Jacc-cardiovascular Interventions | 2008
Nicolo Piazza; Yoshinobu Onuma; Emile Jesserun; Peter Paul Kint; Anne-Marie Maugenest; Robert H. Anderson; Peter de Jaegere; Patrick W. Serruys
OBJECTIVES In this retrospective study, we examined the incidence of post-procedural conduction abnormalities and the need for pacing in patients undergoing percutaneous implantation of the aortic valve. BACKGROUND Safety and feasibility studies have suggested anecdotally the occurrence of conduction abnormalities and requirements for pacing after percutaneous implantation of the aortic valve. METHODS We examined the standard 12-lead electrocardiograms (ECGs) of 40 consecutive patients in whom a CoreValve Revalving System (CoreValve, Paris, France) was implanted between November 2005 and March 2008. We examined the 12-lead ECG before treatment, after treatment, and at 1-month follow-up. We documented the requirements for temporary or permanent pacemaking. RESULTS The mean age of patients was 82 +/- 7 years. Post-procedural mortality at 72 h was 0%. There was a significant increase in the frequency of left bundle branch block (LBBB) after percutaneous aortic valve replacement (15% before treatment vs. 55% after treatment, p = 0.001). Although the incidence of LBBB had decreased after follow-up of 1 month, it did not reach statistical significance, with the proportion decreasing from 55% to 48% (p = 0.63). The only 2 patients with pre-treatment right bundle branch block became dependent on temporary pacing immediately after valve implantation and subsequently needed permanent pacing. A temporary and permanent pacemaker was required in 20% and 18% of patients, respectively. CONCLUSIONS In this study, there was a significant increase in the frequency of LBBB after percutaneous insertion of the aortic valvar prosthesis. Patients with pre-existing right bundle branch block may be at risk for the development of complete heart block and subsequent need for pacing.
European Heart Journal | 2011
Rutger-Jan Nuis; Nicolas M. Van Mieghem; Carl Schultz; Apostolos Tzikas; Robert M.A. van der Boon; Anne-Marie Maugenest; Jin Cheng; Nicolo Piazza; Ron T. van Domburg; Patrick W. Serruys; Peter de Jaegere
AIMS New-onset left bundle branch block (LBBB) and complete atrioventricular block (AV3B) frequently occur following transcatheter aortic valve implantation (TAVI). We sought to determine the timing and potential mechanisms of new conduction abnormalities (CAs) during TAVI, using the Medtronic CoreValve System (MCS). METHODS AND RESULTS Sixty-five consecutive patients underwent TAVI with continuous 12-lead ECG analysis. New CAs were defined by the occurrence of LBBB, RBBB, and/or AV3B after the following pre-defined time points: (i) crossing of valve with stiff wire, (ii) positioning of balloon catheter in the aortic annulus, (iii) balloon valvuloplasty, (iv) positioning of MCS in the left ventricular outflow tract (LVOT), (v) expansion of MCS, (vi) removal of all catheters. A new CA occurred during TAVI in 48 patients (74%) and after TAVI in 5 (8%). Of the 48 patients with procedural CAs, a single new CA occurred in 43 patients (90%) and two types of CAs in 5 (10%). A new LBBB was seen in 40 patients (83%), AV3B in 9 (19%), and RBBB in 4 (8%). The new CA first occurred-in descending order of frequency-after balloon valvuloplasty in 22 patients (46%), MCS expansion in 14 (29%), MCS positioning in 6 (12%), positioning of balloon catheter in 3 (6%), wire-crossing of aortic valve in 2 (4%), and after catheter removal in 1 patient (2%). Patients who developed a new CA during balloon valvuloplasty had a significantly higher balloon/annulus ratio than those who did not (1.10±0.10 vs. 1.03±0.11, P=0.030). No such relationship was found with the valve/annulus ratio. CONCLUSION Transcatheter aortic valve implantation with the MCS was associated with new CAs in 82% of which more than half occurred before the actual valve implantation. It remains to be elucidated by dedicated studies whether new CAs can be reduced by appropriate balloon sizing-a precept that also holds for valve size given the observed directional signal of the valve size/aortic annulus ratio.
