Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Ayako Kanazawa is active.

Publication


Featured researches published by Ayako Kanazawa.


Science of The Total Environment | 2010

Relationship between selected indoor volatile organic compounds, so-called microbial VOC, and the prevalence of mucous membrane symptoms in single family homes

Atsuko Araki; Toshio Kawai; Yoko Eitaki; Ayako Kanazawa; Kanehisa Morimoto; Kunio Nakayama; Eiji Shibata; Masatoshi Tanaka; Tomoko Takigawa; Takesumi Yoshimura; Hisao Chikara; Yasuaki Saijo; Reiko Kishi

Microorganisms are known to produce a range of volatile organic compounds, so-called microbial VOC (MVOC). Chamber studies where humans were exposed to MVOC addressed the acute effects of objective and/or subjective signs of mucosal irritation. However, the effect of MVOC on inhabitants due to household exposure is still unclear. The purpose of this epidemiological study was to measure indoor MVOC levels in single family homes and to evaluate the relationship between exposure to them and sick building syndrome (SBS). All inhabitants of the dwellings were given a self-administered questionnaire with standardized questions to assess their symptoms. Air samples were collected and the concentrations of eight selected compounds in indoor air were analyzed by gas chromatography/mass spectrometry - selective ion monitoring mode (GC/MS-SIM). The most frequently detected MVOC was 1-pentanol at a detection rate of 78.6% and geometric mean of 0.60 microg/m(3). Among 620 participants, 120 (19.4%) reported one or more mucous symptoms; irritation of the eyes, nose, airway, or coughing every week (weekly symptoms), and 30 (4.8%) reported that the symptoms were home-related (home-related symptoms). Weekly symptoms were not associated with any of MVOC, whereas significant associations between home-related mucous symptoms and 1-octen-3-ol (per log(10)-unit: odds ratio (OR) 5.6, 95% confidence interval (CI): 2.1 to 14.8) and 2-pentanol (per log(10)-unit: OR 2.3, 95% CI: 1.0 to 4.9) were obtained after adjustment for gender, age, and smoking. Associations between home-related symptoms and 1-octen-3-ol remained after mutual adjustment. However, concentrations of the selected compounds in indoors were lower than the estimated safety level in animal studies. Thus, the statistically significant association between 1-octen-3-ol may be due to a direct effect of the compounds or the associations may be being associated with other offending compounds. Additional studies are needed to evaluate these possibilities.


Science of The Total Environment | 2014

Exposure to house dust phthalates in relation to asthma and allergies in both children and adults.

Yu Ait Bamai; Eiji Shibata; Ikue Saito; Atsuko Araki; Ayako Kanazawa; Kanehisa Morimoto; Kunio Nakayama; Masatoshi Tanaka; Tomoko Takigawa; Takesumi Yoshimura; Hisao Chikara; Yasuaki Saijo; Reiko Kishi

Although an association between exposure to phthalates in house dust and childhood asthma or allergies has been reported in recent years, there have been no reports of these associations focusing on both adults and children. We aimed to investigate the relationships between phthalate levels in Japanese dwellings and the prevalence of asthma and allergies in both children and adult inhabitants in a cross-sectional study. The levels of seven phthalates in floor dust and multi-surface dust in 156 single-family homes were measured. According to a self-reported questionnaire, the prevalence of bronchial asthma, allergic rhinitis, allergic conjunctivitis, and atopic dermatitis in the 2 years preceding the study was 4.7%, 18.6%, 7.6%, and 10.3%, respectively. After evaluating the interaction effects of age and exposure categories with generalized liner mixed models, interaction effects were obtained for DiNP and bronchial asthma in adults (Pinteraction=0.028) and for DMP and allergic rhinitis in children (Pinteraction=0.015). Although not statistically significant, children had higher ORs of allergic rhinitis for DiNP, allergic conjunctivitis for DEHP, and atopic dermatitis for DiBP and BBzP than adults, and liner associations were observed (Ptrend<0.05). On the other hand, adults had a higher OR for atopic dermatitis and DEHP compared to children. No significant associations were found in phthalates levels collected from multi-surfaces. This study suggests that the levels of DMP, DEHP, DiBP, and BBzP in floor dust were associated with the prevalence of allergic rhinitis, conjunctivitis, and atopic dermatitis in children, and children are more vulnerable to phthalate exposure via household floor dust than are adults. The results from this study were shown by cross-sectional nature of the analyses and elaborate assessments for metabolism of phthalates were not considered. Further studies are needed to advance our understanding of phthalate toxicity.


