Antonio Francisco Pimenta Motta
University of São Paulo
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Antonio Francisco Pimenta Motta.
British Journal of Ophthalmology | 2015
Patrick Frensel Tzelikis; Monike Vieira; Wilson Takashi Hida; Antonio Francisco Pimenta Motta; Celso Takashi Nakano; Eliane Mayumi Nakano; Milton Ruiz Alves
Purpose To compare the anti-inflammatory efficacy of ketorolac of tromethamine 0.4% and nepafenac 0.1% eye drops for prophylaxis of cystoid macular oedema (CME) after small-incision cataract extraction. Methods Patients were assigned randomly to three groups. Group 1 patients received a topical artificial tear substitute (placebo); group 2 received ketorolac tromethamine 0.4% (Acular LS, Allergan) and group 3 received nepafenac 0.1% (Nevanac, Alcon). The incidence and severity of CME were evaluated by retinal foveal thickness on optical coherence tomography (OCT) after 1, 4 and 12 weeks. Results One hundred and twenty-six eyes of 126 patients were included in this study. The between-group differences in visual outcomes, central corneal thickness and endothelial cell density were not statistically significant. In all retinal thickness measurements, an increase was detected starting from the postoperative first week until 12 weeks. There was no statistically significant difference between the three groups in any measurement performed by spectral-domain OCT. Conclusions Used prophylactically after uneventful cataract surgery, non-steroidal anti-inflammatory drugs were not efficacious in preventing macular oedema compared with placebo. Trial registration number ClinicalTrials: NCT02084576.
Arquivos Brasileiros De Oftalmologia | 2009
Wilson Takashi Hida; Antonio Francisco Pimenta Motta; Newton Kara-Jose Junior; Emerson Alves; Marcel Tadeu; Livio Neiva Cordeiro; Celso Takashi Nakano
PURPOSE To compare the visual outcome, contrast sensitivity and wavefront analysis of patients that underwent cataract surgery and implantation of AcrySof SN60D3 multifocal intraocular lens with those who received the AcrySof SN60AT monofocal IOL. METHODS This was a prospective clinical trial of forty eyes that received the multifocal IOL and thirty-two eyes that received the monofocal IOL after phacoemulsification. RESULTS Values for total and spherical aberrations in the multifocal group were statistically lower than in the monofocal group. In the monofocal group, 75% achieved uncorrected intermediate visual acuities between Jaeger 1 and 6. In the multifocal group, 75% of the eyes achieved more than Jaeger 6. At least 87.5% of the multifocal group and 6.3% of the monofocal group achieved monocular uncorrected near acuity of 20/30 (J2, N5) or better. And 90.0% of the eyes in the multifocal group and 37.5% in the monofocal group achieved an uncorrected near acuity of 20/40 (J3, N6) or better. The mean spherical error was 0.11 D in the multifocal group and -0.18 D in the monofocal group (p=0.0379). The SN60D3 group compared to SN60AT group had low contrast sensitivity (log units) with statistically significant differences in 6.0 cpd in photopic conditions (p=0.014) and the SN60D3 group compared to SN60AT group had higher contrast sensitivity (log units) under mesopic conditions (p=0.044). CONCLUSION The multifocal IOLs induced less spherical aberration than monofocal IOLs and predictably good uncorrected distance and uncorrected near acuities. However, contrast sensitivity was lower in the multifocal group.
Arquivos Brasileiros De Oftalmologia | 2008
Wilson Takashi Hida; Antonio Francisco Pimenta Motta; Newton Kara-Jose Junior; Humberto Costa; Clayton Tokunaga; Livio Neiva Cordeiro; Daniela Gemperli; Celso Takashi Nakano
PURPOSE: Comparison of the visual performance and wavefront analysis between patients with Tecnis® ZM900 aspheric and AcrySof ReStor® SN60D3 spheric diffractive multifocal intraocular lenses (IOL). METHODS: This prospective comparative study included 78 eyes of 39 patients. The performed ophthalmologic evaluation included near, intermediate and distance corrected and uncorrected visual acuity, contrast sensitivity measurement (under photopic and mesopic conditions) and wavefront analysis with the OPD-Scan aberrometrer. RESULTS: Uncorrected near and distance visual acuity and aberrometry analysis were similar with both intraocular lenses; nevertheless, intermediate visual acuity and contrast sensitivity under photopic conditions were statistically better with Tecnis ZM900. CONCLUSION: Both studied intraocular lenses promoted excellent near and distance postoperative visual acuity, in high contrast situations. Tecnis ZM900 IOL provided good quality of vision with high contrast condition in low luminosity with reduction in spherical aberration and improvements in intermediate visual acuity when compared to Restor IOL.
