Ari Kauppinen
National Institute for Health and Welfare
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Ari Kauppinen.
Journal of Environmental Management | 2014
Ari Kauppinen; Kati Martikainen; Ville Matikka; Anna-Maria Veijalainen; Tarja Pitkänen; Helvi Heinonen-Tanski; Ilkka T. Miettinen
Onsite wastewater treatment systems (OWTS) are recognised as potential threats to groundwater or other water environments subject to discharged effluents. In this study, the microbiological and nutrient removal properties of three different pilot-scale sand filters (SFs) were followed over a one-year period. Moreover, a separate phosphorus removal unit was tested for six months. For the best treatment system, the average log removals were 2.2-3.5 for pathogenic human noro- and adenoviruses and 4.3-5.2 and 4.6-5.4 for indicator viruses and bacteria, respectively. The system that effectively removed microbes was also efficient at removing nutrients. However, the poorest treatment system yielded substantially lower removals. The remarkable differences noted between the studied SFs highlights the importance of construction materials and the careful planning of the filters. Moreover, seasonal conditions appear to have a clear effect on purification efficiencies, emphasising the vulnerability of these systems especially in cold climates.
PLOS ONE | 2014
Katri Jalava; Hanna Rintala; Jukka Ollgren; Leena Maunula; Vicente Gomez-Alvarez; Joana Revez; Marja Palander; Jenni Antikainen; Ari Kauppinen; Pia Räsänen; Sallamaari Siponen; Outi Nyholm; Aino Kyyhkynen; Sirpa Hakkarainen; Juhani Merentie; Martti Pärnänen; Raisa Loginov; Hodon Ryu; Markku Kuusi; Anja Siitonen; Ilkka T. Miettinen; Jorge W. Santo Domingo; Marja-Liisa Hänninen; Tarja Pitkänen
Failures in the drinking water distribution system cause gastrointestinal outbreaks with multiple pathogens. A water distribution pipe breakage caused a community-wide waterborne outbreak in Vuorela, Finland, July 2012. We investigated this outbreak with advanced epidemiological and microbiological methods. A total of 473/2931 inhabitants (16%) responded to a web-based questionnaire. Water and patient samples were subjected to analysis of multiple microbial targets, molecular typing and microbial community analysis. Spatial analysis on the water distribution network was done and we applied a spatial logistic regression model. The course of the illness was mild. Drinking untreated tap water from the defined outbreak area was significantly associated with illness (RR 5.6, 95% CI 1.9–16.4) increasing in a dose response manner. The closer a person lived to the water distribution breakage point, the higher the risk of becoming ill. Sapovirus, enterovirus, single Campylobacter jejuni and EHEC O157:H7 findings as well as virulence genes for EPEC, EAEC and EHEC pathogroups were detected by molecular or culture methods from the faecal samples of the patients. EPEC, EAEC and EHEC virulence genes and faecal indicator bacteria were also detected in water samples. Microbial community sequencing of contaminated tap water revealed abundance of Arcobacter species. The polyphasic approach improved the understanding of the source of the infections, and aided to define the extent and magnitude of this outbreak.
Journal of Water and Health | 2012
Ari Kauppinen; Jenni Ikonen; Anna Pursiainen; Tarja Pitkänen; Ilkka T. Miettinen
A contaminated drinking water distribution network can be responsible for major outbreaks of infections. In this study, two chemical decontaminants, peracetic acid (PAA) and chlorine, were used to test how a laboratory-scale pipeline system can be cleaned after simultaneous contamination with human adenovirus 40 (AdV40) and Escherichia coli. In addition, the effect of the decontaminants on biofilms was followed as heterotrophic plate counts (HPC) and total cell counts (TCC). Real-time quantitative polymerase chain reaction (qPCR) was used to determine AdV40 and plate counting was used to enumerate E. coli. PAA and chlorine proved to be effective decontaminants since they decreased the levels of AdV40 and E. coli to below method detection limits in both water and biofilms. However, without decontamination, AdV40 remained present in the pipelines for up to 4 days. In contrast, the concentration of cultivable E. coli decreased rapidly in the control pipelines, implying that E. coli may be an inadequate indicator for the presence of viral pathogens. Biofilms responded to the decontaminants by decreased HPCs while TCC remained stable. This indicates that the mechanism of pipeline decontamination by chlorine and PAA is inactivation rather than physical removal of microbes.
