Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Anne Polge is active.

Publication


Featured researches published by Anne Polge.


American Journal of Cardiology | 1999

Relation of minor cardiac troponin I elevation to late cardiac events after uncomplicated elective successful percutaneous transluminal coronary angioplasty for angina pectoris

Jean-Pierre Bertinchant; Anne Polge; Bertrand Ledermann; Loı̈c Genet; Pascale Fabbro-Peray; Franck Raczka; Jérôme Brunet; Sophie Poirey; Olivier Wittenberg; Isabelle Pernel; Jacques Nigond

There is little information about the relation between mild cardiac troponin I (cTn-I) increase after coronary interventions and late outcome. We therefore focused on the long-term outcome and the clinical, morphologic, and procedural correlates of elevation of cTn-I compared with cardiac troponin T, creatine kinase (CK), CK-MB activity and mass, and myoglobin in 105 patients with successful elective percutaneous transluminal coronary angioplasty (PTCA) for stable or unstable angina. Patients with myocardial infarction and those with unstable angina who had a detectable increase in serum markers before PTCA were excluded. Markers were measured before and after the procedure and for 2 days. Patients were followed up to record recurrent angina, myocardial infarction, cardiac death, repeat PTCA, or elective coronary artery bypass graft surgery. Procedure success was achieved in all cases. Elevation in cTn-I (> or =0.1 microg/L) was observed in 23 of 105 patients (22%) (median peak: 0.25 microg/L); 18% had cardiac troponin T (cTn-T) release (> or = 0.1 microg/L, median peak 0.21); 11.4% CK-MB mass (> or =5 microg/L), and 7.6% myoglobin (> or =90 microg/L) release. Five and 2 patients had elevated CK and CK-MB activity, respectively. Fourteen of 18 patients with cTn-T elevation had a corresponding elevation in cTn-I (kappa 0.68; p = 0.001). Patients positive for cTn-I had more unstable angina (p = 0.042) and heparin before PTCA (p = 0.046), and had longest total time (p = 0.004) and single inflation (p = 0.01). By multivariate logistic regression, predictors of postprocedure cTnI elevation were maximum time of each inflation (odds ratio 9.2; p = 0.0012), type B lesions (odds ratio 6.6; p = 0.013), unstable angina (p = 0.041), and age > or =60 years (p = 0.032). Clinical follow-up was available in 103 patients (98%) (mean 19+/-10 months). Kaplan-Meier survival analysis showed that cTn-I elevation was not an important correlate of cardiac events (p = 0.34, by log-rank analysis). The incidence of recurrent angina, myocardial infarction, cardiac death, and repeat revascularization after 12 months was not different in patients positive or negative for cTn-I. We conclude that cTn-I elevation after successful PTCA is not associated with significantly worse late clinical outcome. Levels of cTn-I allow a much higher diagnostic accuracy in detecting minor myocardial injury after PTCA compared with other markers, but there is no association with periprocedural myocardial cell injury and late outcome when cTn-I and other markers are considered.


Clinica Chimica Acta | 2000

Comparison of the diagnostic value of cardiac troponin I and T determinations for detecting early myocardial damage and the relationship with histological findings after isoprenaline-induced cardiac injury in rats

Jean-Pierre Bertinchant; Emmanuelle Robert; Anne Polge; C Marty-Double; Pascale Fabbro-Peray; Sophie Poirey; Guy Aya; Jean-Marie Juan; Bertrand Ledermann; J.-E. de La Coussaye; Michel Dauzat

