Bankim J. Sanghavi
University of Virginia
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Bankim J. Sanghavi.
Biosensors and Bioelectronics | 2013
Bankim J. Sanghavi; Shaikh M. Mobin; Pradeep Mathur; Goutam Kumar Lahiri; Ashwini K. Srivastava
A dimeric Cu(II) complex [Cu(μ(2)-hep)(hep-H)](2)·2ClO(4) (1) containing bidentate (hep-H=2-(2-hydroxyethyl)pyridine) ligand was synthesized and characterized by single crystal X-ray diffraction studies. Each Cu-ion in 1 is in a distorted square pyramidal geometry. Further 1 along with silver nanoparticles (SNPs) have been used as modifier in the construction of a biomimetic sensor (1-SNP-GCPE) for determining certain catecholamines viz., dopamine (DA), levodopa (l-Dopa), epinephrine (EP) and norepinephrine (NE) using cyclic voltammetry, chronocoulometry, electrochemical impedance spectroscopy and adsorptive stripping square wave voltammetry (AdSSWV). Finally, the catalytic properties of the sensor were characterized by chronoamperometry. Employing AdSSWV, the calibration curves showed linear response ranging between 10(-6) and 10(-9)M for all the four analytes with detection limits (S/N=3) of 8.52×10(-10)M, 2.41×10(-9)M, 3.96×10(-10)M and 3.54×10(-10)M for DA, l-Dopa, EP and NE respectively. The lifetime of the biomimetic sensor was 3 months at room temperature. The prepared modified electrode shows several advantages such as simple preparation method, high sensitivity, high stability, ease of preparation and regeneration of the electrode surface by simple polishing along with excellent reproducibility. The method has been applied for the selective and precise analysis of DA, l-Dopa, EP and NE in pharmaceutical formulations, urine and blood serum samples.
Analytical Chemistry | 2013
Bankim J. Sanghavi; Sarita Sitaula; Mark H. Griep; Shashi P. Karna; Mehnaaz F. Ali; Nathan Swami
We report on a competitive electrochemical detection system that is free of wash steps and enables the real-time monitoring of adenosine triphosphate (ATP) in a quantitative manner over a five-log concentration range. The system utilizes a recognition surface based on ATP aptamer (ATPA) capture probes prebound to electroactive flavin adenine dinucleotide (FAD) molecules, and a signaling surface utilizing graphene (Gr) and gold nanoparticle (AuNP) modified carbon paste electrode (Gr-AuNP-CPE) that is optimized to enhance electron-transfer kinetics and signal sensitivity. Binding of ATP to ATPA at the recognition surface causes the release of an equivalent concentration of FAD that can be quantitatively monitored in real time at the signaling surface, thereby enabling a wide linear working range (1.14 × 10(-10) to 3.0 × 10(-5) M), a low detection limit (2.01 × 10(-11) M using graphene and AuNP modified glassy carbon), and fast target binding kinetics (steady-state signal within 12 min at detection limit). Unlike assays based on capture probe-immobilized electrodes, this double-surface competitive assay offers the ability to speed up target binding kinetics by increasing the capture probe concentration, with no limitations due to intermolecular Coulombic interactions and nonspecific binding. We utilize the real-time monitoring capability to compute kinetic parameters for target binding and to make quantitative distinctions on degree of base-pair mismatch through monitoring target binding kinetics over a wide concentration range. On the basis of the simplicity of the assay chemistry and the quantitative detection of ATP within fruit and serum media, as demonstrated by comparison of ATP levels against those determined using a standard high-performance liquid chromatography (HPLC)-UV absorbance method, we envision a versatile detection platform for applications requiring real-time monitoring over a wide target concentration range.
Analytical Chemistry | 2014
Bankim J. Sanghavi; Walter Varhue; Jorge L. Chávez; Chia-Fu Chou; Nathan Swami
Neuropeptides are vital to the transmission and modulation of neurological signals, with Neuropeptide Y (NPY) and Orexin A (OXA) offering diagnostic information on stress, depression, and neurotrauma. NPY is an especially significant biomarker, since it can be noninvasively collected from sweat, but its detection has been limited by poor sensitivity, long assay times, and the inability to scale-down sample volumes. Herein, we apply electrokinetic preconcentration of the neuropeptide onto patterned graphene-modified electrodes in a nanochannel by frequency-selective dielectrophoresis for 10 s or by electrochemical adsorptive accumulation for 300 s, to enable the electrochemical detection of NPY and OXA at picomolar levels from subnanoliter samples, with sufficient signal sensitivity to avoid interferences from high levels of dopamine and ascorbic acid within biological matrices. Given the high sensitivity of the methodology within small volume samples, we envision its utility toward off-line detection from droplets collected by microdialysis for the eventual measurement of neuropeptides at high spatial and temporal resolutions.