Arquivos Brasileiros De Oftalmologia | 2014
Talita Shimoda; Gilberto Shimoda; Wilson Takashi Hida; Celso Takashi Nakano; Antonio Francisco Pimenta Motta; Aline Silva Guimaraes; Patrick Frensel Tzelikis
PURPOSE To assess the postoperative outcomes of a novel toric multifocal in traocular lens (IOL) in patients with cataract and corneal astigmatism. METHODS This prospective nonrandomized study included patients with cataract, corneal astigmatism, and a motivation for spectacle independence. In all patients, a Rayner M-flex® T toric IOL was implanted in the capsular bag. Three months after surgery, the distance, intermediate, and near visual acuities; spherical equivalent; residual refractive astigmatism; defocus curve; and contrast sensitivity were evaluated. A patient satisfaction and visual phenomena questionnaire was administered to all patients. RESULTS Thirty-four eyes of 18 patients were included in this study. Three months after surgery, the mean corrected distance visual acuity (logMAR) was 0.00 ± 0.08 at 6 m, 0.20 ± 0.09 at 70 cm, and 0.08 ± 0.11 at 40 cm. Uncorrected distance vision acuity was 20/40 or better in 100% eyes. The preoperative mean refractive cylinder (RC) was -2.19 (SD: ± 0.53). After a 3-month follow-up, the average RC was -0.44 D (SD: ± 0.27; p<0.001). Contrast sensitivity levels were high. At the last follow-up, 87.5% patients were spectacle-independent for near, intermediate, and distance vision, and approximately 44% patients reported halos and glare. CONCLUSION Toric multifocal IOL implantation in patients with cataract and corneal astigmatism using the Rayner M-flex® T toric IOL was a simple, safe, and accurate option. This technology provides surgeons with a feasible option for meeting patient expectations of an enhanced lifestyle resulting from decreased spectacle dependence.
Arquivos Brasileiros De Oftalmologia | 2015
Wilson Takashi Hida; Patrick Frensel Tzelikis; Celso Takashi Nakano; Antonio Francisco Pimenta Motta; Milton Ruiz Alves
PURPOSE To compare the efficiency of surgical procedures using three phaco tip designs in torsional phacoemulsification using the bevel-down technique. METHODS In this prospective, comparative, masked study, patients were randomly assigned to have torsional coaxial microincision cataract surgery using the mini-flared 45-degree Kelman tip, reversed mini-flared 30-degree Kelman tip, or Sidewinder 30-degree Kelman tip. Clinical measurements included preoperative and 3-month postoperative corrected distance visual acuity (CDVA), endothelial cell counts (ECC), and preoperative and 1-day postoperative central corneal thickness (CCT). Intraoperative measurements included phaco time, torsional time, aspiration time, case time, cumulative dissipated energy (CDE), and balanced salt solution volume (BSS). RESULTS The study evaluated 150 eyes of 150 patients. Intraoperatively, there was no statistically significant difference in cumulative dissipated energy, case time, torsional time, and aspiration time between the three tip configurations. However, less phaco time was used with the mini-flared 45-degree Kelman tip (p=0.02) than that with the Sidewinder 30-degree Kelman tip or reversed mini-flared 30-degree Kelman tip. The mini-flared 45-degree Kelman tip and the reversed mini-flared 30-degree Kelman tip required significantly less balanced salt solution volume than that required by the Sidewinder 30-degree Kelman tip (p=0.009). There was no statistically significant difference in corrected distance visual acuity and endothelial cell counts between tips 3 months postoperatively (p>0.05). CONCLUSION All three tips were effective with no intraoperative complications. When using torsional phacoemulsification through microincisions and the prefracture technique with the bevel-down technique, the mini-flared 45-degree Kelman tip required a lower mean phaco time than the reversed mini-flared 30-degree Kelman tip and the Sidewinder 30-degree Kelman tip.