Science of The Total Environment | 2014

Detection and intake assessment of organophosphate flame retardants in house dust in Japanese dwellings.

Shuji Tajima; Atsuko Araki; Toshio Kawai; Tazuru Tsuboi; Yu Ait Bamai; Eiji Yoshioka; Ayako Kanazawa; Shi Cong; Reiko Kishi

The demand for phosphorus flame retardants (PFRs) has recently increased as an alternative to polybrominated diphenyl ether (PBDE). PFRs have been detected in house dust, but little is known about the concentrations of PFRs in private homes and the effects on human health. We measured the levels of 10 PFRs in indoor floor dust and upper surface dust from 128 Japanese dwellings of families with children in elementary school. The median (min-max) concentrations (μg/g) of PFRs were as follows: tris(2-butoxyethyl) phosphate (TBOEP), 30.88 (<0.61-936.65); tris(2-chloro-iso-propyl) phosphate (TCIPP), 0.74 (<0.56-392.52); and triphenyl phosphate (TPHP), 0.87 (<0.80-23.35). These values exceeded 50% detection rates, and the rates are median over the LOD in floor dust. The concentrations (μg/g) of TBOEP 26.55 (<0.61-1933.24), TCIPP 2.23 (<0.56-621.23), TPHP 3.13 (<0.80-27.47), tris(2-chloroethyl) phosphate (TCEP) 1.17 (<0.65-92.22), and tributyl phosphate (TNBP) 0.74 (<0.36-60.64) exceeded 50% detection rates in the upper surface dust. A significant positive correlation (P<0.05) between the concentrations of TCIPP and TBOEP was shown in floor dust and upper surface dust (n=48). Estimated median and 95th percentile daily intake was calculated for toddlers and elementary school children and was compared with reference dose values (RfD) from the literature. For TBOEP, the estimated 95th percentile intake from floor dust was 14% of RfD for toddlers and 4% for school children. The estimated intake from upper surface dust was somewhat lower. Estimated median intake of TBOEP and median intake for the other PFRs were less than 1% of the RfD. TBOEP, TCIPP and TPHP were the main PFRs in the dust. The median levels of PFRs are well below the RfD values.


Science of The Total Environment | 2012

The relationship between exposure to microbial volatile organic compound and allergy prevalence in single-family homes.

Atsuko Araki; Ayako Kanazawa; Toshio Kawai; Yoko Eitaki; Kanehisa Morimoto; Kunio Nakayama; Eiji Shibata; Masatoshi Tanaka; Tomoko Takigawa; Takesumi Yoshimura; Hisao Chikara; Yasuaki Saijo; Reiko Kishi

