Matthias Pfisterer; Gregg W. Stone; Martin B. Leon; José Suárez de Lezo; Jean-Jacques Goy; Seung-Jung Park; Manel Sabaté; Maarten J. Suttorp; Henning Kelbæk; Christian Spaulding; Maurizio Menichelli; Paul Vermeersch; Maurits T. Dirksen; Pavel Cervinka; Anna Sonia Petronio; Alain J Nordmann; Peter Diem; Bernhard Meier; Marcel Zwahlen; Stephan Reichenbach; Sven Trelle; Stephan Windecker; Peter Jüni

BACKGROUND Whether the two drug-eluting stents approved by the US Food and Drug Administration-a sirolimus-eluting stent and a paclitaxel-eluting stent-are associated with increased risks of death, myocardial infarction, or stent thrombosis compared with bare-metal stents is uncertain. Our aim was to compare the safety and effectiveness of these stents. METHODS We searched relevant sources from inception to March, 2007, and contacted investigators and manufacturers to identify randomised controlled trials in patients with coronary artery disease that compared drug-eluting with bare-metal stents, or that compared sirolimus-eluting stents head-to-head with paclitaxel-eluting stents. Safety outcomes included mortality, myocardial infarction, and definite stent thrombosis; the effectiveness outcome was target lesion revascularisation. We included 38 trials (18,023 patients) with a follow-up of up to 4 years. Trialists and manufacturers provided additional data on clinical outcomes for 29 trials. We did a network meta-analysis with a mixed-treatment comparison method to combine direct within-trial comparisons between stents with indirect evidence from other trials while maintaining randomisation. FINDINGS Mortality was similar in the three groups: hazard ratios (HR) were 1.00 (95% credibility interval 0.82-1.25) for sirolimus-eluting versus bare-metal stents, 1.03 (0.84-1.22) for paclitaxel-eluting versus bare-metal stents, and 0.96 (0.83-1.24) for sirolimus-eluting versus paclitaxel-eluting stents. Sirolimus-eluting stents were associated with the lowest risk of myocardial infarction (HR 0.81, 95% credibility interval 0.66-0.97, p=0.030 vs bare-metal stents; 0.83, 0.71-1.00, p=0.045 vs paclitaxel-eluting stents). There were no significant differences in the risk of definite stent thrombosis (0 days to 4 years). However, the risk of late definite stent thrombosis (>30 days) was increased with paclitaxel-eluting stents (HR 2.11, 95% credibility interval 1.19-4.23, p=0.017 vs bare-metal stents; 1.85, 1.02-3.85, p=0.041 vs sirolimus-eluting stents). The reduction in target lesion revascularisation seen with drug-eluting stents compared with bare-metal stents was more pronounced with sirolimus-eluting stents than with paclitaxel-eluting stents (0.70, 0.56-0.84; p=0.0021). INTERPRETATION The risks of mortality associated with drug-eluting and bare-metal stents are similar. Sirolimus-eluting stents seem to be clinically better than bare-metal and paclitaxel-eluting stents.


Circulation | 2011

Incidence and Predictors of Early and Late Mortality After Transcatheter Aortic Valve Implantation in 663 Patients With Severe Aortic Stenosis

Corrado Tamburino; Davide Capodanno; Angelo Ramondo; Anna Sonia Petronio; Federica Ettori; Gennaro Santoro; Silvio Klugmann; Francesco Bedogni; Francesco Maisano; Antonio Marzocchi; Arnaldo Poli; David Antoniucci; Massimo Napodano; Marco De Carlo; Claudia Fiorina; Gian Paolo Ussia