Analytica Chimica Acta | 2012
Bankim J. Sanghavi; Gary Hirsch; Shashi P. Karna; Ashwini K. Srivastava
Carbon nanoparticles (CNPs) and halloysite nanoclay (HNC) modified carbon paste electrode (HNC-CNP-CPE) was developed for the determination of methyl parathion (MP) and ethyl parathion (EP). The electrochemical behavior of these molecules was investigated employing cyclic voltammetry (CV), chronocoulometry (CC), electrochemical impedance spectroscopy (EIS) and potentiometric stripping analysis (PSA). After optimization of analytical conditions employing this electrode at pH 5.0 in acetate buffer (0.1 M), the peak currents were found to vary linearly with its concentration in the range of 1.55×10(-9) to 3.67×10(-6) M and 1.21×10(-9) to 4.92×10(-6) M for MP and EP, respectively. The detection limits (S/N=3) of 4.70×10(-10) M and 3.67×10(-10) M were obtained for MP and EP, respectively, using PSA. The prepared modified electrode showed several advantages such as simple preparation method, high sensitivity, very low detection limits and excellent reproducibility. The proposed method was employed for the determination of MP and EP in fruits, vegetables, water and soil samples.
Analytica Chimica Acta | 2011
Bankim J. Sanghavi; Ashwini K. Srivastava
A glassy carbon paste electrode (GCPE) modified with a cation exchanger resin, Dowex50wx2 and gold nanoparticles (D50wx2-GNP-GCPE) has been developed for individual and simultaneous determination of acetaminophen (ACOP) and tramadol (TRA). The electrochemical behavior of both the molecules has been investigated employing cyclic voltammetry (CV), chronocoulometry (CC), electrochemical impedance spectroscopy (EIS) and adsorptive stripping square wave voltammetry (AdSSWV). The studies revealed that the oxidation of ACOP and TRA is facilitated at D50wx2-GNP-GCPE. Using AdSSWV, the method allowed simultaneous determination of ACOP and TRA in the linear working range of 3.34×10(-8) to 4.22×10(-5) M with detection limits of 4.71×10(-9) and 1.12×10(-8) M (S/N=3) for ACOP and TRA respectively. The prepared modified electrode shows several advantages such as simple preparation method, long-time stability, ease of preparation and regeneration of the electrode surface by simple polishing and excellent reproducibility. The high sensitivity and selectivity of D50wx2-GNP-GCPE were demonstrated by its practical application in the determination of both ACOP and TRA in pharmaceutical formulations, urine and blood serum samples.
Analytical Chemistry | 2010
Shaikh M. Mobin; Bankim J. Sanghavi; Ashwini K. Srivastava; Pradeep Mathur; Goutam Kumar Lahiri
A new dimeric Cu(II) complex [Cu(mu(2)-hep)(hep-H)](2).2PF(6) (1) containing a bidentate (hep-H = 2-(2-hydroxyethyl)pyridine) ligand was synthesized and characterized by single crystal X-ray diffraction studies. Each Cu ion in 1 is in a distorted square pyramidal geometry. Further 1 is used as a modifier in the construction of a biomimetic sensor for determining phenols [phenol (Phe), resorcinol (Res), hydroquinone (HQ), and catechol (Cat)] in phosphate buffer by using cyclic voltammetry (CV), chronocoulometry, electrochemical impedance spectroscopy (EIS), differential pulse voltammetry (DPV), and square wave voltammetry (SWV). DPV has been proposed for trace determination of Phe and Res while SWV for HQ and Cat. The method has been applied for the selective and precise analysis of Phe in commercial injections, Res in hair coloring agents, HQ in photographic developers and cosmetics, and Cat in tea samples and guarana tablets. The calibration curves showed a linear response ranging between 10(-6) and 10(-8) M for all four of the analytes with detection limits (3sigma) of 1.04 x 10(-8), 2.31 x 10(-8), 1.54 x 10(-8), and 0.86 x 10(-8) M for Phe, Res, HQ, and Cat, respectively. The lifetime of the biomimetic sensor was 200 days at room temperature (at least 750 determinations). The catalytic properties of 1-CPE were characterized by chronoamperometry and were found to be in good agreement with Michaelis-Menten kinetics.