Cardiac troponins I (cTnI) and T (cTnT) have been shown to be highly sensitive and specific markers of myocardial cell injury. The purpose of this study was to investigate the diagnostic value of cTnI and cTnT with regard to creatine kinase (CK) and lactate dehydrogenase (LD) and to determine whether they can be used for early diagnosis of myocardial damage in rats, and to examine the relationship between cTnl and cTnT release with histological examinations, using isoprenaline-induced cardiac muscle damage as an experimental model in the rat. Eighteen Wistar rats per group were treated with a single dose of either isoprenaline (iso) or with normal saline as a control group. The anti-cTnI and cTnT monoclonal antibodies (mAbs) employed in the cTnI (Access) and cTnT (Elecsys) assays cross-react with cTnI and cTnT of the rat. A highly significant rise of cTnl or cTnT was found already 2 h after iso. The time-courses of cTnI and cTnT were monophasic in form. The highest cTnI (mean+/-S.D., 1.1+/-2.3 ng/ml) and cTnT (mean+/-S.D. 3.6+/-30 ng/ml) were found 4 h after iso. cTnI and cTnT significantly increased in iso-treated rats in comparison with controls whether the differences between 2-, 4- and 6-h levels and basal levels were considered or not. The areas under cTnl and cTnT curves (AUC) (0-6 h) and the maximal cTnI and cTnT (0-6 h) after iso were significantly different from the controls. For CK and LD, no elevation in comparison with controls could be detected (except a trend for LD whether or not the difference between 6-h levels and basal levels were considered (P=0.08) and for LD AUC (0-6 h) (P=0. 059)). Correlations between maximal cTnI and cTnT and AUC were 0.69 (P=0.0001) and 0.60 (P=0.0066), respectively. Histological examinations of iso-treated rats revealed acute focal or multifocal myofibrillar degeneration of the myocardial tissue in ten out of 14 rats and showed the earliest alterations 4 h after iso in one treated rat. Only four of the controls exhibited evidence of mild changes and slight mononuclear cell infiltration. cTnl and cTnT peak values to at least 0.35 and 1.3 ng/ml, respectively, were necessary to detect histological myocardial cell injury after iso. cTnI and cTnT were found to be early markers for diagnosing iso-induced myocardial damage in comparison with CK and LD. Elevations of cTnI and cTnT appeared to relate to the severity of histologic changes after myocardial injury. Although there was a difference in the absolute concentration of results between cTnI and cTnT assays, due to a lack of standardization and heterogeneity in the cross-reactivities of mAbs to various troponin I and T forms, cTnI and cTnT can be used as easily measurable target parameters for detection of cardiotoxic and/or cardiodegenerative effects in rats.


Clinica Chimica Acta | 2003

Evaluation of cardiac troponin I and T levels as markers of myocardial damage in doxorubicin-induced cardiomyopathy rats, and their relationship with echocardiographic and histological findings

Jean-Pierre Bertinchant; Anne Polge; Jean-Marie Juan; Marie-Claire Oliva-Lauraire; I Giuliani; C Marty-Double; J.Y Burdy; Pascale Fabbro-Peray; Michel Laprade; Jean-Pierre Bali; C Granier; J.-E. de La Coussaye; Michel Dauzat