Journal of Water and Health | 2013
Surendra kumar Pradhan; Ari Kauppinen; Kati Martikainen; Tarja Pitkänen; Jaana Kusnetsov; Ilkka T. Miettinen; Matti Pessi; Hannu Poutiainen; Helvi Heinonen-Tanski
Wastewater is an important source of pathogenic enteric microorganisms in surface water and a major contaminating agent of drinking water. Although primary and secondary wastewater treatments reduce the numbers of microorganisms in wastewater, significant numbers of microbes can still be present in the effluent. The aim of this study was to test the feasibility of tertiary treatment for municipal wastewater treatment plants (WWTPs) using PIX (FeCl3) or PAX (AlCl3) coagulants and peracetic acid (PAA) the disinfectant to reduce microbial load in effluent. Our study showed that both PIX and PAX efficiently reduced microbial numbers. PAA disinfection greatly reduced the numbers of culturable indicator microorganisms (Escherichia coli, intestinal enterococci, F-specific RNA coliphages and somatic DNA coliphages). In addition, pathogenic microorganisms, thermotolerant Campylobacter, Salmonella and norovirus GI, were successfully reduced using the tertiary treatments. In contrast, clostridia, Legionella, rotavirus, norovirus GII and adenovirus showed better resistance against PAA compared to the other microorganisms. However, interpretation of polymerase chain reaction (PCR) analysis results will need further studies to clarify the infectivity of the pathogenic microbes. In conclusion, PIX and PAX flocculants followed by PAA disinfectant can be used as a tertiary treatment for municipal WWTP effluents to reduce the numbers of indicator and pathogenic microorganisms.
Eurosurveillance | 2017
Ari Kauppinen; Haider Al-Hello; Outi Zacheus; Jaana Kilponen; Leena Maunula; Sari Huusko; Maija Lappalainen; Ilkka T. Miettinen; Soile Blomqvist; Ruska Rimhanen-Finne
An increased number of suspected outbreaks of gastroenteritis linked to bathing water were reported to the Finnish food- and waterborne outbreak (FWO) registry in July and August 2014. The investigation reports were assessed by a national outbreak investigation panel. Eight confirmed outbreaks were identified among the 15 suspected outbreaks linked to bathing water that had been reported to the FWO registry. According to the outbreak investigation reports, 1,453 persons fell ill during these outbreaks. Epidemiological and microbiological data revealed noroviruses as the main causative agents. During the outbreaks, exceptionally warm weather had boosted the use of beaches. Six of eight outbreaks occurred at small lakes; for those, the investigation strongly suggested that the beach users were the source of contamination. In one of those eight outbreaks, an external source of contamination was identified and elevated levels of faecal indicator bacteria (FIB) were noted in water. In the remaining outbreaks, FIB analyses were insufficient to describe the hygienic quality of the water. Restrictions against bathing proved effective in controlling the outbreaks. In spring 2015, the National Institute for Health and Welfare (THL) and the National Supervisory Authority for Welfare and Health (Valvira) published guidelines for outbreak control to prevent bathing water outbreaks.
Pathogenetics | 2017
Ari Kauppinen; Ilkka T. Miettinen
Human norovirus (NoV) causes waterborne outbreaks worldwide suggesting their ability to persist and survive for extended periods in the environment. The objective of this study was to determine the persistence of the NoV GII genome in drinking water and wastewater at three different temperatures (3 °C, 21 °C, and 36 °C). The persistence of two NoV GII inoculums (extracted from stool) and an indigenous NoV GII were studied. The samples were collected for up to one year from drinking water and for up to 140 days from wastewater. Molecular methods (RT-qPCR) were used to assess the decay of the NoV genome. Decay rate coefficients were determined from the fitted decay curves using log-linear and/or non-linear model equations. Results showed significant differences in the decay kinetics of NoV genome between the temperatures, matrices, and virus strains. The persistence of NoV was higher in drinking water compared to wastewater, and the cold temperature assisted persistence at both matrices. Differences between the persistence of NoV strains were also evident and, particularly, indigenous NoVs persisted better than spiked NoVs in wastewater. The decay constants obtained in this study can be utilized to assess the fate of the NoV genome in different water environments.
Journal of Water and Health | 2018
Ananda Tiwari; Anna-Maria Hokajärvi; Jorge W. Santo Domingo; Ari Kauppinen; Michael Elk; Hodon Ryu; Balamuralikrishna Jayaprakash; Tarja Pitkänen
Intestinal enterococci indicate the fecal contamination of bathing waters. This study defines the performance characteristics of the reference method ISO 7899-2:2000 with water samples collected from inland and coastal bathing areas in Finland. From a total of 341 bacterial isolates grown on Slanetz and Bartley medium, 63.6% were confirmed as intestinal enterococci on bile aesculin agar. The partial 16S rRNA gene sequences showed that Enterococcus faecium and Enterococcus faecalis clades accounted for 93.1% of the confirmed isolates. The range of the false positive and false negative rate of the ISO 7899-2 was 0.0-18.5% and 5.6-57.1%, respectively, being affected by the presumptive colony count on the membrane. The analysis of multiple sample volumes is proposed to reach 10-100 colonies per membrane when 47 mm diameter membranes are used to prevent overestimation of low counts and underestimation of the high counts.
Food and Environmental Virology | 2018
Ari Kauppinen; Tarja Pitkänen; Ilkka T. Miettinen
publisher | None
author
Water | 2018
Kati Martikainen; Anna-Maria Veijalainen; Eila Torvinen; Helvi Heinonen-Tanski; Ari Kauppinen; Tarja Pitkänen; Ilkka T. Miettinen; Ville Matikka