The Journal of Nuclear Medicine | 2010
Andreas Boss; Sotirios Bisdas; Armin Kolb; Matthias Hofmann; Ulrike Ernemann; Claus D. Claussen; Christina Pfannenberg; Bernd J. Pichler; Matthias Reimold; Lars Stegger
Simultaneous PET and MRI using new hybrid PET/MRI systems promises optimal spatial and temporal coregistration of structural, functional, and molecular image data. In a pilot study of 10 patients with intracranial masses, the feasibility of tumor assessment using a PET/MRI system comprising lutetium oxyorthosilicate scintillators coupled to avalanche photodiodes was evaluated, and quantification accuracy was compared with conventional PET/CT datasets. Methods: All measurements were performed with a hybrid PET/MRI scanner consisting of a conventional 3-T MRI scanner in combination with an inserted MRI-compatible PET system. Attenuation correction of PET/MR images was computed from MRI datasets. Diagnoses at the time of referral were low-grade astrocytoma (n = 2), suspicion of low-grade astrocytoma (n = 1), anaplastic astrocytoma (World Health Organization grade III; n = 1), glioblastoma (n = 2), atypical neurocytoma (n = 1), and meningioma (n = 3). In the glial tumors, 11C-methionine was used for PET; in the meningiomas, 68Ga-DOTATOC was administered. Tumor–to–gray matter and tumor–to–white matter ratios were calculated for gliomas, and tracer uptake of meningiomas was referenced to nasal mucosa. PET/MRI was performed directly after clinically indicated PET/CT examination. Results: In all patients, the PET datasets showed similar diagnostic image quality on the hybrid PET/MRI and the PET/CT studies; however, slight streak artifacts were visible in coronal and sagittal sections when using the higher intrinsic resolution of the PET/MRI insert. Prefiltering of images with a 4-mm gaussian filter at a resolution comparable to that of the PET/CT system virtually eliminated these artifacts. Although acquisition of the PET/MR images started at 30–60 min after PET/CT (20.4-min half-life of 11C) acquisition, the signal-to-noise ratio was good enough, thus underlining the high sensitivity of the PET insert, compared with whole-body PET systems. The computed tumor–to–reference tissue ratios exhibited an excellent accordance between the PET/MRI and PET/CT systems, with a Pearson correlation coefficient of 0.98. Mean paired relative error was 7.9% ± 12.2%. No significant artifacts or distortions were detected in the simultaneously acquired MR images using the PET/MRI scanner. Conclusion: Structural, functional, and molecular imaging in patients with brain tumors is feasible with diagnostic imaging quality using simultaneous hybrid PET/MR image acquisition.
Seminars in Nuclear Medicine | 2008
Bernd J. Pichler; Armin Kolb; Martin S. Judenhofer
Multimodal imaging is now well-established in routine clinical practice. Especially in the field of nuclear medicine, new positron emission tomography (PET) installations comprise almost exclusively combined PET/computed tomography (CT) scanners rather than PET-only systems. However, PET/CT has certain notable shortcomings, including the inability to perform simultaneous data acquisition and the significant radiation dose to the patient contributed by CT. Magnetic resonance imaging (MRI) offers, compared with CT, better contrast among soft tissues as well as functional-imaging capabilities. Therefore, the combination of PET with MRI provides many advantages that go far beyond simply combining functional PET information with structural MRI information. Many technical challenges, including possible interference between these modalities, have to be solved when combining PET and MRI, and various approaches have been adapted to resolving these issues. Here, we present an overview of current working prototypes of combined PET/MRI scanners from different groups. In addition, besides PET/MRI images of mice, the first such images of a rat acquired with the first commercial clinical PET/MRI scanner, are presented. The combination of PET and MRI is a promising tool in preclinical research and will certainly progress to clinical application.
