Anuj Bhargava
Mercy Medical Center (Baltimore, Maryland)
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Anuj Bhargava.
Diabetes Care | 2013
Stephen C. L. Gough; Anuj Bhargava; Rajeev Jain; Henriette Mersebach; Søren Rasmussen; Richard M. Bergenstal
OBJECTIVE The 200 units/mL formulation of insulin degludec (IDeg 200 units/mL) contains equal units of insulin in half the volume compared with the 100 units/mL formulation. We compared the efficacy and safety of IDeg 200 units/mL once daily with 100 units/mL insulin glargine (IGlar) in insulin-naïve subjects with type 2 diabetes (T2DM) inadequately controlled with oral antidiabetic drugs. RESEARCH DESIGN AND METHODS In this 26-week, open-label, treat-to-target trial, subjects (n = 457; mean HbA1c 8.3% [67 mmol/mol], BMI 32.4 kg/m2, and fasting plasma glucose [FPG] 9.6 mmol/L [173.2 mg/dL]) were randomized to IDeg 200 units/mL or IGlar, both given once daily in combination with metformin with or without a dipeptidyl peptidase-4 inhibitor. Basal insulin was initiated at 10 units/day and titrated weekly to an FPG target of <5 mmol/L (<90 mg/dL) according to mean prebreakfast self-measured blood glucose values from the preceding 3 days. RESULTS By 26 weeks, IDeg reduced HbA1c by 1.30% and was not inferior to IGlar. Mean observed FPG reductions were significantly greater with IDeg than IGlar (−3.7 vs. −3.4 mmol/L [–67 vs. –61 mg/dL]; estimated treatment difference: −0.42 [95% CI −0.78 to −0.06], P = 0.02). Despite this difference, rates of overall confirmed hypoglycemia were not higher with IDeg than with IGlar (1.22 and 1.42 episodes/patient-year, respectively), as were rates of nocturnal confirmed hypoglycemia (0.18 and 0.28 episodes/patient-year, respectively). Mean daily basal insulin dose was significantly lower by 11% with IDeg 200 units/mL compared with IGlar. IDeg was well-tolerated, and the rate of treatment-emergent adverse events was similar across groups. CONCLUSIONS In this treat-to-target trial in insulin-naïve patients with T2DM, IDeg 200 units/mL improved glycemic control similarly to IGlar with a low risk of hypoglycemia.
Diabetes, Obesity and Metabolism | 2015
Julio Rosenstock; P. Hollander; Anuj Bhargava; Liza L. Ilag; Robyn K. Pollom; J. S. Zielonka; W. J. Huster; Melvin J. Prince
To compare the efficacy and safety of LY2963016 insulin glargine (LY IGlar) and the reference product (Lantus®) insulin glargine (IGlar) in combination with oral antihyperglycaemic medications in patients with type 2 diabetes (T2D).
Diabetes Care | 2016
Ruth S. Weinstock; Stephanie N. DuBose; Richard M. Bergenstal; Naomi Chaytor; Christina Peterson; Beth A. Olson; Medha N. Munshi; Alysa J S Perrin; Kellee M. Miller; Roy W. Beck; David R. Liljenquist; Grazia Aleppo; John B. Buse; Davida F. Kruger; Anuj Bhargava; Robin Goland; Rachel C. Edelen; Richard E. Pratley; Anne L. Peters; Henry Rodriguez; Andrew J. Ahmann; John Paul Lock; Satish K. Garg; Michael R. Rickels; Irl B. Hirsch
OBJECTIVE Severe hypoglycemia is common in older adults with long-standing type 1 diabetes, but little is known about factors associated with its occurrence. RESEARCH DESIGN AND METHODS A case-control study was conducted at 18 diabetes centers in the T1D Exchange Clinic Network. Participants were ≥60 years old with type 1 diabetes for ≥20 years. Case subjects (n = 101) had at least one severe hypoglycemic event in the prior 12 months. Control subjects (n = 100), frequency-matched to case subjects by age, had no severe hypoglycemia in the prior 3 years. Data were analyzed for cognitive and functional abilities, social support, depression, hypoglycemia unawareness, various aspects of diabetes management, C-peptide level, glycated hemoglobin level, and blinded continuous glucose monitoring (CGM) metrics. RESULTS Glycated hemoglobin (mean 7.8% vs. 7.7%) and CGM-measured mean glucose (175 vs. 175 mg/dL) were similar between case and control subjects. More case than control subjects had hypoglycemia unawareness: only 11% of case subjects compared with 43% of control subjects reported always having symptoms associated with low blood glucose levels (P < 0.001). Case subjects had greater glucose variability than control subjects (P = 0.008) and experienced CGM glucose levels <60 mg/dL for ≥20 min on 46% of days compared with 33% of days in control subjects (P = 0.10). On certain cognitive tests, case subjects scored worse than control subjects. CONCLUSIONS In older adults with long-standing type 1 diabetes, greater hypoglycemia unawareness and glucose variability are associated with an increased risk of severe hypoglycemia. A study to assess interventions to prevent severe hypoglycemia in high-risk individuals is needed.
