Anthony P. Sanders
University of Utah
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Anthony P. Sanders.
Journal of Orthopaedic Research | 2012
Anthony P. Sanders; Ira Tibbitts; Rebecca M. Brannon
Ceramic‐on‐ceramic (CoC) hip bearings were tested in short‐term wear tests with a systematically varied contact force. Continuous vibration and intermittent surface roughness measurements were obtained to elucidate potential causes of in vivo hip joint squeaking. The three‐phase test comprised alternating cycles of edge loading (EL) and concentric articulation (CA), always using ample serum lubricant. A 50,000‐cycle wear trial in which the contact force during CA was distant from the heads wear patch yielded no squeaking and practically no liner roughening. In 10‐cycle trials of an edge‐worn head coupled with a pristine liner, the contact force was varied in magnitude and point of application; immediate, recurrent squeaking occurred only when the contact force exceeded a critical threshold value and was centered upon the heads wear patch. In a 27,000‐cycle wear trial with the contact force applied near the margin of the heads wear patch, recurrent squeaking emerged progressively as the liners inner surface was roughened via its articulation with the worn portion of the head. The results reveal key conditions that yield recurrent squeaking in vitro in various scenarios without resorting to implausible dry conditions. A fundamental theory explains that hip squeaking is induced by myriad stress waves emanating from asperity collisions; yet, the root cause is edge loading.
Journal of Tribology-transactions of The Asme | 2011
Anthony P. Sanders; Rebecca M. Brannon
Laboratory testing of contact phenomena can be prohibitively expensive if the interacting bodies are geometrically complicated. This work demonstrates means to mitigate such problems by exploiting the established observation that two geometrically dissimilar contact pairs may exhibit the same contact mechanics. Specific formulas are derived that allow a complicated Hertzian contact pair to be replaced with an inexpensively manufactured and more easily fixtured surrogate pair, consisting of a plane and a spheroid, which has the same (to second-order accuracy) contact area and pressure distribution as the original complicated geometry. This observation is elucidated by using direct tensor notation to review a key assertion in Hertzian theory; namely, geometrically complicated contacting surfaces can be described to second-order accuracy as contacting ellipsoids. The surrogate spheroid geometry is found via spectral decomposition of the original pairs combined Hessian tensor. Some numerical examples using free-form surfaces illustrate the theory, and a laboratory test validates the theory under a common scenario of normally compressed convex surfaces. This theory for a Hertzian contact substitution may be useful in simplifying the contact, wear, or impact testing of complicated components or of their constituent materials.
Journal of Biomedical Materials Research Part B | 2014
Anthony P. Sanders; Rebecca M. Brannon
This research has developed a novel test method for evaluating the wear resistance of ceramic materials under severe contact stresses simulating edge loading in prosthetic hip bearings. Simply shaped test specimens - a cylinder and a spheroid - were designed as surrogates for an edge-loaded, head/liner implant pair. Equivalency of the simpler specimens was assured in the sense that their theoretical contact dimensions and pressures were identical, according to Hertzian contact theory, to those of the head/liner pair. The surrogates were fabricated in three ceramic materials: Al2 O3 , zirconia-toughened alumina (ZTA), and ZrO2 . They were mated in three different material pairs and reciprocated under a 200 N normal contact force for 1000-2000 cycles, which created small (<1 mm(2) ) wear scars. The three material pairs were ranked by their wear resistance, quantified by the volume of abraded material measured using an interferometer. Similar tests were performed on edge-loaded hip implants in the same material pairs. The surrogates replicated the wear rankings of their full-scale implant counterparts and mimicked their friction force trends. The results show that a proxy test using simple test specimens can validly rank the wear performance of ceramic materials under severe, edge-loading contact stresses, while replicating the beginning stage of edge-loading wear. This simple wear test is therefore potentially useful for screening and ranking new, prospective materials early in their development, to produce optimized candidates for more complicated full-scale hip simulator wear tests.
Journal of Biomedical Materials Research Part B | 2016
Anthony P. Sanders; Carly A. Lockard; Joel Weisenburger; Hani Haider; Bart Raeymaekers
With recent improvements to the properties of ultra-high molecular weight polyethylene (UHMWPE) used in joint replacements, prosthetic knee and hip longevity may extend beyond two decades. However, it is difficult and costly to replicate such a long in vivo lifetime using clinically relevant in vitro wear testing approaches such as walking gait joint simulators. We advance a wear test intermediate in complexity between pin-on-disk and knee joint simulator tests. The test uses a surrogate contact pair, consisting of a surrogate femoral and tibial specimen that replicate the contact mechanics of any full-scale knee condyle contact pair. The method is implemented in a standard multi-directional pin-on-disk wear test machine, and we demonstrate its application via a two-million-cycle wear test of three different UHMWPE formulations. Further, we demonstrate the use of digital photography and image processing to accurately quantify fatigue damage based on the reduced transmission of light through a damage area in a UHMWPE specimen. The surrogate contact pairs replicate the knee condyle contact areas within -3% to +12%. The gravimetric wear test results reflect the dose of crosslinking radiation applied to the UHMWPE: 35 kGy yielded a wear rate of 7.4 mg/Mcycles, 55 kGy yielded 1.0 mg/Mcycles, and 75 kGy (applied to a 0.1% vitamin E stabilized UHMWPE) yielded 1.5 mg/Mcycles. A precursor to spalling fatigue is observed and precisely measured in the radiation-sterilized (35 kGy) and aged UHMWPE specimen. The presented techniques can be used to evaluate the high-cycle fatigue performance of arbitrary knee condyle contact pairs under design-specific contact stresses, using existing wear test machines. This makes the techniques more economical and well-suited to standardized comparative testing.
