Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Antonio Acampora is active.

Publication


Featured researches published by Antonio Acampora.


Journal of Mass Spectrometry | 1999

Determination of cyclophosphamide and ifosphamide in urine at trace levels by gas chromatography/tandem mass spectrometry

Nicola Sannolo; Nadia Miraglia; M. Biglietto; Antonio Acampora; Antonio Malorni

A specific and sensitive method based on gas chromatography/tandem mass spectrometry with on-column injection was developed to quantify simultaneously cyclophosphamide and ifosphamide in urine by using trophosphamide as an internal standard. The urine samples were extracted with diethyl ether and derivatization was performed with heptafluorobutyric anhydride. The detection limits of cyclophosphamide and ifosphamide in urine samples were 0.1 and 0.5 ng ml(-1), respectively, with a signal-to-noise ratio of 3 : 1. The sensitivity, the specificity and the low cost of the instrumentation involved make this method suitable for economical analysis on a large scale, such as for the biological monitoring of occupational exposure to cyclophosphamide and ifosphamide in production plants and in hospitals during their pharmacological use.


Current Drug Metabolism | 2011

Analytical and Pharmacological Aspects of Therapeutic Drug Monitoring of mTOR Inhibitors

Maria Pieri; Nadia Miraglia; Giuliano Polichetti; Giovanni Tarantino; Antonio Acampora; Domenico Capone

Mammalian Target Of Rapamycin (mTOR) inhibitors represent a new class of immunosuppressant drugs extensively used for the prevention and the treatment of graft rejection in organ transplant recipients. Their current use is due to referred low nephrotoxic effects, particularly important in kidney transplanted and/or patients with renal failure. The most representative drugs of such class are Sirolimus (Siro) and Everolimus (Rad). Both drugs show a narrow therapeutic window, therefore, monitoring of whole-blood drug levels is recommended in order to optimize the therapy. Among the available assays, Liquid Chromatography coupled with UltraViolet or Electrospray Tandem Mass Spectrometry methods (LC/UV or LC/ESI-MSMS) are the most accurate and specific ones. A reliable alternative is represented by immunoassays, which offer the opportunity to minimize sample pre-treatment, thus reducing the time between drawing blood sample and measuring the drug concentration, an important aspect in high-throughput analyses. Despite this, a limitation in the use of immunoassays for therapeutic drug monitoring is the lower specifity compared with the chromatographic methods when analysing structurally-related drugs. New insights to optimize mTOR inhibitors regimens seem to be offered by the evaluation of CYP450 3A activity by using the probe drug approach. To such purpose, there are a number of major probe drugs used for in vivo studies including: midazolam, cortisol, lidocaine, nifedipine, dextromethorphan, erythromycin, dapsone and alfentanil. The aim of the present paper is to report the most recent knowledge concerning this issue, supplying a critical and comprehensive review for whom are involved both in the clinical and analytical areas.


Journal of Chromatography B | 2003

Determination of urinary S-phenylmercapturic acid by liquid chromatography-tandem mass spectrometry

Maria Pieri; N. Miraglia; Antonio Acampora; Giuliana Genovese; Leonardo Soleo; Nicola Sannolo

Urinary S-phenylmercapturic acid (S-PMA) is considered a useful biomarker for the measurement of low levels of benzene exposure, related to occupational exposure, smoking habits or environmental pollution. S-PMA quantitative analysis requires highly sensitive and specific techniques and purification procedures, mainly based on liquid-liquid or solid-phase extraction, which result in time expensive analyses. A method was developed for the quantitative determination of S-PMA in urine by using a simple, reproducible and easily automatizable HPLC purification followed by LC/ESI-NI/MS2 analysis. In order to reduce the cost of the analysis, related to the use of expensive labeled standards, p-bromo-S-phenylmercapturic acid (p-Br-S-PMA) was synthesized, characterized and used as internal standard. The feasibility and efficacy of the proposed method were examined by constructing calibration curves in the range from 6.2 to 200 microg/l and data were analyzed in terms of linearity and statistical parameters. The detection limit, related to the purification of 1 ml urine sample is 5 microg/l. The method was applied to the analysis of 12 urine samples from smoker subjects non-occupationally exposed to benzene. S-PMA urinary levels ranged from 13.6 to >200 microg/l, suggesting a high influence of life style in the S-PMA excretion. The proposed analytical method is suitable for the biological monitoring of both smoker and non-smoker workers, occupationally exposed to benzene. By processing at least 2 ml of urine samples, the method appears to be also useful for the evaluation of benzene uptake due to the environmental pollution.