Revista Brasileira De Oftalmologia | 2009
Celso Takashi Nakano; Wilson Takashi Hida; Newton Kara-Jose Junior; Antonio Francisco Pimenta Motta; Alexandre Soares Castro Reis; Mauricio Pamplona; Reinaldo Fujita; Iris Yamane; Ricardo Holzchuh; Amaryllis Avakian
PURPOSE: The aim of the present study is to assess central corneal edema and visual recovery after cataract surgery performed according to two technologies: conventional ultrasonic and liquefaction (Aqualase®). METHODS:This is a prospective contralateral study in wich 20 patients with comparable preoperative conditions were submitted to cataract surgery were evaluated. Preoperative assessment involved complete ophthalmological examination and the study included patients with bilateral cataracts up to grade 2, according to the Lens Opacity Classification System II. The same cristaline fracture technique was used in all cases, and surgical procedures were performed by the same experienced surgeon, using two technologies: liquefaction or conventional phacoemulsification. Postoperative central corneal edema was measured by corneal optical pachymetry (Orbscan II®) on the 1st, 3rd, 7th and 10th postoperative days. RESULTS:None of the 20 patients submitted to surgery was lost during the postoperative follow-up or excluded from the analysis. On the first postoperative, the visual acuity average was 0.031 logMAR in the Aqualase® group and 0.043 logMAR in the conventional surgery group. No statistical difference was detected in the assessment of visual acuity throughout the postoperative period. Central corneal pachymetry varied from 543.93 + 34.69 preoperatively to 545.08 ± 25.67 on the last day of follow-up in the Aqualase® group, and from 543.13 + 30.62 to 536.08 + 34.89 in the conventional technique group, without statistical significance. CONCLUSION:This study suggests that both techniques are equally effective for surgery on lenses with grade I or II cataract, and that they provide similar results in terms of visual recovery and central corneal edema.
Arquivos Brasileiros De Oftalmologia | 2008
Wilson Takashi Hida; Antonio Francisco Pimenta Motta; Daniela Lumi Inomata; Martha de Queiroz Monteiro Jales; Antonio Carlos Facio Júnior; Newton Kara Junior; Celso Takashi Nakano
The use of multifocal intraocular lenses (IOLs) is a great advance in the treatment of patients with cataract allowing near and distance uncorrected visual acuity recovery. However patients with some degrees of corneal astigmatism have some limitations. We present 3 cases that were indicated for phacoemulsitfication and multifocal intraocular lens implant (AcrySof Restor, Alcon Labs) after limbal relaxing incision (LRI) in the dominant eye and axis topographic incision in the fellow eye. There was no similar case report in the literature. It is believed that this association can extend the indications for multifocal intraocular lens implants in patients with significant corneal astigmatism and this possibility should be confirmed by future studies.
Clinical Ophthalmology | 2017
César Vilar; Wilson Takashi Hida; André Lins de Medeiros; Klayny Rafaella Pereira Magalhães; Patrick Frensel Tzelikis; Mario Augusto Pereira Dias Chaves; Antonio Francisco Pimenta Motta; Pedro Carlos Carricondo; Milton Ruiz Alves; Walton Nosé
Purpose To compare visual outcomes and performance between bilateral implantation of a diffractive trifocal intraocular lens (IOL) Acrysof®PanOptix® TFNT00 and blended implantation of two different near add power bifocal IOLs: Acrysof® Restor® SV25T0 in dominant eye and Acrysof® Restor® SN6AD1 in the nondominant eye. Methods This prospective, nonrandomized, consecutive and comparative study assessed 20 patients (40 eyes) who had bilateral cataract surgery performed using the IOLs described. Patients were divided into groups, bilateral trifocal implant and blended implant. Evaluation included measurement of binocular uncorrected and corrected distance visual acuity at 4 m (UDVA, CDVA) and uncorrected intermediate (60 cm) and near (at 40 cm) visual acuity; contrast sensitivity (CS) and visual defocus curve. Results Postoperative CDVA comparison showed no statistical significance between groups. UDVA was significantly better in the trifocal groups. Under photopic conditions, the trifocal group had better CS in higher frequencies with and without glare. The binocular defocus curve demonstrated a trifocal behavior in both groups, with the bilateral trifocal group exhibiting better performance for intermediate vision. Conclusion Both lens combinations were able to provide good near, intermediate and distance vision, with the trifocal group showing significantly better performance at intermediate distances and better CS under photopic conditions.