Microbial volatile organic compounds (MVOCs) are a type of VOCs produced by microorganisms. Exposure to 1-octen-3-ol, one of the known MVOCs, has been reported to reduce nasal patency and increase nasal lavage myeloperoxidase, eosinophil cationic proteins, and lysozymes in both experimental and field studies. We reported in a previous paper that 1-octen-3-ol exposure at home is associated with mucosal symptoms. In this study, our aim was to investigate the relationship between asthma and allergies and MVOC exposure in single-family homes. The subjects were 624 inhabitants of 182 detached houses in six regions of Japan. Air samples were collected using diffusive samplers, and the concentrations of eight selected MVOCs were analyzed using gas chromatography/mass spectrometry in selected-ion-monitoring mode. Each inhabitant of each of the dwellings was given a self-administered questionnaire. Among the 609 subjects who answered all of the questions about allergies, history of the medical treatment for asthma, atopic dermatitis, allergic rhinitis, and allergic conjunctivitis within the preceding two years was 4.8%, 9.9%, 18.2%, and 7.1%, respectively. A significant association between 1-octen-3-ol (per log(10) unit) and allergic rhinitis odds ratio (OR): 4.10, 95% confidence interval (CI): 1.71 to 9.80 and conjunctivitis (OR: 3.54, CI: 1.17 to 10.7) was found after adjusting for age, sex, tobacco, wall-to-wall carpeting, signs of dampness, history of treatment for hay fever, and other potentially relevant environmental factors. No relationships were found between any MVOCs and asthma or atopic dermatitis after the adjustment. The levels of MVOCs and airborne fungi were only weakly correlated. These results are consistent with previous studies that have associated higher levels of 1-octen-3-ol exposure with increased irritation of nasal and ocular mucosae. Although the indoor-air concentrations of 1-octen-3-ol found in this study were relatively low, we conclude that exposure to MVOC may be related to rhinitis and conjunctivitis.


Science of The Total Environment | 2014

Associations of phthalate concentrations in floor dust and multi-surface dust with the interior materials in Japanese dwellings

Yu Ait Bamai; Atsuko Araki; Toshio Kawai; Tazuru Tsuboi; Ikue Saito; Eiji Yoshioka; Ayako Kanazawa; Shuji Tajima; Cong Shi; Akiko Tamakoshi; Reiko Kishi

Phthalates are widely used as plasticizers in numerous products. However, there has been some concern about the various effects they may have on human health. Thus, household phthalate levels are an important public health issue. While many studies have assessed phthalate levels in house dust, the association of these levels with building characteristics has scarcely been examined. The present study investigated phthalate levels in house dust samples collected from the living areas of homes, and examined associations between these phthalate levels and the interior materials. Dust was collected from two portions of the living area: floor dust from the entire floor surface, and multi-surface dust from objects more than 35 cm above the floor. The levels of seven phthalates were measured using gas chromatography/mass spectrometry in selective ion monitoring mode. Phthalate levels were higher in multi-surface dust than in floor dust. Among floor dust samples, those from dwellings with compressed wooden flooring had significantly higher levels of di-iso-butyl phthalate compared to those with other floor materials, while polyvinyl chloride (PVC) flooring was associated with higher di-2-ethylhexyl phthalate (DEHP) levels. Among multi-surface dust samples, higher levels of DEHP and di-iso-nonyl phthalate (DINP) were found in samples from homes with PVC wallpaper than without. The number of PVC interior materials was significantly positively correlated with the levels of DEHP and DINP in multi-surface dust. The phthalate levels in multi-surface dust were associated with the interior surface materials, and those in floor dust were directly related to the flooring materials. Our findings show that when using house dust as an exposure assessment, it is very important to note where the samples were collected from. The present report provides useful information about the association between phthalates and dust inside dwellings, which will assist with establishing public health provisions.


Indoor Air | 2011

Relationships between mite allergen levels, mold concentrations, and sick building syndrome symptoms in newly built dwellings in Japan

Yasuaki Saijo; Ayako Kanazawa; Atsuko Araki; Kanehisa Morimoto; Kunio Nakayama; Tomoko Takigawa; Masatoshi Tanaka; Eiji Shibata; Takesumi Yoshimura; Hisao Chikara; Reiko Kishi