Analytical Chemistry | 2011

Screening of several drugs of abuse in Italian workplace drug testing: performance comparisons of on-site screening tests and a fluorescence polarization immunoassay-based device.

Pascale Basilicata; Maria Pieri; Veronica Settembre; Alessandra Galdiero; Elvira Della Casa; Antonio Acampora; Nadia Miraglia

According to the Italian laws, some categories of workers entrusted with duties possibly constituting a threat to security, physical safety, and health of third parties have to be screened to exclude the use/abuse of the following drugs of abuse: opiates, cocaine, cannabinoids, amphetamine, methamphetamine, 3,4-methylenedioxymethamphetamine, methadone, and buprenorphine. Toxicological tests can be performed with urinary on-site rapid screening devices, provided that sensitivities up to specified cutoffs are ensured. The present study reports performances, in terms of sensitivity, specificity, and accuracy, of an automatic on-site test and of an FPIA-based device, using gas chromatography/mass spectrometry (GC/MS) as a reference methodology. Three levels of concentration were tested, corresponding to the cutoff and to 2 and 3 times the limits, respectively. In terms of sensitivities, neither the on-site nor the benchtop instrumentations gave positive results, since values of zero percentage were obtained for concentrations up to 2-fold the limits. Even if good results were obtained in terms of specificity and accuracy by both devices, none of them seem to be adequate for the current application to the toxicological screening at workplaces. In fact, a rapid screening device can be used for drug tests provided that it ensures sensitivity at the prescribed cutoffs. Data showed that such is completely rejected and a more sensitive instrumentation should be preferred.


Journal of Forensic Sciences | 1991

Mass Spectrometry in Forensic Chemistry: 1. Pigment Identification by Direct Mixture Analysis in a Case of Bank Note Falsification

Antonio Acampora; Pasquale Ferranti; Antonio Malorni; Alfredo Milone

A rapid mass spectrometry procedure, based on direct mixture analysis using conventional electron ionization in both the low and high resolution modes, was used to match pigments present on a counterfeit


Clinical Transplantation | 2007

Immunoassay determination of rapamycin: reliability of the method with respect to liquid chromatography mass spectrometric quantification.

Maria Pieri; Domenico Capone; Antonio Gentile; Nadia Miraglia; Emilo Leo; Stefano Federico; Vincenzo Basile; Antonio Acampora

100 United States bank note with pigments contained in two inks suspected of having been used. The results demonstrated that the pigments present on the false bank note and those contained in the inks were the same.


Rapid Communications in Mass Spectrometry | 2009

Study of the fragmentation pattern of ketamine-heptafluorobutyramide by gas chromatography/electron ionization mass spectrometry.

Maria Pieri; Loredana Castiglia; Nadia Miraglia; Rossella Guadagni; Livia Malorni; Nicola Sannolo; Antonio Acampora; Elvira Della Casa

Abstract:  Immunochemical assays represent a promising tool for quantification of immunosuppressants in organ transplanted patients, because they require small sample volumes and minimum sample pre‐treatment; nevertheless considerations about method specificity, sensitivity and reproducibility cannot be overlooked. The present paper investigates the reliability of using the immunoparticle enzyme immunoassay (MEIA) for the quantification of blood rapamycin (RAPA) levels in therapeutic drug monitoring of renal transplanted patients with respect to a validated liquid chromatography tandem mass spectrometric (LC/ESI‐MSMS) method, used as reference. Linearity of MEIA was tested over the range 0.0–30.0 ng/mL, with accuracy and precision within acceptable limits. Fifty‐two blood samples were collected from 42 renal transplanted patients and analyzed simultaneously by both methods. The Pearson’s regression analysis gave the following parameters: correlation equation [RAPA]MEIA = 1.330 + 0.776 [RAPA]LC/ESI‐MSMS, r = 0.8526, SD = 1.778, p < 0.0001. The obtained average rapamycin concentration was 8.8 ± 3.4 ng/mL using MEIA and 9.6 ± 3.7 ng/mL for LC/ESI‐MSMS, with an overall underestimation of about 6% of the immunoenzymatic test. Accuracy of MEIA ranged from −33% to 36% with respect to the reference mass spectrometric method. Although immunoenzymatic test represents a fast and sufficiently accurate method for its use in clinical practice, specificity of the assay is still not sufficiently investigated and reference methods and/or Proficiency Testing Scheme should be used as external control.


