Journal of Instrumentation | 2014
K. Mitton; Ashley Richard Jones; Malcolm J. Joyce
Neutron imaging has previously been used in order to test for cracks, degradation and water content in concrete. However, these techniques often fall short of alternative non-destructive testing methods, such as γ-ray and X-ray imaging, particularly in terms of resolution. Further, thermal neutron techniques can be compromised by the significant expense associated with thermal neutron sources of sufficient intensity to yield satisfactory results that can often precipitate the need for a reactor. Such embodiments are clearly not portable in the context of the needs of field applications. This paper summarises the results of a study to investigate the potential for transmission radiography based on fast neutrons. The objective of this study was to determine whether the presence of heterogeneities in concrete, such as reinforcement structures, could be identified on the basis of variation in transmitted fast-neutron flux. Monte-Carlo simulations have been performed and the results from these are compared to those arising from practical tests using a 252Cf source. The experimental data have been acquired using a digital pulse-shape discrimination system that enables fast neutron transmission to be studied across an array of liquid scintillators placed in close proximity to samples under test, and read out in real time. Whilst this study does not yield sufficient spatial resolution, a comparison of overall flux ratios does provide a basis for the discrimination between samples with contrasting rebar content. This approach offers the potential for non-destructive testing that gives less dose, better transportability and better accessibility than competing approaches. It is also suitable for thick samples where γ-ray and X-ray methods can be limited.
IEEE Transactions on Nuclear Science | 2017
Michael Aspinall; Malcolm J. Joyce; Anthony Lavietes; Romano Plenteda; Francis D. Cave; Helen Parker; Ashley Richard Jones; Vytautas Astromskas
Scintillation detectors offer a single-step detection method for fast neutrons and necessitate real-time acquisition, whereas this is redundant in two-stage thermal detection systems using helium-3 and lithium-6, where the fast neutrons need to be thermalized prior to detection. The relative affordability of scintillation detectors and the associated fast digital acquisition systems have enabled entirely new measurement setups that can consist of sizeable detector arrays. These detectors in most cases rely on photomultiplier tubes, which have significant tolerances and result in variations in detector response functions. The detector tolerances and other environmental instabilities must be accounted for in measurements that depend on matched detector performance. This paper presents recent advances made to a high-speed FPGA-based digitizer. The technology described offers a complete solution for fast-neutron scintillation detectors by integrating multichannel high-speed data acquisition technology with dedicated detector high-voltage supplies. This configuration has significant advantages for large detector arrays that require uniform detector responses. We report on bespoke control software and firmware techniques that exploit real-time functionality to reduce setup and acquisition time, increase repeatability, and reduce statistical uncertainties.
nuclear science symposium and medical imaging conference | 2015
Christopher Payne; P.J. Sellin; Mark Ellis; Kirk Duroe; Ashley Richard Jones; Malcolm J. Joyce; George Randall; Robert D. Speller
The effect of scintillator geometry on the quality of neutron/γ pulse shape discrimination (PSD) in EJ-299 plastic scintillator, using a digital charge integration PSD algorithm has been studied. It is shown that the PSD Figure of Merit (FOM) reduces as the geometry of the scintillator moves from a cube-like shape towards a flat panel shape. The PSD performance in this material at high flux irradiation is investigated with performance deteriorating at rates of ~107 photons/s. The use of EJ-299 for security applications, with a focus on active interrogation environments is explored in conjunction with a system capable of neutron/γ separation and localisation.
Journal of Instrumentation | 2017
Ashley Richard Jones; Malcolm J. Joyce
Liquid scintillators are used widely for neutron detection and for the assay of nuclear materials. However, due to the constituents of the detector and the nitrogen void within the detector cell, usually incorporated to accommodate any expansion that might occur to avoid leakage, fluctuations in detector response have been observed associated with the orientation of the detector when in use. In this work the angular dependence of the pulse-shape discrimination performance in an EJ309 liquid scintillator has been investigated with 252Cf in terms of the separation of γ-ray and neutron events, described quantitatively by the figure-of-merit. A subtle dependence in terms of pulse-shape discrimination is observed. In contrast, a more significant dependence of detection sensitivity with the angle of orientation is evident.
international conference on advancements in nuclear instrumentation measurement methods and their applications | 2013
Ashley Richard Jones; Malcolm J. Joyce
The possibility of discriminating between neutrons and γ rays on the basis of differences in the rising edge of corresponding pulses from organic scintillation detectors is described. It has long been known that radiation type can be discerned on the basis of subtle differences in pulse shape from a variety of detection materials, but discrimination in fast organic scintillators has long been reliant on the separation in decay face of the pulse. This can constrain pulse-shape discrimination techniques to follow after the peak amplitude of the event and they can thus be more susceptible to the effects of pile up. Furthermore, discrimination in the decay face places a fundamental limit on the time relative to the evolution of the event when discrimination can be performed and thus this can be a significant constraint on the event processing rate for high pulse-rate applications. In this paper the correspondence between established mathematical models of organic pulse shape and real events in the rising edge part of the event is investigated, and the potential for rise-time based pulse-shape discrimination in mixed-field data from organic scintillators is explored. Special nuclear materials (SNM) are of particular interest to security surveillance and based on active interrogation. Active interrogation involves neutrons hitting a material that is fissile, and detecting the emitted γ rays and neutrons to try and classify materials. Faster, more efficient and more transportable devices are being sought to help in the prevention of illicit transport of nuclear materials. SNM are difficult to detect due to high-flux γ emissions, and very low neutron signatures.