Journal of The Mechanical Behavior of Biomedical Materials | 2016
Carly A. Lockard; Anthony P. Sanders; Bart Raeymaekers
A major limiting factor to the longevity of prosthetic knee joints is fatigue crack damage of the polyethylene tibial insert. Existing methods to quantify fatigue crack damage have several shortcomings, including limited resolution, destructive testing approach, and high cost. We propose an alternative fatigue crack damage visualization and measurement method that addresses the shortcomings of existing methods. This new method is based on trans-illumination and differs from previously described methods in its ability to non-destructively measure subsurface fatigue crack damage while using a simple and cost-effective bench-top set-up. We have evaluated this method to measure fatigue crack damage in two tibial inserts. This new method improves on existing image-based techniques due to its usability for subsurface damage measurement and its decreased reliance on subjective damage identification and measurement.
Journal of The Mechanical Behavior of Biomedical Materials | 2014
Anthony P. Sanders; Bart Raeymaekers
A prosthetic knee joint typically comprises a cobalt-chromium femoral component that articulates with a polyethylene tibial insert. A locking screw may be used to prevent micromotion and dislodgement of the tibial insert from the tibial tray. Screw loosening and back-out have been reported, but the mechanism that causes screw loosening is currently not well understood. In this paper, we experimentally evaluate the effect of polyethylene creep on the preload of the locking screw. We find that the preload decreases significantly as a result of polyethylene creep, which reduces the torque required to loosen the locking screw. The torque applied to the tibial insert due to internal/external rotation within the knee joint during gait could thus drive locking screw loosening and back-out. The results are very similar for different types of polyethylene.
Journal of Arthroplasty | 2012
Anthony P. Sanders; Parth J. Dudhiya; Rebecca M. Brannon
Ceramic acetabular liners may exhibit a small, sharp crest-an artifact of discontinuous machining steps--at the junction between the concave spherical surface and the interior edge. On 3 ceramic liners, this crest was found to form a 9° to 11° deviation from tangency. Edge loading wear tests were conducted directly on this crest and on a smoother region of the edge. The crest elicited 2 to 15 times greater volumetric wear on the femoral head. The propensity of the crest to rapidly (<2000 wear cycles) cause elevated wear under low contact force (200 N) suggests that the crest artifact of prevailing machining protocols might be a root cause of stripe wear and squeaking in ceramic acetabular bearings.
2011 SEM Annual Conference on Experimental and Applied Mechanics | 2011
Anthony P. Sanders; Ira Tibbitts; Deepika Kakarla; Stephanie Siskey; Jorge Ochoa; Kevin Ong; Rebecca M. Brannon
To validate models of contact mechanics in low speed structural impact, slender rods with curved tips were impacted in a drop tower, and measurements of the contact and vibration were compared to analytical and finite element (FE) models. The contact area was recorded using a thin-film transfer technique, and the contact duration was measured using electrical continuity. Strain gages recorded the vibratory strain in one rod, and a laser Doppler vibrometer measured velocity. The experiment was modeled analytically using a quasi-static Hertzian contact law and a system of delay differential equations. The FE model used axisymmetric elements, a penalty contact algorithm, and explicit time integration. A small submodel taken from the initial global model economically refined the analysis in the small contact region. Measured contact areas were within 6% of both models’ predictions, peak speeds within 2%, cyclic strains within 12 microstrain (RMS value), and contact durations within 2 μs. The accuracy of the predictions for this simple test, as well as the versatility of the diagnostic tools, validates the theoretical and computational models, corroborates instrument calibration, and establishes confidence that the same methods may be used in an experimental and computational study of the impact mechanics of artificial hip joints.
Wear | 2014
Anthony Chyr; Mingfeng Qiu; Jared W. Speltz; Ronald L. Jacobsen; Anthony P. Sanders; Bart Raeymaekers
Tribology International | 2014
Mingfeng Qiu; Anthony Chyr; Anthony P. Sanders; Bart Raeymaekers