BACKGROUND Cardiac troponins I (cTnI) and T (cTnT) have been shown to be highly sensitive and specific markers of myocardial cell injury. We investigated the diagnostic value of cTnI and cTnT for the diagnosis of myocardial damage in a rat model of doxorubicin (DOX)-induced cardiomyopathy, and we examined the relationship between serial cTnI and cTnT with the development of cardiac disorders monitored by echocardiography and histological examinations in this model. METHODS Thirty-five Wistar rats were given 1.5 mg/kg DOX, i.v., weekly for up to 8 weeks for a total cumulative dose of 12 mg/kg BW. Ten rats received saline as a control group. cTnI was measured with Access(R) (ng/ml) and a research immunoassay (pg/ml), and compared with cTnT, CK-MB mass and CK. By using transthoracic echocardiography, anterior and posterior wall thickness, LV diameters and LV fractional shortening (FS) were measured in all rats before DOX or saline, and at weeks 6 and 9 after treatment in all surviving rats. Histology was performed in DOX-rats at 6 and 9 weeks after the last DOX dose and in all controls. RESULTS Eighteen of the DOX rats died prematurely of general toxicity during the 9-week period. End-diastolic (ED) and end-systolic (ES) LV diameters/BW significantly increased, whereas LV FS was decreased after 9 weeks in the DOX group (p<0.001). These parameters remained unchanged in controls. Histological evaluation of hearts from all rats given DOX revealed significant slight degrees of perivascular and interstitial fibrosis. In 7 of the 18 rats, degeneration and myocyte vacuolisation were found. Only five of the controls exhibited evidence of very slight perivascular fibrosis. A significant rise in cTnT was found in DOX rats after cumulative doses of 7.5 and 12 mg/kg in comparison with baseline (p<0.05). cTnT found in rats after 12 mg/kg were significantly greater than that found after 7.5 mg/kg DOX. Maximal cTnI (pg/ml) and cTnT levels were significantly increased in DOX rats compared with controls (p=0.006, 0.007). cTnI (ng/ml), CK-MB mass and CK remained unchanged in DOX rats compared with controls. All markers remained stable in controls. Analysis of data revealed a significant correlation between maximal cTnT and ED and ES LV diameters/BW (r=0.81 and 0.65; p<0.0001). A significant relationship was observed between maximal cTnT and the extent of myocardial morphological changes, and between LV diameters/BW and histological findings. CONCLUSIONS Among markers of ischemic injury after DOX in rats, cTnT showed the greatest ability to detect myocardial damage assessed by echocardiographic detection and histological changes. Although there was a discrepancy between the amount of cTnI and cTnT after DOX, probably due to heterogeneity in cross-reactivities of mAbs to various cTnI and cTnT forms, it is likely that cTnT in rats after DOX indicates cell damage determined by the magnitude of injury induced and that cTnT should be a useful marker for the prediction of experimentally induced cardiotoxicity and possibly for cardioprotective experiments.


Anesthesiology | 2000

Mechanisms of ventricular arrhythmias induced by myocardial contusion: a high-resolution mapping study in left ventricular rabbit heart.

Emmanuelle Robert; Jean Emmanuel de La Coussaye; Antoine G. M. Aya; Jean-Pierre Bertinchant; Anne Polge; Pascale Fabbro-Peray; Christine Pignodel; Jean-Jacques Eledjam

Background: The aims of the Langendorff-perfused rabbit heart study were to evaluate the arrhythmogenic consequences of myocardial contusion and to determine the mechanism of arrhythmia. Methods: Six hearts were in the control group, and 24 hearts (intact heart protocol) were submitted to one of four different contusion kinetic energies (75, 100, 150, or 200 millijoules [mJ]; n = 6). Occurrence of arrhythmia, of an electrically silent area (i.e., area with no electrical activity), and of line of fixed conduction block were reported before and for 1 h after contusion. In 16 hearts (frozen hearts) submitted to cryoprocedure and contusion impact of 100 or 200 mJ, ventricular conduction velocities, anisotropic ratio, wavelengths, ventricular effective refractory period, and its dispersion were measured before and for 1 h after contusion. Using high-resolution mapping, arrhythmias were recorded and analyzed. Results: The intact heart study showed that the number and seriousness of contusion-induced arrhythmias increased with increasing contusion kinetic energy, as did the number of electrically silent areas (five of six ventricular fibrillations and five of six electrically silent areas at 200 mJ). In the frozen heart study, immediately after contusion ventricular effective refractory periods were shortened and dispersed, and wavelengths were also shortened. The arrhythmia analysis showed that all ventricular tachycardias but one were based on reentry developed around an electrically silent area or a line of fixed conduction block. Conclusions: Myocardial contusion has direct arrhythmogenic effects, and the seriousness of arrhythmia increases with the level of contusion kinetic energy. The mechanism of arrhythmia was mainly based on reentrant circuit around a fixed obstacle.