Background— There is a lack of information on the incidence and predictors of early mortality at 30 days and late mortality between 30 days and 1 year after transcatheter aortic valve implantation (TAVI) with the self-expanding CoreValve Revalving prosthesis. Methods and Results— A total of 663 consecutive patients (mean age 81.0±7.3 years) underwent TAVI with the third generation 18-Fr CoreValve device in 14 centers. Procedural success and intraprocedural mortality were 98% and 0.9%, respectively. The cumulative incidences of mortality were 5.4% at 30 days, 12.2% at 6 months, and 15.0% at 1 year. The incidence density of mortality was 12.3 per 100 person-year of observation. Clinical and hemodynamic benefits observed acutely after TAVI were sustained at 1 year. Paravalvular leakages were trace to mild in the majority of cases. Conversion to open heart surgery (odds ratio [OR] 38.68), cardiac tamponade (OR 10.97), major access site complications (OR 8.47), left ventricular ejection fraction <40% (OR 3.51), prior balloon valvuloplasty (OR 2.87), and diabetes mellitus (OR 2.66) were independent predictors of mortality at 30 days, whereas prior stroke (hazard ratio [HR] 5.47), postprocedural paravalvular leak ≥2+ (HR 3.79), prior acute pulmonary edema (HR 2.70), and chronic kidney disease (HR 2.53) were independent predictors of mortality between 30 days and 1 year. Conclusions— Benefit of TAVI with the CoreValve Revalving System is maintained over time up to 1 year, with acceptable mortality rates at various time points. Although procedural complications are strongly associated with early mortality at 30 days, comorbidities and postprocedural paravalvular aortic regurgitation ≥2+ mainly impact late outcomes between 30 days and 1 year.


JAMA | 2014

Transcatheter Aortic Valve Implantation in Failed Bioprosthetic Surgical Valves

Danny Dvir; John G. Webb; Sabine Bleiziffer; M. Pasic; Ron Waksman; Susheel Kodali; Marco Barbanti; Azeem Latib; Ulrich Schaefer; Josep Rodés-Cabau; Hendrik Treede; Nicolo Piazza; David Hildick-Smith; Dominique Himbert; Thomas Walther; Christian Hengstenberg; Henrik Nissen; Raffi Bekeredjian; Patrizia Presbitero; Enrico Ferrari; Amit Segev; Arend de Weger; Stephan Windecker; Neil Moat; Massimo Napodano; M. Wilbring; Alfredo Cerillo; Stephen Brecker; Didier Tchetche; Thierry Lefèvre

IMPORTANCE Owing to a considerable shift toward bioprosthesis implantation rather than mechanical valves, it is expected that patients will increasingly present with degenerated bioprostheses in the next few years. Transcatheter aortic valve-in-valve implantation is a less invasive approach for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed. OBJECTIVE To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves. DESIGN, SETTING, AND PARTICIPANTS Correlates for survival were evaluated using a multinational valve-in-valve registry that included 459 patients with degenerated bioprosthetic valves undergoing valve-in-valve implantation between 2007 and May 2013 in 55 centers (mean age, 77.6 [SD, 9.8] years; 56% men; median Society of Thoracic Surgeons mortality prediction score, 9.8% [interquartile range, 7.7%-16%]). Surgical valves were classified as small (≤21 mm; 29.7%), intermediate (>21 and <25 mm; 39.3%), and large (≥25 mm; 31%). Implanted devices included both balloon- and self-expandable valves. MAIN OUTCOMES AND MEASURES Survival, stroke, and New York Heart Association functional class. RESULTS Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83.2% (95% CI, 80.8%-84.7%; 62 death events; 228 survivors). Patients in the stenosis group had worse 1-year survival (76.6%; 95% CI, 68.9%-83.1%; 34 deaths; 86 survivors) in comparison with the regurgitation group (91.2%; 95% CI, 85.7%-96.7%; 10 deaths; 76 survivors) and the combined group (83.9%; 95% CI, 76.8%-91%; 18 deaths; 66 survivors) (P = .01). Similarly, patients with small valves had worse 1-year survival (74.8% [95% CI, 66.2%-83.4%]; 27 deaths; 57 survivors) vs with intermediate-sized valves (81.8%; 95% CI, 75.3%-88.3%; 26 deaths; 92 survivors) and with large valves (93.3%; 95% CI, 85.7%-96.7%; 7 deaths; 73 survivors) (P = .001). Factors associated with mortality within 1 year included having small surgical bioprosthesis (≤21 mm; hazard ratio, 2.04; 95% CI, 1.14-3.67; P = .02) and baseline stenosis (vs regurgitation; hazard ratio, 3.07; 95% CI, 1.33-7.08; P = .008). CONCLUSIONS AND RELEVANCE In this registry of patients who underwent transcatheter valve-in-valve implantation for degenerated bioprosthetic aortic valves, overall 1-year survival was 83.2%. Survival was lower among patients with small bioprostheses and those with predominant surgical valve stenosis.