Eurointervention | 2018
N.M. Van Mieghem; Joost Daemen; C.A. den Uil; O. Dur; L. Joziasse; Anne-Marie Maugenest; K. Fitzgerald; C. Parker; P. Muller; R.J.M. van Geuns
The HeartMate PHP (percutaneous heart pump) is a second-generation transcatheter axial flow circulatory support system. The collapsible catheter pump is inserted through a 14 Fr sheath, deployed across the aortic valve expanding to 24 Fr and able to deliver up to 5 L/min blood flow at minimum haemolytic risk. As such, this device may be a valuable adjunct to percutaneous coronary intervention (PCI) of challenging lesions in high-risk patients or treatment of cardiogenic shock. This technical report discusses: (i) the HeartMate PHP concept, (ii) the implantation technique, (iii) the haemodynamic performance in an in vitro cardiovascular flow testing set-up, and (iv) preliminary clinical experience. An update on the device, produced by St. Jude Medical/Abbott Laboratories, can be found in the Appendix.
Europace | 2014
P. M. van Dam; K. Proniewska; Anne-Marie Maugenest; N.M. Van Mieghem; A. C. Maan; P. de Jaegere; Nico Bruining
AIMS Conventional electrocardiogram (ECG)-based diagnosis of left bundle branch block (LBBB) in patients with left ventricular hypertrophy (LVH) is ambiguous. Left ventricular hypertrophy is often seen in patients with severe aortic stenosis in which a transcatheter aortic valve implantation (TAVI) frequently results in a LBBB due to the mechanical interaction of the artificial valve and the conduction system. In this feasibility study, we propose and evaluate the sensitivity of a new electrocardiographic imaging tool; the cardiac isochrone positioning system (CIPS), visualizing the cardiac activation to detect interventricular conduction patterns pre- and post-TAVI. METHODS AND RESULTS The CIPS translates standard 12-lead ECG into ventricular isochrones, representing the activation sequence. It requires a patient-specific model integrating heart, lungs, and other thoracic structures derived from multi-slice computed tomography. The fastest route-based algorithm was used to estimate the activation isochrones and the results were compared with standard ECG analysis. In 10 patients the CIPS was used to analyse 20 ECGs, 10 pre- and 10 post-TAVI. In 11 cases the CIPS results were in agreement with the ECG-based diagnosis. In two cases there was partial agreement and in seven cases there was disagreement. In four of these cases, the clinical history of the patients favoured interpretation as assessed by CIPS, for the remaining three, it is unknown which method correctly classified the activation. CONCLUSION This feasibility study applying the CIPS shows promising results to classify conduction disorders originating from the left anterior or posterior ventricular wall, or the septum. The visualization of the activation isochrones as well as ventricular model-derived features might support TAVI procedures and the therapy selection afterwards.
Eurointervention | 2017
C.A. den Uil; Joost Daemen; Mattie J. Lenzen; Anne-Marie Maugenest; L. Joziasse; R.J.M. van Geuns; N.M. Van Mieghem
AIMS Our aim was to test the feasibility and safety of the transfemoral PulseCath iVAC 2L (PulseCath, Amsterdam, The Netherlands). METHODS AND RESULTS Circulatory support devices are helpful adjunctive tools to perform high-risk percutaneous coronary interventions (PCI). The PulseCath iVAC 2L is a novel pulsatile circulatory support system capable of generating output of up to 2 L/min. We performed a prospective clinical pilot study enrolling 14 patients who underwent high-risk PCI under protection with the iVAC 2L. Median age was 74 (56-84) years. Implantation of the iVAC 2L was successful in 13 (93%) patients. Median device flow was 1.4 (1.1-2.0) L/min. Total support time was 67 (23-149) minutes. The use of iVAC 2L support was associated with a better mean arterial pressure and cardiac output during the procedure. Angiographic success was 100%. There was one major procedural complication related to the 19 Fr access sheath. There were no major adverse events at three-month follow-up. CONCLUSIONS Circulatory support with the iVAC 2L device is feasible and safe in patients undergoing high-risk PCI.