Digestive Diseases and Sciences | 1998

p53 and Follow-up of Colorectal Adenocarcinomas

Anne Polge; Jean-François Bourgaux; Etiennette Bancel; Christine Pignodel; Jean-Christophe Boyer; Sophie Poirey; Bernard Magnan De Bornier; Jean-Louis Balmes; Jean-Pierre Bali

Circulating p53 antibodies (ELISA method), p53genetic alterations (SSCP), and protein overexpression(immunohistochemistry) were studied in 41 patients withcolorectal adenocarcinomas and 10 control patients. Carcinoembryonic antigen (CEA) and carbohydrateantigen 19.9 (CA 19-9) were evaluated in parallel. Tenpatients with p53 antibodies and p53 overexpression wereselected. Tumor DNA extracts from these 10 patients were analyzed by SSCP. Of all 41patients, 10 (24%) showed significant levels of p53antibodies, and p53 accumulation was detected in 20(48%) patients. In six patients, p53 antibodieconcentrations decreased rapidly after surgery; in twopatients, these levels returned to normal values. Of the10 selected tumors, eight revealed TP53 gene mutations.Only two patients with high values of both CEA and CA 19-9 developed p53 antibodies. Inconclusion, beside classical tumor markers, circulatingp53 antibodies may be considered as additional markersfor the management of patients with colorectaladenocarcinomas.


Clinica Chimica Acta | 1999

Time-course of cardiac troponin I release from isolated perfused rat hearts during hypoxia/reoxygenation and ischemia/reperfusion

Jean-Pierre Bertinchant; Anne Polge; Emmanuelle Robert; Nadia Sabbah; Pascale Fabbro-Peray; Sophie Poirey; Michel Laprade; Bernard Pau; Jean-Marie Juan; Jean-Pierre Bali; Jean-Emmanuel de La Coussaye; Michel Dauzat

The study was designed to determine the time-course of cardiac troponin I (cTn-I) release in isolated and Langendorff-perfused rat hearts during hypoxia and reoxygenation (H/Reox), and after various durations of total ischemia and subsequent reperfusion (I/R). For this purpose, in H/Reox, cTn-I was measured with the conventional Access immunoassay (ng/ml) and a new immunoassay which operates at pg/ml, and compared with creatine kinase (CK), lactate dehydrogenase (LD) and cardiac troponin T (cTn-T). In I/R, cTn-I was compared with CK and LD. The anti-Tn-I mAbs used in cTn-I assays cross-react with cTn-I of the rat. A clear difference between time-courses and concentration levels of cTn-I in I/R and H/Reox models was found. In I/R, maximum release of cTn-I, CK and LD similarly occurred within minutes following reperfusion; however cTn-I did not return to baseline values. cTn-I levels were not linked to the duration of ischemia. In I/R, we were only able to detect small cTn-I concentrations. In H/Reox experiments, cTn-I, CK and LD increased time-dependently. We found higher cTn-I maximal peak levels detected with the Access immunoassay than with the new assay (median, 0.346 ng/ml per min/g dry wt vs 132 pg/ml per min/g dry wt). cTn-T maximal concentrations were lower than maximal cTn-I levels (median, 0.117 ng/ml per min/g dry wt). Time-courses of cTn-I release were roughly similar with both assays in the H/Reox model (r = 0.90). These data indicate that the cTn-I time-course is related to experimental model (I/R or H/Reox), but also likely depends on the sensitivity of cTn-I assays in such experimental conditions.


Annales Francaises D Anesthesie Et De Reanimation | 2009

Could B-type Natriuretic Peptide (BNP) plasma concentration be useful to predict fluid in critically ill patients with acute circulatory failure?

L. Muller; Guillaume Louart; J.-L. Teboul; Aba Mahamat; Anne Polge; Jean-Pierre Bertinchant; Jacques Ripart; J.-E. de La Coussaye; J.-Y. Lefrant