UNLABELLED This study investigated the possible relationships between exposures to mite allergen and airborne fungi with sick building syndrome (SBS) symptoms for residents living in newly built dwellings. We randomly sampled 5709 newly built dwellings in six prefectures from northern to southern Japan. A total of 1479 residents in 425 households participated in the study by completing questionnaire surveys and agreeing to environmental monitoring for mite allergen (Der 1), airborne fungi, aldehydes, and volatile organic compounds. Stepwise logistic regression analyses adjusted for confounders were used to obtain odds ratios (OR) of mite allergen and fungi for SBS symptoms. Der 1 had a significantly high OR for nose symptoms. Rhodotorula had a significantly high OR for any symptoms, and Aspergillus had significantly high OR for eye symptoms. However, the total colony-forming units had a significantly low OR for throat and respiratory symptoms. Eurotium had a significantly low OR for skin symptoms. In conclusion, dust-mite allergen levels and indoor airborne Rhodotorula and Aspergillus concentrations may result in SBS symptoms in newly built dwellings. PRACTICAL IMPLICATIONS Various factors can cause sick building syndrome symptoms. This study focused on biologic factors such as dust-mite allergen and airborne fungi in newly built dwellings in Japan. Dust-mite allergen levels were significantly associated with higher rates of nose symptoms, airborne Rhodotorula concentrations were significantly associated with higher rates of any symptoms, and Aspergillus concentrations were significantly associated with higher rates of eye symptoms. Measures should be taken to reduce mite allergen levels and fungal concentrations in these dwellings.


Journal of Epidemiology | 2014

Association of Mechanical Ventilation and Flue Use in Heaters With Asthma Symptoms in Japanese Schoolchildren: A Cross-Sectional Study in Sapporo, Japan

Shi Cong; Atsuko Araki; Shigekazu Ukawa; Yu Ait Bamai; Shuji Tajima; Ayako Kanazawa; Motoyuki Yuasa; Akiko Tamakoshi; Reiko Kishi

Background Use of fuel heaters is associated with childhood asthma. However, no studies have evaluated the associations of flue use and mechanical ventilation (ventilation) with asthma symptoms in schoolchildren. Methods This cross-sectional study investigated schoolchildren in grades 1 through 6 (age 6–12 years) in Sapporo, Japan. From November 2008 through January 2009, parents completed questionnaires regarding their home environment and their children’s asthma symptoms. Results In total, 4445 (69.5%) parents of 6393 children returned the questionnaire. After excluding incomplete responses, data on 3874 children (60.6%) were analyzed. The prevalence of current asthma symptoms and ever asthma symptoms were 12.8% and 30.9%, respectively. As compared with electric heaters, current asthma symptoms was associated with use of flued heaters without ventilation (OR = 1.62; 95% CI, 1.03–2.64) and unflued heaters with ventilation (OR = 1.77; 95% CI, 1.09–2.95) or without ventilation (OR = 2.23; 95% CI, 1.31–3.85). Regardless of dampness, unflued heaters were significantly associated with current asthma symptoms in the presence and absence of ventilation. Conclusions Use of unflued heaters was associated with current asthma symptoms, regardless of dampness. In particular, the prevalence of current asthma symptoms was higher in the absence of ventilation than in the presence of ventilation. Ever asthma symptoms was only associated with use of unflued heaters without ventilation. Consequently, use of fuel heaters, especially those that have no flue or ventilation, deserves attention, as their use might be associated with childhood asthma symptoms.


Indoor Air | 2010

Association between indoor exposure to semi‐volatile organic compounds and building‐related symptoms among the occupants of residential dwellings

Ayako Kanazawa; Ikue Saito; Atsuko Araki; Masamitsu Takeda; Mingyue Ma; Yasuaki Saijo; Reiko Kishi


Indoor Air | 2014

Phosphorus flame retardants in indoor dust and their relation to asthma and allergies of inhabitants

Atsuko Araki; Ikue Saito; Ayako Kanazawa; Kanehisa Morimoto; Kunio Nakayama; Eiji Shibata; Masatoshi Tanaka; Tomoko Takigawa; Takesumi Yoshimura; Hisao Chikara; Yasuaki Saijo; Reiko Kishi


International Archives of Occupational and Environmental Health | 2009

Relationship between sick building syndrome and indoor environmental factors in newly built Japanese dwellings

Makoto Takeda; Yasuaki Saijo; Motoyuki Yuasa; Ayako Kanazawa; Atsuko Araki; Reiko Kishi

Collaboration


Dive into the Ayako Kanazawa's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Yasuaki Saijo

Asahikawa Medical University

View shared research outputs
Top Co-Authors

Avatar

Eiji Shibata

Aichi Medical University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge