Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Aykut Recep Aktas is active.

Publication


Featured researches published by Aykut Recep Aktas.


European Journal of Radiology | 2012

Carotid CT-angiography: Low versus standard volume contrast media and low kV protocol for 128-slice MDCT

Mustafa Kayan; Mert Köroğlu; Ahmet Yesildag; Ergün Ceylan; Aykut Recep Aktas; Selçuk Yaşar; Giray Aynali; Cem Parlak; Mehmet Munduz; Cemil Gürses

Availability and utilization of computed tomography angiography has been increasing recently. We aimed to assess the effectiveness of low amount of contrast media and low kV value in order to reduce possible side effects of contrast media and to provide optimization of kV value in the evaluation of the carotid artery with multi-detector computed tomography angiography. Forty one patients were randomized into two groups. Contrast media was administered at a dose of 1 ml/kg in group A patients and of 0.5 ml/kg in group B patients. kV value of 120 in group A and 100 in group B were chosen. Bolus tracking technique was used. Attenuation values of certain arterial segments were measured, and values over 200 HU were considered as significant. North American Symptomatic Carotid Endartherectomy Trial criteria were utilized in the evaluation of stenosis. Image quality in arterial segments of all cases was found to be sufficient for diagnosis. Arterial attenuation values were found to be higher in group B than group A. When compared separately in all arterial segments, there was no statistically significant difference between the groups. For stenosis, 615 arterial segments were evaluated. Moderate stenosis in eight segments and severe stenosis in three segments were identified in group A. Occlusion in three segments, severe stenosis in three segments, and moderate stenosis in 25 segments were detected in group B. Better image quality can be obtained, and the amount of contrast media can be reduced using low kV technique in carotid artery multi-detector computed tomography angiography examination.


Prague medical report | 2012

Pre-operative Arterial Embolization of Symptomatic Giant Hemangioma of the Liver

Mustafa Kayan; Meltem Çetin; Aykut Recep Aktas; Ömer Yılmaz; Ergün Ceylan; H. E. Eroğlu

The cavernous hemangiomas of the liver are usually small sized and asymptomatic. Most of them are incidentally diagnosed and a very small portion requires therapy. Giant hemangioma can be symptomatic, and this condition is the indication for treatment. The striking complication of surgical treatment of cavernous hemangiomas is intra-operative bleeding. In this case, we aimed to demonstrate that the risk of intraoperative bleeding can be eliminated with the preoperative percutaneous trans-catheter arterial embolization technique.


Acta Radiologica | 2011

Endovenous laser ablation and foam sclerotherapy for varicose veins: does the presence of perforating vein insufficiency affect the treatment outcome?

Mert Köroğlu; Hüseyin Naim Eriş; Aykut Recep Aktas; Mustafa Kayan; Ahmet Yesildag; Meltem Çetin; Cem Parlak; Cemil Gürses; Okan Akhan

Background Superficial venous insufficiency is a common problem associated with varicose veins. Endovenous laser ablation (EVLA) and concomitant ultrasound (US)-guided foam sclerotherapy are recent treatment methods alternative to surgery in the treatment of superficial venous insufficiency. Purpose To compare the effectiveness of EVLA and concomitant US-guided foam sclerotherapy prospectively in two different subgroups of the disease (isolated truncal vs. truncal with perforating vein insufficiency). Material and Methods The study was approved by the institutional review board. Fifty-five patients with symptomatic saphenous vein insufficiency and varicose veins were included in the study. Seventy-three EVLA and concomitant foam sclerotherapy were performed for 60 lower extremities. To determine the severity of the venous disease, Venous Clinical Severity Score (VCSS) and Visual Analogue Scale (VAS) were carried out before and 6 months after the treatment. Patients were followed up clinically and with Doppler ultrasonography for 6 months after the procedures. Results At the sixth month of the follow-up; the total occlusion rate for the saphenous veins was 98.64% (72/73), and re-canalization rate was 1.36% (1/73). The total occlusion rate for the perforating veins was 75% (18/24), re-canalization rate was 25% (6/24). There was no notable major complication. VCSS and VAS scores were decreased significantly following the treatment (p < 0.05). The patients who had isolated saphenous vein insufficiency (Group I: 36/60) and those who had saphenous and perforating vein reflux (Group II: 24/60) were compared. VAS scores were more prominently decreased after the treatment in the isolated saphenous vein insufficiency group (p < 0.05). VCSS were also decreased more prominently in Group I when compared to Group II. Conclusion EVLA and concomitant US-guided foam sclerotherapy are effective, safe, and minimally invasive treatment options, yielding good cosmetic and clinical results in both isolated truncal and truncal with perforating vein insufficiency groups. However, clinical results and satisfaction of the patients were remarkably superior in cases with isolated truncal vein insufficiency compared to truncal and perforating vein insufficiency.