European Heart Journal | 2012

Transcatheter aortic valve implantation: 3-year outcomes of self-expanding CoreValve prosthesis

Gian Paolo Ussia; Marco Barbanti; Anna Sonia Petronio; Giuseppe Tarantini; Federica Ettori; Antonio Colombo; Roberto Violini; Angelo Ramondo; Gennaro Santoro; Silvio Klugmann; Francesco Bedogni; Francesco Maisano; Antonio Marzocchi; Arnaldo Poli; Marco De Carlo; Massimo Napodano; Claudia Fiorina; Federico De Marco; David Antoniucci; Emanuela de Cillis; Davide Capodanno; Corrado Tamburino

AIMS The paucity of evidences about the long-term durability of currently available transcatheter prostheses is one of the main issues of transcatheter aortic valve implantation (TAVI). We sought to assess 3-year clinical and echocardiographic outcomes of patients undergoing TAVI with the third generation CoreValve prosthesis (Medtronic Incorporation, MN, USA). METHODS AND RESULTS From the Italian CoreValve registry, 181 who underwent TAVI from June 2007 to August 2008 and eligible for 3-year follow-up were analysed. All outcomes were defined according to the Valve Academic Research Consortium. All-cause mortality at 1, 2, and 3 years was 23.6, 30.3, and 34.8%, respectively. Cardiovascular death at 1, 2, and 3 years was 11.2, 12.1, and 13.5%, respectively. The actuarial survival free from a composite of death, major stroke, myocardial infarction, and life-threatening bleeding was 69.6% at 1 year, 63.5% at 2 years, and 59.7% at 3 years. Patients with renal insufficiency had a higher mortality at 3-year follow-up (49.0 vs. 29.2%, P = 0.007); moreover, patients experiencing post-procedural major or life-threatening bleeding had a higher rate of mortality already seen at 30 days (21.6 vs. 2.8%; P < 0.001) and this result was sustained at 3-year follow-up (62.2 vs. 27.7%; P < 0.001). Mean pressure gradients decreased from 52.2 ± 18.1 mmHg (pre-TAVI) to 10.3 ± 3.1 mmHg (1-year post-TAVI) (P < 0.001); aortic valve area increased from 0.6 ± 0.2 cm(2) (pre-TAVI) to 1.8 ± 0.4 cm(2) (1-year post-TAVI); these results remained stable over the 3 years of follow-up. Paravalvular leak was observed in the majority of patients. There were no cases of progression to moderate or severe regurgitation. No cases of structural valve deterioration were observed. CONCLUSION This multicentre study demonstrates that TAVI with the 18-Fr CoreValve ReValving System is associated with sustained clinical and functional cardiovascular benefits in high-risk patients with symptomatic aortic stenosis up to 3-year follow-up. Non-cardiac causes accounted for the majority of deaths at follow-up.


Circulation-cardiovascular Interventions | 2010

Safety and Efficacy of the Subclavian Approach for Transcatheter Aortic Valve Implantation With the CoreValve Revalving System

Anna Sonia Petronio; Marco De Carlo; Francesco Bedogni; Antonio Marzocchi; Silvio Klugmann; Francesco Maisano; Angelo Ramondo; Gian Paolo Ussia; Federica Ettori; Arnaldo Poli; Nedy Brambilla; Francesco Saia; Federico De Marco; Antonio Colombo