Diabetes, Obesity and Metabolism | 2013
Athena Philis-Tsimikas; S. Del Prato; I. Satman; Anuj Bhargava; M. Dharmalingam; T. V. Skjøth; Søren Rasmussen; Alan J. Garber
The efficacy and safety of insulin degludec (IDeg), a new basal insulin with an ultra‐long duration of action, was compared to sitagliptin (Sita) in a 26‐week, open‐label trial.
Diabetes Care | 2017
Grazia Aleppo; Katrina J. Ruedy; Tonya D. Riddlesworth; Davida F. Kruger; Anne L. Peters; Irl B. Hirsch; Richard M. Bergenstal; Elena Toschi; Andrew J. Ahmann; Viral N. Shah; Michael R. Rickels; Bruce W. Bode; Athena Philis-Tsimikas; Rodica Pop-Busui; Henry Rodriguez; Emily Eyth; Anuj Bhargava; Craig Kollman; Roy W. Beck
OBJECTIVE To determine whether the use of continuous glucose monitoring (CGM) without confirmatory blood glucose monitoring (BGM) measurements is as safe and effective as using CGM adjunctive to BGM in adults with well-controlled type 1 diabetes (T1D). RESEARCH DESIGN AND METHODS A randomized noninferiority clinical trial was conducted at 14 sites in the T1D Exchange Clinic Network. Participants were ≥18 years of age (mean 44 ± 14 years), had T1D for ≥1 year (mean duration 24 ± 12 years), used an insulin pump, and had an HbA1c ≤9.0% (≤75 mmol/mL) (mean 7.0 ± 0.7% [53 ± 7.7 mmol/mol]); prestudy, 47% were CGM users. Participants were randomly assigned 2:1 to the CGM-only (n = 149) or CGM+BGM (n = 77) group. The primary outcome was time in range (70–180 mg/dL) over the 26-week trial, with a prespecified noninferiority limit of 7.5%. RESULTS CGM use averaged 6.7 ± 0.5 and 6.8 ± 0.4 days/week in the CGM-only and CGM+BGM groups, respectively, over the 26-week trial. BGM tests per day (including the two required daily for CGM calibration) averaged 2.8 ± 0.9 and 5.4 ± 1.4 in the two groups, respectively (P < 0.001). Mean time in 70–180 mg/dL was 63 ± 13% at both baseline and 26 weeks in the CGM-only group and 65 ± 13% and 65 ± 11% in the CGM+BGM group (adjusted difference 0%; one-sided 95% CI −2%). No severe hypoglycemic events occurred in the CGM-only group, and one occurred in the CGM+BGM group. CONCLUSIONS Use of CGM without regular use of confirmatory BGM is as safe and effective as using CGM with BGM in adults with well-controlled T1D at low risk for severe hypoglycemia.
Current Medical Research and Opinion | 2011
Richard M. Bergenstal; Louis P. Garrison; Lesley Ann Miller; Likun Hou; Amy Blickensderfer; Anthony Zagar; Shelley Stanley; Anuj Bhargava; Rolin L. Wade; William H. Herman
Abstract Objective: The Exenatide BID Observational Study (ExOS) was designed to evaluate the clinical effectiveness of exenatide BID use in patients with type 2 diabetes (T2D) in a real-world clinical practice setting in the United States. Methods: Patients were enrolled from 74 practice sites from 9/2007 through 1/2009 and followed for 12 months. The primary effectiveness endpoint was achieving or maintaining hemoglobin A1C of ≤7.0%, or an absolute drop of 0.5% from baseline. Secondary measures included absolute and percentage change from baseline for a variety of clinical measures (lipid markers, weight, BMI, etc.), and quality of life (QOL) was assessed using the Impact of Weight on Quality of Life (IWQOL)-Lite. Results: A total of 452 patients were included in the primary study population. At baseline, patients (60% female) had mean (SD) age of 55 (11), T2D duration of 9 (8) years, HbA1c of 8.0 (1.7) %, and body mass index (BMI) of 38.2 (7.4) kg/m2. Family history of T2D was reported in 73.9% of patients. Hypertension was reported in 61.5% of patients, and 47.1% had hyperlipidemia. The HbA1c goal was achieved in 76.3% of the 118 patients with A1C measurements available at 12 months (P < 0.0001). Patients with available clinical measurements achieved significant improvements in HbA1c, weight, BMI, and QOL measurements at 12 months. A mean improvement of 4.56 was seen in the total IWQOL-Lite score at 12 months (P = 0.001). The single-arm design of this study is a limitation; however, the overall objective of the study was to observe patients on exenatide BID therapy over time, comparing their status at endpoint to baseline, rather than to make comparisons among different drug therapies. Conclusions: The Exenatide BID Observational Study supports the clinical effectiveness of exenatide BID observed in previous clinical trials and retrospective database studies.
