Anthony R. Day
Pacific Northwest National Laboratory
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Anthony R. Day.
Review of Scientific Instruments | 2012
Ricco Bonicalzi; Michael G. Cantaloub; Anthony R. Day; Luke E. Erikson; J. E. Fast; Joel B. Forrester; Erin S. Fuller; Brian D. Glasgow; Lawrence R. Greenwood; E. W. Hoppe; Todd W. Hossbach; Brian J. Hyronimus; Martin E. Keillor; Emily K. Mace; Justin I. McIntyre; Jason H. Merriman; Allan W. Myers; Cory T. Overman; Nicole R. Overman; Mark E. Panisko; Allen Seifert; Glen A. Warren; Robert C. Runkle
Pacific Northwest National Laboratory recently commissioned a new shallow underground laboratory, located at a depth of approximately 30 meters-water-equivalent. This new addition to the small class of radiation measurement laboratories located at modest underground depths houses the latest generation of custom-made, high-efficiency, low-background gamma-ray spectrometers and gas proportional counters. This paper describes the unique capabilities present in the shallow underground laboratory; these include large-scale ultra-pure materials production and a suite of radiation detection systems. Reported data characterize the degree of background reduction achieved through a combination of underground location, graded shielding, and rejection of cosmic-ray events. We conclude by presenting measurement targets and future opportunities.
Applied Radiation and Isotopes | 2013
Anthony R. Day; Erin S. Fuller; E. W. Hoppe; Martin E. Keillor; B. LeFerriere; Emily K. Mace; J. Merriman; Allan W. Myers; Cory T. Overman; Mark E. Panisko; Allen Seifert; Glen A. Warren; Richard M. Williams
A new ultra-low-background proportional counter was recently developed with an internal volume of 100 cm(3) and has been characterized at pressures from 1-10 atm with P-10 (90% Ar, 10% methane) gas. This design, along with a counting system providing event digitization and passive and active shielding, has been developed to complement a new shallow underground laboratory (30 m water-equivalent). Backgrounds and low-level reference materials have been measured, and system sensitivity for (37)Ar has been calculated.
Applied Radiation and Isotopes | 2013
Richard M. Williams; James H. Ely; Anthony R. Day; James C. Hayes; E. W. Hoppe; B. D. LaFerriere; Emily K. Mace; J. Merriman; Cory T. Overman; Allen Seifert
Pacific Northwest National Laboratory (PNNL) is developing a capability to measure the absolute activity concentration of gaseous radionuclides using length-compensated proportional-counting. This capability will enable the validation of low-level calibration standards for use in PNNLs new shallow underground laboratory. Two sets of unequal length proportional counters have been fabricated; one set has been fabricated using ultra-low background (ULB) electroformed copper and a second set fabricated from Oxygen-Free High-Conductivity Copper (OFHC).
IEEE Transactions on Nuclear Science | 2009
J. E. Fast; Joseph A. Caggiano; Anthony R. Day; Erin S. Fuller; Todd W. Hossbach; Brian J. Hyronimus; Robert C. Runkle; Glen A. Warren
Historically, large germanium arrays for field applications have consisted of multiple detectors each housed in their own cryostat. In order to ruggedize the detectors for field use these cryostats have had additional support material introduced that significantly impacted cryogenic performance. This paper presents the development of a new cryostat design suitable for deployment of ~10 kg of high purity germanium detectors that achieves outstanding cryogenic performance (~5 W at 80 K) while providing the high detection efficiency required for stand-off measurements and the ruggedization required for use in a variety of field applications.
Applied Radiation and Isotopes | 2016
Richard M. Williams; James C. Hayes; Allan W. Myers; Allen Seifert; Anthony R. Day; Emily K. Mace; Theodore W. Bowyer; Harry S. Miley; Justin I. McIntyre; John L. Orrell; Erin S. Fuller; Paul H. Humble; Martin E. Keillor; Derek A. Haas; E. W. Hoppe; Cory T. Overman; B. D. LaFerriere; Mark E. Panisko
Argon-37 is an environmental signature of an underground nuclear explosion. Producing and quantifying low-level (37)Ar standards is an important step in the development of sensitive field measurement instruments. This paper describes progress at Pacific Northwest National Laboratory in developing a process to generate and quantify low-level (37)Ar standards, which can be used to calibrate sensitive field systems at activities consistent with soil background levels. This paper presents a discussion of the measurement analysis, along with assumptions and uncertainty estimates.
Applied Radiation and Isotopes | 2016
Richard M. Williams; Theodore W. Bowyer; Anthony R. Day; Erin S. Fuller; Derek A. Haas; James C. Hayes; E. W. Hoppe; Paul H. Humble; Martin E. Keillor; B. D. LaFerriere; Emily K. Mace; Justin I. McIntyre; Harry S. Miley; Allan W. Myers; John L. Orrell; Cory T. Overman; Mark E. Panisko; Allen Seifert
Argon-37 is an environmental signature of an underground nuclear explosion. Producing and quantifying low-level (37)Ar standards is an important step in the development of sensitive field measurement instruments. This paper describes progress at Pacific Northwest National Laboratory in developing a process to generate and quantify low-level (37)Ar standards, which can be used to calibrate sensitive field systems at activities consistent with soil background levels. This paper presents a discussion of the measurement analysis, along with assumptions and uncertainty estimates.