BACKGROUND AND OBJECTIVES As B-type Natriuretic Peptide (BNP) is a marker of ventricular wall stress, the present study was aimed at determining whether plasma BNP concentration could predict fluid responsiveness in critically ill patients with acute circulatory failure. METHODS This prospective and non randomized interventional study included 33 sedated, mechanically ventilated patients, with acute circulatory failure requiring cardiac output measurement and fluid challenge. Plasma BNP concentration was measured before and after fluid challenge (250 to 500 ml with infusion rate=999 ml/h). An increase in stroke index (SI) greater than or equal to 15% allowed separation of responders from nonresponders. Receiver operating characteristic (ROC) curves were generated for BNP and compared to that of central venous pressure (CVP) that is routinely considered as a marker of cardiac preload. RESULTS Among 33 patients, there were 24 responders. At baseline, BNP plasma values were less in responders (328 [35-1190] pg/ml versus 535 [223-5000] pg/ml, p<0.03). The area under the ROC curves was 0.74+/-0.11, that was similar to the area under the ROC curve for CVP (0.77+/-0.10). The best cut-off value of plasma BNP level for predicting fluid responsiveness was 193 pg/ml (sensitivity: 38%, specificity: 100%, positive predictive value: 100%, negative predictive value: 38%, accuracy: 55%). Fluid challenge did not increase plasma BNP concentrations in responders and nonresponders. CONCLUSION In critically ill patients with acute circulatory failure, BNP does not accurately predict fluid responsiveness.


Journal of Clinical Laboratory Analysis | 2000

CK-MB mass test in ischemic myocardial injury. Comparison of two tests: BioMerieux Vidas and sanofi access immunoassays.

Sophie Poirey; Anne Polge; Jean-Pierre Bertinchant; Etiennette Bancel; Jean-Christophe Boyer; Pascale Fabbro-Peray; Bernard Magnan De Bornier; Bertrand Ledermann; Michel Bonnier; Jean-Pierre Bali

The analytical and clinical performances of the new fluorescent immunoassay (CK‐MB mass Vidas‐BioMerieux) were examined and compared to the chemiluminescent test (CK‐MB mass Access‐Sanofi‐Pasteur). Assay precisions of the CK‐MB Vidas test within‐assay or between‐assay were less than 5.4 and 5.3%, respectively. Linearity was tested up to 214 μg/L. The CK‐MB Vidas test was free of interference with CK‐BB, CK‐MM, and macro‐CK. One hundred nineteen blood samples from patients with ischemic myocardial injury (IMI): acute myocardial infarction (AMI), suspected myocardial contusion (SMC), and unstable angina pectoris (UA), were tested using both immunoassays. In AMI, a good correlation was found (Y [CK‐MB Access] = 1.1372 × [CK‐MB Vidas] – 6.3902; r2 = 0.96). In UA and SMC, low values were observed and both methods were well correlated (Y [CK‐MB Access] = 1.3662 × [CK‐MB Vidas] + 0.0671; r2 = 0.97). Clinical data were in good agreement with both immunoassays. ROC analysis performed in AMI demonstrated that the clinical performances of the two assays were similar. J. Clin. Lab. Anal. 14:43–47, 2000.


Clinica Chimica Acta | 2005

Prognostic value of cardiac troponin T in patients with both acute and chronic stable congestive heart failure: comparison with atrial natriuretic peptide, brain natriuretic peptide and plasma norepinephrine.

Jean-Pierre Bertinchant; Nicolas Combes; Anne Polge; Pascale Fabbro-Peray; Franck Raczka; Lionel Beck; Stéphane Cade; Bertrand Ledermann


Age and Ageing | 1997

Plasma amino acid concentrations in elderly patients with protein energy malnutrition

Anne Polge; Etiennette Bancel; Helene Bellet Denise Strubel; Sophie Poirey Pascale Peray; Christine Carlet; Bernard Magnan De Bornier

Collaboration


Dive into the Anne Polge's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Aba Mahamat

University of Montpellier

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

J.-Y. Lefrant

University of Montpellier

View shared research outputs
Top Co-Authors

Avatar

Jacques Ripart

University of Montpellier

View shared research outputs
Top Co-Authors

Avatar

Jean-Marie Juan

University of Montpellier

View shared research outputs
Top Co-Authors

Avatar

L. Muller

University of Montpellier

View shared research outputs
Researchain Logo
Decentralizing Knowledge