The Lancet Diabetes & Endocrinology | 2017
Roy W. Beck; Tonya D. Riddlesworth; Katrina J. Ruedy; Craig Kollman; Andrew J. Ahmann; Richard M Bergenstal; Anuj Bhargava; Bruce W. Bode; Stacie Haller; Davida F. Kruger; Janet B. McGill; William H. Polonsky; David Price; Elena Toschi; Howard Wolpert; Astrid Atakov-Castillo; Edvina Markovic; Stephen Aronoff; Satanya Brooks; Gloria Martinez; Angela Mendez; Theresa Dunnam; Kathy Fitzgerald; Diana Wright; Teck Khoo; Pierre Theuma; Tara Herrold; Debra Thomsen; Richard M. Bergenstal; Kathleen McCann
BACKGROUND The benefit of initiation of insulin pump therapy (continuous subcutaneous insulin infusion; CSII) in patients with type 1 diabetes using continuous glucose monitoring (CGM) has not been studied. We aimed to assess glycaemic outcomes when switching from multiple daily injections (MDI) to CSII in adults with type 1 diabetes using CGM. METHODS In this multicentre, randomised controlled trial, 75 adults with type 1 diabetes in the CGM group of the DIAMOND trial were randomly assigned via the study website using a computer-generated sequence to continue MDI or switch to CSII, with continuation of CGM, for 28 weeks. The primary outcome was CGM-measured time in the glucose concentration range of 70-180 mg/dL (3·9-10·0 mmol/L). This study is registered with ClinicalTrials.gov, number NCT02282397. FINDINGS Between April 14, 2015, and May 5, 2016, 37 participants were randomly assigned to the CGM plus CSII group and 38 participants were randomly assigned to the CGM plus MDI group. The study was completed by 36 (97%) of 37 participants in the CGM plus CSII group and 35 (92%) of 38 participants in the CGM plus MDI group. Mean CGM use was 6·7 days per week (SD 0·8) in the CGM plus CSII group and 6·9 days per week (0·3) in the CGM plus MDI group (p=0·86). No participants in the CGM plus CSII group who completed the trial discontinued CSII. Over the follow-up period, mean time in the glucose concentration range of 70-180 mg/dL (3·9-10·0 mmol/L) was 791 min per day (SD 157) in the CGM plus CSII group and 741 min per day (225) in the CGM plus MDI group (adjusted mean treatment group difference: 83 min, 95% CI 17-149; p=0·01). Participants in the CGM plus CSII group had a greater reduction in CGM-measured mean glucose (p=0·005) and hyperglycaemia (on four metrics: p=0·007 for >180 mg/dL [>10·0 mmol/L], p=0·02 for >250 mg/dL [>13·9 mmol/L], p=0·04 for >300 mg/dL [>16·6 mmol/L], and p=0·02 for the area under the curve for 180 mg/dL [10·0 mmol/L]), but also an increase in CGM-measured hypoglycaemia (p=0·0001 for <70 mg/dL [<3·9 mmol/L], p=0·0002 for <60 mg/dL [<3·3 mmol/L], p=0·0009 for <50 mg/dL [<2·8 mmol/L], p=0·0002 for the area over the curve for 70 mg/dL [3·9 mmol/L]). Mean HbA1c change from baseline to 28 weeks was 0·3% (SD 0·9; 3·3 mmol/mol [SD 9·8]) in the CGM plus CSII group and 0·1% (0·4; 1·1 mmol/mol [4·4]) in the CGM plus MDI group (p=0·32). Severe hypoglycaemia occurred in one participant in the CGM plus MDI group, and diabetic ketoacidosis and severe hyperglycaemia occurred in one participant each in the CGM plus CSII group. INTERPRETATION Our findings show that glycaemic control measured by time in the glucose range of 70-180 mg/dL (3·9-10·0 mmol/L) is improved by initiation of CSII in adults with type 1 diabetes. However, biochemical hypoglycaemia also was increased in the study, which will be important to consider when incorporating these results into clinical practice. FUNDING Dexcom.