Talanta | 2014
Bankim J. Sanghavi; Pramod K. Kalambate; Shashi P. Karna; Ashwini K. Srivastava
A mixture of graphene oxide and tetrachloroauric acid was electrochemically co-reduced directly on a glassy carbon electrode (GCE) surface via cyclic voltammetry so as to form a graphene (Gr)-gold nanoparticles (AuNP) composite. This nanocomposite was then coated with nafion (NAF) film so as to form Gr/AuNP/NAF/GCE. Sumatriptan (SUM) is a drug belonging to the triptan class, used for the treatment of migraine headaches. In this work, an electrochemical method based on the adsorptive stripping differential pulse voltammetry (AdSDPV) employing Gr/AuNP/NAF/GCE has been proposed for the subnanomolar determination of SUM. Characterization of the electrode material has been carried out by UV-visible spectrophotometry, X-ray diffraction and scanning electron microscopy. Also the electrode surface has been characterized by means of cyclic voltammetry, electrochemical impedance spectroscopy, chronocoulometry. By employing Gr/AuNP/NAF/GCE at pH 7.0 phosphate buffer, a 20-fold enhancement in the AdSDPV signal was observed as compared to GCE. Under the optimized conditions, Ip (µA) was proportional to the SUM concentration in the range of 1.0×10(-6)-4.12×10(-5) M (R(2)=0.9991) and 2.14×10(-9)-1.0×10(-6) M (R(2)=0.9954) with a detection limit (3×SD/s) of 7.03×10(-10) M. The practical analytical utilities of the modified electrode were demonstrated by the determination of SUM in pharmaceutical formulations, human urine and blood serum samples. This proposed method was validated by HPLC and the results are in agreement at the 95% confidence level.
Biosensors and Bioelectronics | 2016
Bankim J. Sanghavi; John A. Moore; Jorge L. Chávez; Joshua A. Hagen; Nancy Kelley-Loughnane; Chia-Fu Chou; Nathan Swami
Monitoring the periodic diurnal variations in cortisol from small volume samples of serum or saliva is of great interest, due to the regulatory role of cortisol within various physiological functions and stress symptoms. Current detection assays are immunologically based and require cumbersome antibody immobilization chemistries, thereby limiting the assay versatility, kinetics, and reproducibility. We present a quantitative aptamer-based detection methodology for cortisol that does not require target labeling, capture probe immobilization on the detection surface or wash steps prior to readout. Using a recognition system of aptamer functionalized gold nanoparticles pre-bound with electro-active triamcinolone, the cortisol level is detected based on its competitive binding to the aptamer by following signal from the displaced triamcinolone using square wave voltammetry at patterned graphene-modified electrodes in a microfluidic or nanoslit device. Due to the 3D analyte diffusion profile at the aptamer interface and the ability to enhance the surface area for cortisol capture, this assay shows signal linearity over a five-log analyte concentration range (10 μg/mL to 30 pg/mL) and exhibits rapid binding kinetics with cortisol versus other glucocorticoids, as apparent from the absence of interferences from estradiol, testosterone and progesterone. The assay is carried out within the biologically relevant range for glucocorticoids in serum and saliva matrices, and benchmarked versus ELISA and radioimmunoassays. Based on absence of cumbersome surface immobilization and wash steps for carrying out this assay, its quantitative signal characteristics and its ability to resist interferences from other glucocorticoids, we envision its application towards routine monitoring of cortisol within bio-fluids.
Analytica Chimica Acta | 2011
Nayan S. Gadhari; Bankim J. Sanghavi; Ashwini K. Srivastava
An electrochemical method based on potentiometric stripping analysis (PSA) employing a hexathia 18C6 (HT18C6) and rice husk (RH) modified carbon paste electrode (HT18C6-RH-CPE) has been proposed for the subnanomolar determination of antimony. The characterization of the electrode surface has been carried out by means of scanning electron microscopy, cyclic voltammetry, electrochemical impedance spectroscopy and chronocoulometry. By employing HT18C6-RH-CPE, a 12-fold enhancement in the PSA signal (dt/dE) was observed as compared to plain carbon paste electrode (PCPE). Under the optimized conditions, dt/dE (sV(-1)) was proportional to the Sb(III) concentration in the range of 1.42×10(-8) to 6.89×10(-11)M (r=0.9944) with the detection limit (S/N=3) of 2.11×10(-11)M. The practical analytical utilities of the modified electrode were demonstrated by the determination of antimony in pharmaceutical formulations, human hair, sea water, urine and blood serum samples. The prepared modified electrode showed several advantages, such as simple preparation method, high sensitivity, very low detection limit and excellent reproducibility. Moreover, the results obtained for antimony analysis in commercial and real samples using HT18C6-RH-CPE and those obtained by inductively coupled plasma-atomic emission spectrometry (ICP-AES) are in agreement at the 95% confidence level.
Electrochimica Acta | 2010
Bankim J. Sanghavi; Ashwini K. Srivastava