Journal of Exposure Science and Environmental Epidemiology | 2013

Epirubicin permeation of personal protective equipment can induce apoptosis in keratinocytes

Maria Pieri; Lucio Quagliuolo; Raffaele La Porta; Angela Silvestre; Nadia Miraglia; Paola Pedata; Antonio Acampora; Loredana Castiglia; Nicola Sannolo; Mariarosaria Boccellino

Ketamine is an anaesthetic compound used in human and veterinary medicine with hallucinogen properties that have resulted in its increased illicit use by teenagers at rave parties. Although several gas chromatography/mass spectrometry (GC/MS) methods have been reported for the quantification of the drug both in urine and in hair, its electron ionization (EI) fragmentation after derivatization with different reagents has been not yet fully investigated. The present work reports the study of the fragmentation of ketamine, derivatized with heptafluorobutyric anhydride (HFBA-Ket), using gas chromatography/electron ionization mass spectrometry (GC/EI-MS). The complete characterization of the fragmentation pattern represented an intriguing exercise and required tandem mass spectrometry (MS(n)) experiments, high-resolution accurate mass measurements and the use of deuterated d(4)-ketamine to corroborate the proposed structures and to characterize the fragment ions carrying the unchanged aromatic moiety. Extensive fragmentation was observed, mainly located at the cyclohexanone ring followed by rearrangement of the fragment ions, as confirmed by the mass spectra obtained from the deuterated molecule. The GC/EI-MS analysis of HFBA-Ket will represent a useful tool in forensic science since high-throughput analyses are enabled, preserving both the GC stationary phase and the cleanliness of the mass spectrometer ion optics.


Annals of Occupational Hygiene | 2005

A case study: surface contamination of cyclophosphamide due to working practices and cleaning procedures in two Italian hospitals.

Antonio Acampora; Loredana Castiglia; Nadia Miraglia; Maria Pieri; Claudio Soave; Francesco Liotti; Nicola Sannolo

The present study investigated the epirubicin (EPI) permeability of various commercially available glove types, as well as toxicity mechanisms and effects on human keratinocyte cell line (HaCaT). Permeability experiments were carried out on various commercially available gloves, differing as regards material and thickness. Permeability was evaluated after different “contact times” and the influence of EPI solutions pH (acid and neutral) on permeability was also examined. Toxicity of EPI toward skin was tested by evaluating the effects of the drug on cell growth and apoptosis, by using an in vitro model based on cultured immortalized human keratinocytes. No permeation was detected in the case of EPI neutral solutions; in contrast, acid solutions were found to penetrate low thickness nitrile gloves. Obtained results also showed the induction of apoptosis in epithelial cells through the activation of intrinsic pathway p53-independent occurring even when cells are exposed at low drug concentration. EPI solutions pH influences the gloves permeability; once penetrated, EPI at concentrations lower than those able to penetrate the nitrile glove during the 8-h work-shift can cause apoptosis in epithelial cells. The findings reported here highly support the choice of either natural rubbers gloves or high thickness nitrile ones for preventing the occupational exposure to EPI.


Journal of Occupational Health | 2008

Evaluation of Occupational Exposure to Antiblastic Drugs in an Italian Hospital Oncological Department

Loredana Castiglia; Nadia Miraglia; Maria Pieri; Angela Simonelli; Pascale Basilicata; Giuliana Genovese; Rossella Guadagni; Antonio Acampora; Nicola Sannolo; Maria Virginia Scafarto

Collaboration


Dive into the Antonio Acampora's collaboration.

Top Co-Authors

Avatar

Nadia Miraglia

Seconda Università degli Studi di Napoli

View shared research outputs
Top Co-Authors

Avatar

Nicola Sannolo

Seconda Università degli Studi di Napoli

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Loredana Castiglia

Seconda Università degli Studi di Napoli

View shared research outputs
Top Co-Authors

Avatar

Pascale Basilicata

Seconda Università degli Studi di Napoli

View shared research outputs
Top Co-Authors

Avatar

Giuliana Genovese

Seconda Università degli Studi di Napoli

View shared research outputs
Top Co-Authors

Avatar

Angela Simonelli

Seconda Università degli Studi di Napoli

View shared research outputs
Top Co-Authors

Avatar

Rossella Guadagni

Seconda Università degli Studi di Napoli

View shared research outputs
Top Co-Authors

Avatar

Adriana Basile

University of Naples Federico II

View shared research outputs
Top Co-Authors

Avatar

Angela Silvestre

Seconda Università degli Studi di Napoli

View shared research outputs
Researchain Logo
Decentralizing Knowledge