Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Antti Ahola is active.

Publication


Featured researches published by Antti Ahola.


Biomedical Engineering Online | 2014

Video image-based analysis of single human induced pluripotent stem cell derived cardiomyocyte beating dynamics using digital image correlation.

Antti Ahola; Anna Kiviaho; Kim Larsson; Markus Honkanen; Katriina Aalto-Setälä; Jari Hyttinen

BackgroundThe functionality of a cardiomyocyte is primarily measured by analyzing the electrophysiological properties of the cell. The analysis of the beating behavior of single cardiomyocytes, especially ones derived from stem cells, is challenging but well warranted. In this study, a video-based method that is non-invasive and label-free is introduced and applied for the study of single human cardiomyocytes derived from induced pluripotent stem cells.MethodsThe beating of dissociated stem cell-derived cardiomyocytes was visualized with a microscope and the motion was video-recorded. Minimum quadratic difference, a digital image correlation method, was used for beating analysis with geometrical sectorial cell division and radial/tangential directions. The time series of the temporal displacement vector fields of a single cardiomyocyte was computed from video data. The vector field data was processed to obtain cell-specific, contraction-relaxation dynamics signals. Simulated cardiomyocyte beating was used as a reference and the current clamp of real cardiomyocytes was used to analyze the electrical functionality of the beating cardiomyocytes.ResultsOur results demonstrate that our sectorized image correlation method is capable of extracting single cell beating characteristics from the video data of induced pluripotent stem cell-derived cardiomyocytes that have no clear movement axis, and that the method can accurately identify beating phases and time parameters.ConclusionOur video analysis of the beating motion of single human cardiomyocytes provides a robust, non-invasive and label-free method to analyze the mechanobiological functionality of cardiomyocytes derived from induced pluripotent stem cells. Thus, our method has potential for the high-throughput analysis of cardiomyocyte functions.


IJC Heart & Vasculature | 2015

Distinct electrophysiological and mechanical beating phenotypes of long QT syndrome type 1-specific cardiomyocytes carrying different mutations

Anna Kiviaho; Antti Ahola; Kim Larsson; Kirsi Penttinen; Heikki Swan; Mari Pekkanen-Mattila; Henna Venäläinen; Kiti Paavola; Jari Hyttinen; Katriina Aalto-Setälä

Background Long QT syndrome (LQTS) is associated with increased risk of ventricular arrhythmias and cardiac arrest. LQTS type 1 (LQT1), the most prevalent subtype of LQTS, is caused by defects of slow delayed rectifier potassium current (IKs) that lead to abnormal cardiac repolarization. Here we used pluripotent stem cell (iPSC)-technology to investigate both the electrophysiological and also for the first time the mechanical beating behavior of genetically defined, LQT1 specific cardiomyocytes (CMs) carrying different mutations. Methods We established in vitro models for LQT1 caused by two mutations (G589D or ivs7-2A>G). LQT1 specific CMs were derived from patient specific iPSCs and characterized for their electrophysiology using a current clamp and Ca2 +-imaging. Their mechanical beating characteristics were analyzed with video-image analysis method. Results and conclusions Both LQT1-CM-types showed prolonged repolarization, but only those with G589D presented early after-depolarizations at baseline. Increased amounts of abnormal Ca2 + transients were detected in both types of LQT1-CMs. Surprisingly, also the mechanical beating behavior demonstrated clear abnormalities and additionally the abnormalities were different with the two mutations: prolonged contraction was seen in G589D-CMs while impaired relaxation was observed in ivs7-2A>G-CMs. The CMs carrying two different LQT1 specific mutations (G589D or ivs7-2A>G) presented clear differences in their electrical properties as well as in their mechanical beating behavior. Results from different methods correlated well with each other suggesting that simply mechanical beating behavior of CMs could be used for screening of diseased CMs and possibly for diagnostic purposes in the future.


Biochimica et Biophysica Acta | 2016

Methods for in vitro functional analysis of iPSC derived cardiomyocytes - Special focus on analyzing the mechanical beating behavior.

Eeva Laurila; Antti Ahola; Jari Hyttinen; Katriina Aalto-Setälä

A rapidly increasing number of papers describing novel iPSC models for cardiac diseases are being published. To be able to understand the disease mechanisms in more detail, we should also take the full advantage of the various methods for analyzing these cell models. The traditionally and commonly used electrophysiological analysis methods have been recently accompanied by novel approaches for analyzing the mechanical beatingbehavior of the cardiomyocytes. In this review, we provide first a concise overview on the methodology for cardiomyocyte functional analysis and then concentrate on the video microscopy, which provides a promise for a new faster yet reliable method for cardiomyocyte functional analysis. We also show how analysis conditions may affect the results. Development of the methodology not only serves the basic research on the disease models, but could also provide the much needed efficient early phase screening method for cardiac safety toxicology. This article is part of a Special Issue entitled: Cardiomyocyte Biology: Integration of Developmental and Environmental Cues in the Heart edited by Marcus Schaub and Hughes Abriel.