LOW RADIOACTIVITY TECHNIQUES 2013 (LRT 2013): Proceedings of the IV International Workshop in Low Radioactivity Techniques | 2013
Emily K. Mace; Ricco Bonicalzi; Anthony R. Day; Erin S. Fuller; James C. Hayes; E. W. Hoppe; B. D. LaFerriere; Jason H. Merriman; Cory T. Overman; Allen Seifert; Richard M. Williams
Characterization of two sets of custom unequal length proportional counters is underway at Pacific Northwest National Laboratory (PNNL). These detectors will be used in measurements to determine the absolute activity concentration of gaseous radionuclides (e.g., 37Ar). A set of three detectors has been fabricated based on previous PNNL ultra-low-background proportional counter designs and now operate in PNNLs shallow underground counting laboratory. A second set of four counters has also been fabricated using clean assembly of Oxygen-Free High-Conductivity copper components for use in a shielded above-ground counting laboratory. Characterization of both sets of detectors is underway with measurements of background rates, gas gain, and energy resolution. These results will be presented along with a shielding study for the above-ground cave.
LOW RADIOACTIVITY TECHNIQUES 2013 (LRT 2013): Proceedings of the IV International Workshop in Low Radioactivity Techniques | 2013
Allen Seifert; Ricco Bonicalzi; Ted W. Bowyer; Anthony R. Day; Erin S. Fuller; Derek A. Haas; James C. Hayes; E. W. Hoppe; Paul H. Humble; Martin E. Keillor; B. D. LaFerriere; Emily K. Mace; Justin I. McIntyre; Jason H. Merriman; Harry S. Miley; Allan W. Myers; John L. Orrell; Cory T. Overman; Mark E. Panisko; Richard M. Williams
An ultra-low-background proportional counter design has been developed at Pacific Northwest National Laboratory (PNNL) using clean materials, primarily electro-chemically-purified copper. This detector, along with an ultra-low-background counting system (ULBCS), was developed to complement a new shallow underground laboratory (30 meters water-equivalent) at PNNL. The ULBCS design includes passive neutron and gamma shielding, along with an active cosmic-veto system. This system provides a capability for making ultra-sensitive measurements to support applications like age-dating soil hydrocarbons with 14C/3H, age-dating of groundwater with 39Ar, and soil-gas assay for 37Ar to support On-Site Inspection (OSI). On-Site Inspection is a key component of the verification regime for the Comprehensive Nuclear-Test-Ban Treaty (CTBT). Measurements of radionuclides created by an underground nuclear explosion are valuable signatures of a Treaty violation. For OSI, the 35-day half-life of 37Ar, produced from neutron in...
Archive | 2007
Joseph A. Caggiano; Anthony R. Day; J. E. Fast; Erin S. Fuller
A low-power cryostat was designed and built for the Multi-sensor Airborne Radiation Survey (MARS) project for the purpose of housing a close-packed high-purity germanium (HPGe) detector array of 14 HPGe detectors. The power consumption of the cold mass in the cryostat was measured to be 4.07(11) watts, sufficient for 5.5 days of continuous operation using only 8 liters of liquid nitrogen. Temperatures throughout the cryostat were measured by platinum resistance temperature detectors. These measurements were used to determine the emissivity of the copper used in the floating radiation shield and outer cryostat wall, which was constructed using chemically cleaned and passivated copper metal. Using a PNNL-developed passivation process, an emissivity of 2.5(3)% was achieved for copper.
Journal of Environmental Radioactivity | 2017
Justin I. McIntyre; T.R. Alexander; Henning Back; B.J. Bellgraph; Theodore W. Bowyer; V. Chipman; Matthew W. Cooper; Anthony R. Day; S. Drellack; M.P. Foxe; Bradley G. Fritz; James C. Hayes; Paul H. Humble; Martin E. Keillor; Randy R. Kirkham; E.J. Krogstad; Justin D. Lowrey; Emily K. Mace; M.F. Mayer; Brian D. Milbrath; A. Misner; S.M. Morley; Mark E. Panisko; Khris B. Olsen; Mike D. Ripplinger; Allen Seifert; Reynold Suarez
Pacific Northwest National Laboratory reports on the detection of 39Ar at the location of an underground nuclear explosion on the Nevada Nuclear Security Site. The presence of 39Ar was not anticipated at the outset of the experimental campaign but results from this work demonstrated that it is present, along with 37Ar and 85Kr in the subsurface at the site of an underground nuclear explosion. Our analysis showed that by using state-of-the-art technology optimized for radioargon measurements, it was difficult to distinguish 39Ar from the fission product 85Kr. Proportional counters are currently used for high-sensitivity measurement of 37Ar and 39Ar. Physical and chemical separation processes are used to separate argon from air or soil gas, yielding pure argon with contaminant gases reduced to the parts-per-million level or below. However, even with purification at these levels, the beta decay signature of 85Kr can be mistaken for that of 39Ar, and the presence of either isotope increases the measurement background level for the measurement of 37Ar. Measured values for the 39Ar measured at the site ranged from 36,000 milli- Becquerel/standard-cubic-meter-of-air (mBq/SCM) for shallow bore holes to 997,000 mBq/SCM from the rubble chimney from the underground nuclear explosion.