B. Forestier
Blaise Pascal University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by B. Forestier.
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2003
R. Arnaldi; A. Baldit; V. Barret; N. Bastid; G. Blanchard; E. Chiavassa; P. Cortese; P. Crochet; G. Dellacasa; N. De Marco; C. Drancourt; Pascal Dupieux; B. Espagnon; A. Ferretti; B. Forestier; Mauro Gallio; A. Genoux-Lubain; C. Insa; F. Jouve; L. Lamoine; F. Lefèvre; F. Manso; P. Mereu; A. Musso; C. Oppedisano; A. Piccotti; F. Poggio; L. Royer; Ph. Rosnet; P. Saturnini
Abstract The trigger for the Dimuon Forward Spectrometer of the forthcoming ALICE experiment at CERN LHC will be provided by low-resistivity, single gap Resistive Plate Chambers working in streamer mode. Different ageing test were performed to measure and improve the life-time of the detector. Dummy chambers have been built to understand the effects of continuous gas flow upon the Bakelite resistivity: the results concerning our standard gas mixture (49% Ar, 40% forane, 7% isobutane and 4% SF 6 ) are reported, and compared with the same mixture in which ∼1% of water vapor is added. Moreover, two ageing test of 1 month each have been carried out at the Gamma Irradiation Facility at CERN during 2001. The efficiency for cosmic rays under γ irradiation of RPCs coated with different thicknesses of linseed oil was measured. After protracted operation, the detectors have shown an increase of the current and of the background rate. The increase is slower in the chamber with a thicker oil coating.
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2002
R. Arnaldi; A. Baldit; V. Barret; N. Bastid; G. Blanchard; E. Chiavassa; P. Cortese; P. Crochet; G. Dellacasa; N. De Marco; C. Drancourt; Pascal Dupieux; B. Espagnon; A. Ferretti; B. Forestier; C. Insa; F. Jouve; Mauro Gallio; A. Genoux-Lubain; L. Lamoine; F. Lefèvre; F. Manso; P. Mereu; A. Musso; C. Oppedisano; A. Piccotti; O. Roig; P. Rosnet; L. Royer; P. Saturnini
Abstract In the framework of an R&D program on the ALICE dimuon trigger system, the spatial resolution of Resistive Plate Chambers working in streamer mode has been investigated during beam tests. Preliminary studies with cosmic rays had evidenced a dependence of the charge profile to the high voltage and to the gas mixture. However, the spatial resolution measured from the beam tests is only slightly varying with the high voltage and is close to the expected value w/ 12 where w is the strip pitch, for strips of 1 and 2 cm width. The probability to fire a strip as a function of the distance from the strip to the particle impact has been measured for various high voltages. A simple parametrisation of this probability has been achieved. This allows to predict, under various working condition, the cluster size distributions for RPCs with different strip widths and also to account for the effect of the particle incident angle.
ieee nuclear science symposium | 2005
R. Arnaldi; A. Baldit; V. Barret; N. Bastid; G. Blanchard; E. Chiavassa; P. Cortese; P. Crochet; G. Dellacasa; A. Devaux; N. De Marco; P. Dupieux; A. Ferretti; P. Force; B. Forestier; M. Gallio; R. Gemme; S. Grigoryan; F. Guerin; R. Guernane; C. Insa; F. Jouve; F. Manso; P. Mereu; A. Musso; C. Oppedisano; A. Piccotti; F. Poggio; P. Rosnet; L. Royer
A dedicated front-end electronics has been developed for the trigger chambers of the ALICE muon spectrometer under construction at the future LHC at CERN. This trigger detector is based on RPCs (Resistive Plate Chambers) working in streamer mode. The number of electronics channels (about 21000) and the fact that RPC signals have specific characteristics have led to the design of an 8 channel front-end ASIC using a new discrimination technique. The principle of the ASIC is described and the radiation hardness is discussed. Special emphasis is put on production characteristics of about 4000 ASICs.
