Featured researches published by Armando Lopes Moreno Junior.
Ambiente Construído | 2012
Armando Lopes Moreno Junior; Julio Cesar Molina
There is a growing interest on the research on the structural safety under fire in Brazil, but some aspects that still need discussion. The simulation and laboratory evaluation of structural elements under a fire situation is one of those aspects, especially regarding the testing methodology. The Brazilian standard NBR 5628:2001 needs to be reviewed in order to adapt international methodologies to our reality or even to establish new methodologies, considering variables that are relevant in the local context. This paper provides a starting point for those discussions, by gathering the parameters that that guide the methodological procedures for the evaluation of structural elements in natural scale, under load, and in a fire situation. Relevant parameters, such as the minimum dimensions of the elements to be tested, rates of temperature rise with time, infrastructure for tests, instrumentation of the structural elements, among others, have been evaluated based on current national and international standardization. It is hoped that this work will make contributions for the future revision of the NBR 5628:2001 standard, and encourage Brazilian researchers to join this new and arduous research theme.
REM - International Engineering Journal | 2017
Fábio Masini Rodrigues; Armando Lopes Moreno Junior
The composite structures formed by the association of steel profiles with concrete have shown to be an advantageous alternative, improving the behavior of the steel structures concerning their load capacity, stiffness, and durability, under fire conditions. The concrete-filled tubular columns have become an attractive alternative for the civil construction area, offering constructive and esthetic advantages. The Eurocode 4 (EN 1994-1-2, 2002) and ABNT NBR 14323:2013 show simple methods for the design of the composite columns under fire situations. Nevertheless, these present limitations in their application. In addition, regarding the determination of the temperature field in the cross section, the Eurocode 4 (EN 1994-1-2, 2002) describes a specific procedure for columns with section profile covered with concrete, but it is neglectful about concrete-filled tubular columns. The goal of this paper is to present a simplified procedure to determine the temperature registered in concrete-filled steel columns and apply the procedure to columns with square section tubes. The temperature distribution was determined by simulations using the computer package ABAQUS (Dessault Systemes Simulia Corp. 2013). After the studies, it has been considered that the procedure described in this paper is an effective alternative for the determination of the field’s temperature and for the application of the design of the concrete-filled columns under fire conditions.
Ambiente Construído | 2015
Cassiano da Silva Zago; Armando Lopes Moreno Junior; Marcelo Cuadrado Marin
A crescente utilizacao do concreto pre-moldado para solucao estrutural em diversas obras, como edificacoes industriais e comerciais, tornou-se uma alternativa vantajosa e acessivel, principalmente no quesito tempo de construcao. Porem, quando em situacao de incendio, determinadas caracteristicas que esse sistema construtivo usualmente oferece como vantagens podem tornar-se uma desvantagem. Contando com espacos amplos, com grandes vaos livres, materiais combustiveis armazenados e ventilacao apropriada, torna-se um cenario ideal para a propagacao de um incendio e consequente perda da capacidade de suporte da estrutura. Neste trabalho sao apresentadas as implicacoes de um projeto que utiliza o concreto pre-moldado em situacao de incendio, alem de levantar pontos para discussoes sobre possibilidades que amenizem os riscos, tendo como base referencias bibliograficas nacionais e internacionais, de uso corrente no meio tecnico e academico.
Rem-revista Escola De Minas | 2013
Armando Lopes Moreno Junior; Julio Cesar Molina; Carlito Calil Junior
This paper presents the parameters that guide the design of laboratory equipment to evaluate slabs and beams, in full-scale load, and in fire. Parameters of interest such as the internal dimensions, rate of temperature rise according to the time, infrastructure for installation of equipment, among others, are evaluated based on national and international standards. In the end, it is hoped that this report about the exercise of design and construction of the first horizontal Brazilian furnace encourage the future construction of this kind of equipment, helping national and international researchers in the area to start a similar, and arduous, task.