Background—Transcatheter aortic valve implantation (TAVI) is a new option for patients with severe aortic stenosis at high surgical risk. The standard retrograde approach through the femoral artery is contraindicated in case of unfavorable iliofemoral anatomy or extensive disease. In these patients, a trans-subclavian approach may be feasible. Methods and Results—Between June 2007 and July 2009, TAVI with the CoreValve bioprosthesis (Medtronic, Minneapolis, Minn) was performed in 514 consecutive patients at 13 Italian hospitals, using the subclavian approach in 54 cases. The median logistic EuroSCORE was significantly higher in the subclavian (19.4; interquartile range, 12.5 to 29.8) versus femoral group (25.3; interquartile range, 15.1 to 36.6) (P=0.03), as well as the rate of comorbidities. Procedural success was obtained in 100% versus 98.4% of the subclavian versus femoral groups, respectively (P=0.62), with intraprocedural mortality of 0% versus 0.9% (P=1.00). The most common in-hospital complications were a new left bundle-branch block (22.4%) and the need for pacemaker (16.3%). No specific complications for the subclavian access (vessel rupture, vertebral or internal mammary ischemia) were reported. The learning curve for the subclavian approach led to a wider use of local anesthesia. Thirty-day mortality was 0% versus 6.1% in the subclavian versus femoral groups, respectively (P=0.13). Six-month mortality rate was 9.4% versus 15.8% (P=0.44), whereas valve-related adverse events were 13.6% versus 13.9% (P=0.79). Conclusions—TAVI through the subclavian approach appeared feasible and safe, with excellent procedural success and low in-hospital complication rates. This new technique allows patients with contraindications to the femoral approach to be treated with TAVI.


Journal of the American College of Cardiology | 2013

Transcatheter Aortic Valve Implantation for Pure Severe Native Aortic Valve Regurgitation

David Roy; Ulrich Schaefer; Victor Guetta; David Hildick-Smith; Helge Möllmann; Nicholas Dumonteil; Thomas Modine; Johan Bosmans; Anna Sonia Petronio; Neil Moat; Axel Linke; Cesar Moris; Didier Champagnac; Radosław Parma; Andrzej Ochała; Diego Medvedofsky; Tiffany Patterson; Felix Woitek; Marjan Jahangiri; Jean-Claude Laborde; Stephen Brecker

OBJECTIVES This study sought to collect data and evaluate the anecdotal use of transcatheter aortic valve implantation (TAVI) in pure native aortic valve regurgitation (NAVR) for patients who were deemed surgically inoperable BACKGROUND Data and experience with TAVI in the treatment of patients with pure severe NAVR are limited. METHODS Data on baseline patient characteristics, device and procedure parameters, echocardiographic parameters, and outcomes up to July 2012 were collected retrospectively from 14 centers that have performed TAVI for NAVR. RESULTS A total of 43 patients underwent TAVI with the CoreValve prosthesis (Medtronic, Minneapolis, Minnesota) at 14 centers (mean age, 75.3 ± 8.8 years; 53% female; mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation), 26.9 ± 17.9%; and mean Society of Thoracic Surgeons score, 10.2 ± 5.3%). All patients had severe NAVR on echocardiography without aortic stenosis and 17 patients (39.5%) had the degree of aortic valvular calcification documented on CT or echocardiography. Vascular access was transfemoral (n = 35), subclavian (n = 4), direct aortic (n = 3), and carotid (n = 1). Implantation of a TAVI was performed in 42 patients (97.7%), and 8 patients (18.6%) required a second valve during the index procedure for residual aortic regurgitation. In all patients requiring second valves, valvular calcification was absent (p = 0.014). Post-procedure aortic regurgitation grade I or lower was present in 34 patients (79.1%). At 30 days, the major stroke incidence was 4.7%, and the all-cause mortality rate was 9.3%. At 12 months, the all-cause mortality rate was 21.4% (6 of 28 patients). CONCLUSIONS This registry analysis demonstrates the feasibility and potential procedure difficulties when using TAVI for severe NAVR. Acceptable results may be achieved in carefully selected patients who are deemed too high risk for conventional surgery, but the possibility of requiring 2 valves and leaving residual aortic regurgitation remain important considerations.


Circulation | 2003

Mechanical Prevention of Distal Embolization During Primary Angioplasty: Safety, Feasibility, and Impact on Myocardial Reperfusion

Ugo Limbruno; Andrea Micheli; Marco De Carlo; Giovanni Amoroso; Roberta Rossini; C Palagi; Vitantonio Di Bello; Anna Sonia Petronio; Gabriella Fontanini; Mario Mariani