Clinical Ophthalmology | 2017
André Lins de Medeiros; André Gustavo de Araújo Rolim; Antonio Francisco Pimenta Motta; Bruna Vieira Ventura; César Vilar; Mario Augusto Pereira Dias Chaves; Pedro Carlos Carricondo; Wilson Takashi Hida
Purpose The purpose of this study was to compare the visual outcomes and subjective visual quality between bilateral implantation of a diffractive trifocal intraocular lens, Alcon Acrysof IQ® PanOptix® TNFT00 (group A), and blended implantation of an extended depth of focus lens, J&J Tecnis Symfony® ZXR00 with a diffractive bifocal intraocular lens, J&J Vision Tecnis® ZMB00 (group B). Methods This prospective, nonrandomized, consecutive, comparative study included the assessment of 40 eyes in 20 patients implanted with multifocal intraocular lens. Exclusion criteria were existence of any corneal, retina, or optic nerve disease, previous eye surgery, illiteracy, previous refractive surgery, high axial myopia, expected postoperative corneal astigmatism of >1.00 cylindrical diopter (D), and intraoperative or postoperative complications. Binocular visual acuity was tested in all cases. Ophthalmological evaluation included the measurement of uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), and uncorrected intermediate visual acuity (UIVA), with the analysis of contrast sensitivity (CS), and visual defocus curve. Results Postoperative UDVA was 0.01 and −0.096 logMAR (p<0.01) in groups A and B, respectively; postoperative CDVA was −0.07 and −0.16 logMAR (p<0.01) in groups A and B, respectively; UIVA was 0.14 and 0.20 logMAR (p<0.01) in groups A and B, respectively; UNVA was −0.03 and 0.11 logMAR (p<0.01) in groups A and B, respectively. Under photopic conditions group B had better CS at low frequencies with and without glare. Conclusion Both groups promoted good quality of vision for long, intermediate, and short distances. Group B exhibited a better performance for very short distances and for intermediate and long distances ≥−1.50 D of vergence. Group A exhibited a better performance for UIVA at 60 cm and for UNVA at 40 cm.
Clinical Ophthalmology | 2017
Wilson Takashi Hida; Patrick Frenzel Tzelikis; César Vilar; Mario Augusto Pereira Dias Chaves; Antonio Francisco Pimenta Motta; Pedro Carlos Carricondo; Bruna Vieira Ventura; Renato Ambrósio Junior; Walton Nosé; Milton Ruiz Alves
Purpose The purpose of this study was to compare intraoperative parameters between femtosecond laser-assisted cataract surgery (FLACS) and conventional phacoemulsification using Centurion® Vision System with Active Fluidics. Setting This study was performed at Brasília Ophthalmologic Hospital, Brasília, Federal District, Brazil. Patients and methods This was a prospective randomized comparative study. Patients with the diagnosis of cataract and surgical extraction programmed were divided into two groups: conventional phacoemulsification and FLACS. Intraoperative data were collected and submitted for statistical analysis. Results A total of 400 eyes were enrolled, 200 in each group. There were no surgical complications. Groups were statistically equivalent in age and nucleus density. Cumulative dissipated energy and torsional time were significantly reduced in the FLACS group. Conventional surgery had less fluid usage, total case time and aspiration (ASP) time. Conclusion FLACS with Active Fluidics System can reduce the ultrasound energy use during cataract surgery, in spite of increasing case time, fluid usage and ASP time.