Medical Science Monitor | 2013

Diagnostic quality of CT pulmonary angiography in pulmonary thromboembolism: a comparison of three different kV values.

Ömer Yılmaz; Esma Dilek Üstün; Mustafa Kayan; Fatmanur Kayan; Aykut Recep Aktas; Elif Nisa Ünlü; Bumin Değirmenci; Meltem Çetin

Background Our purpose was to evaluate the effectiveness of different kilovolt (kV) uses in computed tomography pulmonary angiography (CTPA) in the diagnosis of pulmonary thromboembolism (PTE). We also aimed to establish the optimal kV value and investigate the possibility of obtaining appropriate imaging quality with minimal radiation dose. Material/Methods We compared 120, 100, and 80 kV CTPA for 90 patients in whom PTE was clinically considered. The examinations were carried out using a 128 multislice CT device (Definition AS, Siemens Medical Solutions, Forchheim, Germany). Each kV value was used on 30 patients in 3 groups. Patients in all groups were compared with respect to the mean radiation dose they received, pulmonary arterial attenuation values, image quality, and motion artefacts. Results With respect to pulmonary arterial attenuation values, imaging with 80 kV yielded significantly higher values (p<0.05). However, no difference was found between 120 kV, 100 kV, and 80 kV with respect to image quality. Similarly, no significant difference was detected between the groups with respect to pulmonary artery contrasting and motion artefacts. Statistically significant differences were present in DLP values and effective dose among all 3 groups (p<0.001). Conclusions Using 80 kV as the low value in CTPA imaging for patients pre-diagnosed with PTE will increase the density of pulmonary arteries and decrease the amount of radiation received.


Surgery Today | 2010

Giant arteriovenous malformation located on the chest wall - diagnosis and endovascular treatment: report of a case.

Sevda Yilmaz; Cansel Atinkaya; Aykut Recep Aktas; Bora Peynircioglu

Congenital arteriovenous malformations are usually found in the lower extremities, but a chest wall location is extremely rare. Extensive vascular malformations present difficulties for patients because of severe unsightliness and life-threatening bleeding. Surgical planning and therapeutic indications in vascular malformations are still a difficult problem. This report describes the case of a 27-year-old woman with a congenital giant arteriovenous malformation of the left chest wall. Preoperative embolization was planned prior to surgical intervention because of the increased risk of massive bleeding, and the malformation was completely embolized with absolute alcohol.


Thoracic Cancer | 2015

Transthoracic biopsy of lung masses: Non technical factors affecting complication occurrence.

Aykut Recep Aktas; Emel Gözlek; Rasih Yazkan; Ömer Yılmaz; Mustafa Kayan; Hakan Demirtaş; Meltem Çetin; Nisa Ünlü; Mustafa Kara; Bumin Değirmenci

To investigate the transthoracic computed tomography (CT)‐guided lung nodule biopsy complications and risk factors associated with the development of these complications.


Acta parasitologica Turcica | 2016

Cystic Eechinococcosis in Childhood: Five-Years of Experience From a Single-Center.

Tugba Koca; Selim Dereci; Ali Gençer; Levent Duman; Aykut Recep Aktas; Mustafa Akcam; Fusun Zeynep Akcam

OBJECTIVE To evaluate the clinical data and prognosis of cystic echinococcosis during a 5-year period who were followed by the pediatric clinics. METHODS Demographic, clinical, laboratory, and prognosis data of 34 patients with cystic echinococcosis obtained between 2009 to 2014 were retrospectively evaluated. Of these, 10 patients were excluded because of incomplete data or failure to follow up. RESULTS A total of 24 (12 males and 12 females) children were included the study. The mean ages of patients were 11.17 ± 3.71 (range, 5-17) years. The most common symptoms were abdominal pain (41.7%), cough (16.7%), and fatigue (12.5%). Localization of the parasite in the patients was determined to be as follows: liver (54.2%), lung (33.3%), and intraabdominal (4.2%). Multiorgan involvement was observed in 8.3% of the cases. Indirect hemagglutination test was positive in 13 (54.2%) patients at admission. All patients received treatment with albendazole. Seven patients were treated with puncture-aspiration-injection-re-aspiration (PAIR) (29.2%). Open surgery was performed in six patients (24.2%). One patient was treated with both PAIR and open surgery. CONCLUSIONS Cystic echinococcosis is a serious public health problem in developing countries. Hydatid cyst should be considered in the presence of suspicious radiological and clinical findings in endemic areas.