Annals of Biomedical Engineering | 2018

Simultaneous Measurement of Contraction and Calcium Transients in Stem Cell Derived Cardiomyocytes

Antti Ahola; Risto-Pekka Pölönen; Katriina Aalto-Setälä; Jari Hyttinen

Induced pluripotent stem cell derived cardiomyocytes (iPSC-CM) provide a powerful platform for disease modeling and drug development in vitro. Traditionally, electrophysiological methods or fluorescent dyes (e.g. calcium) have been used in their functional characterization. Recently, video microscopy has enabled non-invasive analysis of CM contractile motion. Simultaneous assessments of motion and calcium transients have not been generally conducted, as motion detection methods are affected by changing pixel intensities in calcium imaging. Here, we present for the first time a protocol for simultaneous video-based measurement of contraction and calcium with fluorescent dye Fluo-4 videos without corrections, providing data on both ionic and mechanic activity. The method and its accuracy are assessed by measuring the effect of fluorescence and background light on transient widths and contraction velocity amplitudes. We demonstrate the method by showing the contraction-calcium relation and measuring the transient time intervals in catecholaminergic polymorphic ventricular tachycardia patient specific iPSC-CMs and healthy controls. Our validation shows that the simultaneous method provides comparable data to combined individual measurements, providing a new tool for measuring CM biomechanics and calcium simultaneously. Our results with calcium sensitive dyes suggest the method could be expanded to use with other fluorescent reporters as well.


SLAS TECHNOLOGY: Translating Life Sciences Innovation | 2018

A Portable Microscale Cell Culture System with Indirect Temperature Control

Antti-Juhana Mäki; Jarmo Verho; Joose Kreutzer; Tomi Ryynänen; Dhanesh Kattipparambil Rajan; Mari Pekkanen-Mattila; Antti Ahola; Jari Hyttinen; Katriina Aalto-Setälä; Jukka Lekkala; Pasi Kallio

A physiologically relevant environment is essential for successful long-term cell culturing in vitro. Precise control of temperature, one of the most crucial environmental parameters in cell cultures, increases the fidelity and repeatability of the experiments. Unfortunately, direct temperature measurement can interfere with the cultures or prevent imaging of the cells. Furthermore, the assessment of dynamic temperature variations in the cell culture area is challenging with the methods traditionally used for measuring temperature in cell culture systems. To overcome these challenges, we integrated a microscale cell culture environment together with live-cell imaging and a precise local temperature control that is based on an indirect measurement. The control method uses a remote temperature measurement and a mathematical model for estimating temperature at the desired area. The system maintained the temperature at 37±0.3 °C for more than 4 days. We also showed that the system precisely controls the culture temperature during temperature transients and compensates for the disturbance when changing the cell cultivation medium, and presented the portability of the heating system. Finally, we demonstrated a successful long-term culturing of human induced stem cell–derived beating cardiomyocytes, and analyzed their beating rates at different temperatures.


International journal of biomedical science : IJBS | 2012

Electrical Field Stimulation with a Novel Platform: Effect on Cardiomyocyte Gene Expression but not on Orientation

Kirsi Kujala; Antti Ahola; Mari Pekkanen-Mattila; Liisa Ikonen; Erja Kerkelä; Jari Hyttinen; Katriina Aalto-Setälä


Frontiers in Physiology | 2017

Evaluation of Optogenetic Electrophysiology Tools in Human Stem Cell-Derived Cardiomyocytes

Susann Björk; Elina A. Ojala; Tommy Nordström; Antti Ahola; Mikko Liljeström; Jari Hyttinen; Esko Kankuri; Eero Mervaala


Archive | 2013

VISUAL CARDIOMYOCYTE ANALYSIS

Katriina Aalto-Setälä; Anna Kiviaho; Jari Hyttinen; Antti Ahola; Markus Honkanen; Henna Venäläinen


computing in cardiology conference | 2014

Motion analysis method for determining cardiomyocyte beating properties based on digital image correlation and templates

Antti Ahola; Paruthi Pradhapan; Eeva Laurila; Katriina Aalto-Setälä; Jari Hyttinen


Sensors and Actuators B-chemical | 2017

Fluorimetric oxygen sensor with an efficient optical read-out for in vitro cell models

Hannu Välimäki; Jarmo Verho; Joose Kreutzer; Dhanesh Kattipparambil Rajan; Tomi Ryynänen; Mari Pekkanen-Mattila; Antti Ahola; Kirsi Tappura; Pasi Kallio; Jukka Lekkala

Collaboration


Dive into the Antti Ahola's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Joose Kreutzer

Tampere University of Technology

View shared research outputs
Top Co-Authors

Avatar

Jukka Lekkala

Tampere University of Technology

View shared research outputs
Top Co-Authors

Avatar

Pasi Kallio

Tampere University of Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Hannu Välimäki

Tampere University of Technology

View shared research outputs
Researchain Logo
Decentralizing Knowledge