Review of Scientific Instruments | 2018
Ashley Richard Jones; Michael Aspinall; Malcolm J. Joyce
A detector system for the characterization of radiation fields of both fast neutrons and γ rays is described comprising of a gated photomultiplier tube (PMT), an EJ299-33 solid organic scintillator detector, and an external trigger circuit. The objective of this development was to conceive a means by which the PMT in such a system can be actuated remotely during the high-intensity bursts of pulsed γ-ray contamination that can arise during active interrogation procedures. The system is used to detect neutrons and γ rays using established pulse-shape discrimination (PSD) techniques. The gating circuit enables the PMT to be switched off remotely. This is compatible with use during intense radiation transients to avoid saturation and the disruption of the operation of the PMT during the burst. Data are presented in the form of pulse-height spectra and PSD scatter plots for the system triggered with a strobed light source. These confirm that the gain of the system and the throughput for both triggered and un-triggered scenarios are as expected, given the duty cycle of the stimulating radiation. This demonstrates that the triggering function does not perturb the system response of the detector.
nuclear science symposium and medical imaging conference | 2016
Ashley Richard Jones; Arron Griffiths; Malcolm J. Joyce; Barry Lennox; Simon Watson; Jun-ichi Katakura; Keisuke Okumura; Kangsoo Kim; Michio Katoh; Kazuya Nishimura; Ken-ichi Sawada
The premise behind this research is the design of a system that will allow fuel debris characterisation at Fukushima Daiichi. The precise location of the debris is not known for example as to whether it remains within the reactor pressure vessel or it has leaked through into the base of the pedestal below, additionally the state of the fuel is also in question as to whether this has corroded from within its encasing or if it is intact. The most likely scenario is a combination of all four of these situations. The flooding of the reactor floors immediately following the Fukushima accident adds an extra element of complexity for the detection system requiring it to be submersible and to hold any detector system in water tight confinement. The research carried out has involved extensive modifications to a previously-designed low-cost small-scale AVEXIS submersible inspection vehicle and the incorporation of a variety of radiation detectors. The latter has been designed to allow for mapping and determination of the situation that is present within the primary containment vessels. The challenges addressed with the detection system arise from the high dose rates that have been recorded around the reactor pressure vessels which can be as high as 1000 Gy/hr. In such a harsh environment not only will the radiation detectors struggle to operate but the components that make up the remote-operated vehicle are also likely to suffer radiation damage after only a relatively short period of time. The research presented here evaluates the components currently incorporated into the AVEXIS system in terms of their radiation tolerability as well as presenting the combination of detectors to be used in the remote probe for the investigation of the fuel debris.
nuclear science symposium and medical imaging conference | 2015
George Randall; Mark Ellis; Kirk Duroe; Ashley Richard Jones; Malcolm J. Joyce; Christopher Payne; P.J. Sellin; Robert D. Speller
A variation of the RadICAL (Radiation Imaging Cylinder Activity Locator) system capable of operating in a dynamic environment, such as that created by active interrogation techniques, has been developed. RadICAL is a novel method for locating a radiological source using a rotating detector element. The detector geometry is that of a thin sheet and is rotated to present a constantly changing surface area to the source; it therefore generates a characteristic temporal response which can be used to determine the source direction. The time required to determine the direction of a source make it unsuitable for dynamic environments and so an alternative method is presented that uses a stack of identical scintillator slabs positioned at fixed horizontal angles around a central axis. By comparing count rates from each slab to a standard response curve, using a specially developed algorithm, the direction of a source can be determined without the need to rotate the detector. EJ-299-33 plastic scintillator was used to allow detection of separate neutron and gamma events in a mixed field through pulse shape discrimination. A four element detector was built and shown to achieve a positional accuracy of approximately 4.4 degrees when exposed to a 1.44MBq 137 Cs source at distances of up to 2m. The same detector was used to discriminate separate neutron and gamma events in a mixed field, which allows for the possibility of locating a neutron source within a gamma rich environment.
international conference on advancements in nuclear instrumentation measurement methods and their applications | 2015
Helen Parker; Malcolm J. Joyce; Ashley Richard Jones
It is well documented that 238U decays by spontaneous fission, and that it is the main component of most nuclear fuels. As nuclear fuels are largely classed as Special Nuclear Material (SNM), they have to be fully accounted for by owners and processing facilities. One possible method for verifying declared amounts of SNM is to count the spontaneous neutrons produced from 238U. Using four EJ-309 liquid scintillation detectors and a mixed field analyser, spontaneous neutrons from 16.4 g of depleted uranium (0.3% enrichment) have been assayed. The assay method shows promising results and this proof of principle will be researched further in order for it to be applied in an industrial setting.
Archive | 2018
So Kamada; Michio Katoh; Kazuya Nishimura; Matthew Nancekievill; Simon Watson; Barry Lennox; Ashley Richard Jones; Malcolm J. Joyce; Keisuke Okumura; Jun-ichi Katakura