Antti Tarkiainen
Lappeenranta University of Technology
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Antti Tarkiainen.
IEEE Power Electronics Letters | 2004
Antti Tarkiainen; Riku Pollanen; Markku Niemela; Juha Pyrhönen
A voltage feedback active filter is vulnerable to unknown grid impedance. To overcome this problem we propose an identification method, which uses the control system of a frequency selective active filter to measure the grid impedance at selected frequencies. The usefulness of the method is experimentally demonstrated with a 19 kVA active rectifier with a voltage feedback active filtering function. The voltage feedback active filtering is performed in a case in which the active filter control is not stable before the impedance is identified with the method proposed. It is shown that the use of the measured grid impedance in the control system greatly enhances the dynamic stability of the system. Also, the grid impedance measurements are provided in two cases.
international electric machines and drives conference | 2003
Antti Tarkiainen; Riku Pollanen; Markku Niemela; Juha Pyrhönen; Mikko Vertanen
An algorithm for compensating island network voltage unsymmetricity with a DTC-modulation based scalar controlled power conditioning system is introduced and experimentally verified. The proposed method consists two separate stages where first the unsymmetricity is detected and then the compensating negative sequence system is calculated. Experimental results show that the proposed method fully compensates the voltage unsymmetricity resulting from unbalanced load. Both the magnitude and the phase angle unsymmetricity are compensated.
IEEE Transactions on Industry Applications | 2004
Antti Tarkiainen; R. Pollanen; Markku Niemela; Juha Pyrhönen; M. Vertanen
An algorithm for compensating island network voltage unsymmetricity with a direct torque control modulation-based scalar-controlled power conditioning system is introduced and experimentally verified. The proposed method consists of two separate stages where at first the unsymmetricity is detected and then a compensating negative-sequence system is calculated. Experimental results show that the proposed method fully compensates the voltage unsymmetricity resulting from unbalanced load. Both the magnitude and the phase angle unsymmetricity are compensated.
Archive | 2003
Riku Pollanen; Antti Tarkiainen
Archive | 2004
Antti Tarkiainen; Mikko Vertanen
Archive | 2002
Antti Tarkiainen; Riku Pollanen
Electrical Engineering | 2006
Antti Tarkiainen; Riku Pollanen; Markku Niemela; Juha Pyrhönen
European Transactions on Electrical Power | 2004
Antti Tarkiainen; Riku Pollanen; Markku Niemela; Juha Pyrhönen
Electrical Engineering | 2005
Riku Pollanen; Antti Tarkiainen; Olli Pyrhönen
Procedia - Social and Behavioral Sciences | 2004
Antti Tarkiainen; Riku Pollanen; Markku Niemela; Juha Pyrhönen