Background—Effective myocardial reperfusion after primary percutaneous coronary intervention (PCI) may be limited by distal embolization. We tested the safety, feasibility, and efficacy of the FilterWire-Ex (FW), a distal embolic protection device, as an adjunct to primary PCI. Methods and Results—Fifty-three consecutive patients undergoing primary PCI with FW protection were compared with a matched control group treated by primary PCI alone. Successful FW positioning was obtained in 47 patients (89%) without complications. Histological analysis of the content of the last 13 filters showed multiple embolic debris in all cases. FW use was associated with lower postinterventional corrected TIMI frame count (22±14 versus 31±19; P =0.005) and higher occurrence of grade 3 myocardial blush (66% versus 36%; P =0.006) and early ST-segment elevation resolution (80% versus 54%; P= 0.006). At multivariate analysis, FW use was the only independent predictor of early ST-segment elevation resolution and of grade 3 myocardial blush. FW patients showed lower peak creatine kinase-MB release (236±172 versus 333±219 ng/mL; P =0.013) and greater improvement at 30 days in left ventricular wall motion score index (−0.30±0.19 versus −0.18±0.26; P= 0.008) and ejection fraction (+7±4% versus +4±7%; P =0.012). Conclusions—FW use during primary PCI is feasible and safe. Distal embolization prevention appears to exert a beneficial effect on markers of myocardial reperfusion and on left ventricular function improvement at 30 days.


European Heart Journal | 2003

Effects of abciximab on microvascular integrity and left ventricular functional recovery in patients with acute infarction treated by primary coronary angioplasty.

Anna Sonia Petronio; Daniele Rovai; Giuseppe Musumeci; Roberto Baglini; Carmela Nardi; Ugo Limbruno; C Palagi; Duccio Volterrani; Mario Mariani

AIM To investigate the effect of abciximab on microvascular integrity and left ventricular (LV) functional recovery in patients with acute myocardial infarction (MI) treated by primary coronary angioplasty (PTCA). METHODS AND RESULTS Thirty-one patients (27 males; age 39-76 years) with first, acute MI (<6 h after onset) were randomized to receive either abciximab+primary PTCA (n=17) or primary PTCA alone (n=14). Baseline characteristics of the two groups were similar. Myocardial reperfusion was studied shortly after PTCA by corrected TIMI frame count (cTFC) and intracoronary myocardial contrast echocardiography (MCE), after 48 h by intravenous MCE using intermittent, harmonic power Doppler, and after 1 month by intravenous MCE and 99 mTc-tetrofosmin SPECT. The patients treated with abciximab showed a shorter cTFC (23+/-4 vs 30+/-9 frames; P<0.05), a more preserved microvascular integrity shortly after PTCA (77% vs 55%; P<0.01), after 48 h (86% vs 50%; P<0.005) and at 1-month follow-up (86% vs 54% by MCE, P<0.001, and 68% vs 60% by SPECT, P<0.005) than patients treated with PTCA alone. Abciximab patients also showed a better recovery of LV function, as demonstrated by greater reduction in wall motion score index (1.4+/-0.3 vs 1.5+/-0.2; P<0.05) and increase in LV ejection fraction (53+/-7% vs 48+/-5%; P<0.001). CONCLUSIONS Abciximab improves microvascular perfusion and LV functional recovery in primary PTCA.


Jacc-cardiovascular Interventions | 2015

5-Year Outcomes After Transcatheter Aortic Valve Implantation With CoreValve Prosthesis.

Marco Barbanti; Anna Sonia Petronio; Federica Ettori; Azeem Latib; Francesco Bedogni; Federico De Marco; Arnaldo Poli; Carla Boschetti; Marco De Carlo; Claudia Fiorina; Antonio Colombo; Nedy Brambilla; Giuseppe Bruschi; Paola Martina; Claudia Pandolfi; Cristina Giannini; Salvatore Curello; Carmelo Sgroi; Simona Gulino; Martina Patanè; Yohei Ohno; Claudia Tamburino; Guilherme F. Attizzani; Sebastiano Immè; Alessandra Gentili; Corrado Tamburino