International Journal of Cardiovascular Imaging | 2016
Ramón Rodríguez-Olivares; Nahid El Faquir; Zouhair Rahhab; Anne-Marie Maugenest; Nicolas M. Van Mieghem; Carl Schultz; Guenter Lauritsch; Peter de Jaegere
To study the determinants of image quality of rotational angiography using dedicated research prototype software for motion compensation without rapid ventricular pacing after the implantation of four commercially available catheter-based valves. Prospective observational study including 179 consecutive patients who underwent transcatheter aortic valve implantation (TAVI) with either the Medtronic CoreValve (MCS), Edward-SAPIEN Valve (ESV), Boston Sadra Lotus (BSL) or Saint-Jude Portico Valve (SJP) in whom rotational angiography (R-angio) with motion compensation 3D image reconstruction was performed. Image quality was evaluated from grade 1 (excellent image quality) to grade 5 (strongly degraded). Distinction was made between good (grades 1, 2) and poor image quality (grades 3–5). Clinical (gender, body mass index, Agatston score, heart rate and rhythm, artifacts), procedural (valve type) and technical variables (isocentricity) were related with the image quality assessment. Image quality was good in 128 (72 %) and poor in 51 (28 %) patients. By univariable analysis only valve type (BSL) and the presence of an artefact negatively affected image quality. By multivariate analysis (in which BMI was forced into the model) BSL valve (Odds 3.5, 95 % CI [1.3–9.6], p = 0.02), presence of an artifact (Odds 2.5, 95 % CI [1.2–5.4], p = 0.02) and BMI (Odds 1.1, 95 % CI [1.0–1.2], p = 0.04) were independent predictors of poor image quality. Rotational angiography with motion compensation 3D image reconstruction using a dedicated research prototype software offers good image quality for the evaluation of frame geometry after TAVI in the majority of patients. Valve type, presence of artifacts and higher BMI negatively affect image quality.
Catheterization and Cardiovascular Interventions | 2018
Lennart van Gils; Herbert Kroon; Joost Daemen; Claire Ren; Anne-Marie Maugenest; Marguerite E.I. Schipper; Peter de Jaegere; Nicolas M. Van Mieghem
To evaluate the value of left vertebral artery filter protection in addition to the current filter‐based embolic protection technology to achieve complete cerebral protection during TAVR.
Europace | 2018
Lennart van Gils; Sara Baart; Herbert Kroon; Zouhair Rahhab; Nahid El Faquir; Ramón Rodriguez Olivares; Yaar Aga; Anne-Marie Maugenest; Dominic A.M.J. Theuns; Eric Boersma; Tamas Szili Torok M.D.; Peter de Jaegere; Nicolas M. Van Mieghem
Aims To correlate dynamics in electrical conduction after transcatheter aortic valve implantation (TAVI) with need for permanent pacemaker implantation (PPM) and assess implications for early discharge. Methods and results Daily electrocardiograms after TAVI were analysed for rhythm and conduction times and were correlated with PPM. Transcatheter aortic valve implantation was performed in 291 consecutive patients with three contemporary transcatheter heart valve designs: Medtronic CoreValve (n = 111), Edwards Sapien XT (n = 29) and Sapien 3 (n = 72), and Boston Lotus (n = 79). We considered two cohorts: (A) Patients with normal baseline conduction; and (B) patients with pre-existent conduction disturbances. Based on QRS dynamics, three patterns were discerned: stable normal QRS duration, transient QRS prolongation, and persistent QRS prolongation. In Cohort B, QRS dynamics did not correlate with PPM. In contrast, in Cohort A, QRS dynamics and PPM appeared highly correlated. Neither patients with stable normal QRS duration (0/47), nor patients with transient QRS prolongation required PPM (0/26). All PPMs occurred in patients with persistent QRS prolongation until discharge (27/85). Persistent QRS prolongation was typically seen with Lotus and CoreValve, whereas stable normal QRS duration was typically seen with Sapien XT and Sapien 3. Conclusion Three distinct patterns of QRS dynamics can be discerned after TAVI and their predictive probabilities for PPM strongly relate to the baseline conduction status. Patients with normal conduction at baseline and stable QRS duration after TAVI are potentially eligible for early discharge.
Jacc-cardiovascular Imaging | 2017
Nahid El Faquir; Ben Ren; Marguerite Faure; Marjo de Ronde; Patrick Geeve; Anne-Marie Maugenest; Isabella Kardys; Marcel L. Geleijnse; Peter de Jaegere; Ricardo P.J. Budde; Nicolas M. Van Mieghem
Excellent outcome after transcatheter aortic valve replacement (TAVR) is demonstrated by preserved transcatheter heart valve (THV) function at 2 to 5 years and intact structural integrity at 2 years [(1,2)][1]. Hypoattenuated leaflet thickening (HALT) appears in up to 40% by multislice computed
Eurointervention | 2008
Peter de Jaegere; Lukas C. van Dijk; Marc R.H.M. van Sambeek; Arie-Pieter Kappetein; Francisco Javier Orellana Ramos; Anne-Marie Maugenest; Marjo De Ronde-Tilmans; Patrick W. Serruys