Diagnostic and interventional radiology | 2015

CT-guided transthoracic biopsy: histopathologic results and complication rates

Aykut Recep Aktas; Emel Gözlek; Ömer Yilmaz; Mustafa Kayan; Nisa Ünlü; Hakan Demirtaş; Bumin Degirmenci; Mustafa Kara

PURPOSE We aimed to investigate the effectiveness and complications of transthoracic CT-guided biopsy techniques. METHODS A total of 94 CT-guided percutaneous transthoracic biopsy procedures performed in 85 patients were retrospectively evaluated. Core biopsy technique was used in 87 procedures and transthoracic fine-needle aspiration biopsy was used in seven procedures. RESULTS Diagnostic results were achieved in 79 of 94 biopsy procedures. Pathology results were malignant in 54 patients, suspicious for malignancy in three patients, benign in five patients, and benign nonspecific in 17 patients. Specific diagnoses were obtained in 59 patients (62.8%) using core biopsy, but no specific diagnosis could be reached with transthoracic fine-needle aspiration biopsy. Complications included pneumothorax in 27 patients (28.7%) and parenchymal hemorrhage during and after the procedure in eight patients (8.5%). CONCLUSIONS CT-guided percutaneous transthoracic needle biopsy is a highly accurate procedure for histopathological diagnosis of thoracic masses. In addition, percutaneous transthoracic biopsy has an acceptably low complication rate and it reduces the need for more invasive surgical procedures.


Japanese Journal of Radiology | 2013

Early diagnostic clues in neonatal chronic gastric volvulus.

Levent Duman; Mustafa Cagri Savas; Behçet İlker Büyükyavuz; Mustafa Akcam; Gonca Sandal; Aykut Recep Aktas

PurposeNeonatal gastric volvulus (GV) is a rare clinical entity with a challenging diagnosis. In this study, we aimed to identify clinical and radiological findings to aid in early diagnosis in neonatal GV.Materials and methodsThe medical records of all neonates with GV were retrospectively reviewed. Diagnosis was made based on clinical findings and radiological images, and was documented by an upper gastrointestinal (UGI) contrast study.ResultsA total of eight neonates were included in the study. The most common clinical presentations were non-bilious vomiting and epigastric distention. The findings highly suggestive for GV in plain radiographs include gastric double bubble, abnormal gastric distention despite a nasogastric tube, distended stomach lying in a horizontal plane and an air-fluid level in the epigastrium.ConclusionGV should be suspected in any newborn with non-bilious vomiting and epigastric distention. It is also important to focus on the clues in the plain radiographs. Gastric double bubble, abnormal gastric distention despite a nasogastric tube, distended stomach lying in a horizontal plane and an air-fluid level in the epigastrium must alert the physicians to the possibility of GV.


Turkish Journal of Parasitology | 2017

Child with Pancreatic Hydatid Cyst Presenting with Cholestasis

Nagehan Aslan; Tugba Koca; Aykut Recep Aktas; Fusun Zeynep Akcam; Mustafa Akcam

Although hydatid cysts are often seen in the liver and lungs, they may be present in many organs. Even in countries where hydatid cyst disease is endemic, the occurrence of pancreatic hydatid cysts is rare. Pancreatic hydatid cysts are important for the differential diagnosis of patients with pancreatic pseudocysts and cystic carcinomas. We could not find cystic echinococcosis cases which are kept together pancreas and liver in PubMed. In this article, we highlight the fact that pancreatic cystic echinococcosis may play a role in the etiology of cholestasis and that cysts may not be isolated in the pancreas in a pediatric population.

Collaboration


Dive into the Aykut Recep Aktas's collaboration.

Top Co-Authors

Avatar

Mustafa Kayan

Süleyman Demirel University

View shared research outputs
Top Co-Authors

Avatar

Meltem Çetin

Süleyman Demirel University

View shared research outputs
Top Co-Authors

Avatar

Hakan Demirtaş

Süleyman Demirel University

View shared research outputs
Top Co-Authors

Avatar

Mustafa Kara

Süleyman Demirel University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Ömer Yılmaz

Süleyman Demirel University

View shared research outputs
Top Co-Authors

Avatar

Nisa Ünlü

Süleyman Demirel University

View shared research outputs
Top Co-Authors

Avatar

Bumin Değirmenci

Süleyman Demirel University

View shared research outputs
Top Co-Authors

Avatar

Esma Dilek Üstün

Süleyman Demirel University

View shared research outputs
Top Co-Authors

Avatar

Mustafa Akcam

Süleyman Demirel University

View shared research outputs
Researchain Logo
Decentralizing Knowledge