European Radiology | 2011
Andreas Boss; Lars Stegger; Sotirios Bisdas; Armin Kolb; Nina F. Schwenzer; Markus Pfister; Claus D. Claussen; Bernd J. Pichler; Christina Pfannenberg
ObjectiveThe aim of this pilot study was to test and demonstrate the feasibility of simultaneous positron emission tomography (PET) and magnetic resonance imaging (MRI) of the head and upper neck area using a new hybrid PET/MRI system.MethodsEight patients with malignant head and neck tumours were included in the pilot study. Directly after routine PET/CT imaging with a whole-body system using the glucose derivative 2-[18F]fluoro-2deoxy-D-glucose (FDG) as a radiotracer additional measurements were performed with a prototype PET/MRI system for simultaneous PET and MR imaging. Physiological radiotracer uptake within regular anatomical structures as well as tumour uptake were evaluated visually and semiquantitatively (metabolic ratios) in relation to cerebellar uptake on the PET/MRI and PET/CT systems.ResultsThe MR datasets showed excellent image quality without any recognisable artefacts caused by the inserted PET system. PET images obtained with the PET/MRI system exhibited better detailed resolution and greater image contrast in comparison to those from the PET/CT system. An excellent agreement between metabolic ratios obtained with both PET systems was found: R = 0.99 for structures with physiological tracer uptake, R = 0.96 for tumours.ConclusionSimultaneous PET/MRI of the head and upper neck area is feasible with the new hybrid PET/MRI prototype.
Trends in Molecular Medicine | 2010
Alexander Sauter; Armin Kolb; Martin S. Judenhofer; Bernd J. Pichler
Given the need for sophisticated in vivo detection techniques to better characterize the cellular and subcellular processes in animals and humans, molecular imaging has become an important discipline. Techniques in molecular imaging have developed from stand alone modalities to multimodality methods. Among these, the combination of positron emission tomography (PET) and computed tomography (CT) is a successful imaging method and has become an important tool in clinical practice. Technological approaches that combine magnetic resonance imaging (MRI) with diffuse optical tomography (DOT), fluorescence tomography (FT) and PET have now been introduced. PET/MRI and the resulting combination of molecular, morphological and functional information will pave the way for a better understanding of physiological and disease mechanisms in preclinical and clinical settings.
Physics in Medicine and Biology | 2010
Armin Kolb; E. Lorenz; Martin S. Judenhofer; Dieter Renker; Konrad Lankes; Bernd J. Pichler
This paper presents an evaluation of two types of Geiger-mode avalanche photodiodes (G-APDs) for their potential to be used in a positron emission tomography (PET) detector. While the MPPC G-APD had only 3600 cells, the solid state photomultiplier (SSPM)-type G-APD had 8100 cells. In a single-channel G-APD/LSO setup, the energy resolution (DeltaEpsilon/Epsilon) of the SSPM at 511 keV was 25%, while the (DeltaEpsilon/Epsilon) of the MPPC was 13.5% (FWHM). No influences were observed while the detectors were inside a 7 T magnetic resonance (MR) scanner. A time resolution of 2.7 ns (FWHM) was measured for the LSO/SSPM and 0.9 ns for the LSO/MPPC detector setup. Although the linearity was superior for the SSPM in the single detector readout, the inferior energy and time resolution excluded them to be used for the block detector readout. All 12 x 12 LSO crystals of the block could be resolved in a crystal map using a 3 x 3 MPPC G-APD array. The time resolution of the block detector was 950 ps. While the energy spectra for the MPPC-based single-channel setup were nonlinear, they reached linearity better than 5% in the block detector. A high number of G-APD cells provide a linear signal in a single-channel detector setup, but not necessarily a good timing or (DeltaEpsilon/Epsilon) due to a larger inactive surface resulting in lower photon detection efficiency. G-APDs with a low number of cells provide a good timing and (DeltaEpsilon/Epsilon) and linear signals in block detector designs, where the scintillation light is shared over many G-APDs.
European Journal of Radiology | 2012
Nina F. Schwenzer; Lars Stegger; Sotirios Bisdas; Christina Schraml; Armin Kolb; Andreas Boss; M. Müller; Matthias Reimold; Ulrike Ernemann; Claus D. Claussen; Christina Pfannenberg; Holger Schmidt
OBJECTIVES The present work illustrates the current state of image quality and diagnostic accuracy in a new hybrid BrainPET/MR. MATERIALS AND METHODS 50 patients with intracranial masses, head and upper neck tumors or neurodegenerative diseases were examined with a hybrid BrainPET/MR consisting of a conventional 3T MR system and an MR-compatible PET insert. Directly before PET/MR, all patients underwent a PET/CT examination with either [18F]-FDG, [11C]-methionine or [68Ga]-DOTATOC. In addition to anatomical MR scans, functional sequences were performed including diffusion tensor imaging (DTI), arterial spin labeling (ASL) and proton-spectroscopy. Image quality score of MR imaging was evaluated using a 4-point-scale. PET data quality was assessed by evaluating FDG-uptake and tumor delineation with [11C]-methionine and [68Ga]-DOTATOC. FDG uptake quantification accuracy was evaluated by means of ROI analysis (right and left frontal and temporo-occipital lobes). The asymmetry indices and ratios between frontal and occipital ROIs were compared. RESULTS In 45/50 patients, PET/MR examination was successful. Visual analysis revealed a diagnostic image quality of anatomical MR imaging (mean quality score T2 FSE: 1.27±0.54; FLAIR: 1.38±0.61). ASL and proton-spectroscopy was possible in all cases. In DTI, dental artifacts lead to one non-diagnostic dataset (mean quality score DTI: 1.32±0.69; ASL: 1.10±0.31). PET datasets of PET/MR and PET/CT offered comparable tumor delineation with [11C]-methionine; additional lesions were found in 2/8 [(68)Ga]-DOTATOC-PET in the PET/MR. Mean asymmetry index revealed a high accordance between PET/MR and PET/CT (1.5±2.2% vs. 0.9±3.6%; mean ratio (frontal/parieto-occipital) 0.93±0.08 vs. 0.96±0.05), respectively. CONCLUSIONS The hybrid BrainPET/MR allows for molecular, anatomical and functional imaging with uncompromised MR image quality and a high accordance of PET results between PET/MR and PET/CT. These results justify the application of this technique in further clinical studies and may contribute to the transfer into whole-body PET/MR systems.
International Journal of Radiation Oncology Biology Physics | 2011
Daniela Thorwarth; Guido Henke; Arndt-Christian Müller; Matthias Reimold; Thomas Beyer; Andreas Boss; Armin Kolb; Bernd J. Pichler; Christina Pfannenberg
PURPOSE To evaluate intensity-modulated radiotherapy (IMRT) treatment planning based on simultaneous positron-emission tomography and magnetic resonance imaging (PET/MRI) of meningioma. METHODS AND MATERIALS A meningioma patient was examined prior to radiotherapy with dedicated planning computed tomography (CT), MRI, PET/CT with gallium-68-labeled DOTATOC (68Ga-DOTATOC), and simultaneous 68Ga-DOTATOC-PET/MRI. The first gross target volume (GTV) was defined based on a combination of separate MR and 68Ga-DOTATOC-PET/CT imaging (GTVPET/CT+MR). Then, the simultaneous PET/MR images were used to delineate a second GTV (GTVPET/MR) by following exactly the same delineation strategy. After an isotropic expansion of those volumes by a 4-mm safety margin, the resulting planning target volumes (PTVs) were compared by calculating the intersection volume and the relative complements. A cross-evaluation of IMRT plans was performed, where the treatment plan created for the PTVPET/CT+MR was applied to the PET/MR-based PTVPET/MR. RESULTS Generally, target volumes for IMRT treatment planning did not differ between MRI plus 68Ga-DOTATOC-PET/CT and simultaneous PET/MR imaging. Only in certain regions of the GTV were differences observed. The overall volume of the PET/MR-based PTV was approximately the same as that obtained from PET/CT data. A small region of infiltrative tumor growth next to the main tumor mass was better visualized with combined PET/MR due to smaller PET voxel sizes and improved recovery. An IMRT treatment plan was optimized for the PTVPET/CT+MR. The evaluation of this plan with respect to the PTVPET/MR showed parts of the target volume that would not have received the full radiation dose after delineation of the tumor, based on simultaneous PET/MR. CONCLUSION This case showed that differences in target volumes delineated on the basis of separate MR and PET/CT and simultaneous PET/MR may be observed that can have significant consequences for an effectively applied radiotherapy treatment plan.
Investigative Radiology | 2010
Andreas Boss; Armin Kolb; Matthias Hofmann; Sotirios Bisdas; Thomas Nägele; Ulrike Ernemann; Lars Stegger; Cristina Rossi; Heinz Peter Schlemmer; Christina Pfannenberg; Matthias Reimold; Claus D. Claussen; Bernd J. Pichler; Uwe Klose
Purpose:The aim of this study was to test and demonstrate the feasibility of diffusion tensor imaging (DTI) with a hybrid positron emission tomography (PET)/magnetic resonance imaging system for simultaneous PET and magnetic resonance (MR) data acquisition. Materials and Methods:All measurements were performed with a prototype hybrid PET/MR scanner dedicated for brain and head imaging. The PET scanner, which is inserted into a conventional 3.0-Tesla high field MR imager equipped with a transmit/receive birdcage head coil, consists of 192 block detectors with a matrix of 12 × 12 lutetium oxyorthosilicate scintillation crystals combined with MR-compatible 3 × 3 avalanche photodiode arrays. In 7 volunteers and 4 patients with brain tumors, DTI was performed during simultaneous PET data readout applying a diffusion weighted echo planar sequence (12 noncollinear directions, echo time (TE)/repetition time (TR) 98 ms/5300 ms, b-value 800 s/mm2). Image quality and accuracy of DTI were assessed in comparison with DTI images acquired after removal of the PET insert. Results:The diffusion images showed good image quality in all volunteers regardless of simultaneous PET data readout or after removal of the PET scanner; however, significantly (P < 0.01) stronger rim artifacts were found in fractional anisotropy images computed from DTI images recorded during simultaneous PET acquisition, demonstrating higher eddy-current effects. In region of interest analysis, no notable differences were found in the computation of the direction of the principal eigenvector (P > 0.05) and fractional anisotropy values (P > 0.05). In the assessment of pathologies, in all 4 patients PET and DTI provided important clinical information in addition to conventional magnetic resonance imaging. Conclusion:Diffusion tensor imaging may be combined with simultaneous PET data acquisition, offering additional important morphologic and functional information for treatment planning in patients with brain tumors.
The Journal of Nuclear Medicine | 2014
Jonathan A. Disselhorst; Ilja Bezrukov; Armin Kolb; Christoph Parl; Bernd J. Pichler
Hybrid PET/MR systems have rapidly progressed from the prototype stage to systems that are increasingly being used in the clinics. This review provides an overview of developments in hybrid PET/MR systems and summarizes the current state of the art in PET/MR instrumentation, correction techniques, and data analysis. The strong magnetic field requires considerable changes in the manner by which PET images are acquired and has led, among others, to the development of new PET detectors, such as silicon photomultipliers. During more than a decade of active PET/MR development, several system designs have been described. The technical background of combined PET/MR systems is explained and related challenges are discussed. The necessity for PET attenuation correction required new methods based on MR data. Therefore, an overview of recent developments in this field is provided. Furthermore, MR-based motion correction techniques for PET are discussed, as integrated PET/MR systems provide a platform for measuring motion with high temporal resolution without additional instrumentation. The MR component in PET/MR systems can provide functional information about disease processes or brain function alongside anatomic images. Against this background, we point out new opportunities for data analysis in this new field of multimodal molecular imaging.
The Journal of Nuclear Medicine | 2015
Armin Kolb; Alexander Sauter; Lars Eriksson; Arne Vandenbrouke; Chih-Chieh Liu; Craig S. Levin; Bernd J. Pichler; M. Rafecas
Simultaneous PET/MR imaging is an emerging hybrid modality for clinical and preclinical imaging. The static magnetic field of the MR imaging device affects the trajectory of the positrons emitted by the PET radioisotopes. This effect translates into an improvement of the spatial resolution in transaxial images. However, because of the elongation of the positron range distribution along the magnetic field, the axial resolution worsens and shine-through artifacts may appear. These artifacts can lead to misinterpretation and overstaging. The aim of this work was to study the relevance of this effect. Methods: Measurements were performed in a 3-tesla PET/MR scanner. A 1-cm2 piece of paper, soaked with a radioisotope and placed in air, was scanned, and the magnitude of the shine-through was quantified from the PET images for various radioisotopes. Additionally, PET/MR and PET/CT images of the lungs and the larynx with trachea of a deceased swine were obtained after injecting a mixture of NiSO4 and 68Ga to simulate hot tumor lesions. Results: For the radioactive paper, shine-through artifacts appeared in the location of the acrylic glass backplane, located 3 cm from the source in the axial direction. The ratio between the activity of the shine-through and the activity reconstructed in the original location ranged from 0.9 (18F) to 5.7 (68Ga). For the larynx-with-trachea images, the magnitude of the artifacts depended on the organ orientation with respect to the magnetic field. The shine-through activity could reach 46% of the reconstructed activity (larynx lesion). The lesion within the trachea produced 2 artifacts, symmetrically aligned with the magnetic field and characterized by artifact-to-lesion volume-of-interest ratios ranging from 21% to 30%. Conclusion: In simultaneous PET/MR imaging, the effect of the magnetic field on positrons may cause severe artifacts in the PET image when the lesions are close to air cavities and high-energy radioisotopes are used. For accurate staging and interpretation, this effect needs to be recognized and adequate compensation techniques should be developed.