OBJECTIVES The purpose of this analysis was to assess 5-year outcomes of transcatheter aortic valve implantation (TAVI) using the current technology of the self-expanding CoreValve prosthesis (Medtronic Inc., Minneapolis, Minnesota). BACKGROUND There is a paucity of evidence on long-term durability of currently available transcatheter heart valves. METHODS Starting in June 2007, all consecutive patients with severe aortic stenosis undergoing TAVI with the third-generation 18-F CoreValve device in 8 Italian centers were prospectively included in the ClinicalService Project. For the purposes of this study, we included only consecutive patients with 5-year follow-up data available (n = 353) treated from June 2007 to August 2009. All outcomes were reported according to VARC (Valve Academic Research Consortium)-1 criteria. RESULTS All-cause mortality rates at 1, 2, 3, 4, and 5 years were 21%, 29%, 38%, 48%, and 55.0%, respectively. Cardiovascular mortality rates at 1, 2, 3, 4, and 5 years were 10%, 14%, 19%, 23%, and 28.0%, respectively. The overall neurological event rate at 5 years was 7.5%, of which more than two-thirds occurred early after the procedure. During follow-up, there were 241 rehospitalizations for cardiovascular reasons in 164 (46%) patients. Among all rehospitalizations, acute heart failure was the most frequently reported (42.7%), followed by requirement of permanent pacemaker implantation (17.4%). On echocardiography, mean transaortic gradients decreased from 55.6 ± 16.8 mm Hg (pre-TAVI) to 12.8 ± 10.9 mm Hg (5-year post-TAVI) (p < 0.001). Late prosthesis failure occurred in 5 cases (1.4%); among these, redo TAVI was successfully carried out in 2 patients (0.6%) presenting with symptomatic prosthesis restenosis. The remaining 3 cases of prosthesis failure did not undergo further invasive interventions. Ten patients (2.8%) showed late mild stenosis with a mean transaortic gradient ranging from 20 to 40 mm Hg. No other cases of structural or nonstructural valvular deterioration were observed. Valve thrombosis or late valve embolization were not reported. CONCLUSIONS TAVI with the currently adopted CoreValve generation was associated with sustained clinical outcomes up to 5-year follow-up, with a low rate (1.4%) of significant prosthetic valve degeneration. The procedure appears to be an adequate and lasting resolution of aortic stenosis in selected high-risk patients.


Circulation | 2013

Clinical impact of persistent left bundle-branch block after transcatheter aortic valve implantation with CoreValve revalving system

Luca Testa; Azeem Latib; Federico De Marco; Marco De Carlo; Mauro Agnifili; Roberto Latini; Anna Sonia Petronio; Federica Ettori; Arnaldo Poli; Stefano De Servi; Angelo Ramondo; Massimo Napodano; S. Klugmann; Gian Paolo Ussia; Corrado Tamburino; Nedy Brambilla; Antonio Colombo; Francesco Bedogni

Background— Conduction disturbances are relatively common after transcatheter aortic valve implantation. Previous data demonstrated an adverse impact of persistent left bundle-branch block (LBBB) after surgical aortic valve replacement. It is unclear whether new-onset LBBB may also impact the prognosis of patients after transcatheter aortic valve implantation. Methods and Results— Among 1060 patients treated with a CoreValve Revalving System transcatheter aortic valve implantation between October 2007 and April 2011 in high-volume centers in Italy, we analyzed those without LBBB or pacemaker at admission (879 patients [82.9%]). We further excluded those who underwent permanent pacemaker implantation within 48 hours after the procedure (61 patients [7%]), for a final study population of 818 patients. Among them, 224 patients (group A; 27.4%) developed a persistent LBBB and the remaining 594 (group B; 72.6%) did not. Clinical characteristics were similar between groups. A low implantation was significantly more frequent in group A (15% versus 9.8%, P=0.02). No patients were censored before 1 year (median follow-up period 438 days, interquartile range 174–798 days). Survival analyses and inherent log-rank tests showed that LBBB was not associated with higher all-cause mortality, cardiac mortality, or hospitalization for heart failure at 30 days or 1 year. At 30 days, but not at 1 year, group A had a significantly higher rate of pacemaker implantation. Conclusions— In this registry of high-volume centers, persistent LBBB after CoreValve Revalving System transcatheter aortic valve implantation showed no effect on hard end points. On the other hand, LBBB was associated with a higher short-term rate of pacemaker implantation.

Collaboration


Dive into the Anna Sonia Petronio's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Francesco Bedogni

Vita-Salute San Raffaele University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Antonio Colombo

Vita-Salute San Raffaele University

View shared research outputs
Researchain Logo
Decentralizing Knowledge