8th International Workshop on Resistive Plate Chambers and Related Detectors - VIII RPC Workshop | 2006
R. Arnaldi; A. Baldit; V. Barret; N. Bastid; G. Blanchard; E. Chiavassa; A. Colla; P. Cortese; P. Crochet; G. Dellacasa; A. Devaux; N. De Marco; P. Dupieux; A. Ferretti; P. Force; B. Forestier; M. Gagliardi; Mauro Gallio; R. Gemme; S. Grigoryan; F. Guerin; R. Guernane; C. Insa; F. Jouve; F. Manso; P. Mereu; A. Musso; C. Oppedisano; A. Piccotti; F. Poggio
8th International Workshop on Resistive Plate Chambers and Related Detectors - VIII RPC Workshop | 2006
R. Arnaldi; A. Baldit; V. Barret; N. Bastid; G. Blanchard; E. Chiavassa; A. Colla; P. Cortese; P. Crochet; G. Dellacasa; A. Devaux; N. De Marco; P. Dupieux; A. Ferretti; P. Force; B. Forestier; M. Gagliardi; Mauro Gallio; R. Gemme; S. Grigoryan; F. Guerin; R. Guernane; C. Insa; F. Jouve; F. Manso; P. Mereu; A. Musso; C. Oppedisano; A. Piccotti; F. Poggio
8th International Workshop on Resistive Plate Chambers and Related Detectors - VIII RPC Workshop | 2006
R. Arnaldi; A. Baldit; V. Barret; N. Bastid; G. Blanchard; E. Chiavassa; P. Cortese; P. Crochet; G. Dellacasa; A. Devaux; N. De Marco; P. Dupieux; A. Ferretti; P. Force; B. Forestier; M. Gagliardi; Mauro Gallio; R. Gemme; S. Grygorian; F. Guerin; R. Guernane; C. Insa; F. Jouve; F. Manso; P. Mereu; A. Musso; C. Oppedisano; A. Piccotti; F. Poggio; L. Royer
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2004
B. Forestier
IEEE Symposium Conference Record Nuclear Science 2004. | 2004
R. Arnaldi; A. Baldit; V. Barret; N. Bastid; G. Blanchard; E. Chiavassa; P. Cortese; P. Crochet; G. Dellacasa; A. Devaux; N. De Marco; P. Dupieux; A. Ferretti; B. Forestier; M. Gallio; R. Gemme; S. Grygorian; F. Guerin; R. Guernane; C. Insa; F. Jouve; F. Manso; P. Mereu; A. Musso; C. Oppedisano; A. Piccotti; F. Poggio; L. Royer; P. Rosnet; P. Saturnini
IEEE Symposium Conference Record Nuclear Science 2004. | 2004
R. Arnaldi; A. Baldit; V. Barret; N. Bastid; G. Blanchard; E. Chiavassa; P. Cortese; P. Crochet; G. Dellacasa; A. Devaux; N. De Marco; P. Dupieux; A. Ferretti; B. Forestier; M. Gallio; R. Gemme; S. Grygorian; F. Guerin; R. Guernane; C. Insa; F. Jouve; F. Manso; P. Mereu; A. Musso; C. Oppedisano; A. Piccotti; F. Poggio; L. Royer; P. Rosnet; P. Saturnini
nuclear science symposium and medical imaging conference | 2004
R. Arnaldi; A. Baldit; V. Barret; N. Bastid; G. Blanchard; E. Chiavassa; P. Cortese; P. Crochet; G. Dellacasa; A. Devaux; N. De Marco; P. Dupieux; A. Ferretti; B. Forestier; M. Gallio; R. Gemme; S. Grygorian; F. Guerin; R. Guernane; C. Insa; F. Jouve; F. Manso; P. Mereu; A. Musso; C. Oppedisano; A. Piccotti; F. Poggio; L. Royer; P. Rosnet; P. Saturnini