Engenharia Agricola | 2011
Gisleiva Cristina dos Santos Ferreira; Armando Lopes Moreno Junior
This study presents the results of an experimental investigation in characterizing the properties of cement soil block masonry using cement-soil mortars and PVA glue. The study deals with the scantily explored area of tensile bond strength of soil-cement block masonry using cement-soil mortars and PVA glue. Flexural bond strength of masonry has been determined by testing stack-bonded prisms using a bond wrench test set-up. The study clearly demonstrates the superiority of cement-soil mortar over other conventional mortar such as cement mortar. The results of this study can be conveniently used to select a proportion for cement-soil mortar or PVA glue proportion for cement soil block masonry structures.
Revista IBRACON de Estruturas e Materiais | 2013
Andre Penteado Tramontin; Armando Lopes Moreno Junior
As fissuras na interface alvenaria-estrutura sao comuns e pouco se conhece a respeito da sua ocorrencia, embora sejam frequentes, especialmente as que aparecem na ligacao alvenaria-pilar de concreto. O objetivo deste trabalho foi estudar a melhor tecnica de ancoragem entre alvenaria-estrutura, avaliando sua eficiencia no combate a esse tipo de fissura. Foram utilizados para a elaboracao dos ensaios, alem dos materiais usados na alvenaria de vedacao (bloco cerâmico, argamassa etc), diferentes materiais de ancoragem (tela metalica eletrosoldada e barras de aco) e dispositivos de ligacao (adesivo epoxi, pinos, arruelas e cantoneira), analisando-se assim o melhor conjunto do ponto de vista tecnico. Foram feitos ensaios de caracterizacao dos materiais e de arrancamento a tracao direta, ate a ocorrencia da primeira fissura visivel a olho nu. Concluiu-se finalmente que a tela metalica eletrosoldada galvanizada malha 15 x 15 mm e diâmetro do fio 1,65 mm, sem cantoneira e com tratamento de chapisco com adesivo acrilico no pilarete foi a melhor tecnica de ancoragem para a prevencao do aparecimento de fissuras na interface alvenaria de vedacao e pilar de concreto Abstract
Rem-revista Escola De Minas | 2012
Augusto Ottoni Bueno da Silva; Armando Lopes Moreno Junior; Gisleiva Cristina dos Santos Ferreira
Para se projetar um reforco a flexao com material polimerico reforcado com fibras, em uma viga de concreto armado, e necessario que o engenheiro responsavel opte por trabalhar sem a utilizacao de mecanismos de incremento de ancoragem, obviamente dentro de niveis seguros, ou utilize artificios que lhe garantam alcancar a deformacao ultima de projeto da fibra fornecida pelo fabricante da manta. Nesse artigo, e apresentada a base para o calculo das duas metodologias, segundo os criterios mais expressivos existentes, e sao feitas comparacoes com resultados experimentais. Para o reforco sem ancoragem, verificou-se que, para se evitarem as indesejadas rupturas prematuras e bruscas, as metodologias propostas pelos ACI e FIB mostraram-se adequadas. Para se garantir a deformacao ultima da fibra, foi estudado um mecanismo com ancoragem lateral a 45° feito com o proprio material da fibra. Nesse caso, utilizou-se o processo de secoes balanceadas, para a previsao do modo de ruptura, e, em seguida, foram feitas as devidas comparacoes entre os valores esperados com os resultados obtidos nos ensaios em laboratorio.
Rem-revista Escola De Minas | 2012
Eunice Sumie Ando; Armando Lopes Moreno Junior; Clayton Reis de Oliveira
In this paper the technique of strengthening reinforced concrete beams to prevent the bending phenomenon by increasing the thickness in the compressed chord region is evaluated. Two reinforced concrete beams with identical longitudinal and transversal dimensions and fixings, were molded. After twenty-eight days, one of these beams was reinforced with a layer of high-resistant concrete in the compressed region. A third beam was single-stage molded using both types of concrete and had the final characteristics of the previously reinforced beam. Finally, the rupture behavior of the three beams was analyzed, proving the efficiency of the reinforcement technique proposal.
Archive | 2007
Gisleiva Cristina dos Santos Ferreira; Armando Lopes Moreno Junior
Archive | 2006