Current Medical Research and Opinion | 2012
Bruce S. Trippe; Mark D. Shepherd; Franklin C. Coulter; Anuj Bhargava; Jason Brett; Pei-Ling Chu; David Oyer
Abstract Objective: To determine if self-titration using biphasic insulin aspart 70/30 (BIAsp 30) had a different impact on efficacy and safety across different racial/ethnic subgroups. Research design/methods: This was an exploratory, post hoc analysis by race (White vs. Black/African-American) and ethnicity (Hispanic/Latino vs. non-Hispanic/Latino) of data from the INITIATEplus trial. Participants were treated twice-daily with BIAsp 30 over 24 weeks. Trial registration: ClinicalTrials.gov identifier: NCT00101751. Main outcome measures: Efficacy endpoints included reductions in mean glycated hemoglobin (A1C) and fasting plasma glucose (FPG). Safety endpoints included hypoglycemia rates (events/patient-year) and adverse events. Body weight changes were also measured. Results: Glycemic control improved by a similar extent for all demographic groups. Observed mean decreases in A1C ranged from 2.4% to 2.6% after 24 weeks’ treatment. Baseline-adjusted mean A1C decreases for White vs. Black/African-American subjects were 2.56% and 2.13% (p < 0.0001), and for Hispanic/Latino vs. non-Hispanic/Latino subjects were 2.45% and 2.42% (p = 0.677), respectively. Final FPG values were similar among all groups (141–146 mg/dL [7.83–8.10 m mol/L]), and baseline-adjusted FPG decreases were not significantly different (p > 0.025) between groups. Hypoglycemia was low for White, Black/African-American, Hispanic/Latino, and non-Hispanic/Latino subjects (0.08, 0.04, 0.03, and 0.07 major events/patient-year, with 0.60, 0.30, 0.37, and 0.52 minor events/patient-year, respectively). Body weight increases were 3.17 and 3.06 kg (White vs. African-American) and 2.69 and 3.19 kg (Hispanic/Latino vs. non-Hispanic/Latino). Final weight-adjusted total daily insulin doses were 0.60 U/kg for Black/African-American subjects vs. 0.78 U/kg for White subjects (p < 0.0001), and 0.71 U/kg for Hispanic/Latino subjects vs. 0.74 U/kg for non-Hispanic/Latino subjects (p = 0.42). Limitations: The trial was not designed or powered for comparisons across racial or ethnic groups, subjects were not stratified for pre-baseline medication regimens between each race and ethnic group, and unequal subject numbers and baseline A1C disparities existed between the pairs of groups being compared. Conclusions: Diabetes self-management with BIAsp 30 using an easily followed self-titration algorithm produced low hypoglycemia rates. All subgroups achieved A1C reductions >2.1% and FPG declines >82 mg/dL that were similar across groups, demonstrating that self-titration of BIAsp 30 can successfully be pursued in a primary care setting by patients who had previously failed to meet ADA A1C targets under oral antidiabetes therapy, with race or ethnicity not an obstacle to achieving better glycemic control.
Diabetes, Obesity and Metabolism | 2018
J. Hans DeVries; Timothy S. Bailey; Anuj Bhargava; Gregg Gerety; Janusz Gumprecht; Simon Heller; Wendy Gwirtzman Lane; Carol H. Wysham; Bernard Zinman; Britta A. Bak; Elise Hachmann-Nielsen; Athena Philis-Tsimikas
To investigate the association between day‐to‐day fasting self‐monitored blood glucose (SMBG) variability and risk of hypoglycaemia in type 1 (T1D) and type 2 diabetes (T2D), and to compare day‐to‐day fasting SMBG variability between treatments with insulin degludec (degludec) and insulin glargine 100 units/mL (glargine U100).
Clinical Diabetes | 2018
Louis Chaykin; Anuj Bhargava; Raymond De la Rosa; Carol H. Wysham; Lone Nørgård Troelsen; Signe H. Østoft; Athena Philis-Tsimikas
IN BRIEF Hispanic patients with type 2 diabetes have poorer glycemic control and are at higher risk of severe diabetes complications and mortality than non-Hispanic white patients. This post hoc analysis investigated the safety and efficacy of insulin degludec versus insulin glargine 100 units/mL (glargine U100) in the Hispanic patient subpopulation from the SWITCH 2 trial. In Hispanic patients, hypoglycemia was consistently lower and nocturnal hypoglycemia was significantly lower with degludec versus glargine U100 at similar levels of glycemic control. Overall, results in Hispanic patients in SWITCH 2 were consistent with